Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Engineering Challenges of Solution and Slurry-Phase Chemical Hydrogen Storage Materials for Automotive Fuel Cell Applications

In this work, we present the research findings of the DOE-funded Hydrogen Storage Engineering Center of Excellence (HSECoE) related to liquid-phase and slurry-phase chemical hydrogen storage media and their potential as future hydrogen storage media for automotive applications. Chemical hydrogen storage media other than neat liquid compositions will prove difficult to meet the DOE system level targets. Solid- and slurry-phase chemical hydrogen storage media requiring off-board regeneration are impractical and highly unlikely to be implemented for automotive applications because of the formidable task of developing solid- or slurry-phase transport systems that are commercially reliable and economical throughout the entire life cycle of the fuel. Additionally, the regeneration cost and efficiency of chemical hydrogen storage media is currently the single most prohibitive barrier to implementing chemical hydrogen storage media. Ideally, neat liquid-phase chemical hydrogen storage media with net-usable gravimetric hydrogen capacities of greater than 7.8 wt% are projected to meet the 2017 DOE system level gravimetric and volumetric targets. The research presented herein is a collection of research findings that do not in and of themselves warrant a dedicated manuscript. However, the collection of results do, in fact, highlight the engineering challenges and short-comings in scaling up and demonstrating fluid-phase ammonia borane and alane compositions that all future materials researchers working in hydrogen storage should be aware of.

25 ENERGY STORAGE↗

SU-F-T-669: Commissioning of An Electronic Brachytherapy System for Targeted Mouse Irradiation

Purpose: The aim of this study was to commission the Xoft Axxent™ electronic brachytherapy (eBT) source and 10 mm diameter surface applicator with NIST traceability for targeted irradiations of mouse anal carcinomas. Methods: The Xoft Axxent™ electronic brachytherapy (eBT) and 10 mm diameter surface applicator was chosen by the collaborating physician as a radiation delivery mechanism for mouse anal carcinomas. The target dose was 2 Gy at a depth of 3 mm in tissue to be delivered in a single fraction. To implement an accurate and reliable irradiation plan, the system was commissioned by first determining the eBT source output and corresponding dose rate at a depth of 3 mm in tissue. This was determined through parallel-plate ion chamber measurements and published conversion factors. Well-type ionization chamber measurements were used to determine a transfer coefficient, which correlates the measured dose rate at 3 mm to the NIST-traceable quantity, air-kerma rate at 50 cm in air, for eBT sources. By correlating these two quantities, daily monitoring in the well chamber becomes an accurate and efficient quality assurance technique. Once the dose-rate was determined, a treatment recipe was developed and confirmed with chamber measurements to deliver the requested dose. Radiochromic film was used to verify the dose distribution across the field. Results: Dose rates at 3 mm depth in tissue were determined for two different Xoft Axxent™ sources and correlated with NIST-traceable well-type ionization chamber measurements. Unique transfer coefficients were determined for each source and the treatment recipe was validated by measurements. Film profiles showed a uniform dose distribution across the field. Conclusion: A Xoft Axxent™ eBT system was successfully commissioned for use in the irradiation of mouse rectal tumors. Dose rates in tissue were determined as well as other pertinent parameters to ensure accurate delivery of dose to the target region.

60 APPLIED LIFE SCIENCES↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Risk in an Uncertain Future: The Evolution of Resource Adequacy

As our power grids transition toward a decarbonized energy mix, ensuring reliability and provision of grid services remains paramount. The power system has always been heavily influenced by the weather - extreme temperatures determine the timing of peak demand, winter cold snaps can limit natural gas supply, gas turbine reliability and output are affected by ambient conditions, and hydro output varies seasonally and annually. However, as the grid increasingly relies on variable renewable energy (VRE), like wind and solar, the attention to reliability and weather conditions is increasingly important. The implications of changing reliability are large. The Electric Reliability Council of Texas (ERCOT) rolling blackouts from earlier this year impacted millions of people across the state and could be seen from space (Figure 1).

hydraulic turbines↗

Model-Based Approaches to Generate Knowledge from Data in a Plant Reliability Context

One challenge that nuclear power plant system engineers are facing is continuous generation of an extremely large amount of equipment reliability (ER) data. These data elements come in textual (e.g., condition reports) and numeric (e.g., generated by monitoring systems) forms. They provide system engineers with valuable insights and information by discovering anomalous behaviors or degradation trends, identifying possible causes behind such behaviors and trends, and predicting their direct consequences. This paper directly targets the knowledge generation from ER data by putting “data into context.” We employ model-based system engineering (MBSE) of systems and assets to represent and capture their architecture and functional (i.e., cause-effect) relations. ER data elements are processed by first identifying which of the developed MBSE elements they are referring to. This task is harder for textual data since the information contained in issue or maintenance reports needs to be “understood” by a computational tool. We called this process “knowledge extraction” since our methods extract knowledge from textual data. Last, once numeric and textual ER data elements have been processed and “understood,” we discover possible cause-effect relations among them. This is performed by observing whether a logical connection through the MBSE models exists, and if there is a temporal relationship among them. The logic and temporal are the two main ingredients to perform “machine reasoning” from ER data.

