Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PWR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Experimental study on the guillotine break accident of the main steam line with Atlas

A main steam line break (MSLB) accident is defined as a pipe break in the main steam system of a nuclear power plant. The MSLB accident is characterized as cool-down event due to the increased steam flow rate, which causes excessive energy removal from the steam generators and eventually reactor coolant system. This results in a decrease in reactor coolant temperature. The cool-down causes an increase in core reactivity due to the negative moderator and Doppler reactivity coefficients. The thermalhydraulic integral effect test was performed to simulate a double-ended guillotine break accident of the main steam line of a pressurized water reactor. With an aim of simulating the MSLB accident as realistically as possible, a pertinent scaling approach was taken, especially focusing on a break flow. The main objectives of this test were not only to provide physical insight into the system response of a nuclear power plant during the MSLB accident but also to produce an integral effect test data to validate the safety analysis codes. In the present test, asymmetric thermal-hydraulic behavior was clearly observed between the loops. In the cold leg-1A and -1B where the affected steam generator is connected, the flow rates were higher and the fluid temperatures were lower than those in the cold leg-2A and -2B. This could be attributed to the excessive heat removal in the cold leg-1A and -1B through the affected steam generator. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes. Furthermore, this data can be utilized to identify any code deficiency for a MSLB simulation, especially for DVI-adapted plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synthetic Heat Transfer Fluids as Thermal Energy Storage Media for Existing NPPs

This paper provides a conceptual presentation on the integration of existing nuclear power plants with technically robust thermal energy storage solution. Although a more detailed analysis with entire condensate and feed water system integrated to the energy storage solution is required for more accurate analysis, for the conceptual presentation a simpler approach based on energy density and exergy analysis is adopted. Therminol and Dowtherm are commercially available robust technological solutions for this purpose and operate in the temperature range compatible with the existing PWRs. The analysis shows that exergy recovery efficiency is close to 95%, i.e. equal to efficiency proposed using molten salts. The energy density values for these HTFs in this operating range are not expected to create practical challenges and geometrical requirements can be met within the existing nuclear power plants. The energy storage costs with these off the shelf materials already being produced in very large quantities via well established processes are much lower than the projected costs of futuristic grid scale battery solutions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of Industry Task Orders Completed by the U.S. Department of Energy, Office of Nuclear Energy's Nuclear Fuel Storage and Transportation Planning Project

The Administration released its Strategy for the Management and Disposal of Used Nuclear Fuel and High- Level Radioactive Waste in January 2013. The Strategy includes a phased, adaptive, and consent-based approach to siting, and implementing a comprehensive management and disposal system. These plans include activities to establish one or more ISFs using consent-based siting and to prepare for large-scale transport of spent nuclear fuel (SNF). Nuclear Fuels Storage and Transportation Planning Project (NFST) completed the following three Task Orders, using industry Advisory and Assistance Contracts related interim storage and transportation. These design concepts provide important information to the waste management systems analysis regarding throughput capacities, operational considerations, and cost estimates. - Generic Design Alternatives for Dry Storage of Used Nuclear Fuel- Chicago Bridge and Iron (CBandI) developed and documented generic design alternatives for receipt and storage of SNF and greater-than-class-C (GTCC) waste contained in dual-purpose canisters. - Generic Design for Small Size Standard Transportation, Aging, and Disposal Canister System- EnergySolutions developed a generic design of a small capacity (4 PWR/9 BWR) Standard Transportation, Aging, and Disposal (STAD) canister. - Operational Requirements for Standardized Dry Fuel Canister Systems- EnergySolutions developed solutions to address operational impacts of using a standardized canister at utility sites with a smaller capacity than conventional, dual-purpose canisters (DPC). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Analyses of Passive Containment Cooling System for a Concrete Type Containment

