Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gain and Phase-margin measurements

Simple battery-powered test circuit will contribute negligible error when taking open-loop measurements of gain and phase parameters. This is especially helpful when measuring high-grain circuits containing integrators.

Pierce, B. D.↗

High Temperature Fission Chamber for He- and FLiBe-cooled Reactors

We have evaluated candidate technologies for in-core fission chambers for high-temperature reactors to monitor power level via measurements of neutron flux from start-up through full power at up to 800°C. This research is important because there are no commercially available instruments capable of operating above 550 °C. Component materials and processes were investigated for fission chambers suitable for operation at 800 °C in reactors cooled by molten fluoride salt (FLiBe) or flowing He, with an emphasis placed on sensitivity (≥ 1 cps/nv), service lifetime (2 years at full power), and resistance to direct immersion in FLiBe. The latter gives the instrument the ability to survive accidents involving breach of a thimble. The device is envisioned to be a two-gap, three-electrode instrument constructed from concentric nickel-plated alumina cylinders and using a noble gas–nitrogen fill-gas. We report the results of measurements and calculations of the response of fill gasses, impurity migration in nickel alloy, brazing of the alumina insulator, and thermodynamic calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEAMER: Water Tunnel Data from Testing the Pterofin Skimmer Concept

Pterofin's Skimmer concept relies on a flapping and pitching hydrofoil to extract hydrokinetic energy from water flows. The concept aims to utilize unsteady fluid dynamics phenomena (added mass, shed vorticity, and unsteady boundary layer development) to achieve higher lift coefficients, enabling increased power density of the hydrokinetic device and a fundamental shift in the rpm/torque scaling of the power take off compared with turbines. The Applied Research Laboratory at Penn State, in collaboration with Pterofin, designed and built a proof-of-concept flapping/pitching mechanism which was subsequently tested in ARL's 12-inch water tunnel facility. The mechanical power supplied to or extracted from the mechanism was measured for a range of hydrofoils provided by Pterofin over operating conditions including reduced frequency, Reynolds number, and the ratio between pitching and flapping amplitudes. The power lost to friction in the mechanism was removed from the net power measurement by means of a bare hub tare, with the resultant hydrodynamic power being used to calculate a mechanism-independent and non-dimensional power coefficient. The product of this effort is a dataset describing the power coefficient of a hydrofoil having simultaneous pitching and flapping motions, both of which are approximately sinusoidal. Power coefficients were collected for a range of primary design variables including: - Reduced frequency: 0.01 to 0.95 - Pitching/flapping peak angle ratio: 1.5 to 3.0 - Chord-based Reynolds number: 60,000 to 560,000 Secondary design variables relating to the hydrofoil geometry were explored including: - Aspect ratio - Planform shape - Section thickness distribution - Hydrofoil position relative to the pitching axis - Hydrofoil sweep angle relative to the pitching axis Measured data are provided in mean and time series formats. MATLAB scripts are provided which can be used to generate figures of time-averaged and phase-averaged hydrodynamic power coefficients calculated from the measured data. A complete description of the experiment and data reduction can be found in the Post Access Report for the Pterofin Skimmer test effort which will be available on the TEAMER website. This work was supported by the Pacific Energy Ocean Trust via a TEAMER award.

16 TIDAL AND WAVE POWER↗

Precision Small Scattering Angle Measurements of Proton–Proton and Proton–Nucleus Analyzing Powers at the RHIC Hydrogen Jet Polarimeter

At RHIC, the hydrogen jet target polarimeter (HJET) is used to measure proton beam polarization with accuracy $σ^{syst}_{P}$ / $P$ ≲ 0.5% by counting low energy (1–10 MeV) recoil protons in left-right symmetric detectors. The HJET performance also allowed us to precisely measure $pp$ and $pA$ (where $A$ is any ion stored at RHIC) analyzing powers in the CNI region. The results of the measurements are discussed.

43 PARTICLE ACCELERATORS↗

Measurement Accuracy Limitation Analysis on Synchrophasors

This paper analyzes the theoretical accuracy limitation of synchrophasors measurements on phase angle and frequency of the power grid. Factors that cause the measurement error are analyzed, including error sources in the instruments and in the power grid signal. Different scenarios of these factors are evaluated according to the normal operation status of power grid measurement. Based on the evaluation and simulation, the errors of phase angle and frequency caused by each factor are calculated and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ionospheric wave spectrum measurements

The local spectrum S(k, omega) of either potential or electron-density fluctuations can be used to determine macroscopic-plasma characteristics such as the local density and temperature, transport coefficients, and drift current. This local spectrum can be determined by measuring the cross-power spectrum. The paper examines the practicality of using the cross-power spectrum analyzer on the Space Shuttle to measure ionospheric parameters. Particular attention is given to investigating the integration time required to measure the cross-power spectral density to a desired accuracy.

