Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Hot spot generation in energetic materials created by long-wavelength infrared radiation

Hot spots produced by long-wavelength infrared (LWIR) radiation in an energetic material, crystalline RDX (1,3,5-trinitroperhydro-1,3,5-triazine), were studied by thermal-imaging microscopy. The LWIR source was a CO{sub 2} laser operating in the 28-30 THz range. Hot spot generation was studied using relatively low intensity (∼100 W cm{sup −2}), long-duration (450 ms) LWIR pulses. The hot spots could be produced repeatedly in individual RDX crystals, to investigate the fundamental mechanisms of hot spot generation by LWIR, since the peak hot-spot temperatures were kept to ∼30 K above ambient. Hot spots were generated preferentially beneath RDX crystal planes making oblique angles with the LWIR beam. Surprisingly, hot spots were more prominent when the LWIR wavelength was tuned to be weakly absorbed (absorption depth ∼30 μm) than when the LWIR wavelength was strongly absorbed (absorption depth ∼5 μm). This unexpected effect was explained using a model that accounts for LWIR refraction and RDX thermal conduction. The weakly absorbed LWIR is slightly focused underneath the oblique crystal planes, and it penetrates the RDX crystals more deeply, increasing the likelihood of irradiating RDX defect inclusions that are able to strongly absorb or internally focus the LWIR beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of the low order rational q surfaces on the pellet deposition profile

Pellet injection is planned to be the main fuelling method on ITER. The high temperature of the plasma during a fusion burn will limit the penetration of the pellet to the outer third of the minor radius. This limited penetration is expected to be compensated by a polarization drift, which will deposit the particles deeper in the plasma for the pellets injected from the high field side. In order to evaluate the expected depth of the fuelling on ITER, a good understanding of this drift effect is important. Experimental data acquired on the DIII-D (USA) and Tore Supra (France) tokamaks show that the polarization drift is influenced by the low order rational q surfaces. These surfaces appear to attenuate the polarization mechanism as the drifting particles cross them. In this paper, a correlation between the maximum of the pellet mass deposition profile and the positions of the q = 2 and q = 3 surfaces on DIII-D and Tore Supra is shown for high field side and low field side injection. A model is proposed to explain this effect and compared with the experimental results. To conclude, the possible consequences of this phenomenon on the fuelling in ITER are described.

Commaux, Nicolas JC↗

SU-E-T-523: On the Radiobiological Impact of Lateral Scatter in Proton Beams

Introduction: In proton therapy, justified concern has been voiced with respect to an increased efficiency in cell kill at the distal end of the Bragg peak. This coupled with range uncertainty is a counter indication to use the Bragg peak to define the border of a treated volume with a critical organ. An alternative is to use the lateral edge of the proton beam, obtaining more robust plans. We investigate the spectral and biological effects of the lateral scatter . Methods: A general purpose Monte Carlo simulation engine (MCNPX 2.7c) installed on a Scientific Linux cluster, calculated the dose deposition spectrum of protons, knock on electrons and generated neutrons for a proton beam with maximal kinetic energy of 200MeV. Around the beam at different positions in the beam direction the spectrum is calculated in concentric rings of thickness 1cm. The deposited dose is converted to a double strand break map using an analytical expression.based on micro dosimetric calculations using a phenomenological Monte Carlo code (MCDS). A strict version of RBE is defined as the ratio of generation of double strand breaks in the different modalities. To generate the reference a Varian linac was modelled in MCNPX and the generated electron dose deposition spectrum was used . Results: On a pristine point source 200MeV beam the RBE before the Bragg peak was of the order of 1.1, increasing to 1.7 right behind the Bragg peak. When using a physically more realistic beam of 10cm diameter the effect was smaller. Both the lateral dose and RBE increased with increasing beam depth, generating a dose deposition with mixed biological effect. Conclusions: The dose deposition in proton beams need to be carefully examined because the biological effect will be different depending on the treatment geometry. Deeply penetrating proton beams generate more biologically effective lateral scatter.

