Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTIAL PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

GaN for LED applications

In order to improve the synthesis of GaN the effect of various growth and doping parameters has been studied. Although Be, Li, Mg, and Dy can be used to overcompensate native donors, the most interesting acceptor element is Zn. The emission spectrum and the luminescence efficiency depend on the growth temperature (below 800 C), on the partial pressure of the doping impurity, and on the duration of growth. Blue-green electroluminescence with a power efficiency of 0.1 percent and a brightness of 850 fL (at 0.6 mA and 22.5 V) was obtained. Some diodes allow the color of the emitted light to change by reversing the polarity of the bias. Continuous operation of a diode over a period of 5 months showed no evidence of degradation. The luminescence properties of ion-implanted GaN were studied. Delay effects were found in the electroluminescence of diodes, although, with a dc bias, a 70-MHz modulation was possible.

Pankove, J. I.↗

Development of system design information for carbon dioxide using an amine type sorber

Development work on system design information for amine type carbon dioxide sorber is reported. Amberlite IR-45, an aminated styrene divinyl benzene matrix, was investigated to determine the influence of design parameters of sorber particle size, process flow rate, CO2 partial pressure, total pressure, and bed designs. CO2 capacity and energy requirements for a 4-man size system were related mathematically to important operational parameters. Some fundamental studies in CO2 sorber capacity, energy requirements, and process operation were also performed.

Rankin, R. L.↗

Experimental petrology and origin of Fra Mauro rocks and soil.

Results of melting experiments over the pressure range from 0 to 20 kb on Apollo 14 igneous rocks 14310 and 14072, and on comprehensive fines 14259. It is found that low-pressure crystallization of rocks 14310 and 14072 proceeds as predicted from the textural relationships displayed by thin sections of these rocks. The mineralogy and textures of these rocks are the result of near-surface crystallization. The chemical compositions of these lunar samples all show special relationships to multiply saturated liquids in the system anorthite-forsterite-fayalite-silica at low pressure. Partial melting of a lunar crust consisting largely of plagioclase, low-calcium pyroxene, and olivine, followed by crystal fractionation at the lunar surface, is a satisfactory mechanism for the production of the igneous rocks and soil glasses sampled by Apollo 14. The KREEP component of other lunar soils, may have a similar origin.

Walker, D.↗

Fundamental equations of a mixture of gas and small spherical solid particles from simple kinetic theory.

The fundamental equations of a mixture of a gas and pseudofluid of small spherical solid particles are derived from the Boltzmann equation of two-fluid theory. The distribution function of the gas molecules is defined in the same manner as in the ordinary kinetic theory of gases, but the distribution function for the solid particles is different from that of the gas molecules, because it is necessary to take into account the different size and physical properties of solid particles. In the proposed simple kinetic theory, two additional parameters are introduced: one is the radius of the spheres and the other is the instantaneous temperature of the solid particles in the distribution of the solid particles. The Boltzmann equation for each species of the mixture is formally written, and the transfer equations of these Boltzmann equations are derived and compared to the well-known fundamental equations of the mixture of a gas and small solid particles from continuum theory. The equations obtained reveal some insight into various terms in the fundamental equations. For instance, the partial pressure of the pseudofluid of solid particles is not negligible if the volume fraction of solid particles is not negligible as in the case of lunar ash flow.

Pai, S. I.↗

Absolute calibration of Apollo lunar orbital mass spectrometer.

Recent experiments were conducted in Langley Research Center's molecular beam system to perform an absolute calibration of the lunar orbital mass spectrometer which was flown on the Apollo 15 and 16 missions. Tests were performed with several models of the instrument using two test gases, argon and neon, in the 1 ntorr to .1 picotorr range. Sensitivity to argon at spacecraft orbital velocity was .00028 A/torr enabling partial pressures in the .01-picotorr range to be measured at the spacecraft altitude. Neon sensitivity was nearly a factor of 5 less. Test data support the feasibility of using the lunar orbital mass spectrometer as a tool to gather information about the lunar atmosphere.

Yeager, P. R.↗

A monkey metabolism pod for space-flight weightlessness studies.

