Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

“Edgeboost”: A Novel Technique to Extend the Ablation Zone Lateral to a Two-Probe Bipolar Radiofrequency Device

BackgroundThe dual-electrode bipolar-RFA (B-RFA) is increasingly used to ablate large liver tumours (3–7 cm). However, the challenging aspect of B-RFA is the placement of the two electrodes around the tumour. Realignment often requires the electrodes to be extracted and reinserted.AimThe aim of this study is to examine “Edgeboost”, a novel technique to increase the lateral ablation dimension without requiring any realignment of the electrodes.Methods and MaterialsAn egg-white model and an ex vivo calf liver model were used compare the standard bipolar mode ablation to Edgeboost-1 (reaching full impedance in bipolar mode initially, then cycling in unipolar mode between left and right probes) and Edgeboost-2 (similar to Edgeboost-1 but not reaching full impedance initially in bipolar mode in order to minimize charring and, thus, to increase total ablation time).ResultsA significantly larger outer lateral ablation dimension to the probe was achieved with Edgeboost-1 compared to the standard method in the liver model (1.14 cm, SD: 0.16 vs. 0.44 cm, SD: 0.24, p = 0.04). Edgeboost-2 achieved the largest outer lateral ablation dimension of 1.75 cm (SD: 0.35). A similar association was seen in the egg model. Edgeboost-2 almost doubled the mass ablated with standard bipolar alone (mass ratio: 1:1.94 in egg white and 1:1.84 in liver).ConclusionThis study demonstrates that the novel “Edgeboost” technique can increase the outer lateral ablation dimension without requiring the two inserted electrodes to be reinserted. This would be beneficial for interventionists who use the dual B-RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quaternary Ammonium Polyamidoamine Dendrimer Modified Quantum Dots as Fluorescent Probes for p-Fluorophenoxyacetic Acid Detection in Aqueous Solution

The wide use of pesticide p-fluorophenoxyacetic acid has caused the serious environmental contaminant. A novel fluorescent probe for sensitive detection of p-fluorophenoxyacetic acid in aqueous solutions based on 3.0G quaternary ammonium polyamidoamine (PAMAM) dendrimer modified quantum dots (QDs) (PAMAM@QDs) was reported. Through the solvent-evaporation method, quaternary ammonium PAMAM was employed to modify the QDs. Poloxamer 188 was used to improve the solubility and stability. The resultant PAMAM@QDs dispersed well in water. Fluorescence (FL) spectroscopic study showed that the FL intensity of the PAMAM@QDs was enhanced in the presence of p-fluorophenoxyacetic acid. Under optimal conditions, the enhanced FL intensity as a function of concentration matched very well in the range of 1 ~ 200 µg/mL of p-fluorophenoxyacetic acid, while the lower limits of detection were found to be 0.16 µg/mL. These results show that PAMAM@QDs is a promising luminescent probe for the detection of pesticides.

74 ATOMIC AND MOLECULAR PHYSICS↗

Review on Recent Advances in Metal Ions Sensing Using Different Fluorescent Probes

Fluorescence probes serves as unique detection methods for its simplicity and low detection limit (LOD) and especially bioimaging ability. Research on the probes has already sprouted during the last decade with the help of its molecular recognition properties. This review spotlights recent progress in sensing and bioimaging biologically, environmentally and industrially important metal ions e.g. Zn{sup 2+}, Cu{sup 2+}, Hg{sup 2+}, Ag{sup +} etc. using suitable fluorescent chemosensors including carbon quantum dots (CQD).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Dual-Target Fluorescent Probe with Response-Time Dependent Selectivity for Cd{sup 2+} and Cu{sup 2+}

A novel fluorescent probe (NT) was developed by merging 2-hydrazinylbenzothiazole with 2-hydroxy-1-naphthaldehyde for the detection of Cd{sup 2+} and Cu{sup 2+}. The probe alone is almost nonfluorescent due to the isomerization of C=N in the excited state. The addition of Cd{sup 2+} can cause an immediate strong green fluorescence owing to the suppression of C=N isomerization by Cd{sup 2+}-coordination. Furthermore, NT gives a delayed turn-on fluorescence response to Cu{sup 2+} although it is a vigorous fluorescence quencher, which was thanks to the inhibition of the electron transfer between excited fluorophore and paramagnetic Cu{sup 2+} by sulfur donor. Based on fluorescence spectra and ESI-MS analysis, the binding modes between NT and Cd{sup 2+}/Cu{sup 2+} were proposed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probe-Substrate Distance Control in Desorption Electrospray Ionization