07 ISOTOPE AND RADIATION SOURCES↗

High-frequency lunar teleseismic events

A small number of seismic signals, including some of the strongest observed to date, have been identified as representing a fourth principal category of natural lunar seismic events with characteristics distinct from those produced by normal meteoroid impacts, deep moonquakes, and thermal moonquakes. These signals are much richer in high frequencies than other events observed at comparable distances, and display relatively impulsive P- and S-wave beginnings, indicating negligible seismic-wave scattering near the source. Source depths of these events may range between 0 and perhaps 300 km. These and other characteristics could represent either (1) meteoroids impacting upon outcrops of competent lunar crystal rock, (2) rare impacting objects that penetrate to competent rock below a scattering zone, or (3) shallow tectonic moonquakes.

Nakamura, Y.↗

Completion Report for Well ER-20-11, Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-20-11 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Management Operations Underground Test Area (UGTA) Activity at the Nevada National Security Site (formerly Nevada Test Site), Nye County, Nevada. The well was drilled in September 2012 as part of the Central and Western Pahute Mesa Corrective Action Unit Phase II drilling program. Well ER-20-11 was constructed to further investigate the nature and extent of radionuclide-contaminated groundwater encountered in two nearby UGTA wells, to help define hydraulic and transport parameters for the contaminated Benham aquifer, and to provide data for the UGTA hydrostratigraphic framework model. The 44.5-centimeter (cm) surface hole was drilled to a depth of 520.0 meters (m) and cased with 34.0-cm casing to 511.5 m. The hole diameter was then decreased to 31.1 cm, and the borehole was drilled to a total depth of 915.6 m. The hole was completed to allow access for hydrologic testing and sampling in the target aquifer, which is a lava-flow aquifer known as the Benham aquifer. The completion casing string, set to the depth of 904.3 m, consists of a string of 6 5/8-inch (in.) stainless-steel casing hanging from a string of 7 5/8-in. carbon-steel casing. The stainless-steel casing has one slotted interval at 796.3 to 903.6 m. One piezometer string was installed, which consists of 2 7/8-in. stainless-steel tubing that hangs from 2 3/8-in. carbon-steel tubing via a crossover sub. This string was landed at 903.8 m and is slotted in the interval 795.3 to 903.1 m. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, fluid samples (for groundwater chemistry analysis and tritium measurements), and water-level measurements. The well penetrated 915.6 m of Tertiary volcanic rock, including one saturated lava flow aquifer. Measurements on samples taken from the undeveloped well indicated elevated tritium levels within the Benham aquifer. The maximum tritium level measured with field equipment was 146,131 picocuries per liter from a sample obtained at the depth of 912.0 m. The fluid level was measured in the piezometer string at a depth of 504.5 m on September 26, 2012. All Fluid Management Plan (FMP) requirements for Well ER-20-11 were met. Analysis of monitoring samples and FMP confirmatory samples indicated that fluids generated during drilling at Well ER-20-11 met the FMP criteria for discharge to an unlined sump or designated infiltration area. Well development, hydrologic testing, and sampling will be conducted at a later date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of starting microstructure on helium plasma-materials interaction in tungsten

Here, in a magnetic fusion energy (MFE) device, the plasma-facing materials (PFMs) will be subjected to tremendous fluxes of ions, heat, and neutrons. The response of PFMs to the fusion environment is still not well defined. Tungsten metal is the present candidate of choice for PFM applications such as the divertor in ITER. However, tungsten's microstructure will evolve in service, possibly to include recrystallization. How tungsten's response to plasma exposure evolves with changes in microstructure is presently unknown. In this work, we have exposed hot-worked and recrystallized tungsten to an 80 eV helium ion beam at a temperature of 900 °C to fluences of 2 × 10 23 or 20 × 10 23 He/m 2 . This resulted in a faceted surface structure at the lower fluence or short but well-developed nanofuzz structure at the higher fluence. There was little difference in the hot-rolled or recrystallized material's near-surface (≤50 nm) bubbles at either fluence. At higher fluence and deeper depth, the bubble populations of the hot-rolled and recrystallized were different, the recrystallized being larger and deeper. This may explain previous high-fluence results showing pronounced differences in recrystallized material. The deeper penetration in recrystallized material also implies that grain boundaries are traps, rather than high-diffusivity paths.

