Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Space Weathering in the Inner Solar System

"Space weathering" is the term given to the cumulative effects incurred by surfaces which are exposed to the harsh environment of space. Lunar sample studies over the last decade or so have produced a clear picture of space weathering processes in the lunar environment. By combining laboratory and remote spectra with microanalytical methods (scanning and transmission electron microscopy), we have begun to unravel the various processes (irradiation, micrometeorite bombardment, etc) that contribute to space weathering and the physical and optical consequences of those processes on the Moon. Using the understanding gleaned from lunar samples, it is possible to extrapolate weathering processes to other airless bodies from which we have not yet returned samples (i.e. Mercury, asteroids). Through experiments which simulate various components of weathering, the expected differences in environment (impact rate, distance from Sun, presence of a magnetic field, reduced or enhanced gravity, etc) and composition (particularly iron content) can be explored to understand how space weathering will manifest on a given body.

Noble, Sarah K.↗

Mars-GRAM Support for the Mars Ascent Vehicle

Mars sample return is a bold concept, which entails gathering a varied, scientifically-relevant collection of Martian rock core samples and bringing them to Earth for analysis. To support this endeavor, the Marshall Space Flight Center (MSFC) is developing the Mars Ascent Vehicle (MAV), which is responsible for getting the collected samples off the planet. The MAV Preliminary Architecture Assessment (PAA) study is designing two vehicle architectures based on different propulsion configurations: a two-stage solid-solid concept, and a hybrid concept. Given different thrust profiles for the two configurations, each concept uses a unique trajectory to reach the same orbit. In support of the PAA, The MSFC Natural Environments Branch (EV44) was asked to produce tables of atmospheric parameters along each of the two trajectories. The Mars Global Reference Atmospheric Model (Mars-GRAM) is an EV44 tool that is ideally suited for this analysis. Mars-GRAM will continue supporting MAV development in future design cycles.

Burns, K. L.↗

Evidence for a CERES-Sized, Water-Rich, Carbonaceous Chondrite Parent Asteroid: A Missing Link Found in the Almahata Sitta Meteorite

We have discovered abundant (~10 vol.%) tremolite amphibole in a carbonaceous chondrite (CC) fragment (202, C-ung) from the Almahata Sitta (AhS, Ur-anom) meteorite. Terrestrially, tremolite is a fairly common hydrous mineral that forms under greenschist facies conditions (300-500° C and ~2-8 kbar). Amphibole has been identified in two R chondrites at similar abundances, but it is virtually unknown in CC, having been identified only in Allende (CV3oxA) at trace to minor (likely <<1 vol.%) abundances. Thus, AhS 202 provides evidence of a previously unrecognized CC parent body that must have been of sufficient size (~500-1400 km diameter) to support prolonged, fluid-assisted metamorphism at intermediate pressures and temperatures. The previous detection of amphibole in a CC, even at very low abundances, is noteworthy as it indicates that conditions for that mineral’s formation existed in the early solar system, no matter how briefly or how localized. However, our detection of abundant amphibole in a second CC that implicates a second, large parent body suggests that moderately elevated, hydrous P/T conditions may have been more widespread than previously thought based on meteorites. The apparent absence of amphibole in most carbonaceous chondrites may reflect bias in our meteorite collections and/or failure to identify it in other samples. Finally, samples like AhS 202 provide important missing links if spaceflight missions such as Hayabusa2 and OSIRIS-REx return samples that differ from what exists in meteorite collections.

Victoria E Hamilton↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Characteristics of metal particles in Apollo 16 rocks

It is pointed out that FeNi metal particles, composed predominantly of kamacite and ranging in size from less than 1 micron to more than 2 mm across, are ubiquitous in the lunar samples returned by the Apollo and Luna missions. The metal particles seldom exceed 1% of the volume of a lunar sample. However, their study has proven to be of considerable potential value in a number of aspects of lunar petrogenesis related to thermal history, equilibration temperatures, reduction processes and oxygen fugacities during magmatic crystallization and subsolidus reduction and oxidation, and the meteoritic component of lunar rocks based on Ni-Co contents of individual metal particles. Detailed studies have been conducted of the textures and compositions of the metal particles in 19 Apollo 16 rock samples representing material from the North Ray and the South Ray ejecta and/or fall-back blankets. It was found that the textures and compositions of the metal particles in the Apollo 16 rocks can be correlated with their host petrology.

