Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Kernelized Generalized Likelihood Ratio Test for Spectrum Sensing in Cognitive Radio

Spectrum sensing in next-generation wireless radio networks is considered a key technology to overcome the problem of spectrum scarcity. Unfortunately, many approaches to spectrum sensing do not work well in low signal-to-noise ratio (SNR) environments. This paper proposes and analyzes a new algorithm named kernelized generalized likelihood ratio test (KGLRT) for spectrum sensing in cognitive radio systems to overcome this problem. Effectively, KGLRT uses a nonlinear kernel to map input data onto a high-dimensional feature space; then, the widely accepted (linear) generalized likelihood ratio test is used for hypothesis testing. This new algorithm gives a gain of 4 dB in SNR over its linear counterpart. A theoretical analysis for this algorithm is given for the first time and is shown analogous to algorithms used in image signal processing. The detection metrics are found to be concentrated random variables; furthermore, the probability distributions of the detection metrics are proved to follow the F -distributions, which agree with the results obtained using the concentration inequality. The analytical thresholds are derived for target false-alarm probabilities. Here, the thresholds are independent of noise power; thus, the proposed algorithm can overcome noise uncertainty issues at very low SNR levels. Simulations validate the theoretical results.

47 OTHER INSTRUMENTATION↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

Land cover classification in multispectral imagery using clustering of sparse approximations over learned feature dictionaries

We present results from an ongoing effort to extend neuromimetic machine vision algorithms to multispectral data using adaptive signal processing combined with compressive sensing and machine learning techniques. Our goal is to develop a robust classification methodology that will allow for automated discretization of the landscape into distinct units based on attributes such as vegetation, surface hydrological properties, and topographic/geomorphic characteristics. We use a Hebbian learning rule to build spectral-textural dictionaries that are tailored for classification. We learn our dictionaries from millions of overlapping multispectral image patches and then use a pursuit search to generate classification features. Land cover labels are automatically generated using unsupervised clustering of sparse approximations (CoSA). We demonstrate our method on multispectral WorldView-2 data from a coastal plain ecosystem in Barrow, Alaska. We explore learning from both raw multispectral imagery and normalized band difference indices. We explore a quantitative metric to evaluate the spectral properties of the clusters in order to potentially aid in assigning land cover categories to the cluster labels. In this study, our results suggest CoSA is a promising approach to unsupervised land cover classification in high-resolution satellite imagery.

42 ENGINEERING↗

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

Current Trends in Gamma Radiation Detection for Radiological Emergency Response

Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of interdisciplinary research and development has taken place–techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation–the so-called second line of defense.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry

Purpose: An important property of a reusable dosimeter is its radiation hardness, that is, its ability to retain its dosimetric merits after irradiation. The radiation hardness of europium doped potassium chloride (KCl:Eu{sup 2+}), a storage phosphor material recently proposed for radiation therapy dosimetry, is examined in this study. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The pellets were exposed by a 6 MV photon beam or in a high dose rate {sup 137}Cs irradiator. Macroscopic properties, such as radiation sensitivity, dose response linearity, and signal stability, were studied with a laboratory photostimulated luminescence (PSL) readout system. Since phosphor performance is related to the state of the storage centers and the activator, Eu{sup 2+}, in the host lattice, spectroscopic and temporal measurements were carried out in order to explore radiation-induced changes at the microscopic level. Results: KCl:Eu{sup 2+} dosimeters retained approximately 90% of their initial signal strength after a 5000 Gy dose history. Dose response was initially supralinear over the dose range of 100-700 cGy but became linear after 60 Gy. Linearity did not change significantly in the 0-5000 Gy dose history spanned in this study. Annealing high dose history chips resulted in a return of supralinearity and a recovery of sensitivity. There were no significant changes in the PSL stimulation spectra, PSL emission spectra, photoluminescence spectra, or luminescence lifetime, indicating that the PSL signal process remains intact after irradiation but at a reduced efficiency due to reparable radiation-induced perturbations in the crystal lattice. Conclusions: Systematic studies of KCl:Eu{sup 2+} material are important for understanding how the material can be optimized for radiation therapy dosimetry purposes. The data presented here indicate that KCl:Eu{sup 2+} exhibits strong radiation hardness and lends support for further investigations of this novel material.

36 MATERIALS SCIENCE↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Structure of the immunoregulatory sialidase NEU1

Sialic acids linked to glycoproteins and glycolipids are important mediators of cell and protein recognition events. These sugar residues are removed by neuraminidases (sialidases). Neuraminidase-1 (sialidase-1 or NEU1) is a ubiquitously expressed mammalian sialidase located in lysosomes and on the cell membrane. Because of its modulation of multiple signaling processes, it is a potential therapeutic target for cancers and immune disorders. Genetic defects in NEU1 or in its protective protein cathepsin A (PPCA, CTSA) cause the lysosomal storage diseases sialidosis and galactosialidosis. To further our understanding of this enzyme’s function at the molecular level, we determined the three-dimensional structure of murine NEU1. The enzyme oligomerizes through two self-association interfaces and displays a wide substrate-binding cavity. A catalytic loop adopts an inactive conformation. We propose a mechanism of activation involving a conformational change in this loop upon binding to its protective protein. These findings may facilitate the development of selective inhibitor and agonist therapies.

