Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Containerless processing of Nb-Ge alloys in a long drop tube

The thirty-two meter drop tube at the Marshall Space Flight Center was used to study the effect of zero gravity containerless processing on the structure and properties of materials. The concept involves the suppression of heterogeneous nucleation of solid in liquid and, therefore, solidification accompanied by large degrees of undercooling. Under these conditions metastable phases can be formed or, at the very least, unique nonequilibrium microstructures (containing equilibrium phases) with unique properties can be produced. The drop tube solidification was applied to niobium base alloys with emphasis on the Nb-Ge binary system in an effort to produce metastable phases with high superconducting transition temperatures in bulk specimens. In the past, only lower Ge alloys (Nb-13 a/o, Nb-18 a/o, and Nb-22 a/o) could be undercooled. Higher Ge alloys (e.g., Nb-25 a/o Ge and Nb-27 a/o Ge) can now be undercooled on a routine basis.

Bayuzick, R. J.↗

Absence of equilibrium among close-packed twisted flux tubes

The lack of equilibrium in twisted, close-packed flux tubes is demonstrated in terms of a topology of the transverse field and the necessity of defining restricted solutions for an arbitrary function in the equilibrium equation. It is shown that nearly all combinations of flux connections and functional forms have no mutual equilibrium and that the flux connections in nature are formed by footprint convection at an origin. The most close-packed twisted flux tubes are subject to dynamical nonequilibrium, with the transverse flux connections being reduced through neutral point rapid reconnection. The precise solutions which can be obtained through functional forms in the equilibrium equation do not have an analog in the real world.

Parker, E. N.↗

Effect of cultural conditions on the seed-to-seed growth of Arabidopsis and Cardamine - A study of growth rates and reproductive development as affected by test tube seals

The effects of test tube seals on the growth, flowering, and seed pod formation of Arabidopsis thaliana (L.) Heynh., mouse ear cress, and Cardamine oligosperma Nutt, bitter cress, are studied in order to assess the conditions used in weightlessness experiments. Among other results, it is found that the growth (height) and flowering (date of bud appearance) were suppressed in mouse ear cress in tubes sealed with Saran. Seed pod formation which occurred by day 45 in open-to-air controls, was still lacking in the sealed plants even up to day 124. The growth and flowering of bitter cress were also suppressed by the Saran seal, although up to day 55 the Saran-sealed plants were taller. It is suggested that atmospheric composition was the cause of the suppression of growth, flowering, and seed pod development in these plants, since the mouse ear cress renewed their growth and then set seed pods after the Saran seal was ruptured.

Hoshizaki, T.↗

Unsteady turbulent shear flow in shock tube discontinuities

A pressure-ruptured shock tube and an arc driven shock tube, have been used to study the evolution of turbulent fluctuations at contact surfaces with N2O4-2NO2 mixtures and at ionizing shock fronts in argon. The study has focused on point density diagnostics derived from crossed light beam correlations and electric probes. Turbulent bursts are found for which dynamical and spectral analyses suggest a particle-like evolution of fluctuation segments with a unique and characteristic frequency, independent of flow history and overall flow conditions.

Johnson, J. A., III↗

Tube-Wall Thickness Detector

Eddy-current measurements detect wear of thin walls (0.01 in) (0.25 mm) in small diameter (0.19 in) (5 mm) heat exchanger tubing. Flexible durable thin rod inserts eddy-current coil into the heatexchanger tube.

Kleint, R. E.↗

Annular-Tube Reinforcer

Cylindrical tool inserts support sleeves into annular space between coaxial tubes to provide local reinforcement. Tool particularly useful when space between outer ends of coaxial tubes is narrow, requiring thin sleeve.

Pessin, R.↗

Microphone Detects Boiler-Tube Leaks

Unit simple, sensitive, rugged, and reliable. Diaphragmless microphone detects leaks from small boiler tubes. Porous plug retains carbon granules in tube while allowing pressure changes to penetrate to granules. Has greater life expectancy than previous controllers and used in variety of hot corrosive atmospheres.

