Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

The 2025 Evaluation of Experimental Thermonuclear Reaction Rates (ETR25)

This work describes the formalism for estimating thermonuclear reaction rates for astrophysical applications, emphasizing modern statistical approaches such as Monte Carlo sampling and Bayesian models. We discuss related topics including the calculation of resonance energies from nuclear Q values, indirect estimates of particle partial widths, and matching of reaction rates at elevated temperatures to statistical model results. We have evaluated available experimental data on cross sections, resonance energies and strengths, partial widths, lifetimes, spin-parities, and spectroscopic factors. Based on these results, we have estimated numerical values of 78 experimental charged-particle thermonuclear reaction rates for target nuclei in the A = 2–40 mass region, for temperatures ranging from 1 MK to 10 GK. For each reaction, three rate values are provided: low, median, and high, corresponding to the 16th, 50th, and 84th percentiles, respectively, of the cumulative reaction rate probability density distribution. Additionally, we present the factor uncertainty of each rate at each temperature grid point. These results enable users to sample the reaction rate probability density in nucleosynthesis calculations, facilitating uncertainty estimates of nuclidic abundances. The rates presented here refer to their laboratory values. For use in stellar model simulations, these values need to be corrected for the effects of thermal excitations of the interacting nuclei. For each reaction, we include graphs that illustrate the fractional contributions to the overall reaction rate along with the associated uncertainty. These visuals are designed to assist both stellar modelers and nuclear experimentalists by identifying the primary sources of rate uncertain=^texttx);ty at specific stellar temperatures. A graphical comparison with earlier Monte Carlo rates is also provided.

Nuclear astrophysics↗

Shock-implanted noble gases - An experimental study with implications for the origin of Martian gases in shergottite meteorites

The shock-implantation of gases is studied by artificially shocking whole rock and power samples of terrestrial basalt to pressures of 2-40 GPa. Ar, Kr, Xe, and Ne were implanted into the silicate. It is observed that the amount of implanted gas is linearly proportional to its partial pressure over a pressure range of 0.0001 to 0.1 atmosphere. The fractionation effect in the implanted gas and the gas diffusion properties are examined. The amounts of gas that would have been implanted with 100 percent efficiency are calculated from the measured porosities of the power samples and are compared to observed abundances. It is determined that the implantation efficiencies are approximately 0.5 percent at 2 GPa, 7 percent at 5 GPa, and greater than 50 percent at both 20 and 35 GPa. The experimental data correlate with the shock implantation of Martian gases without mass fractionation into the shock-melted phase of meteorite EETA 79001.

Bogard, Donald D.↗

Accounting for the dispersion in the x ray properties of early-type galaxies

The x ray luminosities of early-type galaxies are correlated with their optical (e.g., blue) luminosities (L sub X approx. L sub B exp 1.6), but the x ray luminosities exhibit considerable scatter for a given optical luminosity L sub B. This dispersion in x ray luminosity is much greater than the dispersion of other properties of early-type galaxies (for a given L sub B), such as luminosity scale-length, velocity dispersion, color, and metallicity. Here, researchers consider several possible sources for the dispersion in x ray luminosity. Some of the scatter in x ray luminosity may result from stellar population variations between galaxies with similar L sub B. Since the x ray emitting gas is from accumulated stellar mass loss, the L sub X dispersion may be due to variations in integrated stellar mass loss rates. Another possible cause of the L sub X dispersion may be variations in the amount of cool material in the galaxies; cool gas may act as an energy sink for the hot gas. Infrared emission may be used to trace such cool material, so researchers look for a correlation between the infrared emission and the x ray emission of early-type galaxies at fixed L sub B. Velocity dispersion variations between galaxies of similar L sub B may also contribute to the L sub X dispersion. The most likely a priori source of the dispersion in L sub X is probably the varying amount of ram-pressure stripping in a range of galaxy environments. The hot gaseous halos of early-type galaxies can be stripped in encounters with other galaxies or with ambient cluster gas if the intracluster gas is sufficiently dense. Researchers find that the most likely cause of dispersion in the x ray properties of early type galaxies is probably the ram-pressure stripping of gaseous halos from galaxies. For a sample of 81 early-type galaxies with x ray luminosities or upper limits derived from Einstein Observatory observations (CFT) researchers calculated the cumulative distribution of angular distances between the x ray sample members and bright galaxies from the Revised Shapley - Ames catalog. Collectively, galaxies with low x ray luminosities (for a given L sub B) tend to be in denser environments than galaxies with higher x ray luminosities.

