Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Ballistic vs. diffusive heat transfer across nanoscopic films of layered crystals

We use non-equilibrium molecular dynamics to study the heat transfer mechanism across sandwich interfacial structures of Si/n-atomic-layers/Si, with 1 ≤ n ≤ 20 and atomic layers composed of WSe{sub 2} and/or graphene. In the case of WSe{sub 2} sheets, we observe that the thermal resistance of the sandwich structure is increasing almost linearly with the number of WSe{sub 2} sheets, n, indicating a diffusive phonon transport mechanism. By contrast in the case of n graphene layers, the interfacial thermal resistance is more or less independent on the number of layers for 1 ≤ n ≤ 10, and is associated with ballistic phonon transport mechanism. We attribute the diffusive heat transfer mechanism across WSe{sub 2} sheets to abundant low frequency and low group velocity optical modes that carry most of the heat across the interface. By contrast, in graphene, acoustic modes dominate the thermal transport across the interface and render a ballistic heat flow mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flow Characteristics of UHV Nitrogen Arcjet

Flow characteristics in the nozzle of a nitrogen arcjet have been simulated by a model. Electrons, ions, and neutral atoms and molecules are represented as separate species. Dissociation, ionization, and recombination are treated as separate reactions. Thermal non-equilibrium is represented by a two-temperature model. Energy input to plasma from the arc is modeled as a source determined by local current and electrical conductivity. Momentum and energy losses and recombinations at the nozzle wall are included as source/sink determined by fluxes to the wall. The results show essentially frozen gas-phase reactions and thermal nonequilibrium due to Joule heating of electrons and in the expansion part of the nozzle. Wall interactions have strong effects on the results, indicating that they play important roles in the flow due to very high surface area relative to the volume of the plasma. For example, plasma velocity decreases from 6000 m per s without wall interactions to 3000 m per s with modest amount of wall interactions. These results also show reasonable agreement with optical emission measurements, which confirms that the arcjet plasma is far from LTE. The spectra suggest nitrogen dissociation levels of 0.3% - 9%, depending on nitrogen flow rate and arc plasma current, which also determine the relative amounts of excited atomic and molecular nitrogen. Langmuir probe studies of the source show that electron and ion fluxes increase with increasing power, and that the ion energy distribution shifts to lower energies. Typical ion fluxes were on the order of 4E-9 A/cm**2 with a maximum ion kinetic energy of 3.5eV. The median electron energy was 1eV, with a maximum of less than 4eV.

Chang, C. H.↗

Optical and acoustical measuring techniques

The paper reviews the techniques of laser and acoustic Doppler measurement of fluid velocities in confined and free flows. The main mathematical relations are presented, and some systems are studied. Resolution properties of coaxial, bistatic, and pulsed CO2 laser Doppler velocimeter systems are compared. Schematics for pulsed and continuous wave acoustic Doppler systems are discussed. Both of these types of systems benefit from using a bistatic configuration instead of a coaxial system. The pulsed systems avoid contamination of source noise by not sampling until after the source noise has passed the receiver. Comparison of wind velocity measured with a pulsed acoustic Doppler and with a boundary layer profile is made.

Cliff, W. C.↗

Output statistics of laser anemometers in sparsely seeded flows

It is noted that until very recently, research on this topic concentrated on the particle arrival statistics and the influence of the optical parameters on them. Little attention has been paid to the influence of subsequent processing on the measurement statistics. There is also controversy over whether the effects of the particle statistics can be measured. It is shown here that some of the confusion derives from a lack of understanding of the experimental parameters that are to be controlled or known. A rigorous framework is presented for examining the measurement statistics of such systems. To provide examples, two problems are then addressed. The first has to do with a sample and hold processor, the second with what is called a saturable processor. The sample and hold processor converts the output to a continuous signal by holding the last reading until a new one is obtained. The saturable system is one where the maximum processable rate is arrived at by the dead time of some unit in the system. At high particle rates, the processed rate is determined through the dead time.

Edwards, R. V.↗

Schlieren system and method for moving objects

A system and method are provided for recording density changes in a flow field surrounding a moving object. A mask having an aperture for regulating the passage of images therethrough is placed in front of an image recording medium. An optical system is placed in front of the mask. A transition having a light field-of-view and a dark field-of-view is located beyond the test object. The optical system focuses an image of the transition at the mask such that the aperture causes a band of light to be defined on the image recording medium. The optical system further focuses an image of the object through the aperture of the mask so that the image of the object appears on the image recording medium. Relative motion is minimized between the mask and the transition. Relative motion is also minimized between the image recording medium and the image of the object. In this way, the image of the object and density changes in a flow field surrounding the object are recorded on the image recording medium when the object crosses the transition in front of the optical system.

Weinstein, Leonard M.↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

DRILL Interface Makes Ion Soft Landing Broadly Accessible for Energy Science and Applications

Polyoxometalates (POM) have been deposited onto carbon nanotube (CNT) electrodes using benchtop ion soft landing (SL) enabled by a vortex-confined electrohydrodynamic desolvation process. The device is based on the dry ion localization and locomotion (DRILL) mass spectrometry interface of Fedorov and co-workers. By adding electrospray emitters, heating the desolvation gas, and operating at high gas flow rates, it is possible to obtain stable ion currents up to -15 nA that are ideal for deposition. Coupled with ambient ion optics, this interface enables desolvated ions to be delivered to surfaces while excluding solvent and counterions. Electron microscopy of surfaces prepared using the device reveal discrete POM and no aggregation that degrades electrode performance. Characterization of POM-coated CNT electrodes in a supercapacitor showed an energy storage capacity similar to that achieved with SL in vacuum. For solutions that produce primarily a single ion by electrospray ionization, benchtop SL offers a simpler and less costly approach for surface modification with applications in catalysis, energy storage, and beyond.

