Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Source Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

The Effect of Kr-85 Decay to Rb-85 on Waste Forms - 17105

Krypton-85 (Kr-85) is a volatile radionuclide released during the reprocessing of used nuclear fuel (UNF). Prior to discharge of process off-gas streams to the environment, removal of Kr-85 is required to meet emission regulations. Once removed from the off-gas streams, Kr (containing stable Kr in addition to Kr-85) must be placed in storage until the Kr-85 has decayed to levels such that its potential release would meet regulatory guidelines. The current method of storage is high-pressure metal canisters. Historically, concerns have been expressed that the decay product of Kr-85, Rubidium-85 (Rb-85), could cause corrosion and weakening in the canisters that would ultimately lead to premature failure and release of Kr-85. Alternate methods and materials, such as matrix isolation in a vapor deposited metal and immobilization in zeolites, have been investigated as storage approaches for Kr. However, even these storage methods may become compromised due to the chemical effects of Rb-85 arising from the decay of Kr-85. A review was conducted of the available literature to examine topics relevant to the effects of Rb on the long-term storage of Kr-85, examine the source terms in the context of this concern, and suggest a path forward to resolve outstanding knowledge gaps. In the course of this analysis, several knowledge gaps were identified. Examples include: o The use of solid sorbents to potentially permit more Kr-85-bearing gas to be loaded into canisters, either at the pressures used in the current method or at significantly lower pressures. o A cost-to-benefit analysis is needed to ascertain the practicality of manufacturing waste forms for Kr-85 storage with solid sorbents. o The effects of radiation and chemical transmutation in solid sorbents or matrices for this application are virtually unknown. o Fundamental data are needed on corrosion rates and mechanisms as functions of Rb concentration, storage temperature, etc., for various storage approaches (e.g., as compressed gas or encapsulated in a getter material) and storage container materials. The present analysis focused on the available information regarding storage of Kr-85 in high-pressure containers. It was judged unlikely that such containers would be compromised by corrosion from the Rb decay product, especially if the Kr recovery operations result in a gas composition with very low oxygen content. However, this conclusion should be revisited based on preliminary data gathered from analysis of legacy Kr waste forms. These legacy waste forms are a result of experiments conducted at Idaho National Laboratory over 30 y ago and have been stored for more than three Kr-85 half-lives. Evaluation of these forms indicates significant corrosion, the cause of which has not been conclusively determined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of options for the development of a stacked storage complex in the Northern Michigan Basin, USA

The Northern Michigan Basin (NMB) Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Integrated Pre-Feasibility Project is part of the U.S. Department of Energy’s (DOE) CarbonSAFE initiative. Our objective of the NMB CarbonSAFE pre-feasibility project was to assess the feasibility of an integrated, commercial-scale carbon dioxide (CO 2 ) storage complex in the NMB, which includes one or more deep saline geologic formations with sufficient capacity to permanently store at least 50 million metric tons of CO 2 over a 20- to 30-year period. Subsurface injection of CO 2 into depleted oil reservoirs for enhanced oil recovery (EOR) was also evaluated in the pre-feasibility study as an additional geologic storage mechanism because there are hundreds of depleted pinnacle reef reservoirs in the NMB, along with an established CO 2 -EOR operation, a feature that distinguishes this area from most other locations in the United States. Additionally, these reefs are co-located with the most favorable saline formations in the basin – the St. Peter sandstone and the Bass Islands dolomite – making stacked storage a real possibility. The study demonstrates that there are multiple locations in the northern Michigan study area that could support a commercial-scale storage complex with either saline storage or associated storage via CO 2 -EOR in the depleted pinnacle reefs alone (i.e., each storage mechanism has sufficient capacity alone) or via a combination of the two storage mechanisms. The term stacked storage refers to the concept of using both mechanisms together, in the same area, to achieve the required storage capacity. Key sites were identified in the northern part of the southern Michigan Peninsula that had sufficient geologic storage, nearby CO 2 sources, a favorable social and economic setting, and a strong developed team.

