Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

Scanning transmission x-ray microscopy (STXM) combines x-ray microscopy and near edge x-ray absorption fine structure spectroscopy (NEXAFS). This combination provides spatially resolved bonding and oxidation state information. While there are reviews relevant to STXM/NEXAFS applications in other environmental fields (and magnetic materials) this chapter focuses on atmospheric aerosols. It provides an introduction to this technique in a manner approachable to non-experts. It begins with relevant background information on synchrotron radiation sources and a description of NEXAFS spectroscopy. The bulk of the chapter provides a survey of STXM/NEXAFS aerosol studies and is organized according to the type of aerosol investigated. The purpose is to illustrate the current range and recent growth of scientific investigations employing STXM-NEXAFS to probe atmospheric aerosol morphology, surface coatings, mixing states, and atmospheric processing.

47 OTHER INSTRUMENTATION↗

Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

Benner, W Henry↗

Method of making organic light emitting devices

The present invention provides a method for the preparation of organic light-emitting devices comprising a bilayer structure made by forming a first film layer comprising an electroactive material and an INP precursor material, and exposing the first film layer to a radiation source under an inert atmosphere to generate an interpenetrating network polymer composition comprising the electroactive material. At least one additional layer is disposed on the reacted first film layer to complete the bilayer structure. The bilayer structure is comprised within an organic light-emitting device comprising standard features such as electrodes and optionally one or more additional layers serving as a bipolar emission layer, a hole injection layer, an electron injection layer, an electron transport layer, a hole transport layer, exciton-hole transporting layer, exciton-electron transporting layer, a hole transporting emission layer, or an electron transporting emission layer.

47 OTHER INSTRUMENTATION↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol preparation of intact lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

60 APPLIED LIFE SCIENCES↗

A Robust and Flexible Design for GCEP Unattended Online Enrichment Monitoring: An OLEM Collection Node Network

Oak Ridge National Laoratory (ORNL) has engineered an on-line enrichment monitor (OLEM) to continuously measure U-235 emissions from the UF6 gas flowing through a unit header pipe of a gas centrifuge enrichment plant (GCEP) as a component of the International Atomic Energy Agency s (IAEA) new generation of technology to support enrichment plant safeguards1. In contrast to other enrichment monitoring approaches, OLEM calibrates and corrects for the pressure and temperature dependent UF6 gas-density without external radiation sources by using the inherent unit header pipe pressure dynamics and combining U-235 gamma-ray spectrometery using a shielded NaI detector with gas pressure and temperature data near the spectrum measurement point to obtain the enrichment of the gas as a function of time. From a safeguards perspective, OLEM can provide early detection of a GCEP being misused for production of highly enriched uranium, but would not detect directly the isolation and use of a cascade within the production unit to produce HEU. OLEM may also reduce the number of samples collected for destructive assay and, if coupled with load cell monitoring, could support isotope mass balance verification and unattended cylinder verification. The earlier paper presented OLEM as one component along with shared load cells and unattended cylinder verification, in the IAEA emering toolbox for unattended instruments at GCEPs1 and described the OLEM concept and how previous modeling studies and field measurements helped confirm the viability of a passive on-line enrichment monitor for meeting IAEA objectives and to support the development of performance targets. Phase I of the United States Support Program (USSP) OLEM project completed a preliminary hardware, software and communications design; phase II will build and test field prototypes in controlled laboratory settings and then at an operational facility. That paper also discussed many of the OLEM collection node commercial off the shelf (COTS) components and summarized the OLEM collection node data security provisions. This paper will discuss a secure and redundant network of OLEM collection nodes, auxiliary detection units and supporting junction boxes distributed throughout a facility for monitoring enrichment on product, feed and tails unit header pipes; the purpose and capability of the built-in Electronic Optical Sealing System (EOSS) network gateway; and a network approach for obtaining reliable and authenticated pressure measurements.

Younkin, James R↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with 3.2% resolution. RSL completed a crystal assessment, and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function, were calculated. Specifically, we report excellent linearity with the aliovalently calcium-doped CeBr3 crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred during doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal and assessed benchmark spectroscopy measurements. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallite. We obtain 4.5% for the packaged crystallite. More spectra are presented for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The current status and future direction of high magnetic field science in the United States

This grant provided partial support for the National Research Council (NRC) study that assesses the current status of high magnetic field research in the United States and provides recommendations to guide the future of research and technology development for this area given the needs of user communities and in the context of other programs worldwide. A pdf version of the report is available for download, for free, at http://www.nap.edu/catalog.php?record_id=18355. The science drivers fall into 4 broad areas—(1) condensed matter and materials physics; (2) chemistry, biochemistry, and biology; (3) medical and life science studies; and (4) other fields such as high-energy physics, plasma physics, and particle astrophysics. Among the topics covered in the report’s findings, conclusions, and recommendations are a recognition that there is a continuing need for a centralized facility but also that clear benefits will flow to research communities from decentralized facilities. According to the report, support agencies should evaluate whether to establish such facilities when 32 Tesla superconducting magnets become available. The report also recommends the provision of facilities that combine magnetic fields with scattering facilities and THz radiation sources, and sets out specific magnet goals for magnets needed in several areas of research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining the risk of cardiovascular disease using ion mobility of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

