Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Sequestration and release of nitrite and nitrate in alkali-activated slag: A route toward smart corrosion control

Intercalating the corrosion inhibitive ions in hydrotalcite is a promising approach to improve the long-term efficiency of inhibitors in corrosion protection of steel in reinforced concrete. In this work, the potential of autogenously generating nitrite- and nitrate-intercalated hydrotalcite in alkali-activated slag (AAS) is investigated. The results show that the added nitrite and nitrate ions are preferably uptaken in the interlayer structure of hydrotalcite in AAS, and the sequestered nitrite and nitrate are released upon chloride exposure in seawater and NaCl solution. The incorporation of nitrite and nitrate has little detrimental effects on the chloride binding capacity of AAS but slightly enhances the chloride ingress due to the pore coarsening effect. Similar to ordinary Portland cement (OPC), AAS is more permeable to the chloride in seawater than NaCl solution. However, unlike the release of bound chloride contributed by ettringite formation in seawater-exposed OPC, the enhanced chloride ingress in seawater-exposed AAS is primarily attributed to the aggravated pH reduction at the exposure front due to brucite formation. This study contributes to the design of alkali-activated binders with a smart inhibitor releasing ability for mitigating corrosion of steel in concrete.

36 MATERIALS SCIENCE↗

Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC

Purpose: Advanced high quality radiation therapy techniques such as IMRT require an accurate delivery of precisely modulated radiation fields to the target volume. Interfractional and intrafractional motion of the patient's anatomy, however, may considerably deteriorate the accuracy of the delivered dose to the planned dose distributions. In order to compensate for these potential errors, a dynamic real-time capable MLC control system was designed. Methods: The newly developed adaptive MLC control system contains specialized algorithms which are capable of continuous optimization and correction of the aperture of the MLC according to the motion of the target volume during the dose delivery. The algorithms calculate the new leaf positions based on target information provided online to the system. The algorithms were implemented in a dynamic target tracking control system designed for a Siemens 160 MLC. To assess the quality of the new target tracking system in terms of dosimetric accuracy, experiments with various types of motion patterns using different phantom setups were performed. The phantoms were equipped with radiochromic films placed between solid water slabs. Dosimetric results of exemplary deliveries to moving targets with and without dynamic MLC tracking applied were compared in terms of the gamma criterion to the reference dose delivered to a static phantom. Results: Our measurements indicated that dose errors for clinically relevant two-dimensional target motion can be compensated by the new control system during the dose delivery of open fields. For a clinical IMRT dose distribution, the gamma success rate was increased from 19% to 77% using the new tracking system. Similar improvements were achieved for the delivery of a complete IMRT treatment fraction to a moving lung phantom. However, dosimetric accuracy was limited by the system's latency of 400 ms and the finite leaf width of 5 mm in the isocenter plane. Conclusions: Different experimental setups representing different target tracking scenarios proved that the tracking concept, the new algorithms and the dynamic control system make it possible to effectively compensate for dose errors due to target motion in real-time. These early results indicate that the method is suited to increasing the accuracy and the quality of the treatment delivery for the irradiation of moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

NSLS-II Beam Loss Control and Monitoring System

One of the most challenging issues for accelerator operations deals with why and where the beam was lost. This is a major concern for radiation protection at facilities with a large user base, since uncontrolled beam losses could result in high radiation levels to occupied areas. For NSLS-II the tunnel radiation shield wall has increased attenuation over two lattice cells after the injection region, to shield for the possibility of higher injection losses during injection. This raised the concern over exceeding the radiation exposure limits in the lesser shielded region, if similar losses could occur elsewhere. To address this issue a beam loss control system was designed to capture most beam losses in the more heavily shielded (injection) region. A beam loss monitor system was designed to verify the fraction of the beam lost in that region, in order to insure lower levels of exposure around the rest of the ring. The design of these beam loss control and monitoring systems and their operational experience are presented here.