White, Raymond E., III↗

GUNDAM: a toolkit for fast spatial correlation functions in galaxy surveys

ABSTRACT We describe the capabilities of a new software package to calculate two-point correlation functions (2PCFs) of large galaxy samples. The code can efficiently estimate 3D/projected/angular 2PCFs with a variety of statistical estimators and bootstrap errors, and is intended to provide a complete framework (including calculation, storage, manipulation, and plotting) to perform this type of spatial analysis with large redshift surveys. Gundam implements a very fast skip list/linked list algorithm that efficiently counts galaxy pairs and avoids the computation of unnecessary distances. It is several orders of magnitude faster than a naive pair counter, and matches or even surpass other advanced algorithms. The implementation is also embarrassingly parallel, making full use of multicore processors or large computational clusters when available. The software is designed to be flexible, user friendly and easily extensible, integrating optimized, well-tested packages already available in the astronomy community. Out of the box, it already provides advanced features such as custom weighting schemes, fibre collision corrections and 2D correlations. Gundam will ultimately provide an efficient toolkit to analyse the large-scale structure ‘buried’ in upcoming extremely large data sets generated by future surveys.

Donoso, E.↗

Report on Status of Shipment of High Fluence Austenitic Steel Samples for Characterization and Stress Corrosion Crack Testing

The goal of the Mechanisms of Irradiation Assisted Stress Corrosion Cracking (IASCC) task in the LWRS Program is to conduct experimental research into understanding how multiple variables influence the crack initiation and crack growth in materials subjected to stress under corrosive conditions. This includes understanding the influences of alloy composition, radiation condition, water chemistry and metallurgical starting condition (i.e., previous cold work or heat treatments and the resulting microstructure) has on the behavior of materials. Testing involves crack initiation and growth testing on irradiated specimens of single-variable alloys in simulated Light Water Reactor (LWR) environments, tensile testing, hardness testing, microstructural and microchemical analysis, and detailed efforts to characterize localized deformation. Combined, these single-variable experiments will provide mechanistic understanding that can be used to identify key operational variables to mitigate or control IASCC, optimize inspection and maintenance schedules to the most susceptible materials/locations, and, in the long-term, design IASCC-resistant materials. In support of this research, efforts are currently underway to arrange shipment of “free” high fluence austenitic alloys available through Électricité de France (EDF) for post irradiation testing at the Oak Ridge National Laboratory (ORNL) and IASCC testing at the University of Michigan. These high fluence materials range in damage values from 45 to 125 displacements per atom (dpa). The samples identified for transport to the United States, which include nine, no-cost, 304, 308 and 316 tensile bars, were relocated from the Research Institute of Atomic Reactors (RIAR) in Dimitrovgrad, Ulyanovsk Oblast, Russia, and received at the Halden Reactor in Halden, Norway, on August 23, 2016. ORNL has been notified that a significant amount of work is required to prepare the samples for further shipment to Oak Ridge, Tennessee. The preliminary work for sample shipment between Halden and Oak Ridge includes fabrication of an inner cask sample container, decontamination and preparation of a Type A container, preparation of new activity calculations, all necessary paperwork, and handling. ORNL will continue to work to track progress of sample preparation and shipment status, and to work toward an agreement that covers material shipping costs between the Halden Reactor and the Oak Ridge National Laboratory.

36 MATERIALS SCIENCE↗

The current status of airborne laser fluorosensing

Airborne laser fluorosensors have been used to identify and quantify specific substances in the aquatic environment. It has been shown that the sensor can identify and classify oil films. If the extinction coefficient is known then the thickness of thinner films (less than 20 micrometers) may be calculated. The intensity of the water Raman signal is proportional to the water volume sampled by the sensor and hence an effective attenuation coefficient for the water can be calculated. The same Raman measurement provides the normalization necessary to map chlorophyll and dye concentrations using the intensity of their respective fluorescence signatures.