97 - MATHEMATICS AND COMPUTING↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy Surety Design Methodology

The Energy Surety Design Methodology (ESDM) provides a systematic approach for engineers and researchers to create a preliminary electric grid design, thus establishing a means to preserve and quickly restore customer-specified critical loads. Over a decade ago, Sandia National Laboratories (Sandia) defined Energy Surety for applications with energy systems to include elements of reliability, security, safety, cost, and environmental impact. Since then, Sandia has employed design concepts of energy surety for over 20 military installations and their interaction with utility systems, including the Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capability Technology Demonstration (JCTD) project. In recent years, resilience has also been added as a key element of energy surety. This methodology document includes both process recommendations and technical guidance, with references to useful tools and analytic approaches at each step of the process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrifying the U.S. Transportation System with the Joint Office

The Joint Office of Energy and Transportation is accelerating an electrified transportation system that is convenient, reliable, affordable, accessible, and equitable. The Joint Office was created under the Bipartisan Infrastructure Law (BIL) to leverage the combined expertise of the U.S. Departments of Energy and Transportation. This is an overview fact sheet describing the Joint Office of Energy and Transportation.

ADVANCED PROPULSION SYSTEMS↗

Assessment of NuScale SMR Steam Heat Augmentation for Chemical Plant Decarbonization

Nearly 50% of the total energy consumed by the industrial sector in the United States is used to produce process steam with natural gas and coal-fired boilers1 . This project conducts a technoeconomic assessment of a NuScale Small Modular Reactor (SMR) coupled with a chemical plant as an Integrated Energy System (IES) where nuclear produces steam and electric power to meet the requirements of a large chemical plant. In a 2020 study, ORNL evaluated the feasibility of using advanced SMRs, including the NuScale design, to supply energy to the Eastman Chemical Plant. However, since that report was published, NuScale received NRC approval for its uprated 77 MWe design with 56% more power and has also introduced a high-temperature, high pressure, steam heat-augmentation system, a key focus of the new study. The new study also benefits from revised capital costs, a 10-day refueling outage time, reduced plant staffing, higher capacity factors, and a site boundary Emergency Planning Zone methodology. The study consists of a techno-economic assessment of two possible energy sources (nuclear and natural gas) in a number of steam and power generation configurations (NuScale Power Modules (NPMs), boilers and combinations of both) to satisfy the steam and power demand with the most reliable and cost competitive system. A total of 2,947.3 klb/hr of steam and 72.5 MWe of electricity are required for the demonstration case. A range of scenarios and solutions are explored, from a 12-NPM plant (3,000 MWth)—with excess capacity and redundancy, capable of supplying a significant amount of extra power to the grid—to a 4-NPM (1,000 MWth) plant—supplemented with existing boilers or grid power for redundancy. The study uses historical steam and power data from a chemical plant and examines the sensitivity to natural gas and grid power cost variations. Scenarios with up to two times gas and electricity costs were considered. Profitability in a 60-year time horizon was analyzed, consistent with NuScale’s design life specification. A steady-state site integration and reliability analysis was performed, and trade-offs were identified.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating Transactive Controls of Integrated Transmission and Distribution Systems using the Framework for Network Co-Simulation

With an ever-evolving power grid, concerns regarding how to maintain system stability, efficiency, and reliability remain constant because of increasing uncertainties and decreasing rotating inertia. To alleviate some of these concerns, demand response represents a viable solution and is virtually an untapped resource in the current power grid. This work describes a hierarchical control framework that allows coordination between distributed energy resources and demand response. This control framework is composed of two control layers: a coordination layer that ensures aggregations of resources are coordinated to achieve system objectives and a device layer that controls individual resources to assure the predetermined power profile is tracked in real time. Large-scale simulations are executed to study the hierarchical control, requiring advancements in simulation capabilities. Technical advancements necessary to investigate and answer control interaction questions, including the Framework for Network Co-Simulation platform and Arion modeling capability, are detailed. Insights into the interdependencies of controls across a complex system and how they must be tuned, as well as validation of the effectiveness of the proposed control framework, are yielded using a large-scale integrated transmission system model coupled with multiple distribution systems.

demand response↗

van der Waals corrected density functionals for cylindrical surfaces: Ammonia and nitrogen dioxide adsorbed on a single-walled carbon nanotube