43 PARTICLE ACCELERATORS↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twin for Self-Security of Smart Inverters

Smart inverters connected to a communication network are susceptible to man-in-the-middle attacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s normal operating region and the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates how the inverter’s normal operating region and dynamic model are formed. In particular, the normal operation region is experimentally verified by changing the P and Q setpoints engaged to the local controller, using a laboratory setup including a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the self-security technique can potentially protect inverters from man-in-the-middle attacks by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Prophylactic treatment with PEGylated bovine IFNλ3 effectively bridges the gap in vaccine-induced immunity against FMD in cattle

Foot-and-mouth disease (FMD) is a vesicular disease of cloven-hoofed animals with devastating economic implications. The current FMD vaccine, routinely used in enzootic countries, requires at least 7 days to induce protection. However, FMD vaccination is typically not recommended for use in non-enzootic areas, underscoring the need to develop new fast-acting therapies for FMD control during outbreaks. Interferons (IFNs) are among the immune system’s first line of defense against viral infections. Bovine type III IFN delivered by a replication defective adenovirus (Ad) vector has effectively blocked FMD in cattle. However, the limited duration of protection—usually only 1–3 days post-treatment (dpt)—diminishes its utility as a field therapeutic. Here, we test whether polyethylene glycosylation (PEGylation) of recombinant bovine IFNλ3 (PEGboIFNλ3) can extend the duration of IFN-induced prevention of FMDV infection in both vaccinated and unvaccinated cattle. We treated groups of heifers with PEGboIFNλ3 alone or in combination with an adenovirus-based FMD O1Manisa vaccine (Adt-O1M) at either 3 or 5 days prior to challenge with homologous wild type FMDV. We found that pre-treatment with PEGboIFNλ3 was highly effective at preventing clinical FMD when administered at either time point, with or without co-administration of Adt-O1M vaccine. PEGboIFNλ3 protein was detectable systemically for >10 days and antiviral activity for 4 days following administration. Furthermore, in combination with Adt-O1M vaccine, we observed a strong induction of FMDV-specific IFNγ+ T cell response, demonstrating its adjuvanticity when co-administered with a vaccine. Our results demonstrate the promise of this modified IFN as a pre-exposure prophylactic therapy for use in emergency outbreak scenarios.

biotherapeutics↗

Chemical compositions, pharmacological activities, quality control studies of Erycibes plants, and the development of their substitutes

Erycibes are members of the Convolvulaceae family, including more than 10 species worldwide that are distributed in tropical Asia. Some Erycibes species have long been used as traditional remedies for rheumatoid arthritis, fever, hepatitis, and liver injury in China and Thailand. A total of 152 compounds from Erycibes plants have been isolated and identified, categorized as flavonoids, coumarins, quinic acid derivatives, lignans, and alkaloids. Coumarins are the characteristic and active constituents of this species, including scopoletin and scopolin. Modern pharmacological studies have shown that the extracts and bioactive components of Erycibes plants exhibit several biological activities, including antiinflammatory, analgesic, hepatoprotective, anti‐gout, antitumor, antioxidation, and other therapeutic effects. However, in recent years, due to destructive exploitation and utilization, some Erycibes plants' natural resources have become rare or endangered. Developing substitutes is a strategy to alleviate the pressure on those endangered medicinal plant resources. To provide a scientific basis for the development and protection of those threatened Erycibes species, this review summarized the current status of the chemical compositions, pharmacological activities, quality control studies, and the development of substitutes for Erycibes plants. In particular, the rationale for use of Porana sinensis currently on the market is discussed.

