Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Screening design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Co-optimization of fuel properties, combustion system geometry, and injection strategy for conventional diesel fuel

Here, studies have shown that fuel properties can impact an engine’s operation in several ways, including ignition delay, sooting tendency, mixture formation, and combustion temperature. In mixing-controlled compression ignition (MCCI) engines, the fuel system design and piston bowl geometry significantly affect combustion performance and emissions. Based on current information, it is difficult to draw conclusions about fuel property effects and sensitivities. The central fuel hypothesis approach used in the US Department of Energy Co-Optima program has worked well for spark ignition fuels: identifying critical fuel property ranges is sufficient to screen fuel blends that are expected to maximize efficiency and reduce pollutant emissions. However, for MCCI-relevant fuels, the information gained from past studies is not sufficient to build such a merit function or to allow for performing a similar screening of fuel blends. It is hypothesized that a co-optimization of a fuel’s physical and chemical properties, combustion system geometry, and injection strategy could leverage synergies between the effects of the fuel properties and geometries, resulting in improved performance over state-of-the-art. A machine learning–assisted unconstrained global optimization algorithm was used to explore a design space comprising 23 independent variables. The results show that physical property effects were minimal even for large variations in fuel properties, and the only interaction effect that was observed was the effect of varied fuel density parameters on fuel/air mixture formation. Nevertheless, these interactions were not sufficient in magnitude to significantly affect optimization results. Therefore, analysis of the results suggests that fuel physical properties cannot be leveraged in a co-optimization context to increase engine efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

Health Management Clinic Report FY18

The Health Management Clinic (HMC) is a worksite specialty clinic designed to provide an exceptional level of health care for Sandia employees with diabetes, cholesterol and blood pressure disorders, and for those employees that need help with smoking cessation, depression, anxiety, sleep disorders, or weight management. With a unified commitment to the best care practices available, the HMC is Sandia’s interface to workplace healthcare and health plan services. The HMC provides Sandia employees access to onsite screenings, health care exams, preventative health education, disease management education, care management, periodic laboratory testing, immunizations, podiatry services, and behavioral, fitness, and nutrition counseling/education. Our multidisciplinary team of health professionals consists of physicians, nurses, medical assistants, certified diabetes educators, dietitians, health educators, and exercise specialists. Services offered by the Health Management clinic have been designed to reduce further complications from disease states and promote healthy behavior changes for Sandia employees.

60 APPLIED LIFE SCIENCES↗

Vacuum system of the compact Energy Recovery Linac

The compact Energy Recovery Linac (cERL), a test accelerator to establish important technologies demanded for future ERL-based light sources, was constructed in late 2013 at KEK. The accelerator was successfully commissioned in early 2014, and demonstrated beam circulation with energy recovery. In the cERL vacuum system, low-impedance vacuum components are required to circulate high-intensity, low-emittance and short-bunch electron beams. We therefore developed ultra-high-vacuum (UHV)-compatible flanges that can connect beam tubes seamlessly, and employed retractable beam monitors, namely, a movable Faraday cup and screen monitors. In most parts of the accelerator, pressures below 1×10{sup −7} Pa are required to mitigate beam-gas interactions. Particularly, near the photocathode electron gun and the superconducting (SC) cavities, pressures below 1×10{sup −8} Pa are required. The beam tubes in the sections adjoining the SC cavities were coated with non-evaporable getter (NEG) materials, to reduce gas condensation on the cryo-surfaces. During the accelerator commissioning, stray magnetic fields from the permanent magnets of some cold cathode gauges (CCGs) were identified as a source of the disturbance to the beam orbit. Magnetic shielding was specially designed as a remedy for this issue.

43 PARTICLE ACCELERATORS↗

Toward Guided Mutagenesis: Gaussian Process Regression Predicts MHC Class II Antigen Mutant Binding