Misra, K. C.↗

Ka-band (32 GHz) benefits to planned missions

The benefits of using 32 GHz downlinks for a set of deep space missions, as well as the implications to radio science and the Deep Space Network (DSN) are documented. The basic comparison is between the use of the current X-band (8.4 GHz) and a 32 GHZ (Ka-band) downlink. There was shown to be approximately an 8 dB (about 600%) link advantage for 32 GHz. This 8 dB advantage would be able to either reduce mission cost or improve mission science return. Included here are studies on how the 8 dB advantage would be used for the Cassini and Mars Sample Return missions. While the work is preliminary, it shows that the 8 dB advantage can be exploited to provide large benefits to future deep space missions. There can be significant mass and/or power savings to the spacecraft, which can translate into cost savings. Alternatively, the increased downlink telecommunications performance can provide a greater science return.

Hansen, D. M.↗

Checking Contamination during Storage of Carbonaceous Chondrites for Micro FTIR Measurements

We examined organic contamination by Fourier transform infrared micro spectroscopic (micro FTIR) measurements of carbonaceous chondrite samples. Carbonaceous chondrites, Tagish Lake (C2), Murchison (CM2) and Moss (CO3), and some mineral powder samples pressed on aluminum plates were measured by micro FTIR before and after storage in several containers with silicone rubber mat. During storage, samples did not touch directly anything except the holding aluminum plates. The carbonaceous chondrites containing hydrous minerals (Tagish Lake and Murchison) pressed on aluminum plates and measured by transmission-reflection micro FTIR measurements were found to be contaminated during storage after only one day, as revealed by an increase of approximately 2965 /cm and approximately 1260 /cm peaks. The Moss meteorite which contains no hydrous minerals, did not show an increase of these peaks, indicating no organic contamination. This difference is probably related to the differing mineralogy and physical properties (including porosity and permeability) of these chondrites. Hydrous minerals such as antigorite, muscovite, montmorillonite and silica gel showed organic contamination by the same infrared measurements, while anhydrous materials such as SiO2 and KBr showed no contamination. These results indicate importance of surface OH groups for the organic contamination. Organic contamination was found on silica gel samples pressed on aluminum plates when they were stored within containers including silicone rubber, silicone grease or adhesive tape. Long path gas cell FTIR measurements for silicone rubber indicated methylsiloxane oligomers were released from the silicone rubber. In-situ heating infrared measurements on the contaminated antigorite and Tagish Lake showed decrease of the 1262 /cm (Si-CH3) and 2963 /cm (CH3) peaks from room temperature to 200-300 C indicating desorption of volatile contaminants. These results indicate that careful preparation and storage are essential for FTIR measurements on precious astromaterial samples such as meteorites, IDPs and samples returned from comets, asteroids and Mars. Every possible contamination source should be evaluated before anything is done to these samples.

Zolensky, Michael E.↗

Mars Ascent Vehicle (MAV) Concept - Launch System Development

A Mars Ascent Vehicle (MAV) would be one component of potential Mars Sample Return (MSR) and would have to launch from the surface of Mars into orbit about Mars with a soil sample. A MAV is a small lightweight rocket that must survive various environmental conditions, including powered ascent through the Martian atmosphere. A concept for the MAV system design includes a launch tube mounted on top of a mobile rover or a stationary lander. The launch tube must thermally insulate the MAV on the surface of Mars, and then guide the MAV during the initial portion of the launch. A mechanical erector system is also necessary for moving the MAV and launch tube from a stowed configuration to a launch configuration. The launch system would have to perform these tasks while also meeting many design constraints. This paper is a systems engineering perspective that will examine the current development of the launch system including design concepts, design trades, driving issues, and analyses performed. Design trades include different launch configurations that would prevent rover or lander tip-over, as well as re-contact between the MAV and the launch tube. Additional trades include options for guiding the MAV out of the launch tube, whether using launch rails or sabots, and finding a reliable but simple mechanical erector system. Analyses include investigating the impact of ignition overpressure based on launch configuration, launch loads and sensitivities to the launch system design, and Entry, Descent and Landing loads. The key considerations for these design trades are overall system mass, size, and reliability.

