Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Flight Tests on a Fiber Optic Temperature Sensor

For aircraft engine control, one key parameter to detect on an airplane is the exhaust gas temperature (EGT). Presently, thermocouples are used to perform this measurement. These electrical sensors perform adequately; however, fully utilizing the benefits of optical sensors requires replacing electrical architectures with optical architectures. Part of this requires replacing electrical sensors with optical sensors, such as the EGT sensor chosen for these tests. The objective of the development and testing of this prototype sensor system was to determine the feasibility of operating an optical sensor in a hostile aircraft environment. The fiber optic sensor system was developed to measure temperatures from 20C to 600C in an aircraft environment and was utilized to monitor the EGT of an OV-10D aircraft engine. The sensor has successfully flown over 50 hours and proven to be immune to surface deterioration of the optical element (located inside the sensor head) and able to withstand and operate in normal and sustained severe flight conditions where forces on the airplane exceeded 4 g's. Potential commercial uses for this sensor include monitoring temperature for aeropropulsion system control, military vehicle and naval engine control, conventional and nuclear power plant monitoring and industrial plan monitoring where EMI issues are critical.

Tuma, Margaret L.↗

Turnover of Biogenic Amines in the Hypothalamus of Rats during Pyrogen Fever

Many pharmacological studies have implicated the biogenic amines in the hypothalamus as playing a role in the production of fever, but few investigations of endogenous neurochemicals have been made during fever. Turnover rates of transmitters utilizing radioactive precursors may be one of the most accurate measurements of activity in brain regions. The present study was designed to measure the turnover of 5-hydroxytryptamine (5-HT) norepinephrine (NE) and dopamine (DA) in the hypothalamus of rats during pyrogen fever. Salmonella typhosa (Wyeth, 8 units) was previously found in our laboratory to produce a significant hyperthermia in most rats by 2.5 hours. This pyrogen (N = l2) or saline control (N = 8) was injected intraperitoneally and the rats killed 2.75 hours later. Rectal temperatures (Tr) were monitored continuously with thermocouples taped to the tail and recorded automatically every 3 minutes. Half of each group received an injection of radioactive precursors, (3)H-tryptophan (0.5 mCi) and (3)H-tryptophan (1.0 mCi), via an indwelling jugular catheter 60 minutes before killing, and the other half at 90 minutes. The rats were killed by near freezing in liquid nitrogen and the brains dissected in the cold. Turnover was measured by the method of Lane (Life Sci 21, 1101, 1977). At the time of killing most of the pyrogen group showed a significant (p < .02) increase (mean +/- s.e.m.) in Tr above pre injection levels (0.75 +/- 0.13 C, N = 10). The saline group showed no change (-0.025 +/- 0.16, N = 8), and the difference between groups was also significant. No significant differences were found in the levels of the amines between the pyrogen and saline groups. A significant difference was found in the specific activity of NE between the 60 minute pyrogen and saline groups (4.41 +/- 0.41 vs 2.6 +/- 0.51 dpm/pmole) but no change in turnover. This suggests an increased accumulation of (3)H-NE in the pyrogen group, but no change in utilization. An increased turnover of DA for the pyrogen group (44.5 vs 19.2 pmole/mg protein/hr) was found. However, DA is mainly a precursor in the hypothalamus and measurement was near the limit of sensitivity for the assay; these limitations Must be considered in interpreting this data. The most significant finding was an increase in the turnover of 5-HT in the pyrogen group (41.3 vs 7.3 pmole/mg protein/hr), indicating a resynthetization rate of 77% of the total pool per hour. These results suggest that at the time point measured, an increase in the utilization of 5-HT in the hypothalamus is-correlated with pyrogen fever.