Peng, Yu↗

Conventional and Next Generation Treatment Technologies for PFAS - 20067

In 2016, the United States Environmental Protection Agency (USEPA) established a Health Advisory Limit (HAL) for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) (individually and the summation) of 70 nanograms per liter (ng/L) based on developing toxicological information. These two compounds are among several thousand per- and polyfluoroalkyl substances (PFAS). Due to a multitude of commercially beneficial physical and chemical properties, the availability of PFAS-relevant and practical water treatment technologies is limited. The use of conventional adsorbents, such as activated carbon (AC) and anion exchange (AIX) resins, have become a 'de facto' interim measure to immediately address drinking water above this criterion. However, these adsorbents can have marginal long-term efficiency and are relatively unproven against the diversity of polyfluorinated compounds. Additionally, geochemical and/or co-contaminant competition can significantly impede adsorption based PFAS removal. These challenges may be addressed using engineered filtration, such as reverse osmosis or nanofiltration (RO/NF); however, for larger flow systems RO/NF may have unacceptable reject ratios as high as 35% and the capital cost may preclude these technologies. Extending these technologies to natural waters, which have various degrees of geochemical and co-contaminant competition, often requires a treatment train, combining conventional adsorbents or engineered filtration with pretreatment and more innovative and emerging remediation solutions for PFAS. Conventional and Next Generation water treatment technologies for PFAS generally employ one of three mechanisms (adsorption, separation, or destruction). These mechanisms include many types of technologies for both municipal drinking water and extracted natural water applications. The previously mentioned AC, AIX, and RO/NF are commercially available technologies that are actively being deployed for PFAS treatment. Research and development around these technologies is focused on optimization, and ultimate destruction of PFAS is achieved through incineration. Next Generation water treatment technologies include PFAS-specific flocculants, foam fractionation, novel AIX resins, new engineered adsorptive media, electrochemical treatment, sonolysis, and photolysis, radiation, and plasma (forms of advanced reductive processes [ARP]). Research and development around these technologies is focused on proof of concept and assimilation to real world applications. As the PFAS-relevant destructive technologies (such as incineration, electrochemical treatment, sonolysis, and ARP) are energy intensive, the state of the practice for PFAS water treatment is to focus adsorption/separation based technologies on reducing and concentrating the volume of water requiring destructive treatment. This enables more flexibility with respect to circulation frequency, residence time, and more control over energy usage. Water treatment for PFAS presently requires multiple technologies (i.e. a treatment train) to protect human health in a cost-conscious manner. An investment in research and development to explore new technologies is part of a key initiative for efficient protection of human health. This presentation attempts to review PFAS-relevant water treatment technologies and provide perspective as to their status with respect to applicability and commercial relevance. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SU-F-T-245: The Investigation of Failure Mode and Effects Analysis and PDCA for the Radiotherapy Risk Reduction

Purpose: To optimize the clinical processes of radiotherapy and to reduce the radiotherapy risks by implementing the powerful risk management tools of failure mode and effects analysis(FMEA) and PDCA(plan-do-check-act). Methods: A multidiciplinary QA(Quality Assurance) team from our department consisting of oncologists, physicists, dosimetrists, therapists and administrator was established and an entire workflow QA process management using FMEA and PDCA tools was implemented for the whole treatment process. After the primary process tree was created, the failure modes and Risk priority numbers(RPNs) were determined by each member, and then the RPNs were averaged after team discussion. Results: 3 of 9 failure modes with RPN above 100 in the practice were identified in the first PDCA cycle, which were further analyzed to investigate the RPNs: including of patient registration error, prescription error and treating wrong patient. New process controls reduced the occurrence, or detectability scores from the top 3 failure modes. Two important corrective actions reduced the highest RPNs from 300 to 50, and the error rate of radiotherapy decreased remarkably. Conclusion: FMEA and PDCA are helpful in identifying potential problems in the radiotherapy process, which was proven to improve the safety, quality and efficiency of radiation therapy in our department. The implementation of the FMEA approach may improve the understanding of the overall process of radiotherapy while may identify potential flaws in the whole process. Further more, repeating the PDCA cycle can bring us closer to the goal: higher safety and accuracy radiotherapy.

60 APPLIED LIFE SCIENCES↗

Direct intratumoral infusion of liposome encapsulated rhenium radionuclides for cancer therapy: Effects of nonuniform intratumoral dose distribution