The containment of nuclear power plants is the final barrier to keep the radioactive materials from uncontrolled release to the environment. To keep the containment integrity, pressure and temperature must be controlled by the spray system which relies on active components for PWRs with a concrete containment. To achieve a passive means to keep the containment integrity, therefore, cooling should be achieved by forming a natural circulation loop between internal cooling devices connected to an external heat sink. A system like this is often called Passive Containment Cooling System (PCCS). In the early phase of APR-1400 development, this concept was studied and VVER-1200 is also known to adopt the PCCS. The PCCS consists of a cooling device installed at the inside of the containment which is a tube-bank type heat exchanger where cooling occurs at the exterior of the tubes and a heat sink which is called Passive Containment Cooling Tank (PCCT) located at the outside of the containment on the top of the auxiliary building. In this paper, we introduce performance analysis results, utilizing the GOTHIC computer code. The PCCS performance analysis model was developed for APR-1400 which has a thermal power of 4000 MW and considers PCCS as an option to improve its safety characteristics. The PCCS which is considered in this paper is to cope with both Design Basis and Severe Accidents, considering SBO conditions. The pressure and temperature transients due to the Loss of Coolant Accident (LOCA) were analyzed with and without PCCS together with a normal case using the spray system. And, in particular, limitations of the PCCS in regard to mission time will be discussed. Through this study, it was found that the PCCS being considered as an option to improve the safety of APR-1400 can have almost same capability to control the containment pressure for LBLOCA as the containment spray system does. Although it would depends on the heat removal capacity of a given design such as the size of the heat transfer area, the PCCS could even replace the containment spray system. However, the PCCS may lose its capability after 24 hours as its temperature reaches that of the containment atmosphere. To extend the mission time of PCCS, either cooling or supplementary cold water needs to be provided to the external heat sink of PCCS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nitride Fuel Potential for Power Uprates

This work presents the methodology and current results for design analysis of grid supported pressurized water reactor cores using uranium nitride (UN) fuel in square arrays. Uranium nitride has a higher theoretical density and higher thermal conductivity than uranium oxide, allowing for lower fuel temperatures, longer cycle length and higher power densities with similar enrichment. In order to avoid the UN and high temperature water reaction, silicon carbide cladding has been proposed in place of Zircaloy cladding. The analysis aims at finding the maximum thermal power over a range of bundle geometries (rod diameter and pitch). The same methodology is applied to the design of UO{sub 2} oxide fueled cores to provide a fair comparison of the achievable power rating between the two fuel types. Steady-state limits are considered, including fuel bundle pressure drop, minimum departure from nucleate boiling ratio (MDNBR), fuel temperature, fuel rod vibrations and pin fretting and sliding wear. Transients such as loss of flow and overpower accident will be considered. A steady state analysis was undertaken to determine the maximum achievable power that can be sustained by square array fuel assemblies loaded with nitride and oxide fuels with same or better safety performances as the reference design. Steady-state design limits were applied including MDNBR, fuel bundle pressure drop, fuel temperature, cumulative sliding and fretting wear. The major conclusions of this study are as follows: 1) It is possible to achieve significant power increase for UN and UO{sub 2} compared to the reference core power output of 3400 MWth with smaller but more numerous rods and higher pitch over diameter ratios. A power uprate of 25% can be reached according to the VIPRE-MATLAB interface for full core analysis with the same number of spacer grids, and 32% according to the new MATLAB script for single hot channel analysis, with five more spacer grids. For this latter core, a higher enrichment would be required. 2) The nitride fuel temperature constraint from dissociation doesn't influence steady state performances as other design constraints such as MDNBR and pressure loss are more restrictive. The oxide fuel temperature constraint from fission gas release is reached in part of the study domain, but not in the region that allows for possible uprates. 3) As a result, the thermal hydraulic performance of UN and UO{sub 2} are similar. Differences in possible power uprates will arise from fretting and sliding wear. Wear depends of the time spent by the fuel in the core, which depends on burnup and heavy metal inventory. UN being denser, it can allow for power uprates or increased cycle length. There is a trade off between power uprates and cycle length with regards to fuel pin wear. Reducing fuel pin wear by reducing cycle length can allow for higher thermal power. This affects the plants' economics as well. This work will be completed by a transient analysis using CASMO4E, SIMULATE3 and SIMULATE3k to model the neutronics of a nitride fueled core. The transient performances will be used to determine the maximum power uprates while performing as well or better during transients as the reference design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