Penn, P. E.↗

Development Unit Configuration and Current Status of the MIP/MAAC Experiment

The Mars In-Situ Propellant Production (ISPP) Precursor (MIP) experiment package is planned for inclusion on the Mars 2001 Lander. This experiment package consists of five experiments whose purpose is to demonstrate the performance of various ISPP processes in-situ on Mars. The demonstrated ability to produce propellant for Mars Return Vehicles (MRV) is considered to be a necessary precursor to any future manned mission to Mars. The Mars Atmosphere Acquisition and Compression (MAAC) experiment is part of the MIP package and is intended to demonstrate that, by using a sorption compressor, CO2 can be preferentially adsorbed at about 6 torr from the Mars atmosphere during the night when the bed is cold then subsequently compressed to about 800 torr by heating the bed and desorbing CO2 during the day. The compressed CO2 produced by MAAC is to be fed to the Oxygen Generator Subsystem (OGS) where pure oxygen is to be produced. Pure oxygen is considered to be one of the primary constituents of a future manned MRV propellant system. A MAAC Development Unit (DU) has been fabricated and tested at JPL. The MAAC DU consists of 1) a sorption bed filled with a CO2 selective sorbent material, 2) a purge system to be used to periodically backflush non-CO2 gases from the sorbent bed during adsorption, 3) a JPL-developed gas-gap heat switch that allows heat transfer to a radiator for heat removal from the bed during the night time adsorption period and that impedes heat transfer during the day time desorption period, 4) a radiator to radiate heat to the night sky during the adsorption period, 5) a set of three isolation valves and connecting tubing. 6) two pressure transducers and several thermocouples for monitoring the MAAC operating conditions, and command and data handling electronics. This paper will describe the operational theory and the configuration of the MAAC DU and will discuss the current status of the MAAC experiment development including some selected results of performance testing that has been completed prior to the ISRU III meeting.

Karlmann, P. B.↗

A Precise Calibration Technique for Measuring High Gas Temperatures

A technique was developed for direct measurement of gas temperatures in the range of 2050 K - 2700 K with improved accuracy and reproducibility. The technique utilized the low-emittance of certain fibrous Materials, and the uncertainty of the technique was limited by the uncertainty in the melting points of the materials, i.e., +/- 15 K. The materials were pure, thin, metal-oxide fibers whose diameters varied from 60 mm to 400 mm in the experiments. The sharp increase in the emittance of the fibers upon melting was utilized as indication of reaching a known gas temperature. The accuracy of the technique was confirmed by both calculated low emittance values of transparent fibers, of order 0.01, up to a few degrees below their melting point and by the fiber-diameter independence of the results. This melting-point temperature was approached by increments not larger than 4 K, which was accomplished by controlled increases of reactant flow rates in hydrogen-air and/or hydrogen- oxygen flames. As examples of the applications of the technique, the gas-temperature measurements were used (a) for assessing the uncertainty in infering gas temperatures from thermocouple measurements, and (b) for calibrating an IR camera to measure gas temperatures. The technique offers an excellent calibration reference for other gas-temperature measurement methods to improve their accuracy and reliably extending their temperature range of applicability.

Gokoglu, Suleyman A.↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

Fluctuations of the electrical resistivity due to inhomogeneous dopant distribution are still a serious problem for the industrial processing yield of doped silicon crystals. In the case of silicon floating-zone growth, the main sources of these inhomogeneities are time- dependent flows in the liquid phase during the growth process. Excluding radio frequency (RF) induced convection, buoyancy and thermocapillary (Marangoni) convection are the two natural reasons for fluid flow. Both originate from temperature/concentration gradients in the melt, buoyancy convection through thermal/concentrational volume expansion, and thermocapillary convection through the temperature/concentration dependence of the surface tension. To improve the properties of grown crystals, knowledge of the strength, the characteristic, and the relation of these two flow mechanisms is essential. By the use of microgravity, the effect and the strength of buoyancy (gravity dependent) and thermocapillary (gravity independent) convection can be separated and clarified. Applying magnetic fields, both convective modes can be influenced: fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). Two complementary approaches have been pursued: Silicon full zones (experiments on the German sounding rockets TEXUS 7, 12, 22, 29, and 36) with the maximum temperature at half of the zone height and silicon half zones (experiments on the Japanese sounding rockets TR-IA4 and 6) with the maximum temperature at the top of the melt. With the full zone arrangement, the intensity and the frequency of the dopant striations could be determined and the critical Marangoni number could be identified. The half zone configuration is suited to classify the flow pattern and to measure the amplitude and the frequency of temperature fluctuations in the melt by inserting thermocouples or temperature sensors into the melt. All experiments have been carried out in monoellipsoid mirror furnaces. Typical zone geometries are approx. 8 to 14 mm in diameter and height. The crystals grown under microgravity are compared to crystals grown in static axial magnetic fields (B<5 tesla) and in transversal rotating magnetic fields (B<7.5 mT / f=50 Hz). Experimental results are completed by 3D numerical simulations: the obtained temperature and concentration distribution in the melt confirm the damping effect of rotating magnetic fields and explain the change in the radial segregation under static magnetic fields.