Parthasarathy, S. P.↗

Interfacing a Two-Stage Image Intensifier Tube to an Echelle Spectrograph

An Echelle spectrograph has been in use at the Marshall Space Flight Center for a number of years. Research has been carried out in the study of the internal motions of ionized gas clouds in the interstellar medium. In order to extend the ability of the spectrograph to allow investigations of the faint outer regions of the gas clouds and to make possible the initiatiion of new research programs dealing with the study of sunspots and the zodiacal light, a two-stage image intensifier tube was incorporated into the instrument. The objective of this work was to interface the image tube with the spectrograph.

Flesch, T. R.↗

Residual stresses in cross-ply composite tubes

The residual thermal stresses in 4-layer cross-ply tubes are studied. The tubes considered has a small radius to wall-thickness ratios and so elasticity solutions were used. The residual thermal stress problem was considered to be axisymmetric and three elasticity solutions were derived and the results compared with the results using classical lamination theory. The comparison illustrates the limitations of classical lamination theory. The three elasticity solutions derived were: plane stress, plane strain, and generalized plane strain, the latter being the most realistic. Residual stresses in both the hoop and axial direction is significant. Stacking arrangement effects the residual stress to some extent, as do the material properties of the individual lamina. The benefits of hybrid construction are briefly discussed.

Cohen, D.↗

Region one Birkeland currents connecting to sunward convecting flux tubes

On the basis of Birkeland current observations, analytic stability arguments demonstrate that there may be a sector within the plasma sheet in the night side magnetosphere where plasma pressures are reduced relative to the surrounding regions. Physical arguments, in addition to this analysis, imply that a depleted region near the center of the magnetotail would be stable against the interchange instability, thereby generating currents of the same sense as the region-1 currents. The depleted region is presently simulated by means of computer experiments based on the Rice Convection Model. Results indicate that flux tube content gradients across the tailward boundary can cause region-1 currents to flow along sunward-convecting flux tubes, in general agreement with satellite data.

Karty, J. L.↗

Making Glass-Fiber-Reinforced Coolant Tubes

New use found for heat-shrinkable sleeves. Smooth, noncontaminating channels for transporting cooling water in Space Shuttle Extravehicularmobility unit made of fiberglass tubing with aid of heat-shrinkable sleeves. Previously, glass fibers from inner walls of tubes contaminate water.

Curtin, F.↗

Replaceable Transfer Tube for High-Pressure Cavities

Set of fittings allows fluid injected into inner chamber, passing through two cavities containing fluids at different high pressures. Injection tube readily replaced, and fittings provide tight seal between cavities after replacement. Tube and fittings made from off-the-shelf parts, and familiar to workers and relatively inexpensive.

Sorensen, D.↗

Microgravity containerless processing in long drop tubes

Extensive experience in utilizing long drop tubes for studying effects of microgravity on the solidification of alloys was obtained. While some modifications are necessary to improve versatility, the facility proved to be most useful. Both an electron beam furnace and an electromagnetic levitation furnace can be used. The electron beam furnace is used with vacuum environments (0.00001 torr), whereas the levitation furnace is presently used only in inert gas environments (above 100 torr). Experiments are best applied to refractory alloys because of the sensitivity of the detectors now being used to observe solidification. Processing of lower melting point metals and alloys simply cannot be recorded. On the other hand, expected improvements in detector sensitivity will allow experimentation with relatively low melting alloys. In such cases, solidification will occur in flight only if higher inert gas pressure is used (100 to 760 torr) to increase heat loss by convection. Under these conditions microgravity conditions no longer apply. However, as shown by results to date, it is not microgravity as such that is important in drop tube solidification. Instead it is the containerless nature of the process that is significant, leading to large degrees of undercooling before solidification and therefore to unique alloys.