Antigen-specific immunotherapies (ASI) require successful loading and presentation of antigen peptides into the major histocompatibility complex (MHC) binding cleft. One route of ASI design is to mutate native antigens for either stronger or weaker binding interaction to MHC. Exploring all possible mutations is costly both experimentally and computationally. To reduce experimental and computational expense, here we investigate the minimal amount of prior data required to accurately predict the relative binding affinity of point mutations for peptide-MHC class II (pMHCII) binding. Using data from different residue subsets, we interpolate pMHCII mutant binding affinities by Gaussian process (GP) regression of residue volume and hydrophobicity. We apply GP regression to an experimental data set from the Immune Epitope Database, and theoretical data sets from NetMHCIIpan and Free Energy Perturbation calculations. We find that GP regression can predict binding affinities of nine neutral residues from a six-residue subset with an average R 2 coefficient of determination value of 0.62 ± 0.04 (±95% CI), average error of 0.09 ± 0.01 kcal/mol (±95% CI), and with an receiver operating characteristic (ROC) AUC value of 0.92 for binary classification of enhanced or diminished binding affinity. Similarly, metrics increase to an R2 value of 0.69 ± 0.04, average error of 0.07 ± 0.01 kcal/mol, and an ROC AUC value of 0.94 for predicting seven neutral residues from an eight-residue subset. Our work finds that prediction is most accurate for neutral residues at anchor residue sites without register shift. This work holds relevance to predicting pMHCII binding and accelerating ASI design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PDFDataExtractor: A Tool for Reading Scientific Text and Interpreting Metadata from the Typeset Literature in the Portable Document Format

The layout of portable document format (PDF) files is constant to any screen, and the metadata therein are latent, compared to mark-up languages such as HTML and XML. No semantic tags are usually provided, and a PDF file is not designed to be edited or its data interpreted by software. However, data held in PDF files need to be extracted in order to comply with opensource data requirements that are now government-regulated. In the chemical domain, related chemical and property data also need to be found, and their correlations need to be exploited to enable data science in areas such as data-driven materials discovery. Such relationships may be realized using text-mining software such as the “chemistry-aware” natural-language-processing tool, ChemDataExtractor; however, this tool has limited data-extraction capabilities from PDF files. This study presents the PDFDataExtractor tool, which can act as a plug-in to ChemDataExtractor. It outperforms other PDF-extraction tools for the chemical literature by coupling its functionalities to the chemical-named entityrecognition capabilities of ChemDataExtractor. The intrinsic PDF-reading abilities of ChemDataExtractor are much improved. The system features a template-based architecture. This enables semantic information to be extracted from the PDF files of scientific articles in order to reconstruct the logical structure of articles. While other existing PDF-extracting tools focus on quantity mining, this template-based system is more focused on quality mining on different layouts. PDFDataExtractor outputs information in JSON and plain text, including the metadata of a PDF file, such as paper title, authors, affiliation, email, abstract, keywords, journal, year, document object identifier (DOI), reference, and issue number. With a self-created evaluation article set, PDFDataExtractor achieved promising precision for all key assessed metadata areas of the document text.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovery of Macrocyclic Inhibitors of Apurinic/Apyrimidinic Endonuclease 1

Apurinic/apyrimidinic endonuclease 1 (APE1) is an essential base excision repair enzyme that is upregulated in a number of cancers, contributes to resistance of tumors treated with DNA-alkylating or -oxidizing agents, and has recently been identified as an important therapeutic target. Here in this work, we identified hot spots for binding of small organic molecules experimentally in high resolution crystal structures of APE1 and computationally through the use of FTMAP analysis (http://ftmap.bu.edu/). Guided by these hot spots, a library of drug-like macrocycles was docked and then screened for inhibition of APE1 endonuclease activity. In an iterative process, hot-spot-guided docking, characterization of inhibition of APE1 endonuclease, and cytotoxicity of cancer cells were used to design next generation macrocycles. To assess target selectivity in cells, selected macrocycles were analyzed for modulation of DNA damage. Taken together, our studies suggest that macrocycles represent a promising class of compounds for inhibition of APE1 in cancer cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coaxial probe for nuclear magnetic resonance diffusion and relaxation correlation experiments

A coaxial nuclear magnetic resonance (NMR) probe is built to measure diffusion and relaxation properties of liquid samples. In particular, we demonstrate the acquisition of two-dimensional (2D) distribution functions (T{sub 1}-T{sub 2} and diffusion–T{sub 2}), essential for fluids characterization. The compact design holds promise for miniaturization, thus enabling the measurement of molecular diffusion that is inaccessible to conventional micro-NMR setups. Potential applications range from crude oil characterization to biomolecular screening and detections.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Throughput Discovery of Robust Metal-Organic Frameworks for CO 2 Capture (Final Report)

The goal of the project is to develop and utilize high-throughput instrumentation for the discovery of robust, cost-effective metal-organic frameworks for the efficient capture of CO 2 from power plant flue gas. To this end, we have used highly-parallel and automated synthesize methods to accelerate the discovery of new MOF structures and their optimized synthesis and activation routes. To be able to rapidly screen these new materials for their potential CO 2 capture performance, we have developed high-throughput structural characterization instruments and gas adsorption instruments. To guide the materials choice and design, we have also developed computational tools to analyze the life cycle and sorbent performance of existing and hypothetical materials.

