Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Optimal Complementarity Analysis of Potential Floating Solar Co-Located With Existing Hydropower Assets Across the Contiguous United States

The U.S. is expected to double its rate of renewable capacity from 2024 to 2030. However, the stochastic nature of renewable energy poses challenges to the operation and reliability of our power grid. The combined generation from renewable energy sources, with dispatchable sources (such as hydropower) operating as a hybrid energy plant, could mitigate this variability. In this paper, the complementarity analysis of selected U.S. reservoirs with existing hydropower assets (EHAs) and potential floating photovoltaics (FPVs) is conducted for the continuous U.S. (CONUS). The optimal FPV capacity for each site is determined by minimizing the variability of the combined output, while adhering to the FPV potential. Our results indicate that over 50% of the analyzed reservoirs achieve a stability coefficient exceeding 0.5, leading to a less-variable output after optimization. Finally, we analyze the complementary hydro-FPV hybrid reservoirs by considering both the Pearson correlation coefficient and the stability coefficient on daily, monthly, and yearly scales. Summaries are included of locations of theoretical FPVs co-located with hydropower plants that exhibit high complementarity based on the selected metrics.

13 - HYDRO ENERGY↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.

array↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

High-Efficiency, Low-Cost III-V Solar Cells by Dynamic Hydride Vapor Phase Epitaxy Coupled with Rapid, Polishing-Free Wafer Reuse through Orientation-Optimized (110) Spalling

We demonstrated (110) GaAs solar cells grown by D-HVPE with equivalent performance and material quality relative to (100) devices. Also, we developed a procedure for repeatable wafer-scale spalling of (110) GaAs. Spalled surfaces were free of the facets founds in (100) GaAs spalling, the large arrest lines found in (100) Ge spalling, and surface features greater than 3 µm in peak-to-valley height, which can otherwise degrade the efficiency of regrown III-V devices. A sub-µm step-terrace morphology was discovered on the post-spall wafer surface, resulting from the restricted cleavage system of GaAs, but we developed understanding of the factors that determine the resulting morphology, enabling ample opportunity for optimization of morphologies suitable for device growth and spall depth waste minimization on (110) GaAs. Lastly, we demonstrated a device grown on a previously spalled surface with only 8% relative efficiency difference to a cell grown on a new unspalled wafer. Significant optimization of the substrate regrowth conditions are required to enable higher efficiency, but these results highlight the promise of (110)-oriented devices coupled with substrate reuse by spalling as a pathway for low-cost III-V photovoltaics.

14 SOLAR ENERGY↗

A Data-Driven Approach to Real-World Degradation of Backsheets

The objectives of this project are as follows: • The population behavior of fielded modules in various conditions of use • Predictions of materials in specific climatic zones • Understanding of a module’s local environment in the field on its degradation It aims to understand how and what backsheet materials of photovoltaic modules degrade in the real world field. • Field Survey Protocol This project is started from the protocol, because all the data, information, domain knowledge are from experience of the real world field surveys, which is based on the protocol. The Protocol is explored from the experience of the field survey observations. With the increasing of the field surveys, it is refined for three versions, which are Task 1.0 (Section 3.1), Task 6.0 (Section 3.6), Task 10.0 (Section 3.10) respectively. It includes a document and a training video, which is able to direct other teams to follow the same procedure with the sites surveyed during this project. The documents include the detailed information but is not limited to the terminology definition, instruments SOP, preparation items for the surveys, form for the data collections, the order of the information collection. The final version of the protocol can be found at Appendix A, see Section 5. Additional, It can also be found at Open Science Framework (OSF), see Section 3.18 for detail. • Written Waiver Request Before staring the field surveys, the request of the waiver for international surveys is completed, because the limitation of climate zone in the United States, see Appendix B in Section 6 for the request documents. Unfortunately, only 1 international site from Taiwan, China can be finished, due to the COVID-19. • Field Survey According to the protocol we built in Section 3.1, 3.6 and 3.10, 41 sites have been surveyed across seven different climate zones (Cfa, Csa, Csb, BSk, Dfa, Dfb, Am). A variety of materials, including Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), Polyvinyl Fluoride (PVF), Polyvinylidene Fluoride (PVDF), Acrylic PVDF, Fluoroethylene Vinyl Ether (FEVE), and Glass, were identified. These sites are located in various states including California, South Carolina, New Mexico, Maryland, Ohio, Tennessee, Florida, Massachusetts, Illinois, Minnesota, Oregon, Colorado, and Taiwan, Republic of China. The ages of the sites ranged from 2 - 38 years in service and the field size varied from 1 MW - 25 MW. All requirements for the modeling have been satisfied. Some observations like ’Edge Effect’ for the rows and Junction box heating will also be a useful knowledge to build the model. Section 3.7 provides detailed information on the sites visited during this reporting period.

