Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a commercial biologically based IMRT treatment planning system

A new inverse treatment planning system (TPS) for external beam radiation therapy with high energy photons is commercially available that utilizes both dose-volume-based cost functions and a selection of cost functions which are based on biological models. The purpose of this work is to evaluate quality of intensity-modulated radiation therapy (IMRT) plans resulting from the use of biological cost functions in comparison to plans designed using a traditional TPS employing dose-volume-based optimization. Treatment planning was performed independently at two institutions. For six cancer patients, including head and neck (one case from each institution), prostate, brain, liver, and rectal cases, segmental multileaf collimator IMRT plans were designed using biological cost functions and compared with clinically used dose-based plans for the same patients. Dose-volume histograms and dosimetric indices, such as minimum, maximum, and mean dose, were extracted and compared between the two types of treatment plans. Comparisons of the generalized equivalent uniform dose (EUD), a previously proposed plan quality index (fEUD), target conformity and heterogeneity indices, and the number of segments and monitor units were also performed. The most prominent feature of the biologically based plans was better sparing of organs at risk (OARs). When all plans from both institutions were combined, the biologically based plans resulted in smaller EUD values for 26 out of 33 OARs by an average of 5.6 Gy (range 0.24 to 15 Gy). Owing to more efficient beam segmentation and leaf sequencing tools implemented in the biologically based TPS compared to the dose-based TPS, an estimated treatment delivery time was shorter in most (five out of six) cases with some plans showing up to 50% reduction. The biologically based plans were generally characterized by a smaller conformity index, but greater heterogeneity index compared to the dose-based plans. Overall, compared to plans based on dose-volume optimization, plans with equivalent target coverage obtained using the biologically based TPS demonstrate improved dose distributions for the majority of normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Assessment of Patterns of Failure After High-Precision Definitive (Chemo)Radiation in Head-and-Neck Squamous Cell Carcinoma

Purpose: To prospectively analyze patterns of failure in patients with head-and-neck squamous cell carcinoma treated with definitive high-precision radiotherapy with a focus on location of failure relative to target volume coverage. Methods and Materials: Sixty patients treated with three-dimensional conformal radiotherapy or intensity-modulated radiation therapy were included. Locoregional failure volume was defined on the planning data set at relapse, and dose received was analyzed by use of dose-volume histograms. Results: Thirteen patients were deemed to have had locoregional failures, of which two did not have any viable tumor on salvage neck dissection, leaving eleven patients with proven persistent or recurrent locoregional disease. Of these, 9 patients had in-field failure, 1 marginal failure, and 1 both in-field and marginal failures. Overall, only 2 of 11 patients (18%) with relapse had any marginal failure. Of the 20 sites of locoregional failure, 15 (75%) were in-field and 5 (25%) marginal. Distant metastases were detected in 3 patients, whereas a second new primary developed in 3 others. With a median follow-up of 26 months (interquartile range, 18-31 months) for surviving patients, the 3-year local control, locoregional control, disease-free survival, and overall survival rates were 75.3%, 74%, 67.2%, and 60.5%, respectively. Conclusions: Locoregional relapse remains the predominant pattern of failure in head-and-neck squamous cell carcinoma treated with high-precision definitive radiotherapy with the majority of failures occurring 'in-field' within the high-dose volume. Marginal failures can occur, particularly in the vicinity of the spared parotid gland. The therapeutic index of high-precision conformal radiotherapy is largely dependent on adequate selection and delineation of target volumes and organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Coplanar Partial Left Breast Irradiation Using Tomotherapy-Based Topotherapy