We introduce probe-substrate distance (D{sub ps})-control to desorption electrospray ionization (DESI) and report a systematic investigation of key experimental parameters. Examination of voltage, flow rate, and nebulizing gas pressure suggests as D{sub ps} decreases, the distance-dependent spray current increases, until a critical point. At the critical point the relationship inverts, and the spray current decreases as the probe moves closer to the surface due to constriction of solution flow by the nebulizing gas. D{sub ps} control was used to explore the use of spray current as a signal for feedback positioning, while mass spectrometry imaging was performed simultaneously. Further development of this technique is expected to find application in study of structure-function relationships for clinical diagnostics, biological investigation, and materials characterization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

Energy-Dispersive X-ray Spectroscopy and Atom-probe Tomography Data Quantifying Component-Ratios of Multicomponent Nano-Precipitates in Ion-Irradiated Ceria

Samples of ~1 µm films of CeO2 doped with 2 wt% Mo, 1.5 wt% Ru, 0.75 wt% Pd, 0.5 wt% Re and 0.25 wt% Rh grown with pulsed laser deposition were irradiated with I2+ ions (610°C and 730°C, 1016 and 5×1016 I2+/cm2). For selected samples post-irradiation heat treatment was conducted (900°C, 1100°C). The specimens were sectioned with focussed ion beam milling and characterized in a transmission electron microscope with energy dispesive x-ray spectroscopy, and with atom-probe tomography. Energy dispersive x-ray spectroscopy was used to obtain elemental maps showing the distribution of dopants in the specimen after exposure. Some of these maps are discussed in detail in our companion article “Formation of multicomponent alloy particles in doped ceria under I2+ ion irradiation and thermal annealing” in the Journal of Nuclear Materials [REF]. Advanced computational analysis could be used to more accurately quantify local compositions. Data is provided for additional regions of interest and one additional irradiation condition. The doped Ceria film that was heat treated at 1100 °C delaminated from the substrate in most places. Samples were extracted from the underside of a delaminated piece and analyzed with atom-probe tomography. The resulting data show Ceria and a Mo-rich particle and demonstrate that this approach is feasable in principle to study local compositions in a sample exposed to such extreme conditions.

multicomponent alloys, epsilon phase, EDS, atom pr↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

Analysis of thermal response of new diagnostic probe in TCV

Thermal response of the new multi-purpose diagnostic probe inside the TCV (Tokamak à Configuration Variable) tokamak is studied. The New Probe Head (NPH) was constructed at the University of Innsbruck and developed in collaboration with various European laboratories within EUROfusion program. The NPH can be used in different MST devices by applying corresponding adapters. Its design, followed by the prototype, has to go through a number of tests (numerical and experimental), before it can be used in the tokamak environment, where it has to withstand repeated exposure to the Scrape-Off-Layer (SOL) plasma. Presented numerical analyses of the NPH thermal response inside the TCV tokamak are performed by the Jožef Stefan Institute.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterisation of nano-scale precipitates in BOR60 irradiated T91 steel using atom probe tomography

Atom probe tomography has characterised the microstructural changes in T91 steel after BOR60 reactor irradiation at five temperatures between 376 °C and 524 °C to doses between 14.6 dpa and 35.1 dpa. Irradiation-induced precipitation and segregation to carbide/matrix interface induced by neutron irradiation has been characterised. Atom probe tomography characterisation shows that Mn, Ni, Si -rich (MNS-rich) clusters form in T91 steel irradiated in BOR60 reactor at temperatures between 376 °C and 415 °C, which is not observed at higher temperatures 460 °C and 524 °C. Additionally, the number density, volume fraction and composition of MNS-rich clusters have been characterised. Ni, Mn, Si and P is found to segregate at carbide matrix interface after irradiation at lower temperature and only P segregation is observed at 524 °C.

36 MATERIALS SCIENCE↗

Direct comparison of Fe-Cr unmixing characterization by atom probe tomography and small angle scattering

The fine microstructure obtained by unmixing of a solid solution either by classical precipitation or spinodal decomposition is often characterized either by small angle scattering or atom probe tomography. This article shows that a common data analysis framework can be used to analyze data obtained from these two techniques. An example of the application of this common analysis is given for characterization of the unmixing of the Fe-Cr matrix of a 15-5 PH stainless steel during long-term ageing at 350 °C and 400 °C. A direct comparison of the Cr composition fluctuations amplitudes and characteristic lengths obtained with both techniques is made showing a quantitative agreement for the fluctuation amplitudes. The origin of the discrepancy remaining for the characteristic lengths is discussed. - Highlights: •Common analysis framework for atom probe tomography and small angle scattering •Comparison of same microstructural characteristics obtained using both techniques •Good correlation of Cr composition fluctuations amplitudes from both techniques •Good correlation of Cr composition fluctuations amplitudes with classic V parameter.