Sonneveldt, Bryan↗

Outer Solar System Carbon in the Laboratory

Samples of outer solar system carbon in various forms are available for analysis in the laboratory. The Stardust Mission returned organics and a few carbonate grains from Jupiter Class comet Wild-2 [1]. These complement similar phases available in chondritic interplanetary dust particles, some of which derive from comets, although it is not definitively known which have that origin. Carbonaceous chondrites probably derive from C-complex asteroids which may have outer solar system origins, though this origin is model dependent. There are rare carbonaceous xenoliths in, principally, ordinary chondrites and ureilites whose bulk isotopic and bulk chemical compositions suggest an origin farther from the Sun that the remainder of carbonaceous chondrites [2,3]. These contain abundant carbonaceous materials, including organic-bearing aqueous fluid inclusions [4]. The Hayabusa2 spacecraft recently returned samples of C-class asteroid Ryugu to Earth, now being analyzed in labs worldwide. These materials are expected to be dominated by materials similar to C1 and C2 carbonaceous chondrites [5].

Michael Zolensky↗

Mineralogy and Space Weathering of Fine Fraction Recovered from Asteroid (162173) Ryugu

JAXA Hayabusa2 spacecraft brought back 5.4 g of samples from the near-Earth C-type asteroid (162173) Ryugu to Earth on December6th, 2020 [1]. The returned samples give us a unique opportunity to investigate material from the surface of a C-type asteroid that is expected to record space weathering. Here, we report the mineralogy of fine fraction of the Ryugu grains and a variation of their surface features related to space weathering.

T. Noguchi↗

Multimodal Mass Spectrometry Imaging (MSI) of Archean and Jurassic Geologic Samples

Current geochemical analytical techniques such as gas chromatography-mass spectrometry (GC-MS and $G\acute{C}GC-MS$) can effectively determine the composition and structure of the organic biosignatures within a sample but cannot resolve the spatial distribution of organic biosignatures within rocks or sediments. The spatial distribution can be used to determine the character of the organic biosignatures [1], which can be indigenous (deposited with host rocks), non-indigenous (incorporated after deposition via fluid migration), or contaminant. Determining the character of organic biosignatures is critical for ancient samples [2] and will be critical if organics are observed in samples returned from Mars [3].Fs-LDPI-MS has the ability to map organic compounds across the surface of samples at 2 - 10 μm lateral resolution. Furthermore, fs-LDPI-MS can be used to carry out multiple analyses in the same location for micron-scale analysis of previously buried material [4]. We used fs-LDPI-MS to examine a ~164 million year old organic-rich mudstone from SW England (14.2 wt. % total organic carbon) [5] and determined the spatial distribution of likely indigenous components buried below potentially contaminated surface layers.We then used ToF-SIMS to re-analyze the mudstone to directly compare ToF-SIMS to fs-LDPI-MS datasets, and to analyze a series of ~2.7 billion year old geologic samples from Timmins, ON, CA [6]. Ref. [6] previously analyzed the Archean samples and observed a series of archaeal biomarkers, as well as hopanes and steranes. Using ToF-SIMS analysis, we were able to detect hopanes and steranes in the mudstone samples, but not in the Archean samples indicating that the hopanes and steranes are most likely contaminants in the Archean samples. We also did not observe the archaeal biomarkers; however, this may be from the lack of molecular ion preservation during ToF-SIMS.