Johnson, Grant E.↗

A cooling flow cluster at redshift z = 0.2

The cluster of galaxies 1E0839.9 + 2938, discovered in X-ray observations by Nesci et al. (1988), is characterized on the basis of VLA 6-cm radio observations, Whipple Observatory CCD photometry, and spectroscopic observations obtained with the Multiple Mirror Telescope and the 88-inch University of Hawaii Telescope at Mauna Kea. The data are presented in tables, maps, and sample images and spectra and briefly characterized. The bright X-ray object is identified with a cluster at redshift z = 0.195; its central galaxy has radio emission of 1.1 x 10 exp 24 W/Hz as well as strong optical line emission which is not restricted to its nucleus. It is concluded that 1E0839.9 + 2938 is a cooling-flow cluster similar to 3C295 (found at z = 0.461 by Henry et al., 1986). The need for space observations (by Rosat or the AXAF) to determine the object's X-ray luminosity distribution is indicated.

Wolter, Anna↗

Utah FORGE 3-2417: Fiber-Optic Geophysical Monitoring of Reservoir Evolution - Workshop Presentation

This is a presentation on the Fiber-Optic Geophysical Monitoring of Reservoir Evolution at the Utah FORGE Milford Site project by Rice University, presented by Prof. Jonathan Ajo-Franklin. The project's objective was to develop an end-to-end fiber-optic sensing approach for EGS to track the initial zone of fracture creation, zones of connected mechanically compliant fractures, and zones of flowing fractures linking the injection/production well pair. This approach would also be used to integrate data into an improved thermo-hydro-mechanical model (THM). This presentation was featured in the Utah FORGE R&D Annual Workshop on September 8, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗

Characterization of Reactant Mixing in a Rotating Detonation Engine Using Schlieren Imaging and Planar Laser Induced Fluorescence

A linearized version of an axial flow injector used in an air breathing rotating detonation engine (RDE) has been developed to aid in the study of reactant mixing. The test bed was designed with optical access so that a variety of qualitative and quantitative imaging techniques may be applied. Non-reacting, pure mixing studies are presented here. In this initial study high speed Schlieren video is used to understand the evolution of the flow field in time and across an operating regime analogous to its RDE counterpart. Basic flow features are identified and average flow field images are generated and used to assess how the average flow field evolves across the operating regime. Acetone-tracer planar laser induced fluorescence (PLIF) is used to generate plots of instantaneous and average molar fraction and initial data is presented here.

Duvall, James↗

Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of a supersonic swept ramp injector using laser-induced iodine fluorescence

Planar measurements of injectant mole fraction and temperature have been conducted in a nonreacting supersonic combustor configured with underexpanded injection in the base of a swept ramp. The temperature measurements were conducted with a Mach 2 test section inlet in streamwise planes perpendicular to the test section wall on which the ramp was mounted. Injection concentration measurements, conducted in cross flow planes with both Mach 2 and Mach 2.9 free stream conditions, dramatically illustrate the domination of the mixing process by streamwise vorticity generated by the ramp. These measurements, conducted using a nonintrusive optical technique (laser-induced iodine fluorescence), provide an accurate and extensive experimental data base for the validation of computation fluid dynamic codes for the calculation of highly three-dimensional supersonic combustor flow fields.

Hartfield, Roy J.↗

Refractive Index Effects on Radiation in an Absorbing, Emitting, and Scattering Laminated Layer

A simple set of equations is derived for predicting temperature radiative energy flow in a two-region semitransparent laminated layer in the limit of zero heat conduction. The composite is heated on its two sides by unequal amounts of incident radiation. The two layers of the composite have different refractive indices, and each material absorbs, emits, and isotropically scatters radiation. The interfaces are diffuse, and all interface reflections are included. To illustrate the thermal behavior that is readily calculated from the equations, typical results an given for various optical thicknesses and refractive indices of the layers. Internal reflections have a substantial effect on the temperature distribution and radiative heat flow.

Siegel, R.↗

Overview of Extractive and Optical PM Measurements from the NASA SE-5 High Pressure Flame Diagnostics Laboratory

Soot emissions measurements of multiphase non-premixed flames are sparse in the literature due to the complexities of sampling in such environments. We present an overview from on-going work at the NASA SE-5 High Pressure Flame Diagnostics laboratory focusing on soot and gaseous emissions at elevated pressures. SE-5 is a gaseous and liquid fueled high pressure flame tube facility capable of operating at pressures up to 880 psia, cooling capacity of 4,000,000 BTU/hr, liquid fuel flow rates up to 2 GPH, and an equivalence ratio range of 0.2 (fuel lean) to 4 (fuel rich). SE-5 provides optical access via four UV-grade fused silica optical windows of the primary reaction zone enabling non-intrusive optical diagnostics of the flame.

Soot↗