14 SOLAR ENERGY↗

Controlled Dielectric Breakdown to Form Pinhole Passivated Contacts

This contribution explores a low-temperature route to forming dielectric pinholes to form poly-Si/dielectric/c-Si passivated contacts. The method utilizes controlled dielectric breakdown to form nanoscale pinholes in a thick (non-tunnelling) dielectric which, when annealed, allows dopant atoms to pass from doped poly-Si through the dielectric and into the c-Si wafer forming conductive pathways. We show that the pinholes can be repassivated with dopants and H diffusion which results in increased PL signals after processing. The method can be expanded to optimized dielectric passivation stacks (not just a single layer) and can be formed in parallel over the faces of the wafer in selected areas (only under the grid).

controlled dielectric breakdown↗

Hydrogen Transport from Dielectrics to poly-Si/SiOx Passivating Contacts Measured by Mass Spectrometry and Vibrational Spectroscopy

We demonstrate the relationship between Si solar cell passivation and hydrogen content of various passivating films, including hydrogenated amorphous silicon (a-Si:H), aluminum oxide (Al2O3), silicon nitride (SiNx) and combinations thereof. Through isotopic studies using quadrupole mass spectrometry (QMS), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy, we determine how hydrogen content and stability within each type of film relates to final passivation quality of solar cell test structures. Si solar cells using polycrystalline silicon on silicon oxide (poly-Si/SiOx) passivating contacts are at the forefront of Si solar cell research and emerging as top performers within industrial production. Performance of passivating contact Si solar cells is largely determined by a parameter known as the open-circuit voltage Voc, which directly relates to material quality within the bulk of the device and at surfaces. High Voc is achieved when defects within the bulk crystalline silicon (c-Si) and at interfaces are passivated, preventing them from acting as charge carrier recombination centers. One of the most important means of passivating defects within Si solar cells is via hydrogenation, injecting the cells with large amounts of H to satisfy dangling bonds in the bulk and at interfaces. Hydrogen is especially important in deactivating a prevalent defect in industrial p-type devices which leads to decreased device performance over long-term exposure to light, called light-induced degradation (LID). Some of the most common materials used to supply H to devices are a-Si:H, Al2O3, and SiNx, which can contain very large amounts of H. Upon annealing at elevated temperatures, the hydrogen becomes mobile enough to find and disable defect sites. However, too much hydrogen can also be problematic, sometimes leading to an effect called light and elevated temperature induced degradation (LeTID). It has been shown that these films passivate the interfaces of poly-Si passivating contacts differently, leading to differing performance. Though Al2O3 is a well-defined dielectric material, SiNx can have many different values of x depending on precursor gases and deposition conditions. We observe different FTIR and Raman spectra from different SiNx over a range of x values films to determine the bonding environments within them and further correlate the relative concentrations of Si, N, and H to the stability of H within SiNx and the passivation performance of each film. Because deuterium is chemically identical to hydrogen within these systems, but gives different signals in FTIR and Raman spectroscopy as well as in QMS, isotopic substitution can be used as an excellent tool to probe the H within films. In addition to measuring the H and D bonding within films using FTIR and Raman spectroscopy, we will use such isotopic experiments to observe H and D movement out of these hydrogenating films at elevated temperatures using QMS to determine the stability of H bonding within such systems. With these films characterized based on elemental composition, we will relate such measurements to passivation quality of these films and combinations thereof on poly-Si/SiOx contact structures using quasi-steady state photoconductance decay measurements to obtain implied open-circuit voltage (iVoc) and saturation current density J0 values. Such investigations into the performance of different passivating films and film stacks will lead to greater understanding of dielectrics in semiconductor devices, further improvements in passivated contact design, and eventually, greater proliferation of renewable solar energy worldwide.

Al2O3↗

Relating Aerial Infrared Thermography Defects to Photovoltaic Performance: Preprint

In this research, we examine the relationship between aerial IR defect analysis and photovoltaic (PV) performance data for twelve utility- and commercial-scale solar sites in the United States. To do this, we fuse the site diagram geoJSON's, aerial infrared thermography (aIRT) defect analyses, and associated inverter time series, allowing for a direct comparison between site defects and time series data. Defect analyses were provided by Zeitview, under its Solar Insights platform. Following the data fusion process, we look at the relationship between system performance and aIRT defects. We investigate the relationship between degradation and hotspot defects, as well as the relationship between AC power data and offline strings and misaligned modules. In general, system degradation was not affected by long-term or balance-of-system (BoS) defects as they occurred infrequently in the data set. However, for one system, a near statistically significant relationship (p-value=0.057) was found when comparing the degradation of inverter blocks with several multi-hotspot defects to all other inverter blocks without this particular defect. There was strong alignment when comparing short-term recoverable module defects such as stuck trackers and offline strings to time series data. In general, we found that when an inverter block has more than 80% of modules flagged for one of these defects, its AC power time data is flat-lined and the inverter block is not producing.