58 GEOSCIENCES↗

Oxygen plasma damage to blanket and patterned ultralow-{kappa} surfaces

Oxygen plasma damage to blanket and patterned ultralow-{kappa} (ULK) dielectric surfaces was investigated by examining the effect of plasma species and dielectric materials. Blanket ULK films and patterned structures were treated by O{sub 2} plasma in a remote plasma chamber where the ions and radicals from the plasma source can be separately controlled to study their respective roles in the damage process. The plasma damage was characterized by angle resolved x-ray photoelectron spectroscopy, x-ray reflectivity, and Fourier transform infrared spectroscopy. Studies of the angle dependence of oxygen plasma damage to blanket ULK films indicated that damage by ions was anisotropic while that by radicals was isotropic. Ions were found to play an important role in assisting carbon depletion by oxygen radicals on the blanket film surface. More plasma damage was observed with increasing porosity in ultralow-{kappa} films. Probable reaction paths were proposed by analyzing the reaction by-products. Plasma damage to the sidewall of low-{kappa} trenches was examined by electron energy loss (EELS) analysis. The depletion depth of carbon was found to be related to the penetration of radical species into the porous dielectric and the distribution at the sidewall and trench bottom was affected by the trench pattern geometry, i.e., the aspect ratio, which can be correlated with the electron potential distribution and subsequent trajectory of ions. Vapor silylation was applied for dielectric recovery of trench structure and the result was examined by EELS. The trimethylchlorosilane was found to be effective for recovery of the sidewall carbon loss. The recovery was better for loss induced by radical O{sub 2} than by hybrid O{sub 2} and the difference was attributed to the surface densification by ions limiting the mass transport of vapor chemicals.

36 MATERIALS SCIENCE↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

Efficient 3-D velocity model building using joint inline and crossline plane-wave wave-equation migration velocity analyses

SUMMARY Wave-equation migration velocity analysis (WEMVA) is an image-domain inversion method for velocity model building. Automatic plane-wave WEMVA (PWEMVA) calculates the moveouts of plane-wave common-image gathers (CIGs) by searching a best-fitting parabola with semblance analysis and backprojects residual CIG moveouts into wavefield wave paths with a reflection tomographic kernel. However, 3-D PWEMVA is very computationally expensive because 3-D reflection tomographic inversion requires at least five 3-D reverse-time migrations per iteration and stores two types of source wavefields at model boundaries. We develop a joint inline and crossline PWEMVA method for efficient 3-D velocity model building. We alternatively implement the inline and crossline PWEMVAs with a constraint for each other, in which we iteratively construct the 3-D velocity model update through 1-D spline interpolation of 2-D gradients. The inline and crossline joint inversion is practical since PWEMVA only inverts for low-wavenumber velocity perturbations along wave paths, and the method can take less than 1 per cent of the computational cost of full 3-D PWEMVA. To construct unaliased plane waves for our joint inline and crossline PWEMVA, we develop a 3-D data interpolation method in the frequency–wavenumber (FK) domain to recover regularly and randomly missing traces. The method minimizes the misfit on sufficiently localized data subsets with iterative optimal step lengths and a gradient preconditioner that iteratively selects dominant dips along different azimuths. In numerical experiments, we use a 3-D synthetic seismic data set and a land 3-D field seismic data set acquired at the Farnsworth CO2-EOR (enhanced oil recovery) field to demonstrate the efficacy of our velocity model building and data interpolation methods.