36 MATERIALS SCIENCE↗

Multidimensional modeling of non-equilibrium plasma generated by a radio-frequency corona discharge

Low-temperature plasma (LTP) ignition concepts rely on the production of radical and charged species to speed up the onset of combustion in spark-ignition engines. These features are responsible for the superior performance of LTP igniters under extremely dilute combustion operation that is not achievable by conventional spark igniters. Additionally, LTP discharges extend the lifetime of the igniters, due to the avoidance of spark processes. For these reasons, the engine research community and the automotive industry have shown growing interest in this technology in the recent years. As of today, computational fluid-dynamics (CFD) codes typically used by the multi-dimensional engine modeling community do not have reliable models to describe LTP ignition processes. One key missing piece of information is the physical and chemical properties of the plasma and their effect on combustion ignition. Most non-equilibrium plasma simulations reported in literature are based on simplified, canonical geometries, with simple discharge excitation schemes. Here we conduct multi-dimensional modeling of the non-equilibrium plasma generated by an application-relevant radio-frequency (RF) corona discharge in air. Three test cases are simulated, characterized by different environmental pressure levels and peak electrode voltage values at room temperature. Streamer penetration, electron number density, atomic oxygen production, and bulk gas temperature distribution in the first 10 sinusoidal pulses are presented and discussed. This model can be used as a key tool for an in-depth understanding of RF-corona discharge for automotive applications and provides the basis for future implementations of dedicated LTP ignition models in CFD codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of the line-spring model to a cylindrical shell containing a circumferential or axial part-through crack

An approximate solution was obtained for a cylindrical shell containing a part-through surface crack. It was assumed that the shell contains a circumferential or axial semi-elliptic internal or external surface crack and was subjected to a uniform membrane loading or a uniform bending moment away from the crack region. A Reissner type theory was used to account for the effects of the transverse shear deformations. The stress intensity factor at the deepest penetration point of the crack was tabulated for bending and membrane loading by varying three dimensionless length parameters of the problem formed from the shell radius, the shell thickness, the crack length, and the crack depth. The upper bounds of the stress intensity factors are provided by the results of the elasticity solution obtained from the axisymmetric crack problem for the circumferential crack, and that found from the plane strain problem for a circular ring having a radial crack for the axial crack. The line-spring model gives the expected results in comparison with the elasticity solutions. Results also compare well with the existing finite element solution of the pressurized cylinder containing an internal semi-elliptic surface crack.

Delale, F.↗

Backscatter-to-Extinction Ratios in the Top Layers of Tropical Mesoscale Convective Systems and in Isolated Cirrus from LITE Observations

Cloud-integrated attenuated backscatter from observations with the Lidar In-Space Technology Experiment (LITE) was studied over a range of cirrus clouds capping some extensive mesoscale convective systems (MCSS) in the Tropical West Pacific. The integrated backscatter when the cloud is completely attenuating, and when corrected for multiple scattering, is a measure of the cloud particle backscatter phase function. Four different cases of MCS were studied. The first was very large, very intense, and fully attenuating, with cloud tops extending to 17 km and a maximum lidar pulse penetration of about 3 km. It also exhibited the highest integrated attenuated isotropic backscatter, with values in the 532-nm channel of up to 2.5 near the center of the system, falling to 0.6 near the edges. The second MCS had cloud tops that extended to 14.8 km. Although MCS2 was almost fully attenuating, the pulse penetration into the cloud was up to 7 km and the MCS2 had a more diffuse appearance than MCS1. The integrated backscatter values were much lower in this system but with some systematic variations between 0.44 and 0.75. The third MCS was Typhoon Melissa. Values of integrated backscatter in tt-ds case varied from 1.64 near the eye of the typhoon to between 0.44 and 1.0 in the areas of typhoon outflow and in the 532-nm channel. Mean pulse penetration through the cloud top was 2-3 km, the lowest penetration of any of the systems. The fourth MCS consisted of a region of outflow from Typhoon Melissa. The cloud was semitransparent for more than half of the image time. During that time, maximum cloud depth was about 7 km. The integrated backscatter varied from about 0.38 to 0.63 in the 532-nm channel when the cloud was fully attenuating. In some isolated cirrus between the main systems, a plot of integrated backscatter against one minus the two-way transmittance gave a linear dependence with a maximum value of 0.35 when the clouds were fully attenuating. The effective backscatter-to-extinction ratios, when allowing for different multiple-scattering factors from space, were often within the range of those observed with ground-based lidar. Exceptions occurred near the centers of the most intense convection, where values were measured that were considerably higher than those in cirrus observed from the surface. In this case, the values were more compatible with theoretical values for perfectly formed hexagonal columns or plates. The large range in theoretically calculated back- scatter-to-extinction ratio and integrated multiple-scattering factor precluded a closer interpretation in terms of cloud microphysics.

