Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Convergence of Emerging Technologies - EAGL Test Information

The Emergency Automatic Gunshot Detection and Lockdown (EAGL) system provides automatic, autonomous, and timely gunshot detection in both indoor and outdoor environments. This system uses both wired and wireless devices. Self-contained wireless EAGL sensors passively “listen” for gunshot events. These devices also perform a single, daily supervisory heartbeat (HB) function to include a device self-check with reporting capability. Transmissions are received by an assigned EAGL Gateway, which translates the RF sensor data to a PoE network format solely for use by the EAGL system server. The server then performs additional processes after data receipt, which include but are not limited to: event validation and logging, GUI presentation, notifications, and other independent operations.

47 OTHER INSTRUMENTATION↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Domesticating the green alga Scenedesmus obliquus

Microalgae cultivation processes exist only for a few species used in commercial applications. Their domestication is still in its infancy, with major advances required, specifically to overcome limiting factors in microalgae production. The goal is to develop superior strains without the need of genetic technologies that would require lengthy regulatory permits, and often limit consumer acceptance. Adaptive Laboratory Evolution techniques, alone or in conjunction with sexual recombination, can allow for rapid develop of improved strains and their industrial production. Approaches include increased photon utilization efficiency by cultures operating under full sunlight conditions due to higher light saturation levels, allowing for higher productivities under outdoor conditions. Decades of research yielded some promising results under controlled conditions with a few specific mutant strains. However, these failed to achieve the anticipated higher productivities in actual algal mass cultures, in part due to the inability of mutations to overcome photoinhibition, reactive oxygen species, and other pleiotropic impacts on photosynthesis.

09 BIOMASS FUELS↗

Optimizing Selection Pressures and Pest Management to Maximize Cultivation Yield (OSPREY) (Final Technical Report)

This project was proposed in response to AOI 1, Cultivation Intensification Processes for Algae, within the FY19 Bioenergy Technologies Office Multi-Topic Funding Opportunity Announcement (FOA Number: DE-FOA-0002029). The work was designed to address a critical industry need to improve annualized productivity, stability, and quality of algal production strains for biofuels and bioproducts. The overall project goals were to generate process innovations rooted in established outdoor systems for strain selection, improvement, maintenance, and cultivation as well as pest detection and tracking. Planned advances included a 50% improvement in harvest yield based on AFDW (g m 2 d -1 ), 50% improvement in robustness based on stability metrics (e.g., high-productivity cultivation days, pond uptime), and 20% improvement in conversion yield. Individually, each of our planned process improvements (e.g., pest tracking) had the potential to increase productivity. However, to realize increases in yield at the system level, improvements to one unit’s process must be balanced against potential effects on other processes. For example, changes to strains, cultivation, and pest management developed in isolation may hurt other unit operations. Therefore, a critical success factor of the project was the integration of the pipeline components, achieved through iterative field-to- (short term) lab testing. In addition, through sustainability models, we evaluated how improvements would alter industry scenarios.

09 BIOMASS FUELS↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dense Image Matching Uncertainty Estimation and Confidence Metrics

Dense stereo matching takes overlapping image pairs as input and outputs a disparity map which encodes pixel-by-pixel matches between the images. Recently, there has been an interest in ranking the quality, or even quantifying the accuracy, of disparity estimates. The proposed methods can be described as either uncertainty estimators or confidence metrics. Uncertainty estimators are a small minority of the research. However, they have the potential to be the most useful because they estimate disparity accuracy (in pixel units) that can be used to threshold matches or carried forward using error propagation. The majority of the research deals with confidence metrics which give an ordinal (or binary) ranking of a match’s quality relative to other matches. Confidence metrics do not have units and thus are useful primarily for thresholding matches from mismatches. The methods could also be described as handcrafted or deep-learning based. The majority of the research focused on outdoor driving scenes. Hence, our interest–application to a satellite semi-global matching pipeline–is a domain shift that may challenge deep-learning based methods. We conclude by recommending five handcrafted and two deep-learning based methods for evaluation in our pipeline.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

