Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Testing the Jump Finding Code for NEXUS Qubit Analysis

At Fermilab, the NEXUS dilution refrigerator is repeating the same experiment from Wilen et al. 1 underground to further investigate the effect of ionizing radiation and cosmic ray muons on qubit decoherence. This refrigerator is 100m underground in the MINOS cavern to significantly lower the incident rate of cosmic ray muons, meaning the majority of incidents is due to ionizing radiation. To gain a better understanding of how the rate of ionizing radiation affects the qubits, we use 4 radiation configurations to collect data from the chip. In this work, we examine the efficiency of our jump detection code to find jumps of various sizes. We do so using simulated data with a known number of injected jumps of known sizes. These jumps are charge offsets of the qubit, thought to be due to quasiparticle poisoning. To test this, we run the jump finding code on an array of simulated data in which two main parameters, the smoothing factor and the threshold at which a charge offset is considered a jump, are changed to test an array of these parameters. We then perform a χ2 analysis to find the best combination of these two parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Machine Learning Based Prediction of Airflow Maldistribution in A-Type Heat Exchangers

Airflow maldistribution is one of the primary causes of performance degradation in air-to refrigerant heat exchangers (HX) and has been shown to decrease heat transfer by as much as 35%. As a result, many units are oversized to meet the target capacity, resulting in increased system cost and refrigerant charge. Several studies have explored how characteristics like package type and HX geometry impact the flow profile, but results are restricted to a limited range of parameters and cannot be extrapolated to new designs. In this work, a machine learning (ML) model is trained to predict the inlet flow profile of dry air entering A-type HXs across a broad range of geometries and conditions. Flow profiles are generated using a porous media CFD model and used to train an Artificial Neural Network (ANN) which exhibits maximum and average relative L2 norm errors of 0.48 and 0.05. Additionally, these predictions take less than a second to generate resulting in a speed up factor of 2.42E5 compared to CFD. Component-level simulations are conducted to determine the performance degradation resulting from the predicted airflow maldistribution profiles. The new ML model will enable rapid and accurate prediction of performance degradation resulting from airflow maldistribution in A-type HXs, allowing for more accurate and cost-effective HX design.

42 ENGINEERING↗

Waste heat recovery power electronics cooling

A cooling system for an electrified vehicle includes a first cooling loop for circulating coolant for cooling at least one of power electronics and a motor/generator of the vehicle. The first coolant loop includes a heat exchanger for exchanging heat with the coolant in the first cooling loop. A second cooling loop is provided for circulating coolant for cooling a battery of the vehicle. The second cooling loop includes a coolant chiller connected to a refrigeration system of the vehicle for exchanging heat in the coolant received from the battery with the refrigeration system of the vehicle.

Ernst, Timothy C.↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Helium process cycle

A unique process cycle and apparatus design separates the consumer (cryogenic) load return flow from most of the recycle return flow of a refrigerator and/or liquefier process cycle. The refrigerator and/or liquefier process recycle return flow is recompressed by a multi-stage compressor set and the consumer load return flow is recompressed by an independent consumer load compressor set that maintains a desirable constant suction pressure using a consumer load bypass control valve and the consumer load return pressure control valve that controls the consumer load compressor's suction pressure. The discharge pressure of this consumer load compressor is thereby allowed to float at the intermediate pressure in between the first and second stage recycle compressor sets. Utilizing the unique gas management valve regulation, the unique process cycle and apparatus design in which the consumer load return flow is separate from the recycle return flow, the pressure ratios of each recycle compressor stage and all main pressures associated with the recycle return flow are allowed to vary naturally, thus providing a naturally regulated and balanced floating pressure process cycle that maintains optimal efficiency at design and off-design process cycle capacity and conditions automatically.

42 ENGINEERING↗

Hydronic rooftop cooling systems

A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

42 ENGINEERING↗

Multiple simultaneous faults’ impacts on air-conditioner behavior and performance of a charge diagnostic method

Although there have been several studies that have focused on the effects of faults on the performance and on the characteristic features that could be used to detect faults, almost none of the research has studied the effects of multiple simultaneous faults. Existing fault detection and diagnosis approaches that have been developed based on single faults may struggle with simultaneous faults. Here, this paper is part of a series that present a methodology and comprehensive measurement data from a battery of laboratory tests on an air-conditioner with combinations of common faults (refrigerant charge, evaporator airflow, non-condensable gas, and liquid line restrictions) imposed, to show how the indicator variables and overall performance are impacted. The system has a microtube condenser and a fixed-orifice (FXO) expansion device, which are found to affect the features’ fault sensitivity. This experiment is the first to test these combined faults in an FXO-equipped system, so comparisons are made to a previously studied thermostatic expansion valve-equipped system. Finally, a promising charge diagnostic technology is assessed, to see how it is impacted by other faults. The faults reduced capacity by up to 42%, and efficiency by up to 39%. The charge diagnostic performed well, even with multiple faults present.