Platt, C. M. R.↗

Remote Optical Recession Measurement of Orion Thermal Protection System

For the Orion Multi-Purpose Crew Vehicle (MPCV) project, NASA is minimizing the use of onboard diagnostics, especially external sensors that penetrate the structure. Nonetheless, there is a desire to measure the Thermal Protection System (TPS) recession during reentry. One noninvasive technique currently under investigation is the insertion of indicator metals into the heatshield at varied depths and spatial locations. A remote (airborne) spectrometer detects the emissions from the ionized metal to reveal the time (thus depth) of the metal release. Innovative processing enables the emission features from trace amounts of the selected metals to be reliably detected against the complex and structured spectral background of the shock layer and ablated TPS material. The con-cept has been proven viable through ground testing at NASA HyMETS and AHF arc jet facilities using the Orion TPS material (Avcoat). This presentation highlights the parametric testing that was conducted to select the optimal indicator metals and to assess the accuracy of remote recession measurements using this technique. The CONOPS for integrating the technique into the Orion flight tests is also presented. This includes the onboard indicator metal "seeded plugs" and the offboard airborne sensor platform that would be deployed.

Scriven, Gordon↗

Definition of Beam Diameter for Electron Beam Welding

It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

42 ENGINEERING↗

Electron and proton absorption calculations for a graphite/epoxy composite model

The Bethe-Bloch stopping power relations for inelastic collisions were used to determine the absorption of electron and proton energy in cured neat epoxy resin and the absorption of electron energy in a graphite/epoxy composite. Absorption of electron energy due to bremsstrahlung was determined. Electron energies from 0.2 to 4.0 MeV and proton energies from 0.3 to 1.75 MeV were used. Monoenergetic electron energy absorption profiles for models of pure graphite, cured neat epoxy resin, and graphite/epoxy composites are reported. A relation is determined for depth of uniform energy absorption in a composite as a function of fiber volume fraction and initial electron energy. Monoenergetic proton energy absorption profiles are reported for the neat resin model. A relation for total proton penetration in the epoxy resin as a function of initial proton energy is determined. Electron energy absorption in the composite due to bremsstrahlung is reported. Electron and proton energy absorption profiles in cured neat epoxy resin are reported for environments approximating geosynchronous earth orbit.

Long, E. R., Jr.↗

Passive microwave sensing of snow characteristics over land

Truck-mounted, airborne, and spaceborne systems with various radiometers ranging in wavelength from 0.8 to 21 cm were used to measure the brightness temperatures of snow-covered areas at test sites near Steamboat Springs and Walden, Colorado. The brightness temperature at a short wavelength (0.8 cm) was found to decrease more rapidly with increasing snow depth than the brightness temperature at a longer wavelength (6 cm). More scattering of the shorter-wavelength radiation by the snow crystals results in a lower brightness temperature. The longer-wavelength (6 cm) radiation penetrates through meters of dry snowpack and is useful for the assessment of the underlying ground conditions.

Chang, A. T. C.↗

Application of the line-spring model to a cylindrical shell containing a circumferential or axial part-through crack

The line-spring model developed by Rice and Levy (1972) is used to obtain an approximate solution for a cylindrical shell containing a part-through surface crack. A Reissner type theory is used to account for the effects of the transverse shear deformations, and the stress intensity factor at the deepest penetration point of the crack is tabulated for bending and membrane loading by varying three-dimensionless length parameters of the problem formed from the shell radius, the shell thickness, the crack length, and the crack depth. The upper bounds of the stress intensity factors are provided, and qualitatively the line-spring model gives the expected results in comparison with elasticity solutions.

Delale, F.↗

Thermal effects of insolation propagation into the regoliths of airless bodies

The planetary surface thermal models used in the present study are composed of particles which, while bright and optically thin in the visual, are dark and opaque in the thermal IR. It is assumed that insolation is absorbed over a finite regolith distance whose scale length relative to diurnal skin depth for thermal diffusion can be substantial. Attention is given to the lower daytime and higher nighttime temperatures predicted by comparison with models assuming absorption only at the surface. It is noted that, with sufficiently deep penetration of insulation and high thermal IR particle opacity, a solid-state greenhouse can result.