aerial inspection↗

The Solar Curtailment Paradox

This presentation summarizes work recently published in a Joule article, "The Curtailment Paradox in the Transition to High Solar Power Systems." Rising penetrations of variable renewable energy (VRE) in power systems are expected to increase the curtailment of these resources because of oversupply and operational constraints. We evaluate the effect on curtailment from various flexibility approaches, including storage, thermal generator flexibility, operating reserve eligibility rules, transmission constraints, and temporal resolution, by using a highly resolved realistic system. Results reveal two aspects of a curtailment paradox as the system evolves to higher solar penetration levels. First, thermal generator parameters, especially in restricting minimum operating levels and ramp rates, affect VRE curtailment more in mid-PV penetration levels (~25%–40%) but much less at lower (~20%) or higher (~45%) PV penetration levels. Second, although allowing VRE and storage to provide operating reserve results in significant operating costs and curtailment benefits, the price suppression effect from these resources reduces incentives for PV to provide operating reserves with curtailed energy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Improving Solar and Solar+Storage Screening Techniques to Reduce Utility Interconnection Time and Costs (Final Technical Report)

Residential PV installations have increased rapidly over the last decade, and the increased application volume has caused permitting delays and lower overall adoption rates. In this project, we developed and evaluated whether data-driven secondary modeling and screening techniques can help utilities assess customer applications more accurately than traditional screening shortcuts. Secondary topologies are predicted using decision trees and commonly available information, such as service transformer, customer, and street locations. Conductors were predicted using a logistic regression method based on real world object (RWO) types, service transformer ratings, conductor length, and distance to transformer. After developing the combined primary and secondary distribution network model, hosting capacity results were used to train a random forest model to predict the pass/fail likelihood of a customer application. Powerflow based models with predicted secondaries and data-driven methods both increased the screening success rate, relative to common utility heuristics, by as much as 55 percentage points. Data-driven screening techniques were described by one utility as a "right-sized" approach for residential customers given the low-risk of small errors and the high-cost of accurate modeling.

14 SOLAR ENERGY↗

Cross-Cutting Metrology Tools for In Operando Characterization of Carrier Dynamics in Photovoltaic Devices (Final Technical Report)

Understanding the nature of recombination and its dependence on defects and interfaces is essential for engineering materials and contacts for higher V oc and photovoltaic (PV) efficiency. Time-resolved photoluminescence (TRPL) has conventionally been used to evaluate recombination, but not all materials are strongly emissive or otherwise suitable. Time-resolved terahertz spectroscopy is a pump – probe method that presents valuable complementary information, wherein an optical pump pulse photoexcites carriers within the absorber and the transient photoconductivity is probed with a terahertz pulse. Until now, experimental constraints have prohibited the use of terahertz probes to interrogate full device stacks, and measurements were instead made on exfoliated films or films grown on unconventional substrates. However, interfaces are critical to the behavior of photoexcited carriers in solar cells, and the substrates themselves often influence the film growth and bulk properties. Therefore, it is important to probe the behavior of PV absorbers as close as possible to their normal operating conditions. Here we have developed cross-cutting metrology that enable in operando characterization of carrier dynamics and recombination mechanisms in working PV devices. Through a combination of complementary non-contact TRTS and TRPL experiments and modeling, we have obtained key parameters including photoexcited carrier bulk lifetime and interface and back surface recombination velocities with greater precision and accuracy than can be achieved with conventional TRPL alone. By varying pulsed photoexcitation conditions, the contributions of interface and bulk recombination mechanisms can be determined. We have developed and refined this characterization approach by investigating CdTe PVs, which is a well-established technology but with significant margin for further improvements in efficiency. Results were published in Journal of Applied Physics (DOI: 10.1063/5.0064730) and Proceedings of the IEEE PVSC (DOI: 10.1109/PVSC43889.2021.9518559). After validating the approach, we have applied it to correlate recombination rates to processing conditions and material properties, including composition and defects as well as interfaces and surface treatments. Such feedback can inform processing and design choices to enable higher PV efficiency, not only for CdTe, but also CdSe x Te 1-x , CIGS, perovskites, kesterites, and future technologies. A perspective on predicting solar cell performance from terahertz spectroscopy was published in Advanced Energy Materials (DOI: 10.1002/aenm.202102776). The cross-cutting metrology tools developed here will enable determination of the locus and mechanism of performance-limiting recombination in thin film PV devices. This feedback can guide the engineering of PV devices with higher V oc and efficiency, thereby leading to reductions in levelized cost of electricity to meet the SunShot 2030 target of $0.03/kWh for utility-scale PV. Lower costs will enable rapid expansion of renewable electricity generation that is nearly free of carbon emissions. Reducing carbon emissions of the electricity sector is one of the most important solutions to climate change. The project’s specific focus on CdTe PV can benefit First Solar, the US company that is the global leader in CdTe technology, through both technology and workforce development.