Dold, P.↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

Growing crystals by the floating zone (FZ) technique under microgravity avoids the size restriction we have under earth conditions due to hydrostatic pressure. Further, buoyancy related convection is eliminated to a great degree. But in the case of silicon, the gravity independent thermocapillary (Marangoni) convection is time-dependent even for small zone geometries. This has been demonstrated in several Technische Experimente unter Schwerelosigkeit (TEXUS) technical experiments under reduced gravity flights. Thus, to really take advantage of microgravity with respect to improved crystal quality, tools are required to control Marangoni convection in space facilities. With the application of magnetic fields, convection can be influenced; fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). In floating zones of 8-10 mm diameter and height (i.e., Ma is much greater than 6X 10(exp 3), a static magnetic field of about 2OOmT is sufficient to suppress time-dependent Marangoni convection to a high degree, but in dependence on the kind and the concentration of the added dopant, a new type of strongly pronounced dopant inhomogeneities have been detected. They are originated by thermoelectromagnetic convection. This can be avoided as well as detrimental effects on the radial dopant distribution by using rotating magnetic fields instead of static ones. Applying 7.5mT/5OHz to the FZ, the intensity of the dopant fluctuations is reduced to a high degree. Considering the rather low power consumption of rotating magnetic fields, this will be a useful tool for control or elimination of time-dependent Marangoni convection under microgravity. The strong time-dependent character of thermocapillary flow and its influence on the temperature field has been measured in silicon half-zones for Marangoni numbers of Ma is much greater than l - 1.5 X 10(exp 4): temperature fluctuations up to 4C have been determined, their frequency range was 0.4 and 0.4Hz. Between certain thermocouple or sensor pairs, strong correlation has been detected.

Dold, P.↗

Development Unit Configuration Status of the MIP/MAAC Experiment

The Mars In-Situ Propellant Production (ISPP) Precursor (MIP) experiment package is planned for inclusion on the Mars 2001 Lander. This experiment package consists of five experiments whose purpose is to demonstrate the performance of various ISPP processes in-situ on Mars. The demonstrated ability to produce propellant for Mars Return Vehicles (MRV) is considered to be a necessary precursor to any future manned mission to Mars. The Mars Atmosphere Acquisition and Compression (MAAC) experiment is part of the MIP package and is intended to demonstrate that, by using a sorption compressor, CO2 can be preferentially adsorbed at about 6 torr from the Mars atmosphere during the night when the bed is cold then subsequently compressed to about 800 torr by heating the bed and desorbing C02 during the day. The compressed CO2 produced by MAAC is to be fed to the Oxygen Generator Subsystem (OGS) where pure oxygen is to be produced. Pure oxygen is considered to be one of the primary constituents of a future manned MRV propellant system. A MAAC Development Unit (DU) has been fabricated and tested at JPL. The MAAC DU consists of: (1) a sorption bed filled with a CO2 selective sorbent material; (2) a purge system to be used to periodically backflush non-CO2 gases from the sorbent bed during adsorption; (3) a JPL-developed gas-gap heat switch that allows heat transfer to a radiator for heat removal from the bed during the night time adsorption period and that impedes heat transfer during the day time desorption period; (4) a radiator to radiate heat to the night sky during the adsorption period; (5) a set of three isolation valves and connecting tubing; (6) two pressure transducers and several thermocouples for monitoring the MAAC operating conditions, and command and data handling electronics. This paper will describe the operational theory and the configuration of the MAAC DU and will discuss the current status of the MAAC experiment development including some selected results of performance testing that has been completed prior to the ISRU III meeting.