Purpose: To investigate the use of topotherapy for accelerated partial breast irradiation through field-design optimization and dosimetric comparison to linear accelerator-based three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT). Methods and Materials: Hypothetical 3-cm lumpectomy sites were contoured in each quadrant of a left breast by using dosimetric guidelines from the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol. Coplanar intensity-modulated topotherapy treatment plans were optimized by using two-, three-, four-, five-, and seven-field arrangements for delivery by the tomotherapy unit with fixed gantry angles. Optimized noncoplanar five-field 3D-CRT and IMRT were compared with corresponding topotherapy plans. Results: On average, 99.5% {+-} 0.5% of the target received 100% of the prescribed dose for all topotherapy plans. Average equivalent uniform doses ranged from 1.20-2.06, 0.79-1.76, and 0.10-0.29 Gy for heart, ipsilateral lung, and contralateral lung, respectively. Average volume of normal breast exceeding 90% of the prescription and average area of skin exceeding 35 Gy were lowest for five-field plans. Average uniformity indexes for five-field plans using 3D-CRT, IMRT, and topotherapy were 1.047, 1.050, and 1.040, respectively. Dose-volume histograms and calculated equivalent uniform doses of all three techniques illustrate clinically equivalent doses to ipsilateral breast, lung, and heart. Conclusions: This dosimetric evaluation for a single patient shows that coplanar partial breast topotherapy provides good target coverage with exceptionally low dose to organs at risk. Use of more than five fields provided no additional dosimetric advantage. A comparison of five-field topotherapy to 3D-CRT and IMRT for accelerated partial breast irradiation illustrates equivalent target conformality and uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Implications of an Injection of Hyaluronic Acid for Preserving the Rectal Wall in Prostate Stereotactic Body Radiation Therapy

Purpose: This study assessed the contribution of ahyaluronic acid (HA) injection between the rectum and the prostate to reducing the dose to the rectal wall in stereotactic body radiation therapy (SBRT). Methods and Materials: As part of a phase 2 study of hypofractionated radiation therapy (62 Gy in 20 fractions), the patients received a transperineal injection of 10 cc HA between the rectum and the prostate. A dosimetric computed tomographic (CT) scan was systematically performed before (CT1) and after (CT2) the injection. Two 9-beam intensity modulated radiation therapy-SBRT plans were optimized for the first 10 patients on both CTs according to 2 dosage levels: 5 × 6.5 Gy (PlanA) and 5 × 8.5 Gy (PlanB). Rectal wall parameters were compared with a dose–volume histogram, and the prostate–rectum separation was measured at 7 levels of the prostate on the center line of the organ. Results: For both plans, the average volume of the rectal wall receiving the 90% isodose line (V90%) was reduced up to 90% after injection. There was no significant difference (P=.32) between doses received by the rectal wall on CT1 and CT2 at the base of the prostate. This variation became significant from the median plane to the apex of the prostate (P=.002). No significant differences were found between PlanA without HA and PlanB with HA for each level of the prostate (P=.77, at the isocenter of the prostate). Conclusions: HA injection significantly reduced the dose to the rectal wall and allowed a dose escalation from 6.5 Gy to 8.5 Gy without increasing the dose to the rectum. A phase 2 study is under way in our department to assess the rate of acute and late rectal toxicities when SBRT (5 × 8.5 Gy) is combined with an injection of HA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radical Radiation Therapy After Lung-Sparing Surgery for Malignant Pleural Mesothelioma: Survival, Pattern of Failure, and Prognostic Factors

Purpose: To prospectively assess the survival, patterns of failure, and prognostic factors in a large cohort of patients with malignant pleural mesothelioma who had undergone a novel trimodal therapeutic approach, including lung-sparing surgery, chemotherapy, and subsequent treatment with high doses of intensity modulated radiation therapy (IMRT) to the whole hemithorax. Methods and Materials: The analysis was conducted on the data from 69 patients. Of the 69 patients, 35 underwent extended pleurectomy/decortication (P/D), with resection of the entire pleura, along with portions of the pericardium and diaphragm and 34, partial pleurectomy, defined as partial removal of parietal or visceral pleura for diagnostic purposes, leaving gross tumor behind in all cases. All patients received cisplatin/pemetrexed chemotherapy. Postoperative IMRT was delivered to the entire hemithorax, excluding the intact lung. The IMRT dose was 50 Gy in 25 fractions. Any fluorodeoxyglucose-avid areas or regions of particular concern for residual disease were given a simultaneous boost to 60 Gy. Results: The median follow-up duration was 19 months. No difference was seen in overall survival and locoregional control between the extended P/D group and the partial pleurectomy group. The 2-year overall survival was 65% and 58% in the extended P/D and partial pleurectomy groups, respectively (P=.94). Locoregional control at 2 years was 65% and 64% in the extended P/D and partial pleurectomy groups, respectively (P=.75). The predominant pattern of failure was distant: 19 patients (27.5%) developed distant metastases as the first site of relapse. Gross residual disease after surgery was significantly associated with overall survival (hazard ratio 3.45). One fatal pneumonitis was reported; 14 cases (20%) of grade 2 to 3 pneumonitis were documented. Conclusions: Radical IMRT after lung-sparing surgery and chemotherapy for malignant pleural mesothelioma leads to promising survival results and acceptable toxicity rates. The similarity of survival between patients treated with extended P/D or partial pleurectomy observed in our study is intriguing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategies for Motion Robust Proton Therapy With Pencil Beam Scanning for Esophageal Cancer