APR1400 In-Core Instrumentation Penetration Failure by Zirconia Melt

Light water reactors have many penetrations at the reactor vessel lower head which are called ICI (in-core instrumentation tubes), ICM-GT (in-core monitoring guide tubes), CRGT (control rod guide tubes) and drain tubes. For Korean PWRs (pressurized water reactors), there are dozens of bottom-up type ICI penetration tubes (45 for OPR1000 and 61 for APR1400). For the typical BWRs (boiling water reactors), hundreds of penetrations are positioned at the reactor vessel lower head due to the structural complexity at the reactor upper head. These penetrations are regarded as the most vulnerable structures during a severe accident as they could be failed by high temperature of melt (or debris) and its decay heat. That is, tube rupture and/or tube ejection could occur because there exist an empty hole inside the penetration tube which can be a melt flow path, and they are attached to the inside of the reactor vessel by a partial weld with a gap between the tubes and reactor vessel. Therefore, the research on the penetration failure is of importance, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. This paper focuses on the experimental investigation on the tube ejection failure for the APR1400 ICI penetration. The tube ejection experiments were performed as it was exposed to high temperature of zirconia melt and high pressure. The tube ejection failure experiments were performed for the APR1400 in-core instrumentation penetration nozzle. Zirconia melt was used as a simulant of molten corium and interacted with the penetration specimen. The specimen was pressurized up to 2.6 bar during the interaction with melt to induce the tube ejection. The penetration weld was heated up to its melting temperature, and the penetration tube and weld above the reactor vessel surface were eroded severely by the melt. However, even though it was estimated that the weld failure occurred and the reactor vessel with stainless steel cladding was ablated severely by the melt, the tube ejection did not take place, and consequently the integrity for the APR1400 ICI penetration was confirmed in the present experimental conditions. The goal of this research is to improve the penetrations failure models in MAAP5 codes based on the experimental data. To achieve this goal, it is necessary to increase the heat flux and pressure acting on the penetration tube to find the conditions for the tube ejection failure. Moreover, the penetration failure experiments will be performed by delivering melt into the penetration specimen to simulate the melt relocation process in a real severe accident situation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the Modeling of Wall Heat Flux Partitioning in Subcooled Flow Boiling

Accurate prediction of void distribution in reactor coolant channels at subcooled boiling conditions is an important factor in the analysis of the operating conditions of both pressurized water reactors (PWRs) and boiling water reactors (BWRs). Its importance arises from purely thermal-hydraulic considerations (thermal limits, CRUD formation, etc.) and the impact of void reactivity feedback on core neutronics. A mechanistic multidimensional model of subcooled boiling was originally developed by Kurul and Podowski. Whereas this model has been implemented in several commercial CFD codes and successfully used in computer simulations of flow and phase distributions in the coolant channels of light water reactor, additional new modeling aspects of forced-convection subcooled boiling heat transfer have been investigated in recent studies. The purpose of this paper is to formulate a modified model of wall heat flux partitioning, which allows for capturing and quantifying the effect of simultaneous evaporation and condensation at the heated wall on the net evaporation rate and wall temperature. The new model has been implemented in the NPHASE-CMFD code, numerically tested and validated against experimental data. A mechanistic wall heat flux partitioning model for subcooled flow boiling has been presented. This model has been combined with extensively tested models of interfacial mass, momentum and energy transfer terms. It turns out that the model predictions of the wall temperature and void fraction are in good agreement with the experimental data of reference. Future work will focus on the continuation of model validation against experimental data, and on extending its scope to include the phenomena governing departure from nucleate boiling. (authors)