Liu, Xuejian↗

Single-column cryogenic air separation: enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N2-enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde's single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde's single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O2. However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

Cheng, Mao↗

Thermal Removal Of Tritium From Concrete And Soil To Reduce Groundwater Impacts

Legacy heavy-water moderator operations at the Savannah River Site (SRS) have resulted in the contamination of equipment pads, building slabs, and surrounding soil with tritium. At the time of discovery the tritium had impacted the shallow (< 3-m) groundwater at the facility. While tritium was present in the groundwater, characterization efforts determined that a significant source remained in a concrete slab at the surface and within the associated vadose zone soils. To prevent continued long-term impacts to the shallow groundwater a CERCLA non-time critical removal action for these source materials was conducted to reduce the leaching of tritium from the vadose zone soils and concrete slabs. In order to minimize transportation and disposal costs, an on-site thermal treatment process was designed, tested, and implemented. The on-site treatment consisted of thermal detritiation of the concrete rubble and soil. During this process concrete rubble was heated to a temperature of 815 deg C (1,500 deg F) resulting in the dehydration and removal of water bound tritium. During heating, tritium contaminated soil was used to provide thermal insulation during which it&#x27;s temperature exceeded 100 deg C (212 deg F), causing drying and removal of tritium. The thermal treatment process volatiles the water bound tritium and releases it to the atmosphere. The released tritium was considered insignificant based upon Clean Air Act Compliance Package (CAP88) analysis and did not exceed exposure thresholds. A treatability study evaluated the effectiveness of this thermal configuration and viability as a decontamination method for tritium in concrete and soil materials. Post treatment sampling confirmed the effectiveness at reducing tritium to acceptable waste site specific levels. With American Recovery and Reinvestment Act (ARRA) funding three additional treatment cells were assembled utilizing commercial heating equipment and common construction materials. This provided a total of four units to batch treat concrete rubble and soil. Post treatment sampling verified that the activity in the treated soil and concrete met the treatment standards for each medium which allowed the treated concrete rubble and soil to be disposed of on site as backfill. During testing and operations a total of 1,261-m{sup 3} (1,650-yd{sup 3}) of contaminated concrete and soils were treated with an actual incurred cost of $3,980,000. This represents a unit treatment cost of $3,156/m{sup 3} ($2,412/yd{sup 3}). In 2011 the project was recognized with an e-Star Sustainability Award by DOE&#x27;s Office of Environmental Management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Removal of Tritium from Concrete and Soil to Reduce Groundwater Impacts - 13197

Legacy heavy-water moderator operations at the Savannah River Site (SRS) have resulted in the contamination of equipment pads, building slabs, and surrounding soil with tritium. At the time of discovery the tritium had impacted the shallow (< 3-m) groundwater at the facility. While tritium was present in the groundwater, characterization efforts determined that a significant source remained in a concrete slab at the surface and within the associated vadose zone soils. To prevent continued long-term impacts to the shallow groundwater a CERCLA non-time critical removal action for these source materials was conducted to reduce the leaching of tritium from the vadose zone soils and concrete slabs. In order to minimize transportation and disposal costs, an on-site thermal treatment process was designed, tested, and implemented. The on-site treatment consisted of thermal detritiation of the concrete rubble and soil. During this process concrete rubble was heated to a temperature of 815 deg. C (1,500 deg. F) resulting in the dehydration and removal of water bound tritium. During heating, tritium contaminated soil was used to provide thermal insulation during which it's temperature exceeded 100 deg. C (212 deg. F), causing drying and removal of tritium. The thermal treatment process volatiles the water bound tritium and releases it to the atmosphere. The released tritium was considered insignificant based upon Clean Air Act Compliance Package (CAP88) analysis and did not exceed exposure thresholds. A treatability study evaluated the effectiveness of this thermal configuration and viability as a decontamination method for tritium in concrete and soil materials. Post treatment sampling confirmed the effectiveness at reducing tritium to acceptable waste site specific levels. With American Recovery and Reinvestment Act (ARRA) funding three additional treatment cells were assembled utilizing commercial heating equipment and common construction materials. This provided a total of four units to batch treat concrete rubble and soil. Post treatment sampling verified that the activity in the treated soil and concrete met the treatment standards for each medium which allowed the treated concrete rubble and soil to be disposed of on-site as backfill. During testing and operations a total of 1,261-m{sup 3} (1,650-yd{sup 3}) of contaminated concrete and soils were treated with an actual incurred cost of $3,980,000. This represents a unit treatment cost of $3,156/m{sup 3} ($2,412/yd{sup 3}). In 2011 the project was recognized with an e-Star Sustainability Award by DOE's Office of Environmental Management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

CO2 interaction with geomaterials.

