Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Layer specific optical band gap measurement at nanoscale in MoS{sub 2} and ReS{sub 2} van der Waals compounds by high resolution electron energy loss spectroscopy

Layer specific direct measurement of optical band gaps of two important van der Waals compounds, MoS{sub 2} and ReS{sub 2}, is performed at nanoscale by high resolution electron energy loss spectroscopy. For monolayer MoS{sub 2}, the twin excitons (1.8 and 1.95 eV) originating at the K point of the Brillouin zone are observed. An indirect band gap of 1.27 eV is obtained from the multilayer regions. Indirect to direct band gap crossover is observed which is consistent with the previously reported strong photoluminescence from the monolayer MoS{sub 2}. For ReS{sub 2}, the band gap is direct, and a value of 1.52 and 1.42 eV is obtained for the monolayer and multilayer, respectively. The energy loss function is dominated by features due to high density of states at both the valence and conduction band edges, and the difference in analyzing band gap with respect to ZnO is highlighted. Crystalline 1T ReS{sub 2} forms two dimensional chains like superstructure due to the clustering between four Re atoms. The results demonstrate the power of HREELS technique as a nanoscale optical absorption spectroscopy tool.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Individual heteroatom identification with X-ray spectroscopy

Individual heteroatoms in nanoscale materials often play a pivotal role in materials properties. To obtain maximum control over materials properties, researchers must be able to detect and identify diverse heteroatoms in samples with varying thickness and composition. Here, we demonstrate the identification of individual Si, S, P, and Ca heteroatoms in two-phase carbonaceous nanoscale mixtures with energy dispersive X-ray spectroscopy in a scanning transmission electron microscope. In order to fully demonstrate the robustness of the technique and the potential advantages over electron energy loss spectroscopy for single-atom speciation, no a priori constraint was placed on the sample thickness or types of heteroatom species. The various heteroatoms were identified with X-ray spectrum collection times ranging from 8 to 57 s, and normalized count rates of 0.096–0.007 counts s{sup −1} pA{sup −1}. The lowest times/highest effective count rates were achieved by maximizing the effective dwell time on the atom, through minimizing the oversampling area of the electron beam raster.

36 MATERIALS SCIENCE↗

Perspective: The first ten years of broadband chirped pulse Fourier transform microwave spectroscopy

Since its invention in 2006, the broadband chirped pulse Fourier transform spectrometer has transformed the field of microwave spectroscopy. The technique enables the collection of a ≥10 GHz bandwidth spectrum in a single shot of the spectrometer, which allows broadband, high-resolution microwave spectra to be acquired several orders of magnitude faster than what was previously possible. We report on the advantages and challenges associated with the technique and look back on the first ten years of chirped pulse Fourier transform spectroscopy. In addition to enabling faster-than-ever structure determination of increasingly complex species, the technique has given rise to an assortment of entirely new classes of experiments, ranging from chiral sensing by three-wave mixing to microwave detection of multichannel reaction kinetics. Yet, this is only the beginning. Future generations of microwave experiments will make increasingly creative use of frequency-agile pulse sequences for the coherent manipulation and interrogation of molecular dynamics.

47 OTHER INSTRUMENTATION↗

Probing the CZTS/CdS heterojunction utilizing photoelectrochemistry and x-ray absorption spectroscopy

The importance of renewable resources is becoming more and more influential on research due to the depletion of fossil fuels. Cost-effective ways of harvesting solar energy should also be at the forefront of these investigations. Cu 2 ZnSnS 4 (CZTS) solar cells are well within the frame of these goals, and a thorough understanding of how they are made and processed synthetically is crucial. The CZTS/CdS heterojunction was examined using photoelectrochemistry and synchrotron radiation (SR) spectroscopy. These tools provided physical insights into this interface that was formed by the electrophoretic deposition of CZTS nanocrystals and chemical bath deposition (CBD) of CdS for the respective films. It was discovered that CBD induced a change in the local and long range environment of the Zn in the CZTS lattice, which was detrimental to the photoresponse. X-ray absorption near-edge structures and extended X-ray absorption fine structures (EXAFSs) of the junction showed that this change was at an atomic level and was associated with the coordination of oxygen to zinc. This was confirmed through FEFF fitting of the EXAFS and through IR spectroscopy. It was found that this change in both photoresponse and the Zn coordination can be reversed with the use of low temperature annealing. Investigating CZTS through SR techniques provides detailed structural information of minor changes from the zinc perspective.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revisiting heat treatment and surface activation of GaAs photocathodes: In situ studies using scanning tunneling microscopy and photoelectron spectroscopy

