Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

The role of independent monitoring in maintaining community support through a radiological incident - a WIPP case study - 15107

The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy (DOE) waste repository for the permanent disposal of defense transuranic (TRU) wastes. The repository is mined in the Salado Formation, a bedded salt formation of the Permian era, approximately 655 m (2150 ft.) below land surface. Located near Carlsbad, New Mexico, the WIPP facility is the world's first deep geological disposal facility licensed to accept TRU waste. Environmental monitoring is a key component in the development and operation of any nuclear facility. Well after the WIPP facility had been sited and constructed, but before repository operations began, DOE and local community leaders recognized the value of having an independent environmental monitoring program in addition to the self-monitoring program required by regulation. An independent monitoring organization, the Carlsbad Environmental Monitoring and Research Center (CEMRC) was created by New Mexico State University at its Carlsbad campus. After almost fifteen years of successful waste disposal operations, the first airborne radiation was accidentally released from the WIPP and detected beyond the site boundary on February 14, 2014. The accident released moderate levels of radioactivity into the underground air. A small but measurable amount of radioactivity also escaped to the surface and was detected beyond the site's inner boundary. The results were reported to the public as they were obtained and verified. Releases were low and localized, and no radiation-related health effects among local workers or the public would be expected. CEMRC's independence and its extensive monitoring program played a crucial role in timely informing the local populations on the levels and types of radiation released from the WIPP. CEMRC also helped eliminate unnecessary concern surrounding fear of radiation by engaging local populations through news releases and presentations at 'town hall' meetings sponsored by the Mayor's Office and the Department of Energy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

{sup 18}-F-Fluorodeoxyglucose-Positron Emission Tomography Evaluation of Early Metabolic Response During Radiation Therapy for Cervical Cancer

Purpose: To document changes in cervical tumor {sup 18}-F-fluorodeoxyglocose (FDG) uptake during radiation therapy and to correlate those changes with post-treatment tumor response and survival outcome. Methods and Materials: A total of 36 patients with Stage Ib1 to IIIb cervical cancer were enrolled in an institutional protocol examining the use of fluorodeoxyglucose-positron emission tomography (FDG-PET) for brachytherapy treatment planning. As part of this study, FDG-PET or PET/computed tomograpy (CT) images were obtained before, during, and after the completion of radiation therapy. Tumor metabolic responses were assessed qualitatively and semi-quantitatively by measurement of the maximal standardized uptake value (SUV{sub max}). Results: Post-treatment FDG-PET images were obtained for 36 patients in this study. Of the patients, 29 patients had a complete metabolic response on the post-treatment PET, 4 had a partial metabolic response, and 3 had new sites of FDG uptake. Six patients had a complete metabolic response observed during radiation therapy, 26 had a partial metabolic response and 4 had stable or increased tumor metabolic activity. For patients with complete metabolic response during radiation therapy, median time to complete response was 29.5 days (range, 18-43 days). The mean cervical tumor SUV{sub max} decreased from 11.2 (SD, 6.3; range, 2.1-38.0) pretreatment to 2.4 (SD, 2.7; range, 0-8.8) mid treatment, and 0.5 (SD, 1.7; range, 0-8.3) post-treatment. Conclusions: During radiation therapy for cervical cancer, FDG-PET can be used to monitor treatment response. Complete metabolic response during radiation therapy was observed for a subset of patients. Recommendations regarding the optimal timing of FDG-PET during treatment for cervical cancer will require further systematic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence Report: Risk of Acute Radiation Syndromes Due to Solar Particle Events

Crew health and performance may be impacted by a major solar particle event (SPE), multiple SPEs, or the cumulative effect of galactic cosmic rays (GCR) and SPEs. Beyond low-Earth orbit, the protection of the Earth's magnetosphere is no longer available, such that increased shielding and protective mechanisms are necessary in order to prevent acute radiation sickness and impacts to mission success or crew survival. While operational monitoring and shielding are expected to minimize radiation exposures, there are EVA scenarios outside of low-Earth orbit where the risk of prodromal effects, including nausea, vomiting, anorexia, and fatigue, as well as skin injury and depletion of the blood-forming organs (BFO), may occur. There is a reasonable concern that a compromised immune system due to high skin doses from a SPE or due to synergistic space flight factors (e.g., microgravity) may lead to increased risk to the BFO. The primary data available at present are derived from analyses of medical patients and persons accidentally exposed to acute, high doses of low-linear energy transfer (LET) (or terrestrial) radiation. Data more specific to the space flight environment must be compiled to quantify the magnitude of increase of this risk and to develop appropriate protection strategies. In particular, information addressing the distinct differences between solar proton exposures and terrestrial exposure scenarios, including radiation quality, dose-rate effects, and non-uniform dose distributions, is required for accurate risk estimation.