BACKFLIP: A Comparison of Market-Benchmark Backsheet Technologies to Novel Non-Fluoro-Based Coextruded Materials and Their Correlation and Impact on PV Module Degradation Rates: Final Results of the Study at 4000 Hours or 2 Years

As the photovoltaic (PV) industry is rapidly expanding around the world, there has been an increasing interest in extending the lifespan of PV modules. Concern has also emerged regarding the recyclability of modules and their component materials, including fluoropolymer-based backsheets. Laminated polyethylene-terephthalate (PET) core backsheets have traditionally been used in the PV industry, but new, co-extruded polyolefin (PO) backsheets show promise as an improved alternative. Mini-module and coupon samples of seven different backsheets (made of layers including contemporary PET and fluoropolymers, novel PO, and polyamide (PA) materials) were run through hygrometric- or UV photolytic-accelerated aging to identify and better understand each material's degradation modes and the backsheets' field reliability. In addition to the artificial aging, the natural weathering methods used in this study are described. The comprehensive set of chemical, mechanical, and structural characterizations at intermittent read points in this study is presented, including: visual appearance and color; gloss; mechanical tensile testing; I-V performance; electroluminescence (EL) imaging; dielectric breakdown; FTIR-chemical structure; X-ray-polymer structure (WAXS); and DSC-crystalline content. After 4000 h of accelerated aging or 2y of outdoor aging, a strong correlation occurs between initial physical characteristics (mechanical tensile test) and operating performance (EL and I-V characteristics).

14 SOLAR ENERGY↗

Scribe and Interface Modification for Stable Halide Perovskite Modules (CRADA Final Report)

This project provided funding to NREL/Tandem PV by EERE-SETO and has the goal of improving perovskite module stability by at least a factor of 2 without sacrificing initial efficiency. This will be demonstrated using 3"x3" minimodules and will be tested according to the Innovation and Entrepreneurship Center (IEC) standards and demonstrated using outdoor testing. A CRADA was established between NREL and Tandem PV to address the goals for the funded effort.

14 SOLAR ENERGY↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decision-Model Supported Algal Cultivation Process Enhancement (DMSACPE) (Final Technical Report)

This project was proposed in response to the FY19 Bioenergy Technologies Office Multi-Topic Funding Opportunity Announcement DE-FOA-0002029, Area of Interest Subtopic 1 (AOI1): Cultivation Intensification Processes for Algae. The main challenge identified by the FOA was “in translating results between laboratory research systems and larger-scale outdoor (or mass culture) systems. These difficulties limit reliable experimental durations, adequate and representative experimental volumes of material, and results that can be reproduced reliably. By overcoming the challenge in translating results between laboratory and mass cultures, the objective of AOI 1 is to increase the harvest yield, robustness, and quality of algae cultivation for biofuels and bioproducts”. This report marks the final technical deliverable of this project and reviews all the major findings of the research program.

09 BIOMASS FUELS↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)

LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.

59 BASIC BIOLOGICAL SCIENCES↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latest Development to Establish the World Reference with Traceability to SI Units for Measuring the Atmospheric Shortwave and Longwave Irradiance

To date, Interim world reference traceable to blackbody (not sky/atmosphere) is used as a reference noted as a World Infrared Standard Group (WISG). Plan forward: to develop a reference standards traceable to SI InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. Absolute Cavity Pyrgeometer (ACP) developed by NLR is a self-calibrating radiometer using heat substitution to measure the atmospheric longwave irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

14 SOLAR ENERGY↗

Dynamic Wind Loading on Compliant, Floating PV Arrays: Cooperative Research and Development (Final Report)

PV panels are subjected to wind loads during normal outdoor operation, where th wind speed, wind direction, panel angle, and array layout play a large role in the overall loading magnitude. For floating PV systems, where panels are installed on floating rafts, these forces can lead to a dynamic displacement of the raft and mounted PV hardware. The Contractor and Participant will perform fluid-structure interaction simulations of this phenomenon for a variety of wind speeds, directions, and panel angles to characterize these forces and help design mooring/tethering lines to resist and anchor raft movement.

14 SOLAR ENERGY↗