42 ENGINEERING↗

The MELCOR Analysis of Chinshan Nuclear Power Plant Spent Fuel Pool for Fukushima-like Accident

The safety analysis of the nuclear power plant (NPP) is very important work in the NPP safety. Especially after the Fukushima NPP accident occurred, the importance of NPP safety analysis has been raised and there is more concern for the safety of NPPs in Taiwan. Because the earthquake and tsunami occurred, the cooling system of spent fuel pool failed and the safety issue of spent fuel pool generated in Japan's Fukushima NPP. Chinshan NPP is the first NPP in Taiwan which is BWR/4 plant and OLTP (Original Licensed Thermal Power) for each unit is 1775 MWt. Chinshan NPP finished SPU (stretch power uprate) and the operating power is 103.66% of the OLTP, which is 1840 MWt now. After Fukushima NPP accident occurred, in order to concern the safety of Chinshan NPP spent fuel pool, we performed the safety analysis of spent fuel pool by using MELCOR/SNAP which also assumed the cooling system of spent fuel pool failed. The geometry of Chinshan NPP spent fuel pool is 12.17 m x 7.87 m x 11.61 m and the initial condition is 60 deg. (water temperature) / 1.013 x 10{sup 5} Pa. And, the total power of the fuels is roughly 8.9 MWt initially. MELCOR is developed by Sandia National Laboratories. MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor NPPs, including containment response and leakage of activity to the environment. A broad spectrum of severe accident phenomena in both BWRs and PWRs is treated in MELCOR in a unified framework. These include thermalhydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. According to Dr. Carbajo's paper, MELCOR was used to perform the study of spent fuel pool of Fukushima Daiichi Unit 4. Niina E. Koenoenen used MELCOR to establish the spent fuel pool model of a Nordic BWR. The loss-of-pool-cooling accidents was simulated and analyzed by this model. The above studies indicate that MELCOR is capable of handling the simulation of the spent fuel pool. An increasing number of researchers are using MELCOR code to analyze test facilities and nuclear power plants. Jun Wang et al. used MELCOR to perform core degradation simulation and MELCOR results were compared with CORA experimental data. Through this work, they reviewed the performance of MELCOR COR package in detail. Tae Woon Kim et al. developed MELCOR model of APR1400 (an advanced pressurized water reactor). They used this model to perform the LBLOCA transient simulation and sensitivity study. Longze Li et al. established the MELCOR model of CPR1000 (a Chinese pressurized reactor 1000-MW power plant). The station blackout (SBO) with failure of the steam generator (SG) safety relief valve (SRV) transient was simulated and analyzed by this model. SNAP is a graphic user interface program that processes the inputs and outputs of MELCOR. In addition, there is an animation function in SNAP which can present the animation of analysis results. There are two main steps in this research. The first step was the establishment of Chinshan NPP spent fuel pool MELCOR/SNAP model. And the transient analysis of Chinshan NPP spent fuel pool MELCOR/SNAP model under the cooling system failure condition was performed. The next step was the comparison among the MELCOR, TRACE and CFD data. TRACE and CFD data were from INER reports. In addition, the animation model of Chinshan NPP spent fuel pool was presented by using the animation function of SNAP with MELCOR/SNAP analysis results. This study has developed MELCOR/SNAP model of Chinshan NPP spent fuel pool successfully. By using the above model, the safety analysis of the spent fuel pool was performed under the cooling system of spent fuel pool failed condition. The analysis results of MELCOR, TRACE and CFD were similar in this case. It indicated that there was a respectable accuracy in MELCOR/SNAP model. The analysis results depicted that the uncovered of the fuels occurred at 2.6 day and the metal-water reaction of fuels occurred roughly at 3.7 day after the cooling system failed. The above results indicated that the failure of cladding occurred after 3.7 day. This study's results can help to evaluate the safety issue of Chinshan NPP spent fuel pool. In addition, the cooling system and some mitigation measures of spent fuel pool is not simulated in the above model. However, we will do it in the future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress in L/ILW Management at Operating NPP in the USA - 19697