Purpose: Focused radiation therapy by direct intratumoral infusion of lipid nanoparticle (liposome)-carried beta-emitting radionuclides has shown promising results in animal model studies; however, little is known about the impact the intratumoral liposomal radionuclide distribution may have on tumor control. The primary objective of this work was to investigate the effects the intratumoral absorbed dose distributions from this cancer therapy modality have on tumor control and treatment planning by combining dosimetric and radiobiological modeling with in vivo imaging data. Methods: {sup 99m}Tc-encapsulated liposomes were intratumorally infused with a single injection location to human head and neck squamous cell carcinoma xenografts in nude rats. High resolution in vivo planar imaging was performed at various time points for quantifying intratumoral retention following infusion. The intratumoral liposomal radioactivity distribution was obtained from 1 mm resolution pinhole collimator SPECT imaging coregistered with CT imaging of excised tumors at 20 h postinfusion. Coregistered images were used for intratumoral dosimetric and radiobiological modeling at a voxel level following extrapolation to the therapeutic analogs, {sup 186}Re/{sup 188}Re liposomes. Effective uniform dose (EUD) and tumor control probability (TCP) were used to assess therapy effectiveness and possible methods of improving upon tumor control with this radiation therapy modality. Results: Dosimetric analysis showed that average tumor absorbed doses of 8.6 Gy/MBq (318.2 Gy/mCi) and 5.7 Gy/MBq (209.1 Gy/mCi) could be delivered with this protocol of radiation delivery for {sup 186}Re/{sup 188}Re liposomes, respectively, and 37-92 MBq (1-2.5 mCi)/g tumor administered activity; however, large intratumoral absorbed dose heterogeneity, as seen in dose-volume histograms, resulted in insignificant values of EUD and TCP for achieving tumor control. It is indicated that the use of liposomes encapsulating radionuclides with higher energy beta emissions, dose escalation through increased specific activity, and increasing the number of direct tumor infusion sites improve tumor control. For larger tumors, the use of multiple infusion locations was modeled to be much more efficient, in terms of activity usage, at improving EUD and TCP to achieve a tumoricidal effect. Conclusions: Direct intratumoral infusion of beta-emitting radionuclide encapsulated liposomes shows promise for cancer therapy by achieving large focally delivered tumor doses. However, the results of this work also indicate that average tumor dose may underestimate tumoricidal effect due to substantial heterogeneity in intratumoral liposomal radionuclide distributions. The resulting intratumoral distribution of liposomes following infusion should be taken into account in treatment planning and evaluation in a clinical setting for an optimal cancer therapy.

60 APPLIED LIFE SCIENCES↗

Symbiont-Mediated Protection of Acromyrmex Leaf-Cutter Ants from the Entomopathogenic Fungus Metarhizium anisopliae

Many fungus-growing ants engage in a defensive symbiosis with antibiotic-producing ectosymbiotic bacteria in the genus Pseudonocardia, which help protect the ants’ fungal mutualist from a specialized mycoparasite, Escovopsis. Here, using germfree ant rearing and experimental pathogen infection treatments, we evaluate if Acromyrmex ants derive higher immunity to the entomopathogenic fungus Metarhizium anisopliae from their Pseudonocardia symbionts. We further examine the ecological dynamics and defensive capacities of Pseudonocardia against M. anisopliae across seven different Acromyrmex species by controlling Pseudonocardia acquisition using ant-nonnative Pseudonocardia switches, in vitro challenges, and in situ mass spectrometry imaging (MSI). We show that Pseudonocardia protects the ants against M. anisopliae across different Acromyrmex species and appears to afford higher protection than metapleural gland (MG) secretions. Although Acromyrmex echinatior ants with nonnative Pseudonocardia symbionts receive protection from M. anisopliae regardless of the strain acquired compared with Pseudonocardia-free conditions, we find significant variation in the degree of protection conferred by different Pseudonocardia strains. Additionally, when ants were reared in Pseudonocardia-free conditions, some species exhibit more susceptibility to M. anisopliae than others, indicating that some ant species depend more on defensive symbionts than others. In vitro challenge experiments indicate that Pseudonocardia reduces Metarhizium conidiospore germination area. Our chemometric analysis using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) reveals that Pseudonocardia-carrying ants produce more chemical signals than Pseudonocardia-free treatments, indicating that Pseudonocardia produces bioactive metabolites on the Acromyrmex cuticle. Our results indicate that Pseudonocardia can serve as a dual-purpose defensive symbiont, conferring increased immunity for both the obligate fungal mutualist and the ants themselves.