Pasterski, Michael↗

Mars exploration in the 1990's

Science objectives for a Mars exploration program in the 1990s, set forth by NASA's Committee on Planetary Exploration, are presented. They include: an intensive study of the Martian surface, the exploration of the structure and general circulation of the atmosphere, the exploration of the nature and dynamics of the planet's interior, the nature of Mars's magnetic field, the character of the upper atmosphere and its interaction with the solar wind, and the establishment of the global chemical and physical characteristics of the Martian surface. Several low cost missions, which have been suggested by the Committee for NASA's CORE program, such as the Mars Geoscience Climatology Observer, the Mars Aeronomy Orbiter, and the Mars Surface Network and Surface Probing missions are also covered. Direct Entry-Direct Return and Out-of-Orbit Entry-Orbital Rendezvous and Docking are two versions of a Mars Rover and Sample Return (MRSR) mission discussed in detail. It is concluded that a MRSR mission will require the combination of full Centaur capability, aerocapture at Mars and earth, and direct return to earth to meet major scientific goals. Further studies should be made in orbit assembly, fuel transfer technology, aeromaneuvering, terminal guidance, rover technology, and robotics.

Albee, A. L.↗

Mars Rover/Sample Return mission trade studies

Mission trade studies for a preliminary definition of a flight-separable Mars Rover/Sample Return (MRSR) mission are presented. The MRSR initiative consists of two separate mission elements: a Mars Rover and a Mars Sample Return. Various strategies are discussed for completing the interplanetary portion of the MRSR mission. Five mission options which are characterized by different launch configurations are discussed, and the resulting spacecraft mass needed to accomplish the mission is presented relative to the capabilities of launch vehicles assumed to be available during the timeframe under consideration.

Soldner, John K.↗

Mars Rover/Sample Return mission definition

Mission trade studies for a preliminary definition of a flight-separable Mars Rover/Sample Return (MRSR) mission are presented. The MRSR initiative consists of two separate mission elements: a Mars Rover and a Mars Sample Return. Various strategies are discussed for completing the interplanetary portion of the MRSR mission. Five mission options which are characterized by different launch configurations are discussed, and the resulting spacecraft mass needed to accomplish the mission is presented relative to the capabilities of launch vehicles assumed to be available during the timeframe under consideration.

Friedlander, Alan L.↗

Mars Rover/Sample Return (MRSR) Mission: Mars Rover Technology Workshop

A return to the surface of Mars has long been an objective of NASA mission planners. The ongoing Mars Rover and Sample Return (MRSR) mission study represents the latest stage in that interest. As part of NASA's preparation for a possible MRSR mission, a technology planning workshop was held to attempt to define technology requirements, options, and preliminary plans for the principal areas of Mars rover technology. The proceedings of that workshop are presented.

Source record↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

OSIRIS-REx Entry, Descent, and Landing Performance

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) was the third mission in NASA’s New Frontiers program. OSIRIS-REx launched out of Cape Canaveral, Florida on September 8, 2016, with a science goal to return a minimum of 60 g of a primitive asteroid’s surface, specifically the near-Earth asteroid Bennu. The sample return capsule (SRC) successfully touched down at UTTR on the morning of September 24, 2023. The entry, descent, and landing (EDL) sequence had an off-nominal deployment of the parachute, but the spacecraft safely landed within the pre-flight prediction of the landing ellipse and the payload was safely recovered. This paper discusses the pre-flight EDL modeling and simulation and focus on predictions for EDL operations. Flight observations such as timeline are compared to the predicted timeline produced by the EDL simulation.

EDL↗

OSIRIS-REx Entry, Descent, and Landing Performance

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) was the third mission in NASA’s New Frontiers program. OSIRIS-REx launched out of Cape Canaveral, Florida on September 8, 2016, with a science goal to return a minimum of 60 g of a primitive asteroid’s surface, specifically the near-Earth asteroid Bennu. The sample return capsule (SRC) successfully touched down at UTTR on the morning of September 24, 2023. The entry, descent, and landing (EDL) sequence had an off-nominal deployment of the parachute, but the spacecraft safely landed within the pre-flight prediction of the landing ellipse and the payload was safely recovered. This paper discusses the pre-flight EDL modeling and simulation and focus on predictions for EDL operations. Flight observations such as timeline are compared to the predicted timeline produced by the EDL simulation.

EDL↗