Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear level density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Is There a Need to Revise Goals in the Management of Dyslipidemias?

Purpose of Review: Current guidelines on the management of patients with dyslipidemias recommend specific risk-dependent low-density lipoprotein cholesterol (LDL-C) treatment goals. Recently, several randomized clinical trials have investigated further lowering of LDL-C in addition to statin therapy using novel therapeutic approaches and examined their effects on cardiovascular (CV) risk. This review summarizes newly available data on efficacy and safety of lowering LDL-C beyond statin therapy and below current treatment targets. Recent Findings: In patients at very high risk for CV events, a significant residual risk remains when failing to achieve significant LDL-C reduction on maximally tolerated statin therapