Laser Scribing for Electrode Patterning of Perovskite Spectrometer-Grade CsPbBr 3 Gamma-ray Detectors

Making semiconductor radiation detectors that work at room temperature relies heavily on the deposition and pixelation of electrodes. Electrode patterning of perovskite solar cells widely implements laser scribing techniques, which is a convenient, scalable, and inexpensive technique. However, this method has not found its application in radiation detector patterning yet, and the question whether laser scribing can achieve high-quality patterns with minimum damage to a detector crystal and low interpixel cross-talk remains largely unanswered. To prove that laser scribing is a practical method for electrode patterning on perovskite CsPbBr 3 detectors, we use the material to create a variety of patterns. A very low lateral leakage current (60 nA at 10 V) and high mobility-lifetime product (9.7(3) x 10 -4 cm 2 /V) were observed between the pixel and the guard ring in tests of single-pixel devices with a separation of 200 or 100 μm between the central electrode and the guard ring. The 122 and 136 keV photopeaks in 57 Co gamma-ray spectra were very well resolved with an energy resolution of up to 6.1% at 122 keV. Finally, a further reduction in gap size to 50 mu m is conceivable, but more process optimization is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process

Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd 3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd 3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd 3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd 3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd 3+ in different locations within the contactor system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