36 MATERIALS SCIENCE↗

Performance and Efficiency of Biomass Densification Equipment (CRADA Final Report)

In 2008, a CRADA between the INL and Vermeer was signed and work began between the two parties to look at improvements in grinding processes for agricultural crop residues. Preprocessing is a critical operation in the biomass feedstock assembly system of a lignocellulosic biorefinery. Preprocessing is typically accomplished using industrial grinders to grind, chop, or otherwise size-reduce biomass materials into a suitable feedstock for conversion to biofuels and bioproducts. Various components of commercial preprocessing equipment capable of handling large-format material (such as large square bales) can be modified or altered to change the overall productivity and efficiency of the process. Many factors affect machine capacity and efficiency and the physical characteristics of preprocessed biomass. Ultimately, grinder capacity and efficiency can be enhanced by selecting hammer and screen configurations that optimize grinder performance-based mass flow and energy consumption. Variations in grinder capacity and efficiency were evaluated by altering the type, number, and orientation of the hammer; the screen type and size; and the rotational drum speed of the grinder. Fuel use and grinder capacity were compared with each modification made to the grinder system and the original design of the horizontal grinder test platform. Modifications evaluated in this study resulted in a significant increase in grinder capacity and efficiency.

09 BIOMASS FUELS↗

Deep Recurrent Neural Networks for seizure detection and early seizure detection systems

Epilepsy is common neurological diseases, affecting about 0.6-0.8 % of world population. Epileptic patients suffer from chronic unprovoked seizures, which can result in broad spectrum of debilitating medical and social consequences. Since seizures, in general, occur infrequently and are unpredictable, automated seizure detection systems are recommended to screen for seizures during long-term electroencephalogram (EEG) recordings. In addition, systems for early seizure detection can lead to the development of new types of intervention systems that are designed to control or shorten the duration of seizure events. In this article, we investigate the utility of recurrent neural networks (RNNs) in designing seizure detection and early seizure detection systems. We propose a deep learning framework via the use of Gated Recurrent Unit (GRU) RNNs for seizure detection. We use publicly available data in order to evaluate our method and demonstrate very promising evaluation results with overall accuracy close to 100 %. We also systematically investigate the application of our method for early seizure warning systems. Our method can detect about 98% of seizure events within the first 5 seconds of the overall epileptic seizure duration.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-band reflector antenna with double-ring element frequency selective subreflector

Frequency selective subreflectors (FSS) are often employed in the reflector antenna system of a communication satellite or a deep space exploration vehicle for multi-frequency operations. In the past, FSS's have been designed for diplexing two frequency bands. For example, the Voyager FSS was designed to diplex S and X bands and the TDRSS FSS was designed to diplex S and Ku bands. Recently, NASA's CASSINI project requires an FSS to multiplex four frequency (S/X/Ku/Ka) bands. Theoretical analysis and experimental verifications are presented for a multi-band flat pannel FSS with double-ring elements. Both the exact formulation and the thin-ring approximation are described for analyzing and designing this multi-ring patch element FSS. It is found that the thin-ring approximation fails to predict the electrically wide ring element FSS's performance. A single screen double-ring element FSS is demonstrated for the tri-band system that reflects the X-band signal while transmitting through the S- and Ku-band signals. In addition, a double screen FSS with non-similar double-ring elements is presented for the Cassini's four-band system which reflects the X- and Ka-band signals while passing the S- and Ku-band signals. To accurately predict the FSS effects on a dual reflector antenna's radiation pattern, the FSS subreflector's transmitted/reflected field variation as functions of the polarization and incident angles with respect to the local coordinates was taken into account. An FSS transmission/reflection coefficient table is computed for TE and TM polarizations at various incident angles based on the planar FSS model. Next, the hybrid Geometric Optics (GO) and Physical Optics (PO) technique is implemented with linearly interpolating the FSS table to efficiently determine the FSS effects in a dual reflector antenna.

Wu, Te-Kao↗

Investigation of Moving Belt Radiator Technology Issues

The development of an advanced spacecraft radiator technology is reported. The moving belt radiator is a thermal radiator concept with the promise of lower specific mass (per kW rejected) than that afforded by existing technologies. The results of a parametric study to estimate radiator mass for future space power systems is presented. It is shown that this technology can be scaled up to 200 MW for higher rejection temperatures. Several aspects of the design concept are discussed, including the dynamics of a large rotating belt in microgravity. The results of a computer code developed to model the belt dynamics are presented. A series of one-g experiments to investigate the dynamics of small belts is described. A comprehensive test program to investigate belt dynamics in microgravity aboard the NASA KC-135 aircraft is discussed. It was found that the desired circular shape can readily be achieved in microgravity. It is also shown that a rotating belt is stable when subjected to simulated attitude control maneuvers. Heat exchanger design is also investigated. Several sealing concepts were examined experimentally, and are discussed. Overall heat transfer coefficients to the rotating belt are presented. Material properties for various belt materials, including screen meshes, are also presented. The results presented in this report indicate that the moving belt radiator concept is technically feasible.