The lifetime of GaAs photocathodes in polarized electron guns is limited due to the delicate activation layer. An atomically clean and smooth GaAs surface is needed to deposit a robust activation layer, such as Cs 2 Te, with longer lifetime compared to traditional (Cs,O) activation. A previous experiment with Cs 2 Te activation on GaAs used heat cleaning temperatures around 400°C to avoid an increase in surface roughness [Bae et al., Appl. Phys. Lett. 112, 154101 (2018)]. Furthermore, high-temperature heat cleaning around 580°C, which results in a relatively contamination-free surface, could be one possible way to improve quantum efficiency. However, one should be cautious about surface roughness degradation during high-temperature heat cleaning. In this paper, we report results of surface roughness measurements on native, heat cleaned, and (Cs,O) activated GaAs photocathodes under vacuum. The results, measured by ultrahigh vacuum scanning tunneling microscopy, show that the surface roughness improves as the heat cleaning temperature is increased, by at least a factor of three for 580°C heat cleaning, compared to the native sample. Activation with (Cs,O) is shown to increase surface roughness by a factor of four compared to a 580°C heat cleaned sample. This confirms that high-temperature heat cleaning can be useful for depositing good quality robust activation layers on GaAs. Additionally, we also report chemical analysis for each step of preparation for p-doped GaAs photocathodes using X-ray photoelectron spectroscopy (XPS), angle-resolved XPS, and ultraviolet photoelectron spectroscopy. Our results indicate that the (Cs,O) activation layer forms a sandwich structure consists of Cs and oxygen. We found no formation of any specific compound such as Cs 2 O or Cs 11 O 3 .

43 PARTICLE ACCELERATORS↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Lattice and electronic structure of ScN observed by angle-resolved photoemission spectroscopy measurements

Scandium nitride (ScN) has recently attracted much attention for its potential applications in thermoelectric energy conversion, as a semiconductor in epitaxial metal/semiconductor superlattices, as a substrate for GaN growth, and alloying it with AlN for 5G technology. This study was undertaken to better understand its stoichiometry and electronic structure. ScN (100) single crystals 2 mm thick were grown on a single crystal tungsten (100) substrate by a physical vapor transport method over a temperature range of 1900–2000 °C and a pressure of 20 Torr. The core level spectra of Sc 2p 3/2,1/2 and N 1s were obtained by x-ray photoelectron spectroscopy (XPS). The XPS core levels were shifted by 1.1 eV toward higher values as the [Sc]:[N] ratio varied from 1.4 at 1900 °C to ~1.0 at 2000 °C due to the higher binding energies in stoichiometric ScN. Angle-resolved photoemission spectroscopy measurements confirmed that ScN has an indirect bandgap of ~1.2 eV.

42 ENGINEERING↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Molecular axis distribution moments in ultrafast transient absorption spectroscopy: A path toward ultrafast quantum state tomography

In ultrafast time-resolved experiments with gas phase molecules, the alignment of the molecular axis relative to the polarization of the interacting laser pulses plays a crucial role in determining the dynamics following this light–matter interaction. The molecular axis distribution is influenced by the interacting pulses and is intrinsically linked to the electronic coherences of the excited molecules. However, in typical theoretical calculations of such interactions, the signal is either calculated for a single molecule in the molecular frame or averaged over all possible molecular orientations to compare with the experiment. Such averaging removes information about anisotropy in the molecular-axis distribution, even though anisotropic contributions can play a significant role in the measured experimental signal. Here, we calculate the laboratory frame transient electronic first-order polarization [P (1) ] spectra in terms of separated molecular frame and laboratory frame quantities. The laboratory frame polarizations are compared with orientation-averaged quantum master equation calculations, demonstrating that orientation-averaging captures only the isotropic contributions. We show that our formalism also allows us to evaluate the anisotropic contributions to the spectrum. Lastly, we discuss the application of this approach to achieve ultrafast quantum state tomography using transient absorption spectroscopy and field observables in nonlinear spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Intracavity laser spectroscopy by using a Fe{sup 2+}:ZnSe laser

A Fe{sup 2+}:ZnSe laser emitting in the spectral range between 3.77 and 5.05 {mu}m is used for the first time for intracavity laser spectroscopy. The intracavity absorption spectra of methane in the 4.1-{mu}m region are recorded at different instants of lasing (0-80 {mu}s) and the dynamics of spectral holes during lasing is investigated. It is found that an intracavity absorption signal linearly increases with time during lasing in the time range from 0 to 80 {mu}s, which provides the effective absorption length up to 24 km. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the absorption line profiles of water vapour isotopomers at 1.39 {mu}m using the methods of diode laser spectroscopy

