Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Mode analysis of photonic crystal L3 cavities in self-suspended lithium niobate membranes

We report on a multimodal analysis of photonic crystal L3 cavities milled in lithium niobate free-standing membranes. The classical L3 cavity geometry is compared to an L3 cavity containing a second lattice superimposed on the primary one. Those two different geometries are investigated in terms of vertical radiation and quality (Q) factor for each mode of the cavities. Depending on the cavity geometry, some modes undergo an enhancement of their vertical radiation into small angles while other modes experience a higher Q factor. Experimental characterizations are corroborated by three-dimensional finite difference time domain simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Air damping of atomically thin MoS{sub 2} nanomechanical resonators

We report on experimental measurement of air damping effects in high frequency nanomembrane resonators made of atomically thin molybdenum disulfide (MoS{sub 2}) drumhead structures. Circular MoS{sub 2} nanomembranes with thickness of monolayer, few-layer, and multi-layer up to ∼70 nm (∼100 layers) exhibit intriguing pressure dependence of resonance characteristics. In completely covered drumheads, where there is no immediate equilibrium between the drum cavity and environment, resonance frequencies and quality (Q) factors strongly depend on environmental pressure due to bulging of the nanomembranes. In incompletely covered drumheads, strong frequency shifts due to compressing-cavity stiffening occur above ∼200 Torr. The pressure-dependent Q factors are limited by free molecule flow (FMF) damping, and all the mono-, bi-, and tri-layer devices exhibit lower FMF damping than thicker, conventional devices do.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Time-domain response of atomically thin MoS{sub 2} nanomechanical resonators

We measure the energy relaxation rate of single- and few-layer molybdenum disulphide (MoS{sub 2}) nanomechanical resonators by detecting the resonator ring-down. Recent experiments on these devices show a remarkably low quality (Q)-factor when taking spectrum measurements at room temperature. The origin of the low spectral Q-factor is an open question, and it has been proposed that besides dissipative processes, frequency fluctuations contribute significantly to the resonance line-width. The spectral measurements performed thus far however, do not allow one to distinguish these two processes. Here, we use time-domain measurements to quantify the dissipation. We compare the Q-factor obtained from the ring-down measurements to those obtained from the thermal noise spectrum and from the frequency response of the driven device. In few-layer and single-layer MoS{sub 2} resonators, the two are in close agreement, which demonstrates that the spectral line-width in MoS{sub 2} membranes at room temperature is limited by dissipation, and that excess spectral broadening plays a negligible role.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cascaded Brillouin lasing in monolithic barium fluoride whispering gallery mode resonators

We report the observation of stimulated Brillouin scattering and lasing at 1550 nm in barium fluoride (BaF{sub 2}) crystal. Brillouin lasing was achieved with ultra-high quality (Q) factor monolithic whispering gallery mode mm-size disk resonators. Overmoded resonators were specifically used to provide cavity resonances for both the pump and all Brillouin Stokes waves. Single and multiple Brillouin Stokes radiations with frequency shift ranging from 8.2 GHz up to 49 GHz have been generated through cascaded Brillouin lasing. BaF{sub 2} resonator-based Brillouin lasing can find potential applications for high-coherence lasers and microwave photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-nanoparticle detection with slot-mode photonic crystal cavities

Optical cavities that are capable for detecting single nanoparticles could lead to great progress in early stage disease diagnostics and the study of biological interactions on the single-molecule level. In particular, photonic crystal (PhC) cavities are excellent platforms for label-free single-nanoparticle detection, owing to their high quality (Q) factors and wavelength-scale modal volumes. Here, we demonstrate the design and fabrication of a high-Q (>10{sup 4}) slot-mode PhC nanobeam cavity, which is able to strongly confine light in the slotted regions. The enhanced light-matter interaction results in an order of magnitude improvement in both refractive index sensitivity (439 nm/RIU) and single-nanoparticle sensitivity compared with conventional dielectric-mode PhC cavities. Detection of single polystyrene nanoparticles with radii of 20 nm and 30 nm is demonstrated in aqueous environments (D{sub 2}O), without additional laser and temperature stabilization techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Q lattice mode matched structural resonances in terahertz metasurfaces