Proton therapy of esophageal cancer is superior to photon radiation therapy in terms of normal tissue sparing. However, respiratory motion and anatomical changes may compromise target dose coverage owing to density changes, geometric misses, and interplay effects. Here we investigate the combined effect on clinical target volume (CTV) coverage and compare proton therapy with intensity modulated radiation therapy (IMRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

White dwarfs as infrared sources in the galactic centre.

It is shown that quantized magnetic bremsstrahlung radiation in intense magnetic fields from the surface layers of white dwarfs could serve as one of the possible explanations for the infrared emission from the center of the galaxy that has been detected by Hoffmann et al. (1971). It is assumed, in particular, that the infrared radiation is from clusters of white dwarfs.

Chow, T. L.↗

Radiation-Induced Plutonium Redox Chemistry

Plutonium plays a key role in global actinide research and nuclear fuel cycle technologies, and yet, our fundamental understanding of its inherent radiation-induced chemical behavior is limited. These radiation-induced processes cannot simply be switched off, as they are as fundamentally inherent to plutonium as the impact of relativistic effects on its f-electrons. In less chemically complex actinide systems, such as aqueous solutions of neptunium and americium, , radiolysis products play a significant role in the redox cycling of their oxidation states. However, plutonium's multiple, coexisting, and chemically active oxidation states, which comprise of bare ions and dioxo cations, provide additional redox pathways that complicate radiation-induced processes. Oxidation state control is critical for the manipulation of plutonium, especially in used nuclear fuel reprocessing technologies, where oxidation specific states are successfully extracted, and others rejected. Consequently, mechanistically understanding the behavior of plutonium’s multiple oxidation states in the presence of intense ionizing radiation fields is essential for predicting the behavior of this element under multiple conditions that support the development and innovation of nuclear fuel cycle technologies. Here, we present recent advances in our understanding of plutonium radiation chemistry, including the first-ever multiscale model for predicting gamma radiation-induced plutonium redox chemistry, and new chemical kinetics for the reaction of plutonium and its complexes of tributyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA) with transients radiolysis products, a measured using electron pulse radiolysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

May 4, 1998 Storm: Observations of Energetic Ion Composition by POLAR

A major geomagnetic storm occurred at 5:00-12:05 UT on May 4, 1998. During this period, the magnetosphere was compressed and eroded; POLAR traveled in its outbound orbit from the equatorial radiation belt to the cusp and crossed the magnetopause into the magnetosheath. Two CEP-like (Cusp Energetic Particle) events with two to three orders of magnitudes enhancements of MeV ion fluxes were measured. The first event had a peak flux higher than that of the intense outer radiation belt in the equatorial plane. The shape of the measured energy spectra (in the unit of keV/e) were ion species dependent. For He+/He++ ratio at 18-269 keV/e, the difference between the radiation belt and the magnetosheath can be by a factor of as large as 62. In the magnetosheath, the 18-269 keV/e ion composition are variable, indicating a mass dependent acceleration process. These MeV ions may be energized by a mechanism in the cusp responsible for the CEP events previously reported.

Chen, Jiasheng↗

Experiments and Computational Theory for Electrical Breakdown in Critical Components: THz Imaging of Electronic Plasmas.