36 MATERIALS SCIENCE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing nanoscale precipitation in a titanium alloy by laser-assisted atom probe tomography

Highlights: • Atom-probe tomography was performed on Ti-5Al-5Mo-5V-3Cr wt% after quenching and 300 °C aging. • Isothermal ω phase was identified as Ti-rich and solute depleted after 1 h of aging. • The ω precipitate/matrix interface is O enriched. This may facilitate α formation. • High laser-pulse energies increase the probability of complex ion formation, complicating analysis. • Discrepancies between data from the LEAP 5000 XS and LEAP 4000X Si are discussed. - Abstract: Atom-probe tomography was performed on the metastable β-Ti alloy, Ti-5Al-5Mo-5V-3Cr wt% (Ti-5553), aged at 300 °C for 0 to 8 h, to precipitate the embrittling isothermal ω phase. Accurate precipitate quantification requires monitoring and controlling suitable charge-state ratios in the mass spectrum, which in turn are closely related to the laser pulse energy used. High ultraviolet laser pulse energies result in significant complex molecular ion formation during field-evaporation, causing mass spectral peak overlaps that inherently complicate data analyses. Observations and accurate quantification of the ω-phase under such conditions are difficult. The effect is minimized or eliminated by using smaller laser pulse energies. With a small laser pulse energy, Ti-rich and solute depleted precipitates of the isothermal ω phase with an oxygen enriched interface are observed as early as after 1 h aging time utilizing the LEAP 5000X S (77% detection efficiency). We note that these precipitates were not detected below a 2 h aging time with the LEAP 4000X Si (58% detection efficiency). The results are compared to the archival literature. The Al concentration in the matrix/precipitate interfacial region increases during aging. Nucleation of the α-phase at longer aging times may be facilitated by the O and Al enrichment at the matrix/precipitate interface (both strong α-stabilisers). The kinetics and compositional trajectory of the ω-phase with aging time are quantified, facilitating direct correlation of the APT data to previously published mechanical testing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Validation of an alloy design strategy for stable Fe–Cr–Al–Nb-X ferritic alloys using electron microscopy and atom probe tomography

The Fe–Cr–Al–Nb ferritic alloys strengthened by A₂B Laves phases, with superior oxidation and corrosion resistance, are being considered for high temperature operation within fossil-fired steam power plants to increase process efficiency and reduce CO₂ emissions. In this paper, new sets of alloys based on Fe–30Cr–3Al–1Nb (in weight percent) were designed with (i) a high microstructural stability of Laves phase precipitates in a BCC-Fe matrix and (ii) reduced precipitate free zones along the grain boundaries, targeting an operating temperature of 700 °C. Two alloys with titanium or tungsten additions were down-selected through thermodynamic calculations with a design strategy to maximize the amount of Laves phase at 700 °C and lower the BCC solvus temperature. To validate this design strategy, the candidate alloys were cast, heat treated and aged at 700 °C, and the resulting microstructure was characterized using scanning electron microscopy and atom probe tomography. The alloys with titanium addition (1 wt%) showed monotonic precipitate coarsening. On the other hand, the alloys with tungsten addition (6 wt%) showed a reduced coarsening rate of Laves phase precipitates in the matrix up to 1008 h aging, whereas an acceleration of the precipitate coarsening after that. Atom probe tomography of this alloy revealed the formation of a core-shell precipitate structure with a Nb/Si rich core and W-rich shell, while the alloy with Ti-addition did not show the core-shell structure. The detailed characterization results revealed that the core-shell structure was strongly correlated with the observed two-step coarsening mode in the tungsten containing alloy.

36 MATERIALS SCIENCE↗

Electromagnetic & Weak Probes: Experimental Overview

Electromagnetic and electroweak probes are the most versatile probes in the study of heavy-ion collisions. Produced at every stage in the evolution of QCD matter, its messengers are practically inert to the strongly interacting medium they travel through. In this contribution, I will discuss a selection of new results from experiments at the LHC, RHIC, and SIS facilities, spanning almost four orders of magnitude in beam energy. Finally, I will conclude with a brief overview of the experimental landscape in the near future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale microstructure and chemistry of transparent gahnite glass-ceramics revealed by atom probe tomography

The nanoscale microstructure and chemistry of a transparent gahnite glass-ceramic and its precursor glass were investigated using atom probe tomography, transmission electron microscopy, and nuclear magnetic resonance spectroscopy. In the annealed precursor glass, statistically significant ZrO clustering was observed along with Si depletion within 2 nm of the ZrO clusters. This clustering is expected to be the first step in the nucleation and crystallization of the nucleating agent, ZrO 2 . In the glass-ceramic, gahnite (ZnAl 2 O 4 ) crystallites were found to exist in proximal locations to ZrO 2 and not in a core-shell arrangement. The residual glass composition was directly measured by atom probe, showing higher concentrations of Al, Zn, and Zr than previously expected. At the interfaces between the crystallites and residual glass, no enrichment or depletion zones were found. Our findings provide answers to outstanding questions surrounding the nucleation and elemental partitioning, microstructure, and the residual glass composition of transparent gahnite glass-ceramics.

36 MATERIALS SCIENCE↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