59 BASIC BIOLOGICAL SCIENCES↗

Contested environmental policy infrastructure: Socio-political acceptance of renewable energy, water, and waste facilities

The construction of new infrastructure is hotly contested. This paper presents a comparative study on three environmental policy domains in the Netherlands that all deal with legitimising building and locating infrastructure facilities. Such infrastructure is usually declared essential to environmental policy and claimed to serve sustainability goals. They are considered to serve (proclaimed) public interests, while the adverse impact or risk that mainly concerns environmental values as well is concentrated at a smaller scale, for example in local communities. The social acceptance of environmental policy infrastructure is institutionally determined. The institutional capacity for learning in infrastructure decision-making processes in the following three domains is compared: 1.The implementation of wind power as a renewable energy innovation; 2.The policy on space-water adaptation, with its claim to implement a new style of management replacing the current practice of focusing on control and 'hard' infrastructure; 3.Waste policy with a focus on sound waste management and disposal, claiming a preference for waste minimization (the 'waste management hierarchy'). All three cases show a large variety of social acceptance issues, where the appraisal of the impact of siting the facilities is confronted with the desirability of the policies. In dealing with environmental conflict, the environmental capacity of the Netherlands appears to be low. The policies are frequently hotly contested within the process of infrastructure decision-making. Decision-making on infrastructure is often framed as if consensus about the objectives of environmental policies exists. These claims are not justified, and therefore stimulating the emergence of environmental conflicts that discourage social acceptance of the policies. Authorities are frequently involved in planning infrastructure that conflicts with their officially proclaimed policy objectives. In these circumstances, they are often confronted with local actors who support alternatives that are in fact better in tune with the new policy paradigm.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Examining Efficacy of Strategic Stability in South Asia: An Analysis

This paper highlights how, in the backdrop of prevalent tensions between India and Pakistan, deterrence stability is endangered even when overall strategic stability prevails. Unresolved legacy issues including an outstanding boundary dispute, conflict over Kashmir, and terrorism mar India-Pakistan relations. Variables undermining the prospects for long term peace, among others, include growing mutual mistrust, the proxy war that India believes is state perpetrated, increasing conventional asymmetry, rapid advancement in weapon technologies, growing size of nuclear arsenals, doctrinal mismatch and above all, bilateral gridlock in confidence building measures and arms control measures.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

RCT Training and Qualification

The RCT training program prepares Radiological Control Technicians to support the advancement of the laboratory’s mission objectives while ensuring the health and safety of the workforce and public from radiological hazards, utilizing a multi-disciplinary, hands-on approach. Currently located at the MESA complex within the University of New Mexico – Los Alamos Campus, the RP Training department has established an immersive training environment that simulates realistic work conditions in which RCTs may develop the fundamental knowledge and skills required to control radiological work across the Laboratory

61 RADIATION PROTECTION AND DOSIMETRY↗

The overvoltage protection module for the power supply system for the pixel detector at Belle II experiment at KEK

In this paper the overvoltage protection modules (OVP) for the power supply (PS) system of the Belle II pixel detector (PXD) are described. The aim of the OVP is to protect the detector and associated electronics against overvoltage conditions. Most critical in the system are voltages supplying the front-end ASICs. The PXD detector consists of the DEPFET sensor modules with integrated chips like the Drain Current Digitizer, the Switcher and the Data Handling Processor. These chips, implemented in modern sub-micron technologies, are quite vulnerable to variations in the supply voltages. The PXD will be placed in the Belle II experiment as close as possible to the interaction point, where access during experiment is very limited or even impossible, thus the PS and OVP systems exploit the remote-sensing method. Overvoltage conditions are due to failures of the PS itself, wrong setting of the output voltages or transient voltages coming out of hard noisy environment of the experiment. The OVP modules are parts of the PS modules. For powering the PXD 40 PS modules are placed 15 m outside the Belle II spectrometer. Each one is equipped with the OVP board. All voltages (22) are grouped in 4 domains: Analog, Digital, Steering and Gate which have independent grounds. The OVP boards are designed from integrated circuits from Linear Technology. All configurations were simulated with the Spice program. The control electronics is designed in a Xilinx CPLD. Two types of integrated circuits were used. LT4356 surge stopper protects loads from high voltage transients. The output voltages are limited to a safe value and also protect loads against over current faults. For less critical voltages, the LTC2912 voltage monitors are used that detect under-voltage and overvoltage events. It has to be noted that the OVP system is working independently of any other protection of the PS system, which increases its overall reliability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-206-00: Diagnostic QA/QC Hands-On Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