Karlmann, P. B.↗

Instrumentation Working Group Summary

The Instrumentation Working Group compiled a summary of measurement techniques applicable to gas turbine engine aerosol precursors and particulates. An assessment was made of the limits, accuracy, applicability, and technology readiness of the various techniques. Despite advances made in emissions characterization of aircraft engines, uncertainties still exist in the mechanisms by which aerosols and particulates are produced in the near-field engine exhaust. To adequately assess current understanding of the formation of sulfuric acid aerosols in the exhaust plumes of gas turbine engines, measurements are required to determine the degree and importance of sulfur oxidation in the turbine and at the engine exit. Ideally, concentrations of all sulfur species would be acquired, with emphasis on SO2 and SO3. Numerous options exist for extractive and non-extractive measurement of SO2 at the engine exit, most of which are well developed. SO2 measurements should be performed first to place an upper bound on the percentage of SO2 oxidation. If extractive and non-extractive techniques indicate that a large amount of the fuel sulfur is not detected as SO2, then efforts are needed to improve techniques for SO3 measurements. Additional work will be required to account for the fuel sulfur in the engine exhaust. Chemical Ionization Mass Spectrometry (CI-MS) measurements need to be pursued, although a careful assessment needs to be made of the sampling line impact on the extracted sample composition. Efforts should also be placed on implementing non-intrusive techniques and extending their capabilities by maximizing exhaust coverage for line-of-sight measurements, as well as development of 2-D techniques, where feasible. Recommendations were made to continue engine exit and combustor measurements of particulates. Particulate measurements should include particle size distribution, mass fraction, hydration properties, and volatile fraction. However, methods to ensure that unaltered samples are obtained need to be developed. Particulate speciation was also assigned a high priority for quantifying the fractions of carbon soot, PAH, refractory materials, metals, sulfates, and nitrates. High priority was also placed on performing a comparison of particle sizing instruments. Concern was expressed by the workshop attendees who routinely make particulate measurements about the variation in number density measured during in-flight tests by different instruments. In some cases, measurements performed by different groups of researchers during the same flight tests showed an order of magnitude variation. Second priority was assigned to measuring concentrations of odd hydrogen and oxidizing species. Since OH, HO2, H2O2, and O are extremely reactive, non-extractive measurements are recommended. A combination of absorption and fluorescence is anticipated to be effective for OH measurements in the combustor and at the engine exit. Extractive measurements of HO2 have been made in the stratosphere, where the ambient level of OH is relatively low. Use of techniques that convert HO2 to OH for combustor and engine exit measurements needs to be evaluated, since the ratio of HO2/OH may be 1% or less at both the combustor and engine exit. CI-MS might be a viable option for H2O2, subject to sampling line conversion issues. However, H2O2 is a low priority oxidizing species in the combustor and at the engine exit. Two candidates for atomic oxygen measurements are Resonance Enhanced Multi-Photon Ionization (REMPI) and Laser-Induced Fluorescence (LIF). Particulate measurement by simultaneous extractive and non-extractive techniques was given equal priority to the oxidizer measurements. Concern was expressed over the ability of typical ground test sampling lines to deliver an unaltered sample to a remotely located instrument. It was suggested that the sampling probe and line losses be checked out by attempting measurements using an optical or non-extractive technique immediately upstream of the sampling probe. This is a possible application for Laser Induced Incandescence (LII) as a check on the volume fraction of soot. Optical measurements of size distribution are not well developed for ultrafine particles less than about 20 nm in diameter, so a non-extractive technique for particulate size distribution cannot be recommended without further development. Carbon dioxide measurements need to be made to complement other extractive measurement techniques. CO2 measurements enable conversion of other species concentrations to emission indices. Carbon monoxide, which acts as a sink for oxidizing species, should be measured using non-extractive techniques. CO can be rapidly converted to CO2 in extractive probes, and a comparison between extractive and non-extractive measurements should be performed. Development of non-extractive techniques would help to assess the degree of CO conversion, and might be needed to improve the concentration measurement accuracy. Measurements of NO(x) will continue to be critical due to the role of NO and NO2 in atmospheric chemistry, and their influence on atmospheric ozone. Time-resolved measurements of temperature, velocity, and species concentrations were included on the list of desired measurement. Thermocouples are typically adequate for engine exit measurements. PIV and LDV are well established for obtaining velocity profiles. The techniques are listed in the accompanying table; are divided into extractive and non-extractive techniques. Efforts were made to include a measurement uncertainty for each technique. An assessment of the technology readiness was included.