The quality (Q) factor of metamaterial resonances is limited by the radiative and non-radiative losses. At terahertz frequencies, the dominant loss channel is radiative in nature since the non-radiative losses are low due to high conductivity of metals. Radiative losses could be suppressed by engineering the meta-atom structure. However, such suppression usually occurs at the fundamental resonance mode which is typically a closed mode resonance such as an inductive-capacitive resonance or a Fano resonance. Here, we report an order of magnitude enhancement in Q factor of all the structural eigenresonances of a split-ring resonator fueled by the lattice mode matching. We match the fundamental order diffractive mode to each of the odd and even eigenresonances, thus leading to a tremendous line-narrowing of all the resonances. Such precise tailoring and control of the structural resonances in a metasurface lattice could have potential applications in low-loss devices, sensing, and design of high-Q metamaterial cavities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of morphology-dependent resonances by openness in dielectric disks for TE polarization

We have studied the parametric evolution of morphology-dependent resonances according to the change of openness in a two-dimensional dielectric microdisk for transverse-electric polarization. We found that the dynamics exhibit avoided resonance crossings between the inner and outer resonances even though the corresponding billiard is integrable. Due to these recondite avoidances, inner and outer resonances can be exchanged and the quality (Q) factor of inner resonances is strongly affected. We analyze the diverse phenomena arising from these dynamics including the avoided crossings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-phase-noise surface-acoustic-wave oscillator using an edge mode of a phononic band gap

Low-phase-noise microwave-frequency integrated oscillators provide compact solutions for various applications in signal processing, communications, and sensing. Surface acoustic waves (SAWs), featuring orders-of-magnitude shorter wavelength than electromagnetic waves at the same frequency, enable integrated microwave-frequency systems with much smaller footprint on chip. SAW devices also allow higher-quality (Q) factors than electronic components at room temperature. Here, we demonstrate a low-phase-noise gigahertz-frequency SAW oscillator on 128°Y-cut lithium niobate, where the SAW resonator occupies a footprint of 0.05 mm 2 . Leveraging phononic crystal band-gap-edge modes to balance between Q factors and insertion losses, our 1-GHz SAW oscillator features a low phase noise of -132.5 dBc/Hz at a 10-kHz offset frequency and an overlapping Hadamard deviation of 6.5 × 10 -10 at an analysis time of 64 ms. The SAW resonator-based oscillator holds high potential in developing low-noise sensors and acousto-optic integrated circuits.

42 ENGINEERING↗

Dual-Band Polarization Control with Pairwise Positioning of Polarization Singularities in Metasurfaces

Emerging applications of metasurfaces in classical and quantum optics are driving the need for precise polarization control of nearly-degenerate, high quality (𝑄)-factor modes. However, current approaches to creating specifically polarized pairs of modes force a trade-off between maintaining high 𝑄 factors and robustness. Here, we solve this challenge by employing pairwise generation, annihilation, and positioning of polarization singularities, derived from symmetry-guaranteed pairs of symmetry-protected bound states in the continuum. We experimentally demonstrate this design paradigm in silicon metasurfaces with mode splittings of ≈ 20 nm, mode splitting deviations as low as 1 nm, and 𝑄 factors up to 200. Furthermore, this approach opens new avenues for enhancing metasurface performance across a diverse range of applications, including sensing, modulating, nonlinear mixing, and generating quantum light.

Metasurfaces↗

Comparison of Spherical Antennas Fabricated via Conformal Printing: Helix, Meanderline, and Hybrid Designs

The design tradeoffs between three spherically conformal electric monopoles-the spherical helix (SH), spherical meanderline (SM), and a hybrid design-are explored through both simulation and measurement. We show that the SH is efficient, but can be difficult to impedance match without external components. On the other hand, the SM antenna has a widely controllable impedance with slightly increased loss. Thus, a hybrid design is proposed that retains the desirable qualities of both the SH and SM. All three designs are fabricated using a conformal printing technique for comparison. Here, we describe the design tradeoffs and physical insights gained through evaluating the efficiency, Q , and matching behavior of these antennas.

42 ENGINEERING↗

Penetration Through Slots in Cylindrical Cavities Operating at Fundamental Cavity Modes

In this article, we examine the coupling into an electrically short azimuthal slot on a cylindrical cavity operating at fundamental cavity modal frequencies. We first develop a matched bound formulation through which we can gather information for maximum achievable levels of interior cavity fields. Actual field levels are below this matched bound; therefore, we also develop an unmatched formulation for frequencies below the slot resonance to achieve a better insight on the physics of this coupling. Good agreement is observed between the unmatched formulation, full-wave simulations, and experimental data, providing a validation of our analytical models. We then extend the unmatched formulation to treat an array of slots, found again in good agreement with full-wave simulations. These analytical models can be used to investigate ways to mitigate electromagnetic interference and electromagnetic compatibility effects within cavities.