This work compares the sorption and swelling processes associated with CO2-coal and CO2-clay interactions. We investigated the mechanisms of interaction related to CO2 adsortion in micropores, intercalation into sub-micropores, dissolution in solid matrix, the role of water, and the associated changes in reservoir permeability, for applications in CO2 sequestration and enhanced coal bed methane recovery. The structural changes caused by CO2 have been investigated. A high-pressure micro-dilatometer was equipped to investigate the effect of CO2 pressure on the thermoplastic properties of coal. Using an identical dilatometer, Rashid Khan (1985) performed experiments with CO2 that revealed a dramatic reduction in the softening temperature of coal when exposed to high-pressure CO2. A set of experiments was designed for -20+45-mesh samples of Argonne Premium Pocahontas No.3 coal, which is similar in proximate and ultimate analysis to the Lower Kittanning seam coal that Khan used in his experiments. No dramatic decrease in coal softening temperature has been observed in high-pressure CO2 that would corroborate the prior work of Khan. Thus, conventional polymer (or 'geopolymer') theories may not be directly applicable to CO2 interaction with coals. Clays are similar to coals in that they represent abundant geomaterials with well-developed microporous structure. We evaluated the CO2 sequestration potential of clays relative to coals and investigated the factors that affect the sorption capacity, rates, and permanence of CO2 trapping. For the geomaterials comparison studies, we used source clay samples from The Clay Minerals Society. Preliminary results showed that expandable clays have CO2 sorption capacities comparable to those of coal. We analyzed sorption isotherms, XRD, DRIFTS (infrared reflectance spectra at non-ambient conditions), and TGA-MS (thermal gravimetric analysis) data to compare the effects of various factors on CO2 trapping. In montmorillonite, CO2 molecules may remain trapped for several months following several hours of exposure to high pressure (supercritical conditions), high temperature (above boiling point of water) or both. Such trapping is well preserved in either inert gas or the ambient environment and appears to eventually result in carbonate formation. We performed computer simulations of CO2 interaction with free cations (normal modes of CO2 and Na+CO2 were calculated using B3LYP / aug-cc-pVDZ and MP2 / aug-cc-pVDZ methods) and with clay structures containing interlayer cations (MD simulations with Clayff potentials for clay and a modified CO2 potential). Additionally, interaction of CO2 with hydrated Na-montmorillonite was studied using density functional theory with dispersion corrections. The sorption energies and the swelling behavior were investigated. Preliminary modeling results and experimental observations indicate that the presence of water molecules in the interlayer region is necessary for intercalation of CO2. Our preliminary conclusion is that CO2 molecules may intercalate into interlayer region of swelling clay and stay there via coordination to the interlayer cations.