Harker, K. J.↗

Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear polarization sensitivity specifications for space-borne instruments

The radiometric accuracy of space-borne instruments such as radiometers and spectroradiometers which make measurements of the earth and other celestial objects can be compromised by the linear polarization sensitivity (LPS) induced by the optical system. Most of these optical systems contain optical elements whose reflectance or transmission is polarization dependent, such as diffraction gratings, folding and scanning mirrors, dichroic filters, and optical fibers. Optical system incorporating such elements generally display linear polarization sensitivity; different linear polarization states incident with equal radiometric power will be measured as different power levels. If the incident polarization state is unknown, the linear polarization sensitivity cannot be compensated during the data reduction. The light reflected from the earth and other planets and moons is usually partially linearly polarized, but in a random distribution. Thus, to make accurate radiometric measurements of these bodies, a radiometer or spectrometer should have a low level of linear polarization sensitivity. This paper contains a mathematical description of LPS, contains references to systems which have imposed a LPS specification, describes some of the sources of LPS, describes how to model LPS by polarization ray tracing, and discusses methods to reduce the LPS of an optical system.

Maymon, Peter W.↗

London penetration depth measurements in Ba (Fe 1-x T x ) 2 As 2 (T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors

The London penetration depth has been measured in various doping levels of single crystals of Ba(Fe 1-x T x ) 2 As 2 (T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors by utilizing a tunnel diode resonator (TDR) apparatus. All in-plane penetration depth measurements exhibit a power law temperature dependence of the form Δλ ab (T) = CT n , indicating the existence of low-temperature, normal state quasiparticles all the way down to the lowest measured temperature, which was typically 500 mK. Several different doping concentrations from the Ba(Fe 1-x T x ) 2 As 2 (T=Co,Ni) systems have been measured and the doping dependence of the power law exponent, n, is compared to results from measurements of thermal conductivity and specific heat. In addition, a novel method has been developed to allow for the measurement of the zero temperature value of the in-plane penetration depth, λ ab (0), by using TDR frequency shifts. By using this technique, the doping dependence of λ ab (0) has been measured in the Ba(Fe 1-x Co x ) 2 As 2 series, which has allowed also for the construction of the doping-dependent superfluid phase stiffness, ρ s (T) = [λ(0)/λ(T)] 2 . By studying the effects of disorder on these superconductors using heavy ion irradiation, it has been determined that the observed power law temperature dependence likely arises from pair-breaking impurity scattering contributions, which is consistent with the proposed s±-wave symmetry of the superconducting gap in the dirty scattering limit. This hypothesis is supported by the measurement of an exponential temperature dependence of the penetration depth in the intrinsically clean LiFeAs, indicative of a nodeless superconducting gap.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Thermoluminescence Spectroscopy as a Research Tool for Semiconductor and Photonic Materials: A Review and Perspective

Thermoluminescence (TL) or thermally stimulated luminescence (TSL) spectroscopy is based on liberating charge carriers from traps in the bandgap by providing enough thermal energy to overcome the potential barrier of the traps. It provides a powerful tool to measure the positions of the localized states/traps in the bandgap. Despite that, its applications in semiconductors are very limited. Herein, the basics of TL spectroscopy and the recent advances in the technique with focus on cryogenic thermally stimulated photoemission spectroscopy (C‐TSPS) which extends TL measurements to cryogenic regime and allows the detection of very low concentrations of shallow and deep localized states is discussed. One goal herein is to introduce the reader to the use of TL and C‐TSPS in the characterization of semiconductors, explaining how it can be applied and demonstrating its advantages as a powerful tool for measuring shallow donor/acceptor ionization energies in semiconductors and as a method for characterizing compensating defects. The article also discusses interesting potential applications of C‐TSPS in new research areas such as corrosion and formation of oxide layers on metal surfaces.

36 MATERIALS SCIENCE↗

Boundary layer measurements of the OH radical in the vicinity of an isolated power plant plume - SO2 and NO2 chemical conversion times

Direct measurements of the OH radical in the vicinity of an isolated power plant plume are reported. These measurements were used to estimate the conversion time of SO2 to H2SO4-sulfate aerosol via the initiating step OH + SO2 + M yields HSO3. Using the near-high-noon measured value of OH (9.5 million per cu cm), resulted in a 1/e conversion time of 1.4 days. The latter lifetime would correspond to a conversion rate of about 2%/hr. When the lifetime calculation was modified to take into consideration the OH diurnal cycle, the 1/e conversion time for SO2 was found to be 4.4 days, giving an apparent overall rate of conversion of about 0.7%/hr. Similar calculations carried out for the conversion of NO2 to NHO3 resulted in 1/e lifetimes for NO2 of 2-3 h for midday time periods.