Teagan, W. Peter↗

Toward Synthesis, Analysis, and Certification of Security Protocols

Implemented security protocols are basically pieces of software which are used to (a) authenticate the other communication partners, (b) establish a secure communication channel between them (using insecure communication media), and (c) transfer data between the communication partners in such a way that these data only available to the desired receiver, but not to anyone else. Such an implementation usually consists of the following components: the protocol-engine, which controls in which sequence the messages of the protocol are sent over the network, and which controls the assembly/disassembly and processing (e.g., decryption) of the data. the cryptographic routines to actually encrypt or decrypt the data (using given keys), and t,he interface to the operating system and to the application. For a correct working of such a security protocol, all of these components must work flawlessly. Many formal-methods based techniques for the analysis of a security protocols have been developed. They range from using specific logics (e.g.: BAN-logic [4], or higher order logics [12] to model checking [2] approaches. In each approach, the analysis tries to prove that no (or at least not a modeled intruder) can get access to secret data. Otherwise, a scenario illustrating the &tack may be produced. Despite the seeming simplicity of security protocols ("only" a few messages are sent between the protocol partners in order to ensure a secure communication), many flaws have been detected. Unfortunately, even a perfect protocol engine does not guarantee flawless working of a security protocol, as incidents show. Many break-ins and security vulnerabilities are caused by exploiting errors in the implementation of the protocol engine or the underlying operating system. Attacks using buffer-overflows are a very common class of such attacks. Errors in the implementation of exception or error handling can open up additional vulnerabilities. For example, on a website with a log-in screen: multiple tries with invalid passwords caused the expected error message (too many retries). but let the user nevertheless pass. Finally, security can be compromised by silly implementation bugs or design decisions. In a commercial VPN software, all calls to the encryption routines were incidentally replaced by stubs, probably during factory testing. The product worked nicely. and the error (an open VPN) would have gone undetected, if a team member had not inspected the low-level traffic out of curiosity. Also, the use secret proprietary encryption routines can backfire, because such algorithms often exhibit weaknesses which can be exploited easily (see e.g., DVD encoding). Summarizing, there is large number of possibilities to make errors which can compromise the security of a protocol. In today s world with short time-to-market and the use of security protocols in open and hostile networks for safety-critical applications (e.g., power or air-traffic control), such slips could lead to catastrophic situations. Thus, formal methods and automatic reasoning techniques should not be used just for the formal proof of absence of an attack, but they ought to be used to provide an end-to-end tool-supported framework for security software. With such an approach all required artifacts (code, documentation, test cases) , formal analyses, and reliable certification will be generated automatically, given a single, high level specification. By a combination of program synthesis, formal protocol analysis, certification; and proof-carrying code, this goal is within practical reach, since all the important technologies for such an approach actually exist and only need to be assembled in the right way.

Schumann, Johann↗

Identification of a mouse B-type cyclin which exhibits developmentally regulated expression in the germ line

To begin to examine the function of cyclins in mammalian germ cells, we have screened an adult mouse testis cDNA library for the presence of B-type cyclins. We have isolated cDNAs that encode a murine B-type cyclin, which has been designated cycB1. cycB1 was shown to be expressed in several adult tissues and in the midgestation mouse embryo. In the adult tissues, the highest levels of cycB1 transcripts were seen in the testis and ovary, which contain germ cells at various stages of differentiation. The major transcripts corresponding to cycB1 are 1.7 and 2.5 kb, with the 1.7 kb species being the predominant testicular transcript and the 2.5 kb species more abundant in the ovary. Examination of cDNAs corresponding to the 2.5 kb and 1.7 kb mRNAs revealed that these transcripts encode identical proteins, differing only in the polyadenylation signal used and therefore in the length of their 3' untranslated regions. Northern blot and in situ hybridization analyses revealed that the predominant sites of cycB1 expression in the testis and ovary were in the germinal compartment, particularly in early round spermatids in the testis and growing oocytes in the ovary. Thus cycB1 is expressed in both meiotic and postmeiotic cells. This pattern of cycB1 expression further suggests that cycB1 may have different functions in the two cell types, only one of which correlates with progression of the cell cycle.