01 COAL, LIGNITE, AND PEAT↗

Boil-off losses along LH2 pathway

Losses along the LH 2 pathway are intrinsic to the utilization of a cryogenic fluid. They occur when the molecule is transferred between 2 vessels (liquefaction plant to trailer, trailer to station storage, station storage to pump or compressor, then fuel cell electric vehicles …) and when the fluid is warmed up due to heat transfer with the environment. Those losses can be estimated with good accuracy using thermodynamic models based on conservation of mass and energy, providing the thermodynamic states are correctly described. Indeed, the fluid undergoes various changes as it moves along the entire pathway (2 phase transition, super-heated warming, non-uniform temperature distributions across the saturation film) and accurate equations of state and 2 phase behavior implementations are essential. The balances of mass and energy during the various dynamics processes then enable to quantify the boil-off losses. In this work, a MATLAB code previously developed by NASA to simulate rocket loading is used as the basis for the LH 2 transfer model. This code implements complex physical phenomena such as the competition between condensation and evaporation and the convection vs. conduction heat transfer as a function of the relative temperatures on both sides of the saturated film. The original code was modified to consider real gas equations of state, and some semi-empirical relationships, such as between the heat of vaporization and the critical temperature, were also replaced by a REFPROP equivalent expression, assumed to be more accurate. Non-constant liquid temperature equations were added to simulate sub-cooled conditions. It is shown that although trailer depressurization and transfer losses from the receiving vessel during a LH 2 delivery may constitute the largest sources of losses, those can be greatly reduced and even eliminated if CFR/DOT regulations are properly applied and if no-vent fill methods are implemented, particularly for a stationary LH2 storage operating at reasonably low pressure (45 psia or so). As such, it is expected that the only remaining boil-off losses for a refueling station would come from the LH 2 pump (utilization and idling), pump vessel cool down/warm up, and environment heat transfer. Based on experimental data measured at LLNL on the Linde 875 bar LH 2 cryo-pump and results from the model, and extrapolating for refueling stations of various sizes, it can be shown that boil-off losses can vary from 15% of delivered LH 2 for a 100 kg/day, 5% at 400 kg/day, and down to less than 2% for stations above 1,800 kg/day (for a system similar to the one at LLNL). Less boil-off is to be expected for LH 2 pumps dispensing at 350 bar, so that less than 0.7% can be expected above 1,800 kg/day station capacities. At last, boil-off recovery solutions are briefly analyzed, including compressors, cryo-coolers and stationary fuel cell. Their economic value is strongly related to the costs of H2 and of the electricity needed to perform the recovery, on top of the initial capital expenditures. Effective boil-off could be reduced to 0.6-1% for a 2,000 kg/day station if adequate recovery solutions are used.

08 HYDROGEN↗

Findings on subtask 3.3 – applicability of automated brine chemistry determinations for treatment and recovery processes through facility automation/modularization: engineering design study

Under the Energy & Environmental Research Center’s (EERC’s) ~$\$$22 million Phase II Brine Extraction and Storage Test (BEST) Program, a multimillion-dollar brine treatment technology test bed facility was established in western North Dakota to provide a platform for evaluating developing technologies and approaches for brine treatment and volume reduction. The initial facility, and associated research effort, was funded by the U.S. Department of Energy (DOE), with in-kind contributions provided by several industry participants and the state of North Dakota. Since its opening, the Brine Technology Test Facility (BTTF) has supported performance evaluations of desalination technologies capable of treating high-salinity produced water (PW) and enabled data collection for multiple approaches of PW management and critical material recovery. As part of the decommissioning process for the original project, facility ownership and liability were transferred to Select Water, which is providing the EERC with a continuing site access option for state or federal research and/or commercial technology development. This report documents the findings from a design study conducted by the EERC and the engineering firm that was originally contracted to design and construct the facility (Advanced Engineering and Environmental Services, LLC [AE2S]) that evaluated the current status of BTTF and its systems and developed a retrofit design to increase the facility’s capabilities through automation and modularization of its PW treatment infrastructure. The proposed retrofit will provide DOE and industry with an expanded range of conditioned PW that can be produced at the facility for evaluating fit-for-purpose water treatment technologies, online instrumentation for brine chemistry determination, and systems that recover critical materials like lithium and magnesium. The current facility consists of an 9600-square-foot facility that includes a 40-foot by 65-foot Class 1, Division 2-rated demonstration area and associated control rooms and lab-ready space capable of sourcing oil and gas PW and wastewater from industrial sources or tailoring brine compositions up to 300,000 mg/L total dissolved solids (TDS) and supplying them at rates up to 25 gpm for extended-duration technology demonstrations. The colocation of the facility with Select Water’s water management facilities allows for access and unloading of more than 10,000 bbl/day of trucked water delivered to site and associated access to on-site Class I and Class II brine disposal wells and nearby hazardous waste landfills operated and/or contracted by Select Water to dispose of concentrate and/or effluents associated with the testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilizing geothermal heat for hydrothermal liquefaction of algae