42 ENGINEERING↗

Determination of the beam quality index of high-energy photon beams under nonstandard reference conditions

Purpose: At some modern radiotherapy machines it is not possible to achieve reference conditions for the measurement of beam quality indices used in dosimetry codes of practice, such as IAEA TRS-398 and AAPM TG-51. This work aims at providing self-consistent and simpler expressions and more accurate fits for a limited range of beams of interest than have been proposed previously for deriving these beam quality indices from measurements. Methods: The starting point is a formula proposed by Sauer [Med. Phys. 36, 4168-4172 (2009)] for deriving the beam quality index used in IAEA TRS-398, TPR{sub 20,10}, from a measurement of the tissue phantom ratio at depths of 20 cm and 10 cm in water for an s Multiplication-Sign s cm{sup 2} (equivalent) square field, TPR{sub 20,10}(s). First, a self-consistent version of this formula is established followed by a simpler version by making a linear approximation. A similar approach is proposed to derive the beam quality index used in AAPM TG-51, %dd(10){sub X}, from a measurement of PDD{sub 10}(s), the percentage depth dose at 10 cm for a square field with size s. All models were fitted to subsets of relevant data from BJR supplement 25. Results: The linear models for TPR{sub 20,10}(s) and exponential models for PDD{sub 10}(s) as a function of the (equivalent) square field size can reproduce the beam quality within 0.3% and beam quality correction factors within 0.05% for square field sizes ranging from 4 cm to 12 cm and nominal photon energies from 4 MV to 12 MV. For higher energy beams the errors are only slightly worse but for %dd(10){sub X}, an additional uncertainty component has to be considered for the electron contamination correction. Conclusions: The models proposed here can be used in practical recommendations for the dosimetry of small and nonstandard fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-T-01: Calculation of KQ for a Variety of Commercially Available Ionization Chambers in the Presence of An External Magnetic Field for MR-Linac Dosimetry

Purpose: The strong magnetic fields associated with MRI have a significant impact on the dosimetry of radiotherapy beams as well as on the response of the detectors used to measure it. In order to calibrate the dose delivered by these beams, it is necessary to correct for these effects when performing measurements with ionization chambers. Methods: Detailed models of 16 commercially-available ionization chambers were implemented in Geant4. To validate these models, calculations of the beam quality correction factor kQ (defined by TG-51) were performed using the spectrum from a 6 MV Elekta SL25. kQ values were then recalculated for each detector with a 1.5 T external magnetic field applied uniformly across the geometry. Chamber, beam and B-field were all orthogonal. Results: The comparison between the kQ calculations and TG-51 showed agreement within 1.4%. The B-field calculations indicate that the change in kQ values due to the B-field is strongly affected by the volume and material of the ionization chamber. All large volume (>0.5 cm {sup 3}) ionization chambers had lower kQ values when used in a B-field. The kQ values for small volume chambers were very sensitive to the chambers’ collecting volume and could be higher or lower when used in a B-field. Conclusions: Of the chambers tested, the PTW 30011 demonstrated the smallest correction of just 1.2%. The next step is to calculate kQ using the energy spectrum from an actual MR-linac. Further validation of these results against measurements will be paramount before they can be used. Funding provided by Elekta Limited. The MR-linac spectrum will be provided by Elekta Limited based on a machine they have designed.

60 APPLIED LIFE SCIENCES↗

Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields

Purpose: Modern radiotherapy modalities often use small or nonstandard fields to ensure highly localized and precise dose delivery, challenging conventional clinical dosimetry protocols. The emergence of preclinical spatially fractionated synchrotron radiotherapies with high dose-rate, sub-millimetric parallel kilovoltage x-ray beams, has pushed clinical dosimetry to its limit. A commercially available synthetic single crystal diamond detector designed for small field dosimetry has been characterized to assess its potential as a dosimeter for synchrotron microbeam and minibeam radiotherapy. Methods: Experiments were carried out using a synthetic diamond detector on the imaging and medical beamline (IMBL) at the Australian Synchrotron. The energy dependence of the detector was characterized by cross-referencing with a calibrated ionization chamber in monoenergetic beams in the energy range 30–120 keV. The dose-rate dependence was measured in the range 1–700 Gy/s. Dosimetric quantities were measured in filtered white beams, with a weighted mean energy of 95 keV, in broadbeam and spatially fractionated geometries, and compared to reference dosimeters. Results: The detector exhibits an energy dependence; however, beam quality correction factors (k{sub Q}) have been measured for energies in the range 30–120 keV. The k{sub Q} factor for the weighted mean energy of the IMBL radiotherapy spectrum, 95 keV, is 1.05 ± 0.09. The detector response is independent of dose-rate in the range 1–700 Gy/s. The percentage depth dose curves measured by the diamond detector were compared to ionization chambers and agreed to within 2%. Profile measurements of microbeam and minibeam arrays were performed. The beams are well resolved and the full width at halfmaximum agrees with the nominal width of the beams. The peak to valley dose ratio (PVDR) calculated from the profiles at various depths in water agrees within experimental error with PVDR calculations from Gafchromic film data. Conclusions: The synthetic diamond detector is now well characterized and will be used to develop an experimental dosimetry protocol for spatially fractionated synchrotron radiotherapy.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factors were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.