Carnell, Lisa↗

Studies of VLF radio waves for sudden ionospheric disturbances (SID) in Kashmir region

It is recognized that the ionosphere may be sensitive to seismic effects, and the detection of ionospheric perturbations associated with seismicity would be useful for short term prediction of seismic events. To observe this effect, Indian Centre for Space Physics has installed an antenna and receiver system at Kashmir University to monitor the variation of the VLF signal transmitted from VTX. We present the preliminary results from this station.

58 GEOSCIENCES↗

Enhanced room temperature oxidation in silicon and porous silicon under 10 keV x-ray irradiation

We report the observation of enhanced oxidation on silicon and porous silicon samples exposed in air ambient to high-dose-rate 10 keV x-ray radiation at room temperature. The evolution of the radiation-induced oxide growth is monitored by ellipsometry and interferometric reflectance spectroscopy. Fourier transform infrared (FTIR) spectroscopy shows the emergence of Si-O-Si stretching modes and corresponding suppression of SiH{sub x} and Si-Si modes in the porous silicon samples. The radiation response depends strongly on initial native oxide thickness and Si-H surface species. The enhanced oxidation mechanism is attributed to photoinduced oxidation processes wherein energetic photons are used to dissociate molecular oxygen and promote the formation of more reactive oxygen species.

36 MATERIALS SCIENCE↗

Radiation tolerance of piezoelectric bulk single-crystal aluminum nitride

For practical use in harsh radiation environments, we pose selection criteria for piezoelectric materials for nondestructive evaluation (NDE) and material characterization. Using these criteria, piezoelectric aluminum nitride is shown to be an excellent candidate. The results of tests on an aluminumnitride-based transducer operating in a nuclear reactor are also presented. We demonstrate the tolerance of single-crystal piezoelectric aluminum nitride after fast and thermal neutron fluences of 1.85 × 1018 neutron/cm2 and 5.8 × 1018 neutron/cm2, respectively, and a gamma dose of 26.8 MGy. The radiation hardness of AlN is most evident from the unaltered piezoelectric coefficient d33, which measured 5.5 pC/N after a fast and thermal neutron exposure in a nuclear reactor core for over 120 MWh, in agreement with the published literature value. The results offer potential for improving reactor safety and furthering the understanding of radiation effects on materials by enabling structural health monitoring and NDE in spite of the high levels of radiation and high temperatures, which are known to destroy typical commercial ultrasonic transducers.

99 GENERAL AND MISCELLANEOUS↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2015

This report provides a synopsis of ongoing environmental management performance and compliance activities conducted during 2015, meeting the requirements DOE Order 231.1B, Admin Chg 1, Environmental, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment. The report addresses the operations occurring on the PNNL Campus in Richland, Washington, and at the PNNL Marine Sciences Laboratory (MSL) in Sequim, Washington. It describes the location and background for each facility; addresses compliance with all applicable DOE, federal, state, and local regulations and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification.

54 ENVIRONMENTAL SCIENCES↗

Enhanced multifunctional paint for detection of radiation

An enhanced multifunctional paint apparatus, systems, and methods for detecting radiation on a surface include providing scintillation particles; providing an enhance neutron absorptive material; providing a binder; combining the scintillation particles, the enhance neutron absorptive material, and the binder creating a multifunctional paint; applying the multifunctional paint to the surface; and monitoring the surface for detecting radiation.

36 MATERIALS SCIENCE↗

Contrastive Machine Learning with Gamma Spectroscopy Data Augmentations for Detecting Shielded Radiological Material Transfers

Data analysis techniques can be powerful tools for rapidly analyzing data and extracting information that can be used in a latent space for categorizing observations between classes of data. Machine learning models that exploit learned data relationships can address a variety of nuclear nonproliferation challenges like the detection and tracking of shielded radiological material transfers. The high resource cost of manually labeling radiation spectra is a hindrance to the rapid analysis of data collected from persistent monitoring and to the adoption of supervised machine learning methods that require large volumes of curated training data. Instead, contrastive self-supervised learning on unlabeled spectra can enhance models that are built on limited labeled radiation datasets. This work demonstrates that contrastive machine learning is an effective technique for leveraging unlabeled data in detecting and characterizing nuclear material transfers demonstrated on radiation measurements collected at an Oak Ridge National Laboratory testbed, where sodium iodide detectors measure gamma radiation emitted by material transfers between the High Flux Isotope Reactor and the Radiochemical Engineering Development Center. Label-invariant data augmentations tailored for gamma radiation detection physics are used on unlabeled spectra to contrastively train an encoder, learning a complex, embedded state space with self-supervision. A linear classifier is then trained on a limited set of labeled data to distinguish transfer spectra between byproducts and tracked nuclear material using representations from the contrastively trained encoder. The optimized hyperparameter model achieves a balanced accuracy score of 80.30%. Any given model—that is, a trained encoder and classifier—shows preferential treatment for specific subclasses of transfer types. Regardless of the classifier complexity, a supervised classifier using contrastively trained representations achieves higher accuracy than using spectra when trained and tested on limited labeled data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Power Multi-Aspect Space Radiation Detector System