Davis, D. D.↗

The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: BAO measurement from the LOS-dependent power spectrum of DR12 BOSS galaxies

Here, we present an anisotropic analysis of the baryon acoustic oscillation (BAO) scale in the twelfth and final data release of the Baryon Oscillation Spectroscopic Survey (BOSS). We independently analyse the LOWZ and CMASS galaxy samples: the LOWZ sample contains 361 762 galaxies with an effective redshift of z LOWZ = 0.32; the CMASS sample consists of 777 202 galaxies with an effective redshift of z CMASS = 0.57. We extract the BAO peak position from the monopole power-spectrum moment, α 0, and from the μ 2 moment, α 2, where μ is the cosine of the angle to the line of sight. The μ 2 -moment provides equivalent information to that available in the quadrupole but is simpler to analyse. After applying a reconstruction algorithm to reduce the BAO suppression by bulk motions, we measure the BAO peak position in the monopole and μ 2 -moment, which are related to radial and angular shifts in scale. We report H(zLOWZ)r s (zd) = (11.60 ± 0.60) × 10 3 km s -1 and D A (zLOWZ)/r s (zd) = 6.66 ± 0.16 with a cross-correlation coefficient of rHD A = 0.41, for the LOWZ sample; and H(zCMASS)r s (zd) = (14.56 ± 0.37) × 10 3 km s -1 and D A (zCMASS)/r s (z d ) = 9.42 ± 0.13 with a cross-correlation coefficient of rHD A = 0.47, for the CMASS sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Hardwall acoustical characteristics and measurement capabilities of the NASA Lewis 9 x 15 foot low speed wind tunnel

Experimental evaluations of the acoustical characteristics and source sound power and directionality measurement capabilities of the NASA Lewis 9 x 15 foot low speed wind tunnel in the untreated or hardwall configuration were performed. The results indicate that source sound power estimates can be made using only settling chamber sound pressure measurements. The accuracy of these estimates, expressed as one standard deviation, can be improved from + or - 4 db to + or - 1 db if sound pressure measurements in the preparation room and diffuser are also used and source directivity information is utilized. A simple procedure is presented. Acceptably accurate measurements of source direct field acoustic radiation were found to be limited by the test section reverberant characteristics to 3.0 feet for omni-directional and highly directional sources. Wind-on noise measurements in the test section, settling chamber and preparation room were found to depend on the sixth power of tunnel velocity. The levels were compared with various analytic models. Results are presented and discussed.

Rentz, P. E.↗

Constraints on Cosmology and Baryonic Feedback with the Deep Lens Survey Using Galaxy–Galaxy and Galaxy–Mass Power Spectra

We present cosmological parameter measurements from the Deep Lens Survey (DLS) using galaxy–mass and galaxy–galaxy power spectra in the multipole range ℓ = 250–2000. We measure galaxy–galaxy power spectra from two lens bins centered at z ~ 0.27 and 0.54 and galaxy–mass power spectra by cross-correlating the positions of galaxies in these two lens bins with galaxy shapes in two source bins centered at z ~ 0.64 and 1.1. We marginalize over a baryonic feedback process using a single-parameter representation and a sum of neutrino masses, as well as photometric redshift and shear calibration systematic uncertainties. For a flat ΛCDM cosmology, we determine ${S}_{8}\equiv {\sigma }_{8}\sqrt{{{\rm{\Omega }}}_{m}/0.3}={0.810}_{-0.031}^{+0.039}$, in good agreement with our previous DLS cosmic shear and the Planck cosmic microwave background (CMB) measurements. Without the baryonic feedback marginalization, S 8 decreases by $\sim 0.05$ because the dark-matter-only power spectrum lacks the suppression at the highest ℓ values owing to active galactic nucleus (AGN) feedback. Together with the Planck CMB measurements, we constrain the baryonic feedback parameter to ${A}_{\mathrm{baryon}}={1.07}_{-0.39}^{+0.31}$, which suggests an interesting possibility that the actual AGN feedback might be stronger than the recipe used in the OverWhelmingly Large cosmological hydrodynamical Simulations. The interpretation is limited by the validity of the baryonic feedback simulation and the one-parameter representation of the effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a digital multiradian phase detector and its application in fusion plasma interferometry