The distribution of utilizable geothermal reservoirs in the US is concentrated in areas of low population density. In order to increase the scale of geothermal operations, we proposed to develop a modular biofuel production facility that directly uses geothermal heat. By transforming geothermal heat to chemical potential energy (rather than electricity), the scale of existing or new geothermal operations can be increased and distributed to areas of higher population density. Simultaneously, the economics of producing biocrude oil is improved significantly where geothermal heat is used, instead of natural gas-fired systems for providing heat and power. In the Phase I project, we demonstrated that it was economically feasible to sustainably produce a biofuel by integrating geothermal heat. It was found that, for the best case scenario at a scale of 10T(biomass)/hr, it was possible to produce a biofuel for $0.26/L, as compared to crude oil at $0.3/L (current selling price). Ultimately this demonstrates that this technology can be economically sustainable when integrated with geothermal heat. We also demonstrated that the addition of modular biofuel-production technologies can be more profitable for a geothermal plant operator. For 1000kg/day scale, it was found that it could be 2.5 times more profitable for a geothermal plant operator to sell bio-oil rather than electricity (with a waste source within 20 miles of the processing facility). Furthermore, as the design of the proposed technology recycles significant heat, requiring between 5% and 20% of the total heat load of the biofuel process to be supplied by the geothermal plant, it is feasible for an operator to initially implement the technology at small scale (i.e. less than 100gal/day) with the plans of scaling up operations in the future. Implementing the technology incrementally may minimize initial the investment and financial risk for the operator. Finally, in the Phase I project, we built and tested a hydrothermal system developed at ARI. We tested three different feedstock types, pure algae feed, algae mixed with manure, and algae with in-situ catalysts (molybdenum trioxide), over a range of temperatures and residence times. In terms of oil products, our results (yield, process times and elemental balance) were similar to what was obtained at PNNL. As such our experiments matched well with the techno-economic design (mass throughput specifications), and will thus well inform the Phase II process design. The experimental data obtained on the hydrothermal treatment of algae indicated that the highest recovery of oil occurred at 250°C. This shows that HTL can be carried out 100°C lower than what is currently considered ‘state of the art’, and thus save significant energy savings. Further, it was found that oil-recovered fractions had lower amounts of nitrogen at lower temperatures, indicating that oil produced at 250°C is of higher quality than if we were to produce fuel at 350°C.

09 BIOMASS FUELS↗

Seismic Monitoring at the Underground Nuclear Research Laboratory in Mol, Belgium - 12461

Micro-seismic piezoelectric transmitters installed in the Boom Clay at HADES produce predominantly high frequency signals, above 5 kHz, which favour the generation of P waves. However, above 5 kHz shear (S) waves are not detected by the installation. Recent studies at HADES indicate that it is possible to detect S waves with the current setup when applying a low (5 kHz) cut-off filter. The results also show that S waves have frequencies mainly below 1 kHz, while P waves are detectable at all of the eight transmitted frequencies but show optimum resolution in the range of 7 to 23 kHz. Although the system offers great potential for monitoring the evolution of a geological disposal site, further improvements in signal generation and treatment are necessary. One of these includes the design and testing of a new S-wave source at HADES planned in the framework of the EC MoDeRn project (http://www.modern-fp7.eu/). The seismic installation at HADES continues to provide useful information on the changing properties of the Boom Clay in the near and far field around the PRACLAY gallery since its start of operation in 2006. In the future, the system will also monitor the PRACLAY heater experiment that will start in 2012 and go on for 10 years. So far, the results of long term seismic monitoring show that S waves contain frequencies mainly below 1 kHz. The P waves are detectable at all of the eight transmitted frequencies but show optimum resolution in the range of 7 to 23 kHz. To improve the signal-to-noise ratio and detection of S waves at HADES it is, therefore, necessary to apply a strong low-pass filter that matches the S-wave frequency content. Due to the different frequency ranges observed for the P and S waves, it is recommended to treat them separately. The evolution of both P and S wave velocities in the EDZ around the PRACLAY gallery show continued recovery since its construction in 2007. Modelling results of the variation in crack density obtained from the inversion of the modelled P-wave transmission velocities further confirm the recovery of the EDZ and the self-healing properties of the Boom Clay. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsurface Sources of CO 2 in the Contiguous United States. Volume 1: Discovered Reservoirs