The volume of Low and Intermediate Level Waste (L/ILW) from commercial nuclear power plants (NPP) buried annually in the USA decreased dramatically over the last two decades of the last century. The reduction in disposal volume occurred for both dry active waste (DAW) and wet waste (e.g., resins, filters and sludges). Decreased disposal volume occurred at both Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs). The reduction in disposal volume occurred in stages. The major driver to reduce disposal volume in the commercial sector of the USA last century was increasing burial costs. The advent of bulk disposal facilities this century, lead to a reduction in burial costs for lower activity waste. The current drive to further reduce overall NPP operating costs to meet a deregulated electric market in the USA coupled with reduced disposal fees has removed the incentive for volume reduction and recycling. Waste minimization practices remain cost effective. This paper will review the stages of waste reduction and describe the current stage for NPP in the USA. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation and control of a passively cooled small modular reactor Samet - 142

This work regulates a small modular reactor (SMR) with traditional control methodologies and analyzes its response to typical disturbances. An analytical model for the passively cooled NuScale SMR is developed to represent the essential dynamics. The MATLAB/Simulink based model consists of reactor core, steam generator, pressurizer, hot leg riser and downcomer, and turbine representations. The point kinetics equations with a single combined neutron precursor group and the lumped parameter representations with single-phase natural circulation account for the neutronics and thermohydraulics in the reactor core. A lumped parameter, moving-boundary approach forms the basis of the nonlinear model adopted for the once-through helical-coil heat exchangers in which boundaries between regions of different fluid states (i.e., subcooled, boiling, and superheated) vary over time. A proportional-integral-derivative controller employing a sliding-average temperature strategy commonly used for pressurized water reactors is implemented. The responses of the SMR to two different disturbances are analyzed and discussed in detail. For the first scenario, a 5% step increase in the load is applied to the system, which results in a change in the steam valve opening. For comparison, two different simulations under this same disturbance are run: one including and one excluding the control systems. The second scenario tests the effectiveness of the control system to increase (or decrease) the reactor thermal power to a certain level within a desired time period. The simulation results show that important system variables are kept at the desired values by the proposed control strategy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power control system modification and simulation of CPR1000 - 181

Due to development of electric power system, the proportion of nuclear power and its needs for load follow operation have become large. Then there would be higher requirements to the power control ability of the nuclear power system. The axial power distribution may change a lot in the operation process and be affected by many factors. In particular, as the power change is performed within a load follow maneuver, several modifications occur in the core from a neutronic view point: the fuel and moderator temperature change, the xenon concentration and distribution are modified, the power distribution skewed axially, etc. These changes need to be adequately counterbalanced to keep both the core critical and the power distribution acceptable. The traditional approach in pressurized water reactors (PWRs) is compensating for the reactivity change due to the power variation by adjusting the soluble boron concentration and moving a limited number of control banks. However, dilution/boronation strategy becomes expensive for short time changes and leads to large volume of liquid effluent, so it is eager about a capability to perform load follow operation without changing soluble boron concentration. CPR1000, one of the main reactor types in China national development, is taken an example in this paper. It adopts a control method called Mode G, using G banks, N banks, R bank and soluble boron to perform the load follow control. According to the analysis of the physics and thermal principle, a two-node dynamic function model was built, putting the coupling coefficient and mutual influence into consideration. By the calculation of these transient parameter values which are acquired by the steady-state calculation of single channel, the core system model of CPR1000 is established. In order to carry out the load follow operation without the boron adjustment, named as BTP mode, the control banks were regrouped to control the average temperature by M banks and axial offset by AO bank. After that, the average temperature control system (M banks control system) and the axial offset control system (AO bank control system) are built. When the optimal control system is connected to the core model simulation platform, the BTP mode load follow operation of the modified CPR1000 is simulated in the end of the paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control strategies for coupling thermal energy storage systems with small modular reactors - 188