Oneil, R. A.↗

2D and 3D simulations of damage in 5-grain copper gas gun samples

2D and 3D Hydrocode simulations were done of a gas gun damage experiment involving a 5 grain sample with a polycrystalline flyer with a velocity of about 140 m/s. The simulations were done with the Flag hydrocode and involved explicit meshing of the 5 grains with a single crystal plasticity model and a pressure based damage model. The calculated fields were compared with two cross sections from the recovered sample. The sample exhibited grain boundary cracks at high angle and tilt grain boundaries in the sample but not at a sigma 3 twin boundary. However, the calculation showed large gradients in stress and strain at only the twin boundary, contrary to expectation. This indicates that the twin boundary is quite strong to resist the predicted high gradients and that the calculation needs the addition of a grain boundary fracture mode. The 2D and 3D simulations were compared.

36 MATERIALS SCIENCE↗

Achieving atomic resolution magnetic dichroism by controlling the phase symmetry of an electron probe

The calculations presented here reveal that an electron probe carrying orbital angular momentum is just a particular case of a wider class of electron beams that can be used to measure electron magnetic circular dichroism (EMCD) with atomic resolution. It is possible to obtain an EMCD signal with atomic resolution by simply breaking the symmetry of the electron probe phase front using the aberration-corrected optics of a scanning transmission electron microscope. The probe’s required phase distribution depends on the sample’s magnetic symmetry and crystal structure. The calculations indicate that EMCD signals that use the electron probe’s phase are as strong as those obtained by nanodiffraction methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic properties and loss separation in iron-silicone-MnZn ferrite soft magnetic composites

This paper investigates the magnetic and structural properties of iron-based soft magnetic composites coated with silicone-MnZn ferrite hybrid. The organic silicone resin was added to improve the flexibility of the insulated iron powder and causes better adhesion between particles to increase the mechanical properties. Scanning electron microscopy and distribution maps show that the iron particle surface is covered with a thin layer of silicone-MnZn ferrite. Silicone-MnZn ferrite coated samples have higher permeability when compared with the non-magnetic silicone resin coated compacts. The real part of permeability increases by 34.18% when compared with the silicone resin coated samples at 20 kHz. In this work, a formula for calculating the total loss component by loss separation method is presented and finally the different parts of total losses are calculated. The results show that the eddy current loss coefficient is close to each other for the silicone-MnZn ferrite, silicone resin and MnZn ferrite coated samples (0.0078<k{sub 3}<0.008), but the hysteresis loss coefficient is lower for the silicone-MnZn ferrite coated sample (k{sub 2} =1.4058) in comparison with other samples.

36 MATERIALS SCIENCE↗

Transmission X-ray Diffraction (XRD) Patterns Relevant to the MSL Chemin Amorphous Component: Sulfates And Silicates

The Mars Science Laboratory (MSL) CheMin instrument on the Curiosity rover is a transmission X-ray diffractometer (Co-Kalpha radiation source and a approx.5deg to approx.52deg 2theta range) where the analyzed powder samples are constrained to have discrete particle diameters <150 microns by a sieve. To date, diffraction patterns have been obtained for one basaltic soil (Rocknest (RN)) and four drill fines of coherent rock (John Klein (JK), Cumberland (CB), Windjana (WJ), and Confidence Hills (CH)). The CheMin instrument has detected and quantified the abundance of both primary igneous (e.g., feldspar, olivine, and pyroxene) and secondary (e.g., Ca-sulfates, hematite, akaganeite, and Fe-saponite) minerals. The diffraction patterns of all CheMin samples are also characterized by a broad diffraction band centered near 30deg 2theta and by increasing diffraction intensity (scattering continuum) from approx.15deg to approx.5deg, the 2theta minimum. Both the broad band and the scattering continuum are attributed to the presence of an XRD amorphous component. Estimates of amorphous component abundance, based on the XRD data itself and on mass-balance calculations using APXS data crystalline component chemistry derived from XRD data, martian meteorites, and/or stoichiometry [e.g., 6-9], range from approx.20 wt.% to approx.50 wt.% of bulk sample. The APXSbased calculations show that the amorphous component is rich in volatile elements (esp. SO3) and is not simply primary basaltic glass, which was used as a surrogate to model the broad band in the RN CheMin pattern. For RN, the entire volatile inventory (except minor anhydrite) is assigned to the amorphous component because no volatile-bearing crystalline phases were reported within detection limits [2]. For JK and CB, Fesaponite, basanite, and akaganeite are volatile-bearing crystalline components. Here we report transmission XRD patterns for sulfate and silicate phases relevant to interpretation of MSL-CheMin XRD amorphous components.