Zaller, Michelle↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

In growing crystals by the floating zone (FZ) technique under microgravity, the size restriction we have under earth conditions because of the hydrostatic pressure are avoided. Further, buoyancy related convection is eliminated to a high degree. But in the case of silicon, the gravity independent thermocapillary (Marangoni) convection is time-dependent even for small zone geometries. This has been demonstrated in several Technische Experimente unter Schwerelosigkeit (TEXUS) - technical experiments under reduced gravity) flights. Thus, to really take advantage of microgravity with respect to improve crystal quality, tools are required to control Marangoni convection in space facilities. Applying magnetic fields, convection can be influenced; fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). In floating zones of 8-10mm diameter and height (Ma approximately equals 6 x 10(exp 3)), a static magnetic field of about 2OOmT is sufficient to suppress time-dependent Marangoni convection to a high degree, but in dependence on the kind and the concentration of the added dopant, a new type of strongly pronounced dopant inhomogeneities have been detected. They are originated by thermoelectromagnetic convection. This can be avoided as well as detrimental effects on the radial dopant distribution by using rotating magnetic fields instead of static ones. Applying 75mT/50Hz to the FZ, the intensity of the dopant fluctuations is reduced to a high degree. Considering the rather low power consumption of rotating magnetic fields, this will be a useful tool for control or elimination of time-dependent Marangoni convection under microgravity. The strong time dependent character of thermocapillary flow and its influence on the temperature field has been measured in silicon half-zones for Marangoni numbers of Ma is approximately equal to 1-1.5 x 10(exp 4): temperature fluctuations up to 4C have been determined. Their frequency range was 0.1 and 0.4 Hz. Between certain thermocouple or sensor pairs, strong correlation has been detected.

Dold, P.↗

Numerical Analysis of Temperature Gradients and Interface Shape During Directional Solidification of Al and Al-Cu Alloy Under Microgravity Conditions

Numerical modeling was undertaken to analyze the influence of radial thermal gradient on solid/liquid interface shape and convection patterns during solidification of pure Al and Al-4 wt. % Cu alloy. Steady state calculations were performed for different gravity levels and orientations. Furthermore, transient modeling was undertaken to investigate effect of the solidification velocity. The furnace configuration used in this analysis is the proposed International Space Station Furnace. Results from a thermal model of the furnace core were used as initial boundary conditions for solidification modeling. The Solidification model was adopted from previous work and was based on the finite element code FIDAP. Thermocouple data and quenched interface shape from a pure Al sample flown on the Life Sciences and Microgravity Spacelab (LMS) mission, July 1996 was used for model validation. Good agreement was obtained between the predicted interface shape and that measured from the quenched LMS sample. It was found that the imposed temperature boundary condition must be sufficiently smooth for the heat fluxes in the model to be self-consistent. The model predicted that alloy sample Al-Cu is more sensitive to variations in the gravity level compared to pure Al. For Al-Cu alloy, solute diffusivity is approximately 10(exp 4) times smaller than thermal diffusivity of pure Al. Hence, in a microgravity environment the weak convection has no measurable effect on the heat fluxes, but is still strong enough to affect concentration distribution. Since the alloy melting temperature is determined by concentration the interface shape depends on the level of convection. This was found not to be the case for pure metal.

Bune, Andris V.↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

Selective Catalytic Combustion Sensors for Reactive Organic Analysis

Sensors involving a vanadia-alumina catalyst bed-thermocouple assembly satisfy requirements for simple, reproducible and rapid continuous analysis or reactive organics. Responses generally increase with temperature to 400 C and increase to a maximum with flow rate/catalyst volume. Selectivity decreases with temperature. Response time decreases with flow rate and increases with catalyst volume. At chosen optimum conditions calculated response which is additive and linear agrees better with photochemical reactivity than other methods for various automotive sources, and response to vehicle exhaust is insensitive to flow rate. Application to measurement of total reactive organics in vehicle exhaust as well as for gas chromatography detection illustrate utility. The approach appears generally applicable to high thermal effect reactions involving first order kinetics.

Innes, W. B.↗

Investigation of Boundary Layer Development in Multi-Stage Low Pressure

A review of recent literature has been made in the areas of unsteady measurement in turbomachinery and LP turbine design. This has included a detailed review of methods for extracting quantitative shear stress data from surface mounted hot-film arrays. Research goals were identified on the basis of the literature survey and following interaction with the GE and NASA contracts. Progress has also been made in the detailed planning of the research program. An array of hot-film sensors has been mounted at mid-span on a second stage nozzle blade ready for installation in the current turbine buildup. A new technique of applying the hot-film array using double sided adhesive is being tested. The temperature in the vicinity of the hot-films will be monitored using a thermocouple attached to the blade pressure surface. This will increase the accuracy of the data reduction process compared with the methods applied by Halstead et at. (1995) and others. Data obtained from this first set of sensors, along with data from the hot-wire investigation will help to determine the best locations for surface hot-film instrumentation for subsequent builds of the turbine. Other LSRT instrumentation issues which have been addressed include calibration of the torque measurement system and procurement of custom design hot-wire sensors required to compensate for the slope flow path. Preliminary attempts at modeling the boundary layer transition process have been completed. A steady, coupled viscous-inviscid flow solver (the MISES code of Drela and Youngren) was used to calculate the steady-flow boundary layer transition location.