The contribution of intermittent (renewable) energy sources such as wind and solar continues to increase as renewables improve in both efficiency and price-point. However, the variability of renewables generates additional challenges for the electric grid in the form of rapidly varying electric loads. Proposed options for accommodating this load have included operating nuclear reactors in a load follow mode, or operating the reactor at or near steady state and bypassing steam directly to the condenser. Both of these strategies result in lost energy potential. In addition to lost energy potential, load follow operation can result in increased stress on the fuel and other mechanical components. A more attractive approach is to operate the reactor at or near steady state and bypass excess steam to a thermal energy storage system. The thermal energy can then be recovered, either for electric generation during periods of peak electric demand, or for use in ancillary applications such as desalination and hydrogen production. Sensible Heat Thermal Energy Storage is a mature technology currently used in solar energy systems. This research focuses on the design and coupling of such a system to Small Modular Reactors (SMRs), typical of Integral Pressurized Water Reactor (IPWR) designs currently under development. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emerging and existing sensing technologies for small modular reactors and advanced reactors - 191

The development of small modular reactors (SMRs) and Generation-IV advanced reactor designs represents a promising future for nuclear energy. These next-generation reactors can support new applications for nuclear energy like hydrogen production, industrial heat generation, and water desalination in addition to electricity generation. Furthermore, SMRs and advanced reactors enable load-following operations, offer improved passive safety features, support lengthened refueling cycles, and provide spent fuel management capabilities. To date, there are no SMRs operating or under construction in the United States, but commercial operation of the first integral Pressurized Water Reactor (iPWR) SMR is expected by the mid-2020's with Generation-IV advanced reactors to follow a decade or two later. To facilitate the development and deployment of SMRs and advanced reactors, key instrumentation and control (I and C) system challenges must be addressed and existing nuclear grade I and C sensors will need to be adapted or new sensors developed. For example, traditional measurement techniques and maintenance strategies used in the current generation of light water reactors (LWRs) will be challenged by the inherent design characteristics of the iPWR. For Generation-IV reactors, conventional I and C sensors will not withstand prolonged exposure to the harsh environmental conditions of advanced reactors (e.g. elevated temperatures, corrosive coolants, increased radiation). This paper discusses the challenges associated with making primary system process measurements in next-generation reactors and includes a summary of work performed to evaluate existing and emerging sensor technologies for these systems. As importantly, the paper presents the initial test results of a prototype temperature sensor developed by Analysis and Measurement Services Corporation (AMS) for use in SMRs and advanced reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Online monitoring of rod control systems in combustion engineering pressurized water reactors - 195

Current designs of Pressurized Water Reactors (PWRs) are equipped with control and shutdown rods that are inserted and withdrawn from the reactor core to control reactivity. In Combustion Engineering (CE) plants, these rods are moved using the Control Element Drive Mechanism (CEDM) and controlled by the CEDM Control System (CEDMCS). In the event of system failure, troubleshooting activities can have a substantial impact on plant resources. Furthermore, CEDM component failures have occurred without warning, which has led to increased costs for the plants. These issues, combined with the inherently complex design of the CEDMCS, create a need for an online diagnostics system that can improve system health monitoring, increase diagnostic capabilities, and decrease troubleshooting time. This paper describes an advanced analysis and diagnostics system that monitors the CEDMCS during plant operation and provides critical information to onsite personnel to help detect and prevent problems before they impact normal plant operation. This system uses existing CEDMCS test points to acquire data and needs no modifications to the CEDMCS for implementation. The online monitoring capabilities automatically collect data during normal operation and diagnose failure events, reduce troubleshooting time and provide plant personnel with valuable information which is not currently available. Additionally, the system has built-in features used to streamline routine surveillance testing, collect stationary and movement data on multiple rods simultaneously, automate analysis, and generate reports. This system was developed with input from industry CEDMCS engineers at existing commercial facilities and has been deployed in multiple operating nuclear plants. The system has demonstrated itself to be a valuable tool for CEDMCS health monitoring, not only in reducing required man-power for routine system testing, but also in detected impending coil faults and allowing plant engineers to mitigate system component failures to prevent impending plant shut downs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Risk assessment of safety-critical data communication in digital safety feature control system - 205