We discuss the circuit design of a digital multiradian phase detector that measures the phase difference between two 10 kHz square wave TTL signals and provides the result as a binary number. The phase resolution of the circuit is 1/64 period and its dynamic range is 256 periods. This circuit has been developed for fusion plasma interferometry with submillimeter waves on the ASDEX Upgrade tokamak. The results from interferometric density measurement are discussed and compared to those obtained with the previously used phase detectors, especially with respect to the occurrence of phase jumps. It is illustrated that the new phase measurement provides a powerful tool for automatic real-time validation of the measured density, which is important for feedback algorithms that are sensitive to spurious density signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a long-slot microwave plasma source

A 20 cm long 10 cm wide microwave plasma source was realized by inserting two 20 cm long 1.5 mm diameter rod antennas into the plasma. Plasma luminous distributions around the antennas were changed by magnetic field arrangement created by permanent magnets attached to the source. The distributions appeared homogeneous in one direction along the antenna when the spacing between the antenna and the source wall was 7.5 mm for the input microwave frequency of 2.45 GHz. Plasma density and temperature at a plane 20 cm downstream from the microwave shield were measured by a Langmuir probe array at 150 W microwave power input. The measured electron density and temperature varied over space from 3.0 × 10{sup 9} cm{sup −3} to 5.8 × 10{sup 9} cm{sup −3}, and from 1.1 eV to 2.1 eV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CONSTRAINING GAMMA-RAY BURST INITIAL LORENTZ FACTOR WITH THE AFTERGLOW ONSET FEATURE AND DISCOVERY OF A TIGHT {Gamma}{sub 0}-E{sub {gamma},iso} CORRELATION

The onset of gamma-ray burst (GRB) afterglow is characterized by a smooth bump in the early afterglow light curve as the GRB fireball is decelerated by the circumburst medium. We extensively search for GRBs with such an onset feature in their optical and X-ray light curves from the literature and from the catalog established with the Swift/XRT. Twenty optically selected GRBs and 12 X-ray-selected GRBs are obtained, among which 17 optically selected and 2 X-ray-selected GRBs have redshift measurements. We fit these light curves with a smooth broken power law and measure the width (w), rising timescale (t{sub r}), and decaying timescale (t{sub d}) at full width at half-maximum. Strong mutual correlations among these timescales and with the peak time (t{sub p}) are found. The ratio t{sub r}/t{sub d} is almost universal among bursts, but the ratio t{sub r}/t{sub p} varies from 0.3 to {approx}1. The optical peak luminosity in the R band (L{sub R,p}) is anti-correlated with t{sub p} and w in the burst frame, indicating a dimmer and broader bump peaking at a later time. The isotropic prompt gamma-ray energy (E{sub {gamma},iso}) is also tightly correlated with L{sub R,p} and t{sub p} in the burst frame. Assuming that the bumps signal the deceleration of the GRB fireballs in a constant density medium, we calculate the initial Lorentz factor ({Gamma}{sub 0}) and the deceleration radius (R{sub d}) of the GRBs with redshift measurements. The derived {Gamma}{sub 0} is typically a few hundreds, and the deceleration radius is R{sub dec} {approx} 2 x 10{sup 17} cm. More intriguingly, a tight correlation between {Gamma}{sub 0} and E{sub {gamma},iso} is found, namely {Gamma}{sub 0} {approx_equal} 182(E{sub {gamma},iso}/10{sup 52} erg){sup 0.25}. This correlation also applies to the small sample of GRBs which show the signature of the afterglow onset in their X-ray afterglow, and to two bursts (GRBs 990123 and 080319B) whose early optical emission is dominated by a reverse shock. The lower limits of {Gamma}{sub 0} derived from a sample of optical afterglow light curves showing a decaying feature from the beginning of the observation are also generally consistent with such a correlation. The tight lower limits of {Gamma}{sub 0} of GRBs 080916C and 090902B derived from the opacity constraints with Fermi/LAT observations are also consistent with the correlation at the 2{sigma} confidence level, but the short GRB 090510 is a clear outlier of this relation. This correlation may give insight to GRB physics and could serve as an indicator of {Gamma}{sub 0} for long GRBs without early afterglow detections. A comparison of the early X-ray and optical afterglow light curves shows that the early bright X-ray emission is usually dominated by a non-forward-shock component, but occasionally (for one case) the forward shock emission is observable, and an achromatic deceleration feature is observed. The superposition of the internal and external components in X-rays causes the diversity of the observed X-ray light curves.

79 ASTRONOMY AND ASTROPHYSICS↗