The system described will permit quantitative physiological studies in adult monkeys, weighing from 8 to 14 kg, during future space flights. The system comprises a fiberglass pod containing a comfortable restraint couch for the animal. The pod is divided into upper and lower halves. When the monkey occupies the couch, a rubber belly-band forms a gas seal between the upper and lower portions of the animal. The upper-pod ventilating air stream is monitored for the partial pressures of oxygen, carbon dioxide, nitrogen, and water to permit continuous metabolic gas-exchange measurements for computation of metabolic energy expediture. The lower pod is lined with ashless filter paper for excreta collection.

Pace, N.↗

Six-man, self-contained carbon dioxide concentrator system

A six man, self contained electrochemical carbon dioxide concentrating subsystem was successfully designed and fabricated. It was a preprototype engineering model designed to nominally remove 6.0 kg (13.2 lb) CO2/day with an inlet air CO2 partial pressure of 400 N/sq m (3 mm Hg) and an overcapacity removal capability of 12.0 kg (26.4 lb) CO2/day. The design specifications were later expanded to allow operation at space station prototype CO2 collection subsystem operating conditions.

Powell, J. D.↗

In situ detection of microbial respiration in soils and salt flats

Increase in CO2 partial pressures over a desert soil treated with casamino-acids glucose solution correlated with bacterial growth. Few or no increases in numbers of bacteria or CO2 concentrations were noted in similar plots treated with water only or receiving no treatment. Growth in the soil appeared to be severely nutrient limited during the 10 day experiment. Especially rapid growth took place between the third and fifth day, when temperatures ranged from 0 deg. (night) to a maximum of 17.4 deg. (day). Under the conditions of the experiment, intermittent CO2 assay was an insensitive indicator of growth, possibly because of restiction of gas escape by the desert pavement or solution, exchange, or precipitation of carbonate, but more likely because of inefficient sealing of hoods to and below the soil surface. CO2 assay was unable to detect microbial successions. The unpredictable course of these successions, plus unpredictable relative retentions mitigates against assay of organic gases as reliable in situ detection of microbial activity, except perhaps in very alkaline environments such as Owens Lake salts.

Tew, R. W.↗

Acute metabolic and physiologic response of goats to narcosis

Assessment of the metabolic consequences of exposure to elevated partial pressures of nitrogen and helium under normobaric and hyperbaric conditions in goats. The results include the finding that hyperbaric nitrogen causes and increase in metabolic rate and a general decrease in blood constituent levels which is interpreted as reflecting a shift toward fatty acid metabolism at the expense of carbohydrates. A similar but more pronounced pattern was observed with hyperbaric helium.

Schatte, C. L.↗

Equilibration temperatures in enstatite chondrites

Equilibration temperatures for enstatite chondrites are calculated using a method suggested by Larimer (1968). The temperatures range from 640 to 840 C. The method yields temperatures which, in principle, are correct on a relative scale, but the absolute error may be as large as 150 C. There is a good correlation between the calculated temperatures and petrologic type as well as other mineralogic characteristics and bulk composition. Partial pressures of sulfur and oxygen at the time of equilibration ranged from about 10 to the minus 8th to 10 to the minus 12th atm and from about 10 to the minus 28th to 10 to the minus 37th atm, respectively.

Larimer, J. W.↗

Mercury's atmosphere from Mariner 10 - Preliminary results

Analysis of data obtained by the ultraviolet experiment on Mariner 10 indicates that Mercury is surrounded by a thin atmosphere consisting in part of helium. The partial pressure of helium at the terminator is about 5 trillionths of a millibar. The total surface pressure of the atmosphere is less than about 2 billionths of a millibar. Upper limits are set for the abundance of various gases, including hydrogen, oxygen, carbon, argon, neon, and xenon. The wavelength dependence of Mercury's surface albedo is similar to that of the moon over a broad range of wavelengths from 500 to 1600 A. Strong signals were recorded by the airglow instrument as Mariner 10 passed through the cavity behind Mercury. They are as yet unexplained but may provide information on the properties of the local plasma.