42 ENGINEERING↗

Choked flow mechanism of HFC-134a flowing through short-tube orifices

This paper is a continuation of the author's previous work. New experimental data on the occurrence of choked flow phenomenon and mass flow rate of HFC-134a inside short-tube orifices under choked flow condition are presented. Short-tube orifices diameters ranging from 0.406 mm to 0.686 mm with lengths ranging from 1 mm to 3 mm which can be applied to a miniature vapour-compression refrigeration system are examined. The experimental results indicated that the occurrence of choked flow phenomena inside short-tube orifices is different from that obtained from short-tube orifice diameters of greater than 1 mm, which are typically used in air-conditioner. The beginning of choked flow is dependent on the downstream pressure, degree of subcooling, and length-to-diameter ratio. Under choked flow condition, the mass flow rate is greatly varied with the short-tube orifice dimension, but it is slightly affected by the operating conditions. A correlation of mass flow rate through short-tube orifices is proposed in terms of the dimensionless parameters. The predicted results show good agreement with experimental data with a mean deviation of 4.69%. (author) transfer coefficient was also proposed. (author)

42 ENGINEERING↗

Using numerical methods to screen magnetocaloric materials in an active magnetic regenerative cycle

A 2-dimensional numerical model of a room temperature operating Active Magnetic Regenerator (AMR) that comprises of a regenerator, hot and cold heat exchangers, heat transfer fluid is developed. The regenerator is made of a magnetocaloric material (MCM) which heats up upon applying a magnetic field, H, and cools down when the field is removed; thus, making it the most essential part of an AMR. The model takes experimentally measured ΔT ad (H,T) and the C p (H,T) data as input and provides quantitative performance metrics of the magnetic cooling system, such as ΔT span and the cooling load, as output. With this model, it is possible to assess a wide range of MCMs in an AMR. 4 different MCMs were investigated using this model in terms of their ΔT span and the cooling loads—LaFe 10.96 Co 0.97 Si 1.07 , MnFeP (1-x) As (x) and AlFe 2 B 2 and Gd. During the screening of MCMs, all the important operating conditions of the device were fixed such as the fluid flow rate, ambient temperature, cycle duration, magnetic field strength. Our results indicate that Gd exhibits the maximum ΔT span with respectable cooling load, while AlFe 2 B 2 generates the lowest ΔT span . Even though LaFeCoSi compound did not perform as well as Gd, it could be the MCM choice for the realization of magnetic refrigeration on a global scale due to its much lower cost.

36 MATERIALS SCIENCE↗

EXERGY ANALYSIS OF THE CRYOGENIC HELIUM DISTRIBUTION SYSTEM FOR THE LARGE HADRON COLLIDER (LHC)

The Large Hadron Collider (LHC) at CERN features the world's largest helium cryogenic system, spreading over the 26.7 km circumference of the superconducting accelerator. With a total equivalent capacity of 145 kW at 4.5 K including 18 kW at 1.8 K, the LHC refrigerators produce an unprecedented exergetic load, which must be distributed efficiently to the magnets in the tunnel over the 3.3 km length of each of the eight independent sectors of the machine. We recall the main features of the LHC cryogenic helium distribution system at different temperature levels and present its exergy analysis, thus enabling to qualify second-principle efficiency and identify main remaining sources of irreversibility.

43 PARTICLE ACCELERATORS↗

High Temperature Superconducting Underground Cable

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating Modes and Cooling Capabilities of the 3-Stage ADR Developed for the Soft-X-Ray Spectrometer Instrument on Astro-H

A 3-stage adiabatic demagnetization refrigerator (ADR) is used on the Soft X-ray Spectrometer instrument on Astro-H to cool a 6x6 array of x-ray microcalorimeters to 50 mK. The ADR is supported by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and cool radiation shields within the cryostat. The ADR is configured so that it can use either the liquid helium or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated into the flight dewar in early 2014, and have since been extensively characterized and calibrated. This paper summarizes the operation and performance of the ADR in all of its operating modes

x-ray astronomy↗

3-Stage ADR for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite shortly after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). The spectrometer instrument, now named Resolve, will be similar to the original SXS design. It consists of a 6 by 6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage Adiabatic Demagnetization Refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5-degrees-Kelvin Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XRISM ADR and how it differs from the SXS version.

ADR (Adiabatic Demagnetization Refrigerator)↗

Planning for Failure: End-of-Life Strategies for HVAC Systems

In the United States, there are several existing and pending regulations for refrigerant management, and the range and complexity of these regulations make it difficult for engineers, contractors, and building owners to keep up with all the requirements, and they introduce confusion and uncertainty in the market. This article explores these issues to help describe a path forward for HVAC&R equipment waste.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acting Globally: Potential Carbon Emissions Mitigation Impacts from an International Standards and Labelling Program

This paper presents an analysis of the potential impacts of an international initiative designed to support and promote the development and implementation of appliances standards and labelling programs throughout the world. As part of previous research efforts, LBNL developed the Bottom Up Energy Analysis System (BUENAS), an analysis framework that estimates impact potentials of energy efficiency policies on a global scale. In this paper, we apply this framework to an initiative that would result in the successful implementation of programs focused on high priority regions and product types, thus evaluating the potential impacts of such an initiative in terms of electricity savings and carbon mitigation in 2030. In order to model the likely parameters of such a program, we limit impacts to a five year period starting in 2009, but assume that the first 5 years of a program will result in implementation of 'best practice' minimum efficiency performance standards by 2014. The 'high priority' regions considered are: Brazil, China, the European Union,India, Mexico and the United States. The products considered are: refrigerators, air conditioners, lighting (both fluorescent and incandescent), standby power (for consumer electronics) and televisions in the residential sector, and air conditioning and lighting in commercial buildings. In 2020, these regions and enduses account for about 37percent of global residential electricity and 29percent of electricity in commercial buildings. We find that 850Mt of CO2 could be saved in buildings by 2030 compared to the baseline forecast.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