At least 1,423 records · Page 79

Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry

Using contemporary theory for ion mobility spectrometry (IMS), gas-phase ion mobilities within a trapped ion mobility-mass spectrometer (TIMS) are not easily deduced using first principle equations due to non-linear pressure changes and consequently variations in E/N. It is for this reason that prior literature values have traditionally been used for TIMS calibration. Additionally, given that verified mobility standards currently do not exist and the that the exact conditions used to measure reported literature values may not always represent the environment within the TIMS, a direct approach to validating the behavior of the TIMS system is warranted. A calibration procedure is presented where an ambient pressure, ambient temperature, two-gate, printed circuit board drift-tube IMS (PCBIMS) is coupled to the front of a TIMS allowing reduced mobilities to be directly measured on the same instrument as the TIMS. These measured mobilities were used to evaluate the TIMS calibration procedure which correlates reduced mobility and TIMS elution voltages with literature values. When using the measured PCBIMS-reduced mobilities of tetraalkyl ammonium salts and tune mix for TIMS calibration of the alkyltrimethyl ammonium salts, the percent error is less than 1% as compared with using the reported literature K{sub 0} values where the percent error approaches 5%. This method provides a way to obtain accurate reference mobilities for ion mobility techniques that require a calibration step (i.e., TIMS and TWAVE). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a large area neutron sensitive anger camera

We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3 ) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w (F) values

42 ENGINEERING↗

Isotope-resolved atomic beam laser spectroscopy of natural uranium

Here, we present our results on the development of a technique for conducting laser absorption spectroscopy of uranium in a collimated atomic beam using a compact and potentially fieldable device. A solid natural uranium metal sample is vaporized in a modest vacuum of several mTorr via resistive heating of a tantalum foil micro-crucible. A temperature of over 2000 °C is reached by applying only 200 W of electrical power to the crucible. At this temperature, the vapor pressure of uranium is large enough to generate a stable atomic beam. A diode laser is tuned around the 861.031 nm uranium transition, which allows the observation of absorption bands from both the 238 U and 235 U isotopes. The isotopic composition of uranium Standard Reference Material 960 is obtained from the absorption signal, in excellent agreement with the nominal value. In conclusion, our approach can be readily applied to the isotopic analysis of other actinides, and it is expected to lead to the development of compact, fieldable instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of heavy metal pollution in Zonguldak (Turkey) by moss analysis (hypnum cupressiforme)

This paper explores the first attempt at determining the levels of atmospheric heavy metal contamination in the Zonguldak province through the analysis of moss (Hypnum cupressiforme Hedw.). Sampling was performed at 24 sites after a wet period to avoid contamination from soil compounds in the province. Dried samples, which were unwashed but cleaned of soil particles and other extraneous material, were digested with HNO{sub 3}/HClO{sub 4}. Concentrations of heavy metals (Fe, Cu, Pb, Cr, Co, Ni, and As) were analyzed by ICP-OES to estimate the geographic distribution of the atmospheric heavy metal depositions. The general order of the concentrations of the heavy metal content in Hypnum cupressiforme Hedw. was observed to be Fe > Pb > Cu > Ni > Cr > As > Co. Mean levels of the measured elements were higher when compared to European levels. Arsenic, iron, and chromium were the most elevated elements when compared with European data. The mean concentrations of these elements in the studied area were 8.3 (Co), 6.7 (Fe), 5.2 (Cr), 4.6 (As), and 2.7 (Ni) times the background levels of the reference site (C3). Among the studied heavy metals, only lead showed little variation in measured values due to traffic in the area. Main sources of increased heavy metal content of the moss samples were found to be: I) the Catalagzi Power Plant (CATES); ii) the Eregli Iron-Steel Plant (ERDEMIR); iii) space heating; and iv) traffic-related emissions. Results are presented in the form of color-scaled contour maps using a Geographic Information System (GIS)-based mapping technique.

01 COAL, LIGNITE, AND PEAT↗

Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems

Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup.

36 MATERIALS SCIENCE↗

SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures

Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system. Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.