Broadfoot, A. L.↗

Development of a six-man, self-contained carbon dioxide collection subsystem for spacecraft application

Life Systems, working with NASA, has developed an electrochemical, six-man, self-contained carbon dioxide concentrator subsystem (CX-6) designed to normally remove 13.2 lb/day of CO2 while maintaining the CO2 partial pressure (pCO2) of the cabin atmosphere at 3 mm Hg or less. The CX-6 was subjected to extensive parametric and endurance testing. The effects of operating conditions on CO2 removal and electrical efficiencies were determined, including effects of hydrogen (H2) flow rate, process airflow rate, pCO2, operating temperature and current density. A total of 209 days of operation was accumulated. The subsystem was designed with self-contained electronic control and monitoring instrumentation. The CX-6 was redesigned and repackaged into the CO2 collection subsystem for the air revitalization group of the space station prototype.

Schubert, F. H.↗

Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study

An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.

Prokopius, P. R.↗

One man electrochemical air revitalization system

An integrated water vapor electrolysis (WVE) hydrogen depolarized CO2 concentrator (HDC) system sized for one man support over a wide range of inlet air conditions was designed, fabricated, and tested. Data obtained during 110 days of testing verified that this system can provide the necessary oxygen, CO2 removal, and partial humidity control to support one man (without exceeding a cabin partial pressure of 3.0 mmHg for CO2 and while maintaining a 20% oxygen level), when operated at a WVE current of 50 amperes and an HDC current of 18 amperes. An evaluation to determine the physical properties of tetramethylammonium bicarbonate (TMAC) and hydroxide was made. This provides the necessary electrolyte information for designing an HDC cell using TMAC.

Huddleston, J. C.↗

Argon in the Martian atmosphere

Heretofore undetected argon may be a significant constituent of the Martian atmosphere with a partial pressure of 1.8 mbar. The addition of argon to the 5.5 plus or minus 0.8 mbar of CO2, deduced from ground-based spectroscopy, is consistent with the values of total pressure deduced from the Mariner radio occulation measurements. The presence of argon in the Martian atmosphere contributes to the cooling of the upper thermosphere and exosphere and may explain the difference between predicted and observed temperatures. The argon concentrations predicted here may be related to the recent observation of several tens of per cent of an inert gas, deduced from Mars-6 data.

Levine, J. S.↗

Calculation of complex equilibria involving vaporization into vacuum

A simplified, direct approach is presented to the description of complex equilibria involving vaporization into vacuum. Emphasis is on the basic problem-solving process and on modification of existing techniques. Sequential solutions are presented to problems involving purification of a melt by vaporization into vacuum. The effects of concentration of melt and oxygen partial pressures on vaporization rates are demonstrated.

Paule, R. C.↗

Preflight studies on tolerance of pocket mice to oxygen and heat. II - Effects on lungs

An electron microscope examination was carried out on the lungs of 11 pocket mice (Perognathus longimembris) that breathed oxygen at 10 psi or 12 psi partial pressure over a period of 7 d, at the end of which time they were decompressed to sea-level O2 pressure, either suddenly or in 30, 60, or 90 min. Vesiculation was noted in the endothelium of the alveolar-capillary wall in most of the animals and, occasionally, blebbing. Some mitochrondria were swollen in a few of the animals. Alveolar exudate was, in general, sparse. Compared with the lungs of other rodents, the lungs of pocket mice appeared relatively resistant to the toxic effects of oxygen. This conclusion needs, however, to be tempered by the fact that 5% N2 was used in the tests reported here. Nonetheless, the results suggest that the oxygen pressures anticipated on the flight of Apollo XVII should be well tolerated by the pocket mice.

Harrison, G. A.↗

Switching regulator emission control circuit for ion sources

An electron emission control circuit of the switching regulator type operating at 100 kHz has been developed which maintains a constant emission current within 0.1% for a cathode power demand variation of approximately 100%. The power output stage has an efficiency of 67%, and the overall efficiency is 45% when driving a thoria-coated iridium cathode having a nominal resistance at operating temperature of 2.5 ohms. Under optimum conditions, the bus power demand is 1.75 W. The circuit is useful in controlling the electron emission current of ion sources in applications which involve a substantial variation of the cathode work function, such as oxygen partial pressure measurements over a large dynamic range.

Clay, F. P., Jr.↗