Morris, R. V.↗

Absorbed Doses and Risk Estimates of {sup 211}At-MX35 F(ab'){sub 2} in Intraperitoneal Therapy of Ovarian Cancer Patients

Purpose: Ovarian cancer is often diagnosed at an advanced stage with dissemination in the peritoneal cavity. Most patients achieve clinical remission after surgery and chemotherapy, but approximately 70% eventually experience recurrence, usually in the peritoneal cavity. To prevent recurrence, intraperitoneal (i.p.) targeted α therapy has been proposed as an adjuvant treatment for minimal residual disease after successful primary treatment. In the present study, we calculated absorbed and relative biological effect (RBE)-weighted (equivalent) doses in relevant normal tissues and estimated the effective dose associated with i.p. administration of {sup 211}At-MX35 F(ab'){sub 2}. Methods and Materials: Patients in clinical remission after salvage chemotherapy for peritoneal recurrence of ovarian cancer underwent i.p. infusion of {sup 211}At-MX35 F(ab'){sub 2}. Potassium perchlorate was given to block unwanted accumulation of {sup 211}At in thyroid and other NIS-containing tissues. Mean absorbed doses to normal tissues were calculated from clinical data, including blood and i.p. fluid samples, urine, γ-camera images, and single-photon emission computed tomography/computed tomography images. Extrapolation of preclinical biodistribution data combined with clinical blood activity data allowed us to estimate absorbed doses in additional tissues. The equivalent dose was calculated using an RBE of 5 and the effective dose using the recommended weight factor of 20. All doses were normalized to the initial activity concentration of the infused therapy solution. Results: The urinary bladder, thyroid, and kidneys (1.9, 1.8, and 1.7 mGy per MBq/L) received the 3 highest estimated absorbed doses. When the tissue-weighting factors were applied, the largest contributors to the effective dose were the lungs, stomach, and urinary bladder. Using 100 MBq/L, organ equivalent doses were less than 10% of the estimated tolerance dose. Conclusion: Intraperitoneal {sup 211}At-MX35 F(ab'){sub 2} treatment is potentially a well-tolerated therapy for locally confined microscopic ovarian cancer. Absorbed doses to normal organs are low, but because the effective dose potentially corresponds to a risk of treatment-induced carcinogenesis, optimization may still be valuable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Innovative Extension of the EDF Inventory Methodology for Irradiated Graphite Sleeves - 16084

About 17,000 t of EDF irradiated graphite wastes will be produced from the decommissioning of the six French gas-cooled nuclear reactors. Determining the radionuclide content of this graphite is of capital importance for safety purposes and in order to determine the best way to manage them. A method using an identification calculation-measurement process has been proposed in order to assess a radiological inventory as precise as possible and has been validated by ANDRA, the French governmental radioactive waste management agency and by IRSN, the technical support of the French nuclear safety authority. As presented at WM2013, this method is based on (a) radionuclide measurements from sufficient samples from a statistical point of view and (b) activation coefficients calculated from the neutron flux histories of the measured samples. For that purpose, it is important to know the precise location of each measured graphite sample, which is easy with pile sampling. About 2,000 t of EDF irradiated graphite is composed of sleeves which contained fuel cartridges and they have been stored in silos of St-Laurent site. The general method needs to know the precise history including neutron flux of any sampled sleeve. As there is no possibility to individually identify sleeves, such a requirement on sleeves in a silo is impossible. The paper presents both the general method for piles and an innovative way to replace that knowledge for long lived radionuclide of irradiated sleeves. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculating Probability Densities with Homotopy and Applications to Particle Filters