NASA Discipline Developmental Biology↗

Liquid Acquisition Strategies for Exploration Missions: Current Status 2010

NASA is currently developing the propulsion system concepts for human exploration missions to the lunar surface. The propulsion concepts being investigated are considering the use of cryogenic propellants for the low gravity portion of the mission, that is, the lunar transit, lunar orbit insertion, lunar descent and the rendezvous in lunar orbit with a service module after ascent from the lunar surface. These propulsion concepts will require the vapor free delivery of the cryogenic propellants stored in the propulsion tanks to the exploration vehicles main propulsion system (MPS) engines and reaction control system (RCS) engines. Propellant management devices (PMD s) such as screen channel capillary liquid acquisition devices (LAD s), vanes and sponges currently are used for earth storable propellants in the Space Shuttle Orbiter OMS and RCS applications and spacecraft propulsion applications but only very limited propellant management capability exists for cryogenic propellants. NASA has begun a technology program to develop LAD cryogenic fluid management (CFM) technology through a government in-house ground test program of accurately measuring the bubble point delta-pressure for typical screen samples using LO2, LN2, LH2 and LCH4 as test fluids at various fluid temperatures and pressures. This presentation will document the CFM project s progress to date in concept designs, as well ground testing results.

Chato, David J.↗

Virtual Ultrasound Guidance for Inexperienced Operators

Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with advice on technique. The program also instructs the operator regarding the types of images to store and how to overcome pitfalls in scanning. Images can be forwarded to the ground or other site when convenient. Following study completion, the video glasses, video source, and ultrasound system are powered down and stored. Virtually any equipment that can play back video can be used to play back the program. This includes a DVD player, personal computer, and some MP3 players.

Caine, Timothy↗

Using solar eclipse events to validate VIIRS reflective solar band calibration at multiple radiance levels

The VIIRS instruments aboard the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands (RSB) covering a spectral range from 412 nm to 2250 nm. The radiance of each VIIRS RSB is calculated from a quadratic function of the background-subtracted digital count, 𝑑𝑛, with the quadratic coefficients determined during pre-launch testing. On orbit, calibration is maintained using observations of a sunlit solar diffuser (SD), which views the Sun every orbit through a fixed attenuation screen. The SD observations, which are at nearly the same radiance level every orbit, provide a time varying overall calibration adjustment factor, the F-factor. But there is no designed on-orbit mechanism for calibration at multiple radiance levels, so the relative strengths of the quadratic coefficients continue to be fixed at the pre-launch values. On a few rare occasions, the VIIRS instruments have passed through a partial solar eclipse during the part of the satellite orbit when the SD is illuminated by the Sun (near the South Pole). As of August 2019, the SNPP and N20 VIIRS SDs have observed five and three partial solar eclipses, respectively. While these events are rare, they offer a unique opportunity to test the RSB calibration using the SD at different radiance levels. In this paper, we compare the reduction in the measured SD signals during an eclipse to the predicted radiance reduction based on the Sun-Moon geometry and a solar radiance model. We find good agreement between the data and model for all events, indicating that the VIIRS RSB gain linearity has remained fairly stable on-orbit. The most significant deviation is for the N20 short-wave infrared bands, which had non-linearity concerns during pre-launch testing. We also investigate the SNPP results using different versions of the prelaunch quadratic gain coefficients.

solar eclipse↗

Eye Glance Behaviors of Ground Control Station Operators in a Simulated Urban Air Mobility Environment

Research into concepts such as advanced air mobility (AAM) and urban air mobility (UAM) offers an opportunity for successfully and safely adding new classes of vehicles into the National Airspace System. However, a need exists for research into the human factors associated with these concepts. In this paper, we evaluate the gaze behaviors of three remote ground control station operators (GCSOs) conducting simulated UAM operations. The participants monitored and controlled an unmanned aircraft system (UAS) from pre-flight to landing using ground control station (GCS) software across nine scenarios within a remote UAS operations center at NASA Langley Research Center (LaRC). As this work was exploratory, descriptive statistics were calculated to provide some initial insight into GCSO gaze patterns associated with the GCS display. Scenarios that required the operator to directly interact with an airspace scheduling system off-screen resulted in fewer on-screen glances than scenarios that did not include direct interactions with the off-screen system. After investigating several areas of interest (AOIs) within the GCS display, participants primarily viewed three AOIs: the map, vehicle status, and operations checklist. The results yielded several GCS design and operational improvement recommendations to include: (a) adding altitude information to the vehicle icon, (b) adding additional traffic information, and (c) including additional GCS training, to reduce the need to scan an operations checklist, which would allow allocation of visual attention towards other AOIs.

Urban Air Mobility↗