In this work, we extend the damped Zaremba-Kohn model (dZK) for long-range dispersion interaction between a molecule and a planar surface to molecules adsorbed on a curved cylindrical surface, and employ this extended model as an additive correction to the semilocal density functionals PBE (Perdew-Burke-Ernzerhof) and SCAN (strongly constrained and appropriately normed). The resulting PBE+vdW (van der Waals)-dZK and SCAN+vdW-dZK are applied to two systems, NH3 and NO2 molecules adsorbed on a single-wall carbon nanotube (CNT), for calculations of binding energies and equilibrium distances. For comparison, the results from vdW nonlocal functionals, such as SCAN+rVV10 and PBE+rVV10, are also presented. The binding energies from PBE+rVV10 (Vydrov and Van Voorhis), SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK are about 70–115 meV for the system of CNT + NH 3 and 300–500 meV for the system of CNT + NO 2 . The results from PBE+vdW-dZK and SCAN+vdW-dZK are closer to each other than those from PBE+rVV10 and SCAN+rVV10 are. The relatively closer results from PBE+vdW-dZK and SCAN+vdW-dZK indicate the consistency of our developed vdW–dZK model for cylindrical surfaces. All methods, including PBE, SCAN, PBE+rVV10, SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK, give approximately the same binding energy differences between two adsorption configurations (types I and II) for the two systems. This implies that the two adsorption sites have approximately the same adsorption stability. The exponent of the vdW interaction power law from our vdW-dZK model for the two systems is about 0 at short distance, largely due to the damping factor, and tends slowly to –4 to –4.5 at distances D about 20–50 Å. At even larger distances, the vdW power-law exponent approaches –5. This feature is very similar to the one calculated with random-phase approximation and renormalization group approaches, supporting the applicability of our methods. Our developed vdW-dZK method provides a highly efficient and reliable method for large systems with cylindrical surfaces, such as vdW interactions with nanotubes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

High temporal resolution generation expansion planning for the clean energy transition

As power systems integrate increasing quantities of wind, solar and energy storage resources, it is important to revisit power system capacity expansion modeling methods and assumptions that have been utilized in thermal- dominated systems. We conduct a series of case study analyses using a simplified representation of the Electric Reliability Council of Texas (ERCOT) system to demonstrate how least-cost capacity expansion outcomes are impacted by changes in model resolution across two temporal dimensions: 1) the number of considered representative periods, and 2) the system dispatch interval. First, we find that the least-cost generation portfolio can differ significantly for small changes in the number of representative days, but largely converges to the 365-day result once 104 representative days are considered. Furthermore, systems with wind, solar and storage resources were more sensitive to changes in the number of representative days than a thermal-dominated system. Second, we find that considering five-minute dispatch resolution consistently results in least-cost generation portfolios with less solar capacity and more energy storage capacity than corresponding scenarios with hourly dispatch intervals. This suggests that hourly dispatch representation fails to capture the intra-hour volatility of solar generation, and therefore also overlooks opportunities for storage resources to provide system value by balancing this volatility. Collectively these results indicate that capacity expansion modelers should revisit conventional approaches to temporal representation when conducting analyses of deeply decarbonized power systems to ensure that such analyses are robust and actionable. To our knowledge, this is the first study to analyze capacity expansion outcomes with five-minute dispatch resolution in this manner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large-Scale Data Challenges in Future Power Grids

This paper describes technical challenges in supporting large-scale real-time data analysis for future power grid systems and discusses various design options to address these challenges. Even though the existing U.S. power grid has served the nation remarkably well over the last 120 years, big changes are in the horizon. The widespread deployment of renewable generation, smart grid controls, energy storage, plug-in hybrids, and new conducting materials will require fundamental changes in the operational concepts and principal components. The whole system becomes highly dynamic and needs constant adjustments based on real time data. Even though millions of sensors such as phase measurement units (PMUs) and smart meters are being widely deployed, a data layer that can support this amount of data in real time is needed. Unlike the data fabric in cloud services, the data layer for smart grids must address some unique challenges. This layer must be scalable to support millions of sensors and a large number of diverse applications and still provide real time guarantees. Moreover, the system needs to be highly reliable and highly secure because the power grid is a critical piece of infrastructure. No existing systems can satisfy all the requirements at the same time. We examine various design options. In particular, we explore the special characteristics of power grid data to meet both scalability and quality of service requirements. Our initial prototype can improve performance by orders of magnitude over existing general-purpose systems. The prototype was demonstrated with several use cases from PNNL’s FPGI and was shown to be able to integrate huge amount of data from a large number of sensors and a diverse set of applications.

Smart Grid, Real Time, Commercial Products, Big Da↗

Mini-cell: Compact all optical gas monitoring sensor for persistent surveillance of complex system

Persistent surveillance of complex systems by embedded sensing is the new paradigm of aging awareness and monitoring. In any complex system with a long-term lifespan plan, the persistent surveillance of critical parameters warrants the reliability and safety/security of the system by the continuous monitoring of the state of health and aging conditions. Therefore, embedded sensors of physical, chemical, and structural features/traits are critical for uncovering occurrences of undesired/unexpected events. Gas sensing can provide early detection of a broad range of problems such as decomposing components, corrosion, failures, and leaks. For the application of interest, the sensors must be: 1/highly selective and sensitive for a broad range of gas molecules, 2/compact, 3/minimally invasive, 4/rugged for vibration and thermal excursions, and 5/ environmentally inert.

47 OTHER INSTRUMENTATION↗