Source record↗

Pressure-Sensitive Paint Measurements on Surfaces with Non-Uniform Temperature

Pressure-sensitive paint (PSP) has become a useful tool to augment conventional pressure taps in measuring the surface pressure distribution of aerodynamic components in wind tunnel testing. While the PSP offers the advantage of a non-intrusive global mapping of the surface pressure, one prominent drawback to the accuracy of this technique is the inherent temperature sensitivity of the coating's luminescent intensity. A typical aerodynamic surface PSP test has relied on the coated surface to be both spatially and temporally isothermal, along with conventional instrumentation for an in situ calibration to generate the highest accuracy pressure mappings. In some tests however, spatial and temporal thermal gradients are generated by the nature of the test as in a blowing jet impinging on a surface. In these cases, the temperature variations on the painted surface must be accounted for in order to yield high accuracy and reliable data. A new temperature correction technique was developed at NASA Lewis to collapse a "family" of PSP calibration curves to a single intensity ratio versus pressure curve. This correction allows a streamlined procedure to be followed whether or not temperature information is used in the data reduction of the PSP. This paper explores the use of conventional instrumentation such as thermocouples and pressure taps along with temperature-sensitive paint (TSP) to correct for the thermal gradients that exist in aeropropulsion PSP tests. Temperature corrected PSP measurements for both a supersonic mixer ejector and jet cavity interaction tests are presented.

Bencic, Timothy J.↗

Project Description and Publications List for UAH CMMR

This research combines a state of the art X-ray Transmission Microscope, XTM, with a specially designed x-ray transparent horizontal Bridgman furnace to image (with resolutions up to 3 micrometers) the solidification of metal alloys in real-time. The objective is to obtain real-time dynamic data to provide direct measure of the solute profile in the liquid, phase coalescence and growth in the liquid, and the detailed interface morphology (e,g., dendrites and cells) during solidification. We are also enhancing the XTM data with precise solid-liquid interfacial temperature and the thermal gradient measurement techniques, and working on the application of this technology to the study of the fundamentals of solidification in microgravity. Over the last several years we have successfully imaged in real-time: interfacial-morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid interface. We have also measured true local growth rates and can evaluate segregation structures in the solid. Interfacial undercoolings are being measured either with a special Seebeck furnace or with micro-thermocouple arrays we are developing. These later techniques are presently being incorporated with the XTM furnace. This last year emphasized the investigation of the solute layer in the melt during solidification. Methods were developed to quantify the solute concentrations using x-ray absorption and to compare to predictions from simulations. In addition, work is being completed on a brass-board portable XTM that incorporates a vertical Bridgman furnace.