Brown, Robert Hamilton↗

X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

Wurth, Laura↗

Techno-Economic Performance of Eavor Loop 2.0

This project evaluated techno-economic performance for a sample Eavor-Loop 2.0 design for electricity production and direct-use heating. The Eavor-Loop 2.0 design investigated is a 7.5-km deep closed-loop geothermal system consisting of 12 laterals for a total of more than 90 km of downhole well and lateral length. Both a high geothermal gradient scenario of 60 degrees C/km and a low geothermal gradient scenario of 30 degrees C/km were considered. With pure water injected at 60 degrees C and 80 kg/s, reservoir simulations with the Slender-Body Theory simulator indicate average production temperatures over a 30-year lifetime of ~125 degrees C and ~210 degrees C for the low and high geothermal gradient scenario, respectively. These correspond to heat production of ~22 M Wth and ~51 M Wth, respectively. Using IPSEpro simulations, we find average power production of ~2.2 M We and ~8.6 M We, respectively, for a subcritical organic Rankine cycle power plant with air-cooled condensers. Cost estimates indicate the overall capital and levelized costs are dominated by the lateral drilling cost. Obtaining a levelized cost of electricity below $70/M Wh requires a geothermal gradient of 60 degrees C/km, a discount rate below 9%, and lateral drilling cost below $400/m. A well cost model indicates that ~$400/m for the Eavor-Loop 2.0 design investigated can be obtained for a drilling rate of penetration about 40 ft/hr (with bit life of 50 hours), and omitting casing and cement. Traditional (geothermal) well drilling has achieved these drilling rate conditions, including the Utah FORGE project where the rate of penetration has exceeded 50 ft/hr in granite. However, it is unclear if these conditions are still valid for drilling the Eavor-Loop 2.0 laterals (i.e., ~82 km of laterals at 4 to 7.5-km vertical depth with rock temperatures up to 460 degrees C), as such downhole completion has never been developed before. Competitive levelized cost of heat values ($1.2-$8.2/GJ) are calculated, even for the low geothermal gradient scenario (30 degrees C/km) and lateral drilling cost of $600/m.

advanced geothermal system↗

Investigating Buried Ice at Askja Volcano, Northern Iceland using Ground Penetrating Radar: A Planetary Analog Perspective

Shallow subsurface ice deposits on Mars and the Moon have been identified as potential targets for in situ resource utilization by future crewed missions to the surfaces of these bodies. On Mars, such deposits have been identified through a variety of orbital measurements at the poles, mid-latitudes, and even preserved by volcanic ash near the Tharsis Montes. At some locations, massive ice deposits have been documented to be 100 m in thickness at depths as shallow as 1 m. On the Moon, the presence of thick, massive ice has not been confirmed; however, orbital observations indicate that the upper 1-2 m of regolith may contain a few weight percent in thermally favorable locations. Eruptions of the Askja Volcano in March, 1875 and November, 1961 deposited abundant pyroclasts, which blanketed and insulated fresh snowfall that later densified into massive ice and is preserved today. The pyroclasts consist of a buff colored pumice from the eruption in 1875 and basaltic lapilli and ash from the eruption in 1961. The largely unvegetated, unconsolidated nature of the pyroclasts and their stratigraphic relationships with shallow subsurface ice make them potentially analogous to some ice deposits within regolith and pyroclasts at the Moon and Mars. Ground penetrating radar(GPR) can be used by future human or robotic missions to identify water ice similarly preserved in the shallow subsurface of these bodies. Our team conducted over 66 GPR surveys inside and surrounding the Askja caldera in August 2019 at 200 and 400 MHz to map both the volcanic deposits and the subsurface ice deposits. We also used a hammer drill augur to take boreholes in order to confirm subsurface stratigraphy and the presence of ice down to 1-1.5 m and aerial surveys using a Mavic 2 Pro quadcopter at each site for additional context. We observed shallow ice deposits within pore spaces of the pyroclasts at depths of ~15-30 cm and pure ice deposits at varying depths (0.6-1 m) as thick as 2-3 m. We also plan to use the data to characterize the frequency-dependent attenuation of the radar signal as it travels through volcanoclastic material and ice in the subsurface. Our investigation of Askja as a planetary analog will provide insight into analytical methods that can be used to investigate subsurface water ice from surface operations at other terrestrial bodies.

Geophysics↗