The advanced space radiation detector development team at NASA Glenn Research Center (GRC) has the goal of developing unique, more compact radiation detectors that provide improved real-time data on space radiation. The team has performed studies of different detector designs using a variety of combinations of solid-state detectors, which allow higher sensitivity to radiation in a smaller package and operate at lower voltage than traditional detectors. Integration of all of these detector technologies will result in an improved detector system in comparison to existing state-of-the-art (SOA) instruments for the detection and monitoring of the deep space radiation field.

Wrbanek, John D.↗

Development of Single Crystal Chemical Vapor Deposition Diamonds for Detector Applications

Diamond was studied as a possible radiation hard technology for use in future high radiation environments. With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2013, all LHC experiments are planning for detector upgrades which require radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has now been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is installed in all LHC experiments. As a result, this material is now being discussed as an alternative sensor material for tracking very close to the interaction region of the super-LHC where the most extreme radiation conditions will exist. Our work addressed the further development of the new material, single-crystal Chemical Vapor Deposition diamond, towards reliable industrial production of large pieces and new geometries needed for detector applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2010 Annual Health Physics Report for the HEU Transparency Program

During the 2010 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2010, there were 141 person-trips that required dose monitoring of the U.S. monitors. Of the 141 person-trips, 129 person-trips were Special Monitoring Visits (SMVs) and 12 person-trips were Transparency Monitoring Office (TMO) trips. In 8 of these TMO trips the TMO monitors participated also in the UEIE SMVs and in 2 TMO trips the TMO monitors participated in UEIE and MPA SMVs. There were three monitoring visits (source changes) that were back-to-back SMVs with a total of 25 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigating ocean surface solar irradiance using Nimbus-7 Earth Radiation Budget data

A new estimation technique is introduced, using a surface solar irradiance database with advanced climate monitoring capabilities. Incorporating the Nimbus-7 Earth Radiation Budget (ERB) planetary albedo data obtained from wide-field-of-view radiometer measurements, the new solar irradiance model uses plane-parallel theory and assumes the isotropy of radiance reflected by the clouds and ocean surface. A brief description of the data, a treatment of the model verification, and a discussion of surface solar irradiance variability are presented. The results demonstrate the model's sensitivity to large-scale seasonal and interannual phenomena. A summary of the investigation is also presented, along with a perspective on potential uses and future development.

Chertock, Beth↗

Resolution Limits of Near IR and IR Thermography Applied to Imaging Thermal Heterogeneities in Nuclear Fuel Surrogate Materials

ABSTRACT The main goal of the project is: To develop an IR thermographic method to monitor fuel pellet cracking inside the hostile environment of the nuclear core. This method will use a high temperature and radiation resistant fiber optic bundle to monitor the fuel pellet inside the core and transmit the information outside to an IR camera. This method will give a visual cue (using IR video) as to when the crack started to form and how it progresses. To achieve this goal, we identified the following as major milestones of the project: 1. Perform 1D modeling of temperature and blackbody radiation intensity across a crack. 2. Image a crack on a fuel cell surrogate using an IR camera with free-space optics and high power laser setup. 3. Simulate cracking in the surrogate sample through inductive heating method, and demonstrate imaging crack formation using the free-space optics setup. 4. Determine parameters for a suitable fiber optic bundle compatible with the IR camera based on the results from the free-space optics experiments. 5. Demonstrate imaging using fiber bundle and integrate viewing system with nuclear core at INL. This report focuses on Goals 1-3. We have successfully achieved Goals 1-3 and are making steady progress towards achieving Goals 4-9. Goals 2 and 4 are very similar and require 2 basic parts: the imaging system and the method to crack the fuel surrogate to replicate the fuel pellet cracking in the nuclear reactor core. The following sections describe the 1D modeling of temperature and blackbody radiation intensity across a crack (Goal 1), procedure to create crack on fuel surrogates and results (Goals 2 and 3), and the IR imaging system and results (Goal 2).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