This report describes the development of ultra-short pulse laser (USPL) induced terahertz (THz) radiation to image electronic plasmas during electrical breakdown. The technique uses three pulses from two USPLs to (1) trigger the breakdown, (2) create a 2 picosecond (ps, 10 -12 s), THz pulse to illuminate the breakdown, and (3) record the THz image of the breakdown. During this three year internal research program, sub-picosecond jitter timing for the lasers, THz generation, high bandwidth (BW) diagnostics, and THz image acquisition was demonstrated. High intensity THz radiation was optically-induced in a pulse-charged gallium arsenide photoconductive switch. The radiation was collected, transported, concentrated, and co-propagated through an electro-optic crystal with an 800 nm USPL pulse whose polarization was rotated due to the spatially varying electric field of the THz image. The polarization modulated USPL pulse was then passed through a polarizer and the resulting spatially varying intensity was detected in a high resolution digital camera. Single shot images had a signal to noise of %7E3:1. Signal to noise was improved to %7E30:1 with several experimental techniques and by averaging the THz images from %7E4000 laser pulses internally and externally with the camera and the acquisition system (40 pulses per readout). THz shadows of metallic films and objects were also recorded with this system to demonstrate free-carrier absorption of the THz radiation and improve image contrast and resolution. These 2 ps THz pulses were created and resolved with 100 femtosecond (fs, 10 -15 s) long USPL pulses. Thus this technology has the capability to time-resolve extremely fast repetitive or single shot phenomena, such as those that occur during the initiation of electrical breakdown. The goal of imaging electrical breakdown was not reached during this three year project. However, plans to achieve this goal as part of a follow-on project are described in this document. Further modifications to improve the THz image contrast and resolution are proposed, and after they are made, images of photo-induced carriers in gallium arsenide and silicon will be acquired to evaluate image sensitivity versus carrier density. Finally electrical breakdown will be induced with the first USPL pulse, illuminated with THz radiation produced with the second USPL pulse and recorded with the third USPL pulse.

36 MATERIALS SCIENCE↗

Characterization of out-of-band radiation and plasma parameters in laser-produced Sn plasmas for extreme ultraviolet lithography light sources

Out-of-band (OOB) radiation, in contrast to the in-band radiation at 13.5 nm in a 2% bandwidth, emitted from dense tin plasmas generated by a laser was investigated for application as an extreme ultraviolet lithography light source. It was found that the continuum spectrum, which overwhelms the atomic and ionic line emissions, is responsible for the intense OOB radiation. The spectral distribution of the continuum emission matches that of blackbody radiation with a temperature of about 10 eV. The OOB radiation can be considerably suppressed by employing a minimum-mass target and short-pulse laser irradiation. Spectroscopic observations were made to examine the spatiotemporal behavior of the plasma immediately after laser irradiation. Prominent line broadening due to the Stark effect in the high-density plasma was observed, from which the variation of the electron density was deduced. The electron density and temperature on the target surface were 10{sup 17}-10{sup 18} cm{sup -3} and a few eV's, respectively, in the first 200 ns after laser illumination. In addition, the expansion velocities of neutral and singly ionized tin atoms were deduced from time-of-flight transients in the spectral emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Late degeneration in rabbit tissues after irradiation by heavy ions

Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

Lett, J. T.↗

Plume Particle Collection and Sizing from Static Firing of Solid Rocket Motors

Thermal radiation from the plume of any solid rocket motor, containing aluminum as one of the propellant ingredients, is mainly from the microscopic, hot aluminum oxide particles in the plume. The plume radiation to the base components of the flight vehicle is primarily determined by the plume flowfield properties, the size distribution of the plume particles, and their optical properties. The optimum design of a vehicle base thermal protection system is dependent on the ability to accurately predict this intense thermal radiation using validated theoretical models. This article describes a successful effort to collect reasonably clean plume particle samples from the static firing of the flight simulation motor (FSM-4) on March 10, 1994 at the T-24 test bed at the Thiokol space operations facility as well as three 18.3% scaled MNASA motors tested at NASA/MSFC. Prior attempts to collect plume particles from the full-scale motor firings have been unsuccessful due to the extremely hostile thermal and acoustic environment in the vicinity of the motor nozzle.

Sambamurthi, Jay K.↗