The issues related to high-precision measurement of the absorption line profiles of water vapour and its isotopomers using the methods of diode laser spectroscopy in the near IR range aimed at the analysis and detection of greenhouse gases are considered. The absorption line shape of H{sub 2}{sup 16}O is investigated as a function of pressure of different buffer gases. The influence of the instrument function of the diode laser (DL) on the precision of measuring the line profile is studied. From fitting the profile of Doppler-broadened H{sub 2}{sup 16}O absorption line to a model profile the lasing line width of the DL with a fibre pigtail is determined. The frequencies and intensities of absorption lines of water isotopomers H{sub 2}{sup 16}O, H{sub 2}{sup 17}O, H{sub 2}{sup 18}O, and HDO are measured in the range of DL oscillation. Analytical spectral regions are chosen for distant probing of water vapour using an airborne lab. (laser spectroscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermometry of an open spatially inhomogeneous flame by diode laser absorption spectroscopy

Features of a single-beam variant of diode laser absorption spectroscopy (DLAS) used for temperature measurements in a spatially inhomogeneous hot zone are studied. A flame temperature of a commercial burner is measured by using water molecule absorption lines. The flame is probed by a diode laser radiation at various heights and in various directions. The correctness of DLAS measurement results is verified by comparing DLAS data with temperatures measured by the method of coherent anti-Stokes scattering (CARS). It is shown that in homogeneous flame domains the temperatures obtained by both the methods coincide. Temperature inhomogeneity along the probe beam direction is a principal problem of DLAS, in which case the method yields information about some effective temperature along the light trace. The difference in data obtained by DLAS and CARS is estimated. In probing traces with temperature gradients the difference reaches 700 K. Possibilities of accounting for temperature inhomogeneities along the trace in DLAS measurements are discussed. A method of differential spectra is suggested, which in certain conditions can provide substantially better coincidence of results for the two methods. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-correlation analysis of X-ray photon correlation spectroscopy to extract rotational diffusion coefficients

Coefficients for translational and rotational diffusion characterize the Brownian motion of particles. Emerging X-ray photon correlation spectroscopy (XPCS) experiments probe a broad range of length scales and time scales and are well-suited for investigation of Brownian motion. While methods for estimating the translational diffusion coefficients from XPCS are well-developed, there are no algorithms for measuring the rotational diffusion coefficients based on XPCS, even though the required raw data are accessible from such experiments. In this paper, we propose angular-temporal cross-correlation analysis of XPCS data and show that this information can be used to design a numerical algorithm (Multi-Tiered Estimation for Correlation Spectroscopy [MTECS]) for predicting the rotational diffusion coefficient utilizing the cross-correlation: This approach is applicable to other wavelengths beyond this regime. We verify the accuracy of this algorithmic approach across a range of simulated data.

97 MATHEMATICS AND COMPUTING↗

An investigation of aqueous ammonium nitrate aerosols with soft X-ray spectroscopy

Aqueous aerosols are important in atmospheric chemistry, drug delivery, and human health. X-ray photoelectron spectroscopy (XPS), a surface-sensitive technique and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy which informs on the bulk, is deployed to study the solvation of ammonium nitrate (NH 4 NO 3 ). Aerosolised solutions of NH 4 NO 3 were introduced into a photoelectron spectrometer via an aerodynamic lens, and interrogated with soft X-ray photons, the resulting electrons were imaged via velocity map imaging. Density functional theory calculations were performed to compare with the measured binding energies of NH 4 + and NO 3 - solvated in water. The results reveal that the nitrate anion has a slight propensity for the surface, while both ammonium and nitrate ions are present in equal measure in the bulk.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural model of homogeneous As–S glasses derived from Raman spectroscopy and high-resolution XPS

The structure of homogeneous bulk As x S 100- x (25 ≤ x ≤ 42) glasses, prepared by the conventional rocking–melting–quenching method, was investigated using high-resolution X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. It is shown that the main building blocks of their glass networks are regular AsS 3/2 pyramids and sulfur chains. In the S-rich domain, the existence of quasi-tetrahedral (QT) S = As(S 1/2 ) 3 units is deduced from XPS data, but with a concentration not exceeding ~3–5% of total atomic sites. Therefore, QT units do not appear as primary building blocks of the glass backbone in these materials, and an optimally-constrained network may not be an appropriate description for glasses when x < 40. Finally, it is shown that, in contrast to Se-based glasses, the ‘chain-crossing’ model is only partially applicable to sulfide glasses.

36 MATERIALS SCIENCE↗