14 SOLAR ENERGY↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗

Perovskite Photovoltaic Devices with Carbon-Based Electrodes Withstanding Reverse-Bias Voltages up to –9 V and Surpassing IEC 61215:2016 International Standard

One of the key challenges of perovskite photovoltaics (PV) is the long-term stability. Although efforts are made to improve the lifetime of perovskite PV devices, their degradation under reverse-bias conditions is barely addressed. Herein, perovskite solar cells with carbon-based electrodes are presented which demonstrate superior resilience against reverse-bias-induced degradation. Although their breakdown voltage is identified to be at approximately -3.6 V, cells do not degrade until the applied reverse-bias exceeds -9 V. Two main degradation mechanisms are identified: 1) iodine loss due to hole tunneling into perovskite, which takes place even at low reverse-bias but decomposes the perovskite only after long time durations; and 2) rapid heating at large reverse-bias leading to formation of PbI2, which starts at shunts and then follows the path of the least resistance for the cell current, which is primarily influenced by the electrode sheet resistances. Finally, perovskite solar modules with carbon-based electrodes are demonstrated, which are subjected to a "hotspot" test described in the IEC 61215:2016 international standard at an accredited module testing laboratory. Passing this accelerated test for the first time confirms the superior stability of perovskite PV devices with carbon-based electrodes and highlights their large industrialization potential.

14 SOLAR ENERGY↗

Data-driven cyber-attack detection for photovoltaic systems: A transfer learning approach

With increasing exposure to software-based sensing and control, power systems are facing higher risks of cyber/physical attacks. Here, to ensure system stability and minimize the potential economic losses, it is imperative to monitor the operating states and detect those attacks at the early stage. In this paper, a transfer learning method is proposed to detect cyber-attacks in photovoltaic (PV) systems with much less training data. First of all, two PV systems with a different number of PV inverters and power ratings are analyzed and their attack models are studied. Next, an attack detection Convolutional Neural Network (CNN) model was trained with rich amount of data from PV #1. Then, transfer learning was proposed to transfer the well-trained features from PV #1 to PV #2. Lastly, the attack detection model on PV #2 was trained based on the transferred CNN model. The experiment results show that the proposed transfer learning method achieves better accuracy and a faster convergence rate with a much less training dataset than conventional deep learning.

14 SOLAR ENERGY↗

Addressing Soiling: From Interface Chemistry to Practicality

Natural soiling has reduced the energy output of photovoltaic (PV) systems since the technology was first used. Projecting even a small average annual soiling loss translates to billions of dollars in annual lost revenue worldwide. Production losses due to soiling can be very high in some locations, substantially increasing the levelized cost of electricity (LCOE) due to lost power production, increased operating and maintenance costs, and/or increased finance cost due to the uncertainty. Furthermore, although soiling has been discussed in the literature for more than 70 years, solutions to many problems are still needed. The National Renewable Energy Laboratory (NREL) is working with the PV industry to develop the tools/knowledge so that the effects of soiling can be predicted for different environmental conditions and cost-effective mitigation can be implemented. For this project, NREL performed a number of research and development tasks/subtasks in the following general areas to 1) predict PV module soiling losses based on environmental factors at a PV installation and from its energy production data, 2) quantitatively measure the adhesion forces to understand the physics enabling soiling, and 3) develop related standards on PV module coatings and artificial soiling. At the inception of the project, the PV industry considered these efforts to be the most important and immediate soiling issues that we could address to have the highest impact on LCOE. These focused efforts have led to outstanding accomplishments that have been communicated and very well received by the community.

14 SOLAR ENERGY↗

Nighttime electric power generation at a density of 50 mW/m 2 via radiative cooling of a photovoltaic cell

A large fraction of the world's population lacks access to the electric grid. Standard photovoltaic (PV) cells can provide a renewable off-grid source of electricity but only produce power from daytime solar irradiance and do not produce power at night. While there have been several theoretical proposals and experimental demonstrations of energy harvesting from the radiative cooling of a PV cell at night, the achieved power density is very low. Here, we construct a device, which incorporates a thermoelectric generator that harvests electricity from the temperature difference between the PV cell and the ambient surrounding. We achieve 50 mW/m 2 nighttime power generation with a clear night sky, with an open-circuit voltage of 100 mV, which is orders of magnitude higher as compared with previous demonstrations. During the daytime, the thermoelectric generator also provides additional power on top of the electric power generated directly from the PV cells. Our system can be used as a continuous renewable power source for both day- and nighttime in off-grid locations.

14 SOLAR ENERGY↗