As one of the safety-critical systems in Advanced Power Reactor-1400 (APR-1400) nuclear power plant (NPP), the Engineered Safety Feature-Component Control System (ESF-CCS) employs safety data link and network communication for transmitting safety component actuation to effectively facilitate various safety-critical field controllers. However, data communication failure risk in the ESF-CCS has yet to be fully quantified, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In this study, a fault tree model was developed to assess the data link and data network failure-induced unavailability of a safety-critical system function used to generate an automated control signal for actuating design basis accident mitigation equipment. Especially, the risk of data communication failure in a digital safety feature control system was analyzed in consideration of interconnection between safety-critical controllers and the fault-tolerant algorithm implemented in the network configuration. Based on the developed fault tree model, case studies were performed to quantitatively assess the unavailability of ESF-CCS signal generation due to safety data link and network failure and their risk effect on safety signal generation unavailability. This study is expected to provide risk information on the safety-critical data communication in a digitalized NPP instrumentation and control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancing power plant safety through simulated cyber events - 341

There are gaps in understanding how a cyber-attack would manifest itself within power plants and what these events would look like within the control room from an operator's perspective. This is especially true for nuclear power plants where safety has much broader consequences than nonnuclear plants. The operating and emergency procedures that operators currently use are likely inadequate for targeted cyber-attacks. This research focuses on understanding how a cyber event would affect the operation of the plant, how an operator would perceive the event, and if the operator's actions would keep the plant in a safe condition. This research is part of Sandia's Laboratory Directed Research and Development program where a nuclear power plant cyber model of the control system digital architecture is coupled with a generic pressurized water reactor plant training simulator. Cyber event scenarios will be performed on the coupled system with plant operators. The scenarios simulate plant conditions that may exist during a cyber-attack, component failure, or insider sabotage, and provide an understanding of the displayed information and the actual plant conditions. These scenarios will determine if plant operators can 1) recognize that they are under cyber-attack and 2) take appropriate actions to keep the plant safe. This will also provide the opportunity to assess the operator cognitive workload during such events and identify where improvements might be made. Experiments with nuclear power plant operators will be carried out over FY 2018 and results of the research are expected by the end of FY 2018. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary analysis of effect of Vanadium Self-Powered Neutron Detectors on AP1000 reactor core physical parameters - 360

For the AP1000 reactor, the Vanadium Self-Powered Neutron Detectors are installed in the instrumentation thimbles of the fuel assembly. The (n,? ) reaction of Vanadium SPNDs will impact on the neutron spectrum of the location, and finally impact on the reactor core physical parameters. But, this effect is not considered for the AP1000 reactor Nuclear Design. So, it is necessary to analyze the effect of the presence of Vanadium SPNDs on the AP1000 reactor core physical parameters. CASMO5 is used to calculate physical parameters of four typical assemblies of AP1000 reactor, and SIMULATE5 is used to calculate physical parameters of the initial cycle. The results show that the maximum absolute deviations of K-infinite, pin power, thermal flux for the assemblies are 181 pcm, 6.3% and 20.1%, separately. The maximum absolute deviations of critical boron concentration, heat flux hot channel factor, nuclear enthalpy rise hot channel factor, axial offset, quadrant power tilt ratio and axial power distribution of the initial cycle are 5 ppm, 0.7%, 0.5%, 0.1%,0.09% and 0.19%,separately. So, the presence of Vanadium SPNDs has a significant impact on the power distribution of pin cells around the instrumentation thimble and the thermal flux in the location of instrumentation thimble, but doesn't affect core physical parameters of the initial cycle very much. As is shown, it is very important to accurately consider the effect of presence of Vanadium SPNDs when calculating the Vanadium SPNDs current response. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