59 BASIC BIOLOGICAL SCIENCES↗

Terahertz stimulated parametric downconversion of a magnon mode in an antiferromagnet

Parametric amplification, where one signal is enhanced by the action of another, offers both practical utility for boosting weak signals and fundamental insights into the nonlinear coupling between degrees of freedom. In condensed matter systems, interactions between collective modes offer avenues for nonlinear coherent manipulation of coupled excitations and quantum phases. Antiferromagnets, with inherently coupled magnon modes, provide a promising platform for nonlinear control of spin waves and magnetization. However, nonlinear magnon-magnon interactions have been only partially elaborated, leaving key gaps in the prospects for potential ultrahigh-bandwidth magnonic signal processing. Here, we excite two distinct coherent magnon modes in an antiferromagnet and find that the magnon mode with a lower frequency undergoes amplification when the higher-frequency mode is driven. We unveil the nonlinear excitation pathways of this stimulated parametric downconversion process by using polarization-selective two-dimensional terahertz spectroscopy. Our work provides fundamental insights into nonlinear magnonics in antiferromagnets, laying the groundwork for forthcoming spintronic and magnonic devices.

Science & Technology - Other Topics↗

Investigation of the maximum accessible kinetic energy of fragments in the neutron-induced fission of {sup 238}U nuclei

The masses, total kinetic energies (TKE), and emission angles of fragments originating from the fission of {sup 238}U nuclei that was induced by 5- and 6.5-MeV neutrons were measured by using digital methods for processing signals. A detailed analysis of the shape of digital signals made it possible to reduce substantially the contribution of fragments whose TKE values were distorted because of a superimposition of signals from recoil protons and from alpha particles produced in the spontaneous decay of uranium. The total statistics exceeded two million events for either neutron energy, and this permitted performing a detailed analysis of fission-fragment yields in the region of the highest attainable TKE values. An analysis of fragment yields made it possible to draw specific conclusions on the structure of the potential surface of fissile nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient Parallel Sparse Symmetric Tucker Decomposition for High-Order Tensors

Tensor based methods are receiving renewed attention in recent years due to their prevalence in diverse real-world applications. There is considerable literature on tensor representations and algorithms for tensor decompositions, both for dense and sparse tensors. Many applications in hypergraph analytics, machine learning, psychometry, and signal processing result in tensors that are both sparse and symmetric, making it an important class for further study. Similar to the critical Tensor Times Matrix chain operation (TTMc) in general sparse tensors, the Sparse Symmetric Tensor Times Same Matrix chain (S3TTMc) operation is compute and memory intensive due to high tensor order and the associated factorial explosion in the number of non-zeros. In this work, we present a novel compressed storage format CSS for sparse symmetric tensors, along with an efficient parallel algorithm for the S3TTMc operation. We theoretically establish that S3TTMc on CSS achieves a better memory versus run-time trade-off compared to state-of-the-art implementations. We demonstrate experimental findings that confirm these results and achieve up to 2.9× speedup on synthetic and real datasets.

Shivakumar, Shruti↗

Efficient Projection onto the $\ell_{\infty,1}$ Mixed-Norm Ball Using a Newton Root Search Method

Mixed norms that promote structured sparsity have numerous applications in signal processing and machine learning problems. Here, we present a new algorithm, based on a Newton root search technique, for computing the projection onto the $\ell_{\infty,1}$ ball, which has found application in cognitive neuroscience and classification tasks. Numerical simulations show that our proposed method is between 8 and 10 times faster on average, and up to 20 times faster for very sparse solutions, than the previous state of the art. Lastly, tests on real functional magnetic resonance image data show that, for some data distributions, our algorithm can obtain speed improvements by a factor of between 10 and 100, depending on the implementation.

97 MATHEMATICS AND COMPUTING↗

Computationally Efficient Decompositions of Oblique Projection Matrices

Oblique projection matrices arise in problems in weighted least squares, signal processing, and optimization. While these matrices can be potentially very large, their low-rank structure can be exploited for efficient computation. Here, we propose fast and scalable algorithms for computing their eigendecomposition and singular value decomposition (SVD). Numerical experiments that compare our proposed approaches to existing methods, including randomized SVD, are presented. In addition, we test their accuracy on linear systems from equality constrained optimization problems.

97 MATHEMATICS AND COMPUTING↗

Managing the Performance/Error Tradeoff of Floating-point Intensive Applications

Modern embedded systems are becoming more reliant on real-valued arithmetic as they employ mathematically complex vision algorithms and sensor signal processing. Double-precision floating point is the most commonly used precision in computer vision algorithm implementations. A single-precision floating point can provide a performance boost due to less memory transfers, less cache occupancy, and relatively faster mathematical operations on some architectures. However, adopting it can result in loss of accuracy. Identifying which parts of the program can run in single-precision floating point with low impact on error is a manual and tedious process. In this paper, we propose an automatic approach to identify parts of the program that have a low impact on error using shadow-value analysis. Our approach provides the user with a performance/error tradeoff, using which the user can decide how much accuracy can be sacrificed in return for performance improvement. We illustrate the impact of the approach using a well known implementation of Apriltag detection used in robotics vision. In conclusion, we demonstrate that an average 1.3x speedup can be achieved with no impact on tag detection, and a 1.7x speedup with only 4% false negatives.

97 MATHEMATICS AND COMPUTING↗

A Sparse Tensor Benchmark Suite for CPUs and GPUs

Tensor computations present significant performance chal- lenges that impact a wide spectrum of applications ranging from machine learning, healthcare analytics, social network analysis, data mining to quantum chemistry and signal processing. Efforts to improve the perfor- mance of tensor computations include exploring data layout, execution scheduling, and parallelism in common tensor kernels. This work presents a benchmark suite for arbitrary-order sparse tensor kernels using state- of-the-art tensor formats: coordinate (COO) and hierarchical coordinate (HiCOO) on CPUs and GPUs. It presents a set of reference tensor kernel implementations that are compatible with real-world tensors and power law tensors extended from synthetic graph generation techniques. We also propose Roofline performance models for these kernels to provide insights of computer platforms from sparse tensor view. This benchmark suite along with the synthetic tensor generator is publicly available.

Li, Jiajia↗