SU-E-J-31: Monitor Interfractional Variation of Tumor Respiratory Motion Using 4D KV Conebeam Computed Tomography for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: 4DCT has been widely used to generate internal tumor volume (ITV) for a lung tumor for treatment planning. However, lung tumors may show different respiratory motion on the treatment day. The purpose of this study is to evaluate 4D KV conebeam computed tomography (CBCT) for monitoring tumor interfractional motion variation between simulation and each fraction of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: 4D KV CBCT was acquired with the Elekta XVI system. The accuracy of 4D KV CBCT for image-guided radiation therapy (IGRT) was tested with a dynamic thorax motion phantom (CIRS, Virginia) with a linear amplitude of 2 cm. In addition, an adult anthropomorphic phantom (Alderson, Rando) with optically stimulated luminescence (OSL) dosimeters embedded at the center and periphery of a slab of solid water was used to measure the dose of 4D KV CBCT and to compare it with the dose with 3D KV CBCT. The image registration was performed by aligning\ each phase images of 4D KV CBCT to the planning images and the final couch shifts were calculated as a mean of all these individual shifts along each direction.A workflow was established based on these quality assurance tests for lung cancer patients. Results: 4D KV CBCT does not increase imaging dose in comparison to 3D KV CBCT. Acquisition of 4D KV CBCT is 4 minutes as compared to 2 minutes for 3D KV CBCT. Most of patients showed a small daily variation of tumor respiratory motion about 2 mm. However, some patients may have more than 5 mm variations of tumor respiratory motion. Conclusion: The radiation dose does not increase with 4D KV CBCT. 4D KV CBCT is a useful tool for monitoring interfractional variations of tumor respiratory motion before SBRT of lung cancer patients.

60 APPLIED LIFE SCIENCES↗

The Use of Unmanned Aerial Vehicles for Rapid and Repeatable 3D Radiological Site Characterization - 18352

As unmanned aerial vehicles (UAVs) are beginning to become heavily featured within a number of industries globally, the technology remains underutilized within the nuclear industry, particularly in routine monitoring investigations. Using a temporary Japanese waste storage facility (used to house topsoil contaminated with fallout from the Fukushima nuclear incident) as an analogy for a typical low-level waste repository (LLWR) site, the suitability of UAV-hosted radiation mapping systems for routine site investigations is evaluated. The criteria used to assess the performance of the custom UAV and commercial radiation mapping system focusses on the repeatability of both the flight and the produced radiation maps from two identical surveys at the chosen site. Additionally, the speed of deployment is assessed against the time taken to complete a walking survey of the site. The results indicate that the radiation maps derived from the two repeat surveys are directly comparable both visually and statistically, despite minor differences in the flight of the UAV between both surveys. Furthermore, the terrain independent nature of the airborne radiation mapping system meant that the time taken to complete the survey was reduced when compared with the similar resolution ground-based survey. The use of UAV-hosted radiation mapping systems therefore presents a powerful tool with which to rapidly complete routine radiological monitoring procedures within active nuclear environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the Fundamental Radiation Chemistry of the Organic Diluent, and the Effect of Metal Ion Complexation on the Radiochemical Behavior of Active Compounds

All used nuclear fuel (UNF) reprocessing technologies must operate efficiently in the presence of an intense, multi-component (predominantly alpha, beta, and gamma) radiation field. Consequently, radiation-induced degradation of reprocessing systems is of concern, as it negatively impacts process performance over time due to the destruction of both active compounds (ligands, phase modifiers, holdback agents, etc.) and the formation of degradation products. Reprocessing solvent system radiolysis has been linked to changes in separation efficiency and physical properties of solvent mixtures, solvent-recycle longevity, crud formation, and other unexpected outcomes that impact the efficient recovery of valuable materials (e.g., the actinides) and the volume of hazardous radioactive waste for final disposal, i.e., in a geological repository. Consequently, a fundamental understanding of radiolytic processes and their effects on reprocessing solvent system performance is critical for: (i) the cost-effective development and innovation of separation technologies; (ii) the design and implementation of predictive radiation chemical models for process monitoring and lifetimes; and (iii) potentially the ability to exploit radiolytic phenomenon to our benefit, e.g., strategic radiolysis of active molecules to liberate specific degradation products that aid subsequent process stages. Despite extensive investigation into the radiolytic behavior of active solvent system compounds, little attention has been given to understanding (i) the radiation chemical behavior and modification of the organic diluent and (ii) the effect of metal ion complexation on the radiochemical behavior of active compounds.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