07 ISOTOPE AND RADIATION SOURCES↗

Poster - 19: Investigation of Electron Reference Dosimetry Based on Optimal Chamber Shift

An addendum/revision to AAPM TG-51 electron reference dosimetry is highly expected to meet the clinical requirement with the increasing usage of new ion chambers not covered in TG-51. A recent study, Med. Phys. 41, 111701, proposed a new fitting equation for the beam quality conversion factor k’{sub Q} to a wide spectrum of chambers. In the study, an optimal Effective Point of Measurement (EPOM) from Monte Carlo calculations was recommended and the fitting parameters to k’{sub Q} was based on it. We investigated the absolute dose obtained based on the optimal EPOM method and the original TG-51 method with k’{sub R50} determined differently. The results showed that using the Markus curve is a better choice than the well-guarded chamber fitting for an IBA PPC-05 parallel plate chamber if we need to strictly follow the AAPM TG-51 protocol. We also examined the usage of the new fitting equation with measurement performed at the physical EPOM, instead of the optimal EPOM. The former is more readily determined and more practical in clinics. Our study indicated that the k’{sub Q} fitting based on the optimal EPOM can be used to measurement at the physical EPOM with no significant clinical impact. The inclusion of Farmer chamber gradient correction P{sub gr} in k’{sub Q}, as in the mentioned study, asks for the precise positioning of chamber center at dref. It is not recommended in clinics to avoid over-correction for low electron energies, especially for an institute having matching Linacs implemented.

60 APPLIED LIFE SCIENCES↗

Mechanical assembly of complex, 3D mesostructures from releasable multilayers of advanced materials

Capabilities for assembly of three-dimensional (3D) micro/nanostructures in advanced materials have important implications across a broad range of application areas, reaching nearly every class of microsystem technology. Approaches that rely on the controlled, compressive buckling of 2D precursors are promising because of their demonstrated compatibility with the most sophisticated planar technologies, where materials include inorganic semiconductors, polymers, metals, and various heterogeneous combinations, spanning length scales from submicrometer to centimeter dimensions. We introduce a set of fabrication techniques and design concepts that bypass certain constraints set by the underlying physics and geometrical properties of the assembly processes associated with the original versions of these methods. In particular, the use of releasable, multilayer 2D precursors provides access to complex 3D topologies, including dense architectures with nested layouts, controlled points of entanglement, and other previously unobtainable layouts. Furthermore, the simultaneous, coordinated assembly of additional structures can enhance the structural stability and drive the motion of extended features in these systems. The resulting 3D mesostructures, demonstrated in a diverse set of more than 40 different examples with feature sizes from micrometers to centimeters, offer unique possibilities in device design. In conclusion, a 3D spiral inductor for near-field communication represents an example where these ideas enable enhanced quality ( Q ) factors and broader working angles compared to those of conventional 2D counterparts.

36 MATERIALS SCIENCE↗

Observation of bound states in the continuum embedded in symmetry bandgaps

In the past decade, symmetry-protected bound states in the continuum (BICs) have proven to be an important design principle for creating and enhancing devices reliant upon states with high-quality (Q) factors, such as sensors, lasers, and those for harmonic generation. However, as we show, current implementations of symmetry-protected BICs in photonic crystal slabs can only be found at the center of the Brillouin zone and below the Bragg diffraction limit, which fundamentally restricts their use to single-frequency applications. By microprinting a three-dimensional (3D) photonic crystal structure using two-photon polymerization, we demonstrate that this limitation can be overcome by altering the radiative environment surrounding the slab to be a 3D photonic crystal. This allows for the protection of a line of BICs by embedding it in a symmetry bandgap of the crystal. This concept substantially expands the design freedom available for developing next-generation devices with high-Q states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