In this work, we explore a homotopy sampling procedure and its generalization, loosely based on importance sampling, known as annealed importance sampling. The procedure makes use of a known probability distribution to find, via homotopy, the unknown normalization of a target distribution, as well as samples of the target distribution. We propose a reformulation of the method that leads to a rejection sampling alternative. Estimates of the error as a function of homotopy stages and sample averages are derived for the algorithmic version of the method. These estimates are useful in making computational efficiency decisions on how the calculation should proceed, given a computer architecture. Consideration is given to how the procedure can be adapted to Bayesian stationary and nonstationary estimation problems. The connection between homotopy sampling and thermodynamic integration is made. Emphasis is placed on the non-stationary problems, and in particular, on a sequential estimation technique known as particle filtering. It is shown that a modification of the particle filter framework to include the homotopy process can improve the computational robustness of particle filters.

97 MATHEMATICS AND COMPUTING↗

THE ALFALFA H α SURVEY. I. PROJECT DESCRIPTION AND THE LOCAL STAR FORMATION RATE DENSITY FROM THE FALL SAMPLE

The ALFALFA H α survey utilizes a large sample of H i-selected galaxies from the ALFALFA survey to study star formation (SF) in the local universe. ALFALFA H α contains 1555 galaxies with distances between ∼20 and ∼100 Mpc. We have obtained continuum-subtracted narrowband H α images and broadband R images for each galaxy, creating one of the largest homogeneous sets of H α images ever assembled. Our procedures were designed to minimize the uncertainties related to the calculation of the local SF rate density (SFRD). The galaxy sample we constructed is as close to volume-limited as possible, is a robust statistical sample, and spans a wide range of galaxy environments. In this paper, we discuss the properties of our Fall sample of 565 galaxies, our procedure for deriving individual galaxy SF rates, and our method for calculating the local SFRD. We present a preliminary value of log(SFRD[ M {sub ⊙} yr{sup −1} Mpc{sup −3}]) = −1.747 ± 0.018 (random) ±0.05 (systematic) based on the 565 galaxies in our Fall sub-sample. Compared to the weighted average of SFRD values around z ≈ 2, our local value indicates a drop in the global SFRD of a factor of 10.2 over that lookback time.

79 ASTRONOMY AND ASTROPHYSICS↗

Model atmospheres for M (sub)dwarf stars. 1: The base model grid

We have calculated a grid of more than 700 model atmospheres valid for a wide range of parameters encompassing the coolest known M dwarfs, M subdwarfs, and brown dwarf candidates: 1500 less than or equal to T(sub eff) less than or equal to 4000 K, 3.5 less than or equal to log g less than or equal to 5.5, and -4.0 less than or equal to (M/H) less than or equal to +0.5. Our equation of state includes 105 molecules and up to 27 ionization stages of 39 elements. In the calculations of the base grid of model atmospheres presented here, we include over 300 molecular bands of four molecules (TiO, VO, CaH, FeH) in the JOLA approximation, the water opacity of Ludwig (1971), collision-induced opacities, b-f and f-f atomic processes, as well as about 2 million spectral lines selected from a list with more than 42 million atomic and 24 million molecular (H2, CH, NH, OH, MgH, SiH, C2, CN, CO, SiO) lines. High-resolution synthetic spectra are obtained using an opacity sampling method. The model atmospheres and spectra are calculated with the generalized stellar atmosphere code PHOENIX, assuming LTE, plane-parallel geometry, energy (radiative plus convective) conservation, and hydrostatic equilibrium. The model spectra give close agreement with observations of M dwarfs across a wide spectral range from the blue to the near-IR, with one notable exception: the fit to the water bands. We discuss several practical applications of our model grid, e.g., broadband colors derived from the synthetic spectra. In light of current efforts to identify genuine brown dwarfs, we also show how low-resolution spectra of cool dwarfs vary with surface gravity, and how the high-regulation line profile of the Li I resonance doublet depends on the Li abundance.