Kaukler, William F.↗

Growth of Solid Solution Single Crystals

The solidification of a solid solution semiconductor, having a wide separation between liquidus and serious has been extensively studied in ground based, high magnetic field and Spacelab experiments. Two alloys of mercury cadmium telluride have been studied; mercury cadmium telluride with 80.0 mole percent of HgTe and 84.8 mole percent respectively. These alloys are extremely difficult to grow by directional solidification on earth due to high solutal and thermal density differences that give rise to fluid flow and consequent loss of interface shape and composition. Diffusion controlled growth is therefore impossible to achieve in conventional directional solidification. The ground based experiments consisted of growing crystals in several different configurations of heat pipe furnaces, NASA's Advanced Automated Directional Solidification Furnace (AADSF), and a similar furnace incorporated in a superconducting magnet capable of operating at up to 5T. The first microgravity experiment took place during the flight of STS-62 in March 1994, with the AADSF installed on the second United States Microgravity Payload (USMP-2). The alloy was solidified at 3/4 inch per day over a 9 day period, and for the first time a detailed evaluation was performed of residual acceleration effects. The second flight experiment took place in the fourth United States Microgravity Payload Mission (USMP-4) in November 1997. Due to contamination of the furnace system by a previously processed sample, the sample was not received until May 1998, and the preliminary analysis shows that the conditions prevailing during the experiment were quite different from the requirements requested prior to the mission. Early results are indicating that the sample may not accomplish the desired objectives. As with the USMP-2 mission, the results of the ground based experiments were compared with the crystal grown in orbit under microgravity conditions. On the earth, it has been demonstrated that the application of the magnetic field leads to a significant reduction in fluid flow, with improved homogeneity of composition. The field strength required to suppress flow increases with diameter of the material. The 8 mm diameter sample used here was less than the upper diameter limit for a ST magnet. The configuration for USMP-4 was changed so that the material was seeded and other processing techniques were also modified. It was decided to examine the effects of a strong magnetic field under the modified configuration and parameters. A further change from USMP-2 was that a different composition of material was grown, namely with 0.152 mole fraction of cadmium telluride rather than the 0.200 of the USMP-2 experiment. The objective was to grow highly homogeneous, low defect density material of a composition at which the conduction band and the valence band of the material impinge against each other. As indicated, the furnace was contaminated during the mission. As a result of solid debris remaining in the furnace bore, the cartridge in this experiment, denoted as SL1-417, was significantly bent during the insertion phase. During translation the cartridge scraped against the plate which isolates the hot and cold zones of the furnace. Thermocouples indicated that a thermal assymetry resulted. The scraping in the slow translation or crystal growth part of the processing was not smooth and it is probable that the jitter was sufficient to give rise to convection in the melt. Early measurements of composition from the surface of the sample have shown that the composition varies in an oscillatory manner.

Lehoczky, Sandor L.↗

Pegasus(Registered trademark) Wing-Glove Experiment to Document Hypersonic Crossflow Transition: Measurement System and Selected Flight Results

In a recent flight experiment to study hypersonic crossflow transition, boundary layer characteristics were documented. A smooth steel glove was mounted on the first stage delta wing of Orbital Sciences Corporation's Pegasus (R) launch vehicle and was flown at speeds of up to Mach 8 and altitudes of up to 250,000 ft. The wing-glove experiment was flown as a secondary payload off the coast of Florida in October 1998. This paper describes the measurement system developed. Samples of the results obtained for different parts of the trajectory are included to show the characteristics and quality of the data. Thermocouples and pressure sensors (including Preston tubes, Stanton tubes, and a "probeless" pressure rake showing boundary layer profiles) measured the time-averaged flow. Surface hot-films and high-frequency pressure transducers measured flow dynamics. Because the vehicle was not recoverable, it was necessary to design a system for real-time onboard processing and transmission. Onboard processing included spectral averaging. The quality and consistency of data obtained was good and met the experiment requirements.

Bertelrud, Arild↗

NASA GRC's High Pressure Burner Rig Facility and Materials Test Capabilities

The High Pressure Burner Rig (HPBR) at NASA Glenn Research Center is a high-velocity. pressurized combustion test rig used for high-temperature environmental durability studies of advanced materials and components. The facility burns jet fuel and air in controlled ratios, simulating combustion gas chemistries and temperatures that are realistic to those in gas turbine engines. In addition, the test section is capable of simulating the pressures and gas velocities representative of today's aircraft. The HPBR provides a relatively inexpensive. yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials. The facility has the unique capability of operating under both fuel-lean and fuel-rich gas mixtures. using a fume incinerator to eliminate any harmful byproduct emissions (CO, H2S) of rich-burn operation. Test samples are easily accessible for ongoing inspection and documentation of weight change, thickness, cracking, and other metrics. Temperature measurement is available in the form of both thermocouples and optical pyrometery. and the facility is equipped with quartz windows for observation and video taping. Operating conditions include: (1) 1.0 kg/sec (2.0 lbm/sec) combustion and secondary cooling airflow capability: (2) Equivalence ratios of 0.5- 1.0 (lean) to 1.5-2.0 (rich), with typically 10% H2O vapor pressure: (3) Gas temperatures ranging 700-1650 C (1300-3000 F): (4) Test pressures ranging 4-12 atmospheres: (5) Gas flow velocities ranging 10-30 m/s (50-100) ft/sec.: and (6) Cyclic and steady-state exposure capabilities. The facility has historically been used to test coupon-size materials. including metals and ceramics. However complex-shaped components have also been tested including cylinders, airfoils, and film-cooled end walls. The facility has also been used to develop thin-film temperature measurement sensors.

Robinson, R. Craig↗