59 BASIC BIOLOGICAL SCIENCES↗

Supported liquid inorganic membranes for nuclear waste separation

A system and method for the extraction of americium from radioactive waste solutions. The method includes the transfer of highly oxidized americium from an acidic aqueous feed solution through an immobilized liquid membrane to an organic receiving solvent, for example tributyl phosphate. The immobilized liquid membrane includes porous support and separating layers loaded with tributyl phosphate. The extracted solution is subsequently stripped of americium and recycled at the immobilized liquid membrane as neat tributyl phosphate for the continuous extraction of americium. The sequestered americium can be used as a nuclear fuel, a nuclear fuel component or a radiation source, and the remaining constituent elements in the aqueous feed solution can be stored in glassified waste forms substantially free of americium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method of monitoring photoactive organic molecules in-situ during gas-phase deposition of the photoactive organic molecules

A method for in-situ monitoring of gas-phase photoactive organic molecules in real time while depositing a film of the photoactive organic molecules on a substrate in a processing chamber for depositing the film includes irradiating the gas-phase photoactive organic molecules in the processing chamber with a radiation from a radiation source in-situ while depositing the film of the one or more organic materials and measuring the intensity of the resulting photoluminescence emission from the organic material. One or more processing parameters associated with the deposition process can be determined from the photoluminescence intensity data in real time providing useful feedback on the deposition process.

14 SOLAR ENERGY↗

Synchrotron Radiation Workshop (SRW)

"Synchrotron Radiation Workshop" (SRW) is a physical optics computer code for calculation of detailed characteristics of Synchrotron Radiation (SR) generated by relativistic electrons in magnetic fields of arbitrary configuration and for simulation of the radiation wavefront propagation through optical systems of beamlines. Frequency-domain near-field methods are used for the SR calculation, and the Fourier-optics based approach is generally used for the wavefront propagation simulation. The code enables both fully- and partially-coherent radiation propagation simulations in steady-state and in frequency-/time-dependent regimes. With these features, the code has already proven its utility for a large number of applications in infrared, UV, soft and hard X-ray spectral range, in such important areas as analysis of spectral performances of new synchrotron radiation sources, optimization of user beamlines, development of new optical elements, source and beamline diagnostics, and even complete simulation of SR based experiments. Besides the SR applications, the code can be efficiently used for various simulations involving conventional lasers and other sources. SRW versions interfaced to Python and to IGOR Pro (WaveMetrics), as well as cross-platform library with C API, are available.

Chubar, O.↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

Transversely-illuminated high current photoconductive switches with geometry-constrained conductivity path

A photoconductive switch having a wide bandgap semiconductor material substrate between opposing electrodes, with one of the electrodes having an aperture or apertures at an electrode-substrate interface for transversely directing radiation therethrough from a radiation source into a triple junction region of the substrate, so as to geometrically constrain the conductivity path to within the triple junction region.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF SHORT UNDULATORS FOR ELECTRON-BEAM-RADIATION INTERACTION STUDIES

Interaction of an electron beam with external field or its own radiation has widespread applications ranging from coherent-radiation generation, phase space cooling or formation of temporally-structured beams. An efficient coupling mechanism between an electron beam and radiation field relies on the use of a magnetic undulator. In this contribution we detail our plans to build short (11-period) undulators with 7-cm period refurbishing parts of the aladdin U3 undulator [1]. Possible use of these undulators at available test facilities to support experiments relevant to cooling techniques and radiation sources are outlined.

43 PARTICLE ACCELERATORS↗

Digital Inject Book v. 1.7

Digital Inject Book is a software program designed to generate and managed simulated data for radiation detectors, used to increase the realism of training where real radiation sources are impractical, expensive, or simply not available.

Eldridge, Bryce↗

Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

43 PARTICLE ACCELERATORS↗

System and method for monitoring a wellbore

A detector assembly includes a scintillator configured to generate a light signal in response to an impinging radiation signal from an object, where the scintillator has a first end and a second end. Further, the detector assembly includes a first detector disposed adjacent the scintillator and configured to receive a first portion of the light signal from the scintillator and a second detector operatively coupled to the second end of the scintillator and configured to receive a second portion of the light signal from the scintillator. The detector assembly also includes a reflector operatively coupled to the scintillator and the first detector and configured to guide the light signal from the scintillator to the first detector, where the reflector is configured to redirect the first portion of the light signal by a determined amount to reduce a path length between a radiation source, the object, and the scintillator.

Kasten, Ansas Matthias↗