Allard, France↗

ASSESSMENT OF SYSTEMATIC CHROMATIC ERRORS THAT IMPACT SUB-1% PHOTOMETRIC PRECISION IN LARGE-AREA SKY SURVEYS

Meeting the science goals for many current and future ground-based optical large-area sky surveys requires that the calibrated broadband photometry is both stable in time and uniform over the sky to 1% precision or better. Past and current surveys have achieved photometric precision of 1%–2% by calibrating the survey’s stellar photometry with repeated measurements of a large number of stars observed in multiple epochs. The calibration techniques employed by these surveys only consider the relative frame-by-frame photometric zeropoint offset and the focal plane position-dependent illumination corrections, which are independent of the source color. However, variations in the wavelength dependence of the atmospheric transmission and the instrumental throughput induce source color-dependent systematic errors. These systematic errors must also be considered to achieve the most precise photometric measurements. In this paper, we examine such systematic chromatic errors (SCEs) using photometry from the Dark Energy Survey (DES) as an example. We first define a natural magnitude system for DES and calculate the systematic errors on stellar magnitudes when the atmospheric transmission and instrumental throughput deviate from the natural system. We conclude that the SCEs caused by the change of airmass in each exposure, the change of the precipitable water vapor and aerosol in the atmosphere over time, and the non-uniformity of instrumental throughput over the focal plane can be up to 2% in some bandpasses. We then compare the calculated SCEs with the observed DES data. For the test sample data, we correct these errors using measurements of the atmospheric transmission and instrumental throughput from auxiliary calibration systems. The residual after correction is less than 0.3%. Moreover, we calculate such SCEs for Type Ia supernovae and elliptical galaxies and find that the chromatic errors for non-stellar objects are redshift-dependent and can be larger than those for stars at certain redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid Machine Learning for Scanning Near-Field Optical Spectroscopy

The underlying physics behind an experimental observation often lacks a simple analytical description. This is especially the case for scanning probe microscopy techniques, where the interaction between the probe and the sample is nontrivial. Realistic modeling to include the details of the probe is always exponentially more difficult than its "spherical cow" counterparts. On the other hand, a well-trained artificial neural network based on real data can grasp the hidden correlation between the signal and sample properties. In this work, we show that, via a combination of model calculation and experimental data acquisition, a physics-infused hybrid neural network can predict the tip-sample interaction in the widely used scattering-type scanning near-field optical microscope. This hybrid network provides a long-sought solution for accurate extraction of material properties from tip-specific raw data. The methodology can be extended to other scanning probe microscopy techniques as well as other data-oriented physical problems in general.

36 MATERIALS SCIENCE↗

Structural and optical analysis on europium doped AZrO{sub 3} (A=Ba, Ca, Sr) phosphor for display devices application

Behavior displayed by europium doped AZrO{sub 3} phosphor which was synthesized by solid state reaction method. For synthesis of BaZrO{sub 3}, SrZrO{sub 3} and CaZrO{sub 3} phosphor with fixed concentration of europium ion was calcination at 1000°C and sintered at 1300°C following intermediate grinding. Synthesized sample was characterized by X-ray diffraction analysis and crystallite sized was calculated by Scherer’s formula. From PL spectra of prepared phosphors shows intense emission centred at 612nm (red emission) with high intensity for SrZrO{sub 3}:Eu{sup 3+}. For europium doped BaZrO{sub 3} and CaZrO{sub 3} (613nm) phosphor shows less intense PL spectra as compared to SrZrO{sub 3}:Eu{sup 3+}. The strong emission peak of AZrO{sub 3}:Eu{sup 3+} phosphor is due to forced electric dipole transition of {sup 5}D{sub 0} to {sup 7}F{sub 2} centered at 612 and 613nm. It is characteristic red emission for europium ion. The excitation spectra of AZrO{sub 3}:Eu{sup 3+} phosphor mainly consists of the charge transfer and (CTB) of Eu{sup 3+} located in 200–350 nm centred at 254nm. The present phosphors can act as single host for red light emission in display devices. The CIE coordinates were calculated by Spectrophotometric method using the spectral energy distribution of the AZrO{sub 3}:Eu{sup 3+} sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