60 APPLIED LIFE SCIENCES↗

Studies of dijet transverse momentum balance and pseudorapidity distributions in pPb collisions at $\sqrt{s_{\mathrm{NN}}} = 5.02$ $\,\text {TeV}$

Dijet production has been measured in pPb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. A data sample corresponding to an integrated luminosity of 35 inverse-nanobarns was collected using the Compact Muon Solenoid detector at the Large Hadron Collider. The dijet transverse momentum balance, azimuthal angle correlations, and pseudorapidity distributions are studied as a function of the transverse energy in the forward calorimeters ($E_T^{4\lt |\eta| \lt 5.2}$). For pPb collisions, the dijet transverse momentum ratio and the width of the distribution of dijet azimuthal angle difference are comparable to the same quantities obtained from a simulated pp reference and insensitive to $E_T^{4\lt |\eta| \lt 5.2}$. In contrast, the mean value of the dijet pseudorapidity is found to change monotonically with increasing $E_T^{4\lt |\eta| \lt 5.2}$, indicating a correlation between the energy emitted at large pseudorapidity and the longitudinal motion of the dijet frame. As a result, the pseudorapidity distribution of the dijet system is compared with next-to-leading-order perturbative QCD predictions obtained from both nucleon and nuclear parton distribution functions, and the data more closely match the latter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power Index Tables for Burning D-T and D-D Plasma

The thermonuclear fusion reactivities for D-T and D-D can be expressed as a power law of ion temperature (keV). It will be shown that the product of ion temperature and the ratio of the first derivative of the reactivity to the reactivity is the power index. Tabled values of the power index, as a function of ion temperature, T , are presented for reference. A connection to gamma diagnostics for fusion is briefly introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equivalency Factors and Mixed Isotope Subcritical Limits in H-Canyon [Slides]

Accurate references and documentation are of upmost importance, especially with the current workforce makeup. Tribal knowledge is likely to be lost with turnover. Using a questioning attitude is a great way to find gaps in existing analysis and “normal practices.” Most of the references reviewed are from the 1970’s, with the most recent authored in 1994. Many of these references have been revised and/or superseded in the years since. Though safe, many of the values are likely overconservative, as improvements with modeling and additional critical experiments have been performed in the years since. It would be prudent to reevaluate, clarify, and simplify the values used in H-Canyon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduced LCoE CSP Through Utilizing Process Gas Lubricated Bearings in Oil-Free Drivetrains

The GE Research team proposed to advance the TRL level of process lubricated gas bearings from TRL3 based on the DE-EE0007109 program to TRL5 addressing a critical risk item that radial gas bearings can provide satisfactory rotordynamic performance in supporting a representative rotor for sCO2 Power Cycles. The ability to apply process lubricated gas bearings can provide cost savings with reduction of the associated lube oil systems and an efficiency benefit worth 2% efficiency for the turbomachinery configuration first presented in DE-EE005804. The process lubricated gas bearings are enablers for advanced hermetically sealed configurations that have the potential for significant advancement in sCO2 Power Cycles for CSP applications including the 2% efficiency increase referred to above in addition to OPEX savings with no need to refill the CO2 valued at 60k USD/yr and cost reductions of 50 USD/kWe all leading to a potential 0.95¢/kWh reduction positively impacting CSP goals.

14 SOLAR ENERGY↗

Multi-Temporal Predictive Modelling of Sorghum Biomass Using UAV-Based Hyperspectral and LiDAR Data

High-throughput phenotyping using high spatial, spectral, and temporal resolution remote sensing (RS) data has become a critical part of the plant breeding chain focused on reducing the time and cost of the selection process for the “best” genotypes with respect to the trait(s) of interest. In this paper, the potential of accurate and reliable sorghum biomass prediction using visible and near infrared (VNIR) and short-wave infrared (SWIR) hyperspectral data as well as light detection and ranging (LiDAR) data acquired by sensors mounted on UAV platforms is investigated. Predictive models are developed using classical regression-based machine learning methods for nine experiments conducted during the 2017 and 2018 growing seasons at the Agronomy Center for Research and Education (ACRE) at Purdue University, Indiana, USA. The impact of the regression method, data source, timing of RS and field-based biomass reference data acquisition, and the number of samples on the prediction results are investigated. R2 values for end-of-season biomass ranged from 0.64 to 0.89 for different experiments when features from all the data sources were included. Geometry-based features derived from the LiDAR point cloud to characterize plant structure and chemistry-based features extracted from hyperspectral data provided the most accurate predictions. Evaluation of the impact of the time of data acquisition during the growing season on the prediction results indicated that although the most accurate and reliable predictions of final biomass were achieved using remotely sensed data from mid-season to end-of-season, predictions in mid-season provided adequate results to differentiate between promising varieties for selection. The analysis of variance (ANOVA) of the accuracies of the predictive models showed that both the data source and regression method are important factors for a reliable prediction; however, the data source was more important with 69% significance, versus 28% significance for the regression method.