Bayuzick, R. J.↗

Containerless drop tube solidification and grain refinement of NiAl3

The possibility of undercooling Ni-Al alloys below the liquidus in order to produce a single phase peritectic structure by containerless drop tube solidification was studied. Containerless process is a technique for both high purity contamination free studies as well as for investigating the undercooling and rapid solidification of alloys by suppression of heterogeneous nucleation on container walls. In order to achieve large undercoolings one must avoid heterogeneous nucleation of crystallization. It was shown that the Marshall Space Flight Center drop tubes ae unique facilities for containerless solidification experiments and large undercoolings are possible with some alloys. The original goal of undercooling the liquid metal well below the liquidus to the peritectic temperature during containerless free to form primarily NiAl3 was achieved. The microstructures were interesting from another point of view. The microstructure from small diameter samples is greatly refined. Small dendrite arm spacings such as these could greatly facilitate the annealing and solid state transformation of the alloy to nearly 10% NiAl3 by reducing the distance over which diffusion needs to occur. This could minimize annealing time and might make it economically feasible to produce NiAl3 alloy.

Ethridge, E. C.↗

Dynamic models of flux tubes in the interpretation of polarization measurements

Recent observations of Stokes parameter profiles indicate the presence of mass motions with large velocity gradients associated with small-scale magnetic elements. Dynamic models of flux tubes were used in order to interpret observations of unresolved elements. It is clear that the physical picture of the dynamic models will be quite different from the hydrostatic ones since there is a strong coupling between the magnetic and the velocity field. Polarization measurements have to be interpreted in terms of dynamic models. Two-D steady flow solutions in slender magnetic tubes have been worked out. It was found that the main properties of the intensity line profiles as well as the asymmetries of the V Stokes profiles can be explained best in terms of magnetic elements with moderate field strength.

Ribes-Nesme, E.↗

A review of long drop tubes as a supplement/alternative to space experiments

A description of the 100-m drop tube at the Marshall Space Flight Center is presented, along with some undercooling observations and a discussion of some microstructural properties of deeply undercooled Nb-Ge alloys. The facility comprises two turbopumps which can evacuate the tube to 0.00001 torr, and three IR detectors at 15, 80, and 103-m levels which are sensitive to light in the range of 9660-2635 K (wavelength range of 0.2 to 1.1 microns), though recalescence events were detected at 1700 K. Finally, hypercooling regimes and maximum possible undercooling in vacuum are defined for several materials, including Al, Cu, Ni, Fe, Pt, and Nb.

Bayuzick, R. J.↗

In situ measurements of the plasma bulk velocity near the Io flux tube

The flow around the Io flux tube was studied by analyzing the eleven spectra taken by the Voyager 1 Plasma Science (PLS) experiment in its vicinity. The bulk plasma parameters were determined using a procedure that uses the full response function of the instrument and the data in all four PLS sensors. The mass density of the plasma in the vicinity of Io is found to be 22,500 + or - 2,500 amu/cu cm and its electron density is found to be 1500 + or - 200/cu cm. The Alfven speed was determined using three independent methods; the values obtained are consistent and taken together yield V sub A = 300 + or - 50 km/sec, corresponding to an Alfven Mach number of 0.19 + or - 0.02. For the flow pattern, good agreement was found with the model of Neubauer (1980), and it was concluded that the plasma flows around the flux tube with a pattern similar to the flow of an incompressible fluid around a long cylinder obstacle of radius 1.26 + or - 0.1 R sub Io.

Barnett, A.↗

Biaxial fatigue properties of thin-walled composite tubes

A testing method for obtaining fatigue and fracture data under biaxial loading and for negative R-ratios is described. Thin-walled tubes of 1-in. outer nominal diameter with a tapered grip section were tested in an Axial-Torsion Servohydraulic Testing Machine with a 463 Data Control Processor at frequencies below 10 Hz up to the 1-million cycle range. Room temperature, uniaxial constant amplitude fatigue data for high temperature cure graphite-epoxy material are presented at R = -0.4 for a (+, - 5 deg) fiber orientation. The fatigue curve is almost horizontal. Tests on (+, - 5 deg) 'SP-328' resulted in failures which predominantly originated in the grip section. Presently, a new specimen design is being tested intended to eliminate cracking in the grip section. Biaxial in-phase loading of (0/+, - 45) tubes of Fiberite graphite-epoxy resulted in much steeper fatigue curves than observed under uniaxial loading.

Krempl, E.↗