Twenty-one CO 2 fields in the contiguous states contain an estimated 311 Tcf of CO 2 gas-initially-in-place (GIIP). Of that, 168 Tcf (54 percent) is estimated to be accessible and technically recoverable. The estimated economically recoverable resource (ERR) is 96.4 Tcf, based on a CO 2 price of 1.06 $/mcf ($20/tonne) at the field gate. Cumulative production to date is 18.9 Tcf, leaving 77.5 Tcf remaining or net ERR. The Big Piney-LaBarge field in Wyoming contains an estimated net ERR of 52 Tcf, 67 percent of the total for the United States. The remaining ERR in reservoirs that feed into the Permian Basin and Gulf Coast is on the order of 10-20 years of supply.

03 NATURAL GAS↗

Pore size effect on selective gas transport in shale nanopores

In shale gas production, gas composition may vary over time. To understand this phenomenon, we use molecular dynamics simulations to study the permeation of CH 4 , C 2 H 6 and their mixture from a source container through a pyrophyllite nanopore driven by a pressure gradient. For a pure gas, the flow rate of CH 4 is always higher than that of C 2 H 6 , regardless of pore size. For a 1:1 C 2 H 6 : CH 4 mixture, however, C 2 H 6 :CH 4 flow rate ratio is higher than the compositional ratio in the container (i.e., 1:1) when the pore size is smaller than ~1.8 nm. The selective transport is caused by the competitive adsorption of C 2 H 6 over CH 4 in the nanopore. The selectivity is also determined by the interplay between the surface diffusion of the adsorbed molecules and the viscous flow in the center of the pore, and it diminishes as the viscous flow becomes to dominate the surface diffusion when the pore size becomes larger than 1.8 nm. Our work shows that compositional differentiation of shale gas in production is a consequence of nanopore confinement and therefore a key characteristic of an unconventional reservoir. Finally, the related compositional information can potentially be used for monitoring the status of a production well such as its recovery rate.

03 NATURAL GAS↗

Insights into Waterflooding in Hydrocarbon-Bearing Nanochannels of Varying Cross Sections from Mesoscopic Multiphase Flow Simulations

Waterflooding is one of the geotechnique used to recover fuel sources from nanoporous geological formations. The scientific understanding of the process that involves the multiphase flow of nanoconfined fluids, however, has lagged, mainly due to the complex nanopore geometries and chemical compositions. To enable benchmarked flow of nanoconfined fluids, the architected geomaterials, such as synthesized mesoporous silica with tunable pore shapes and surface chemical properties, are used for designing and conducting experiments and simulations. This work uses a modified many-body dissipative particle dynamics (mDPD) model with accurately calibrated parameters to perform parametric flow simulations for studying the influences of waterflooding driven power, pore shape, surface roughness, and surface wettability on the multiphase flow in heptane-saturated silica nanochannels. Remarkably, up to 80\% reduction in the effective permeability is found for water-driven heptane flow in a baseline 4.5 nm-wide slit channel, when compared with the Hagen–Poiseuille equation. In the 4.5 nm-wide channels with architected surface roughness, the flow rate is found either higher or lower than the baseline case, depending on the shape and size of cross-sections. High wettability of the solid surface to water is essential for achieving high recovery of heptane, regardless of surface roughness. When the solid surface is less wetting or non-wetting to water, the existence of an optimal waterflooding driven power is found to allow for the highest possible recovery. A detailed analysis on the evolution of the transient water-heptane interface in those nanochannels is presented to elucidate the underlying mechanisms that impact or dictate the multiphase flow behaviors.

58 GEOSCIENCES↗