09 BIOMASS FUELS↗

IBM system/360 assembly language interval arithmetic software

Computer software designed to perform interval arithmetic is described. An interval is defined as the set of all real numbers between two given numbers including or excluding one or both endpoints. Interval arithmetic consists of the various elementary arithmetic operations defined on the set of all intervals, such as interval addition, subtraction, union, etc. One of the main applications of interval arithmetic is in the area of error analysis of computer calculations. For example, it has been used sucessfully to compute bounds on sounding errors in the solution of linear algebraic systems, error bounds in numerical solutions of ordinary differential equations, as well as integral equations and boundary value problems. The described software enables users to implement algorithms of the type described in references efficiently on the IBM 360 system.

Phillips, E. J.↗

Hot and cold atmospheres for Vandenberg AFB, California (1973 version)

Extreme atmospheres, pertaining to summer (hot) and winter (cold) conditions for Vandenberg Air Force Base, California, are presented from 0- to 90-km altitudes. Computed values of pressure, e, kinetic temperature, virtual temperature, density, and relative differences (percentages from Vandenberg Reference Atmosphere, 1971 (VRA 71)) of the atmospheric parameters versus altitude are tabulated in increments of 250 m. Hydrostatic and gas law equations were used in conjunction with radiosonde and rocketsonde thermodynamic data in determining the vertical structure of the two atmospheric models. The summer-type density profile deviated from -9.0 percent (of the VRA-71) at the ground to 28.4 percent at 74.5-km altitude. The winter density profile went from 5.2 percent at the surface to -31.4 percent at 72 km.

Johnson, D. L.↗

Helium abundance of the sun.

Critical review of the four methods that have been used to estimate the ratio of helium to hydrogen in the sun - the solar neutrino flux, spectral intensity of helium lines in prominences and the chromosphere, elemental abundance of solar cosmic rays, and variations of solar wind He/H. At present the measured value for the neutrino flux cannot be explained by any of the theoretical models of the sun, and thus the neutrino measurements cannot yield an estimate of He/H. Helium line intensity measurements give the most accurate values for He/H now available - i.e., 5 to 8% helium by number. However, these results refer to the chromosphere and prominences only, and questions of spatial and temporal variations of the observed quantities and of the inferred helium abundances have not yet been dealt with adequately.

Hirshberg, J.↗

A few ways of calculating the similarity parameter kappa* for real gases

In connection with the question on the applicability of test results obtained from cryogenic wind tunnels to the large-scale model the similarity parameter is referred to. A simple method is given for calculating the similarity parameter. From the numerical values obtained it can be deduced that nitrogen behaves practically like an ideal gas when it is close to the saturation point and in a pressure range up to 4 bar. The influence of this parameter on the pressure distribution of a supercritical profile confirms this finding.

Lorenz-Meyer, W.↗

Integrated energy management study. Energy efficient transport program

The Integrated Energy Management (IEM) Study investigated the practicality and feasibility of a closed-loop energy management system for transport aircraft. The study involved: (1) instrumentation and collection of in-flight data for a United Airlines 727-200 flying 80 revenue flights throughout the United Airlines network,(2) analysis of the in-flight data to select representative city pairs and establish operational procedures employed in flying a reference flight profile, (3) simulation of the reference profile in a fast-time model to verify the model and establish performance values against which to measure IEM benefits, (4) development of IEM algorithms, and (5) assessment of the IEM concept.

Source record↗

The ultraviolet cross-sections of ozone. I. The measurements. II - Results and temperature dependence

Absorption cross-sections of ozone have been measured over the range 230 nm to 350 nm, and for temperatures 200 K to 300 K, with improved photometric accuracy and spectral resolution. These measurements are referred to the cross-section at the 253.65 nm mercury line by the Hearn value (1961), 1147 x 10 to the -20th/sq cm, and show an internal consistency of + or - 1 percent. Tables of ozone absorption cross-section in the ultraviolet have been prepared for intervals of 0.05 nm over the range 245 to 340 nm. at each wavelength entry in the table a set of coefficients has been derived that permits the cross-section to be computed as a function of temperature, between 200 K and 300 K, with an accuracy of 1 percent.

Bass, A. M.↗

Correlation-based technique for automated tunable diode laser scan stabilization

A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.

May, Randy D.↗