At least 1,423 records · Page 79

The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n =1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n =1.030, ~8 for n =1.020, ~10 for n =1.015, and ~5.5 for n =1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast hadronic calorimetry

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations with respect to the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 2 ns providing opportunity for ultra-fast calorimetry. As a result, simulation results for an “ideal” calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on radiation tolerance of diamond detectors

In sight of the luminosity increase of the High Luminosity-LHC (HL-LHC), most experiments at the CERN Large Hadron Collider (LHC) are planning upgrades for their innermost layers in the next 5–10 years. These upgrades will require more radiation tolerant technologies than exist today. Usage of Chemical Vapor Deposition (CVD) diamond as detector material is one of the potentially interesting technologies for the upgrade. CVD diamond has been used extensively in the beam condition monitors of BaBar, Belle, CDF and all LHC experiments. Measurements of the radiation tolerance of the highest quality polycrystalline CVD material for a range of proton energies, pions and neutrons obtained with this material are presented. In addition, new results on the evolution of various semiconductor parameters as a function of the dose rate are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV 2 and 18 × 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A gaseous RICH detector for SiD or ILD

This paper describes a preliminary study of a gaseous Ring Imaging Cherenkov (RICH) system capable of discriminating between kaons and pions at high momenta — up to 50 GeV/c — and thus enhancing particle identification at future colliders. The system possesses a compact design, facilitating easy integration into existing detector concepts. Here, a study of the key contributions to the Cherenkov angle resolution is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observable consequences of event-by-event fluctuations of HBT radii

We explore the effects of event-by-event fluctuations of Hanbury Brown–Twiss (HBT) radii and show how they can be observed experimentally. The relation of measured HBT radii extracted from ensemble-averaged correlation functions to the mean of their event-by-event probability distribution is clarified. Here, we propose a method to experimentally determine the mean and variance of this distribution and test it on an ensemble of fluctuating events generated with the viscous hydrodynamic code VISH2+1. Using the same code, the sensitivity of the mean and variance of the HBT radii to the specific QGP shear viscosity $\eta$/s is studied. We report sensitivity of the mean pion HBT radii and their variances to the temperature dependence of \eta/s near the quark-hadron transition at a level similar (10-20%) to that which was previously observed for elliptic and quadrangular flow of charged hadrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pre-equilibrium dynamics and heavy-ion observables

To bracket the importance of the pre-equilibrium stage on relativistic heavy-ion collision observables, we compare simulations where it is modeled by either free-streaming partons or fluid dynamics. These cases implement the assumptions of extremely weak vs. extremely strong coupling in the initial collision stage. Accounting for flow generated in the pre-equilibrium stage, we study the sensitivity of radial, elliptic and triangular flow on the switching time when the hydrodynamic description becomes valid. Using the hybrid code iEBE-VISHNU [1] we perform a multi-parameter search, constrained by particle ratios, integrated elliptic and triangular charged hadron flow, the mean transverse momenta of pions, kaons and protons, and the second moment of the proton transverse momentum spectrum, to identify optimized values for the switching time \tau_s from pre-equilibrium to hydrodynamics, the specific shear viscosity eta/s, the normalization factor of the temperature-dependent specific bulk viscosity (zeta/s)(T), and the switching temperature T_sw from viscous hydrodynamics to the hadron cascade UrQMD. With the optimized parameters, we predict and compare with experiment the p_T -distributions of pi, K, p, Lambda, Xi and Omega yields and their elliptic flow coefficients, focusing specifically on the mass-ordering of the elliptic flow for protons and Lambda hyperons which is incorrectly described by VISHNU without pre-equilibrium flow.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Jet Measurements with Neutral and Di-jet Triggers in Central Au + Au Collisions at s N N = 200 GeV with STAR

We present two measurements related to jet production in p+p and central Au+Au collisions at $\sqrt{s}$NN=200 GeV. Firstly, a study of semi-inclusive charged recoil jets coincident with high-pT direct-photon and neutral pions, and secondly, the hadron correlations with respect to reconstructed di-jet triggers. Indication of medium effects is observed by comparing γ+jet and π 0 +jet measurements. In conclusion, the di-jet+hadron study shows signs that the medium-induced modifications of an imbalanced set of di-jets with “hard cores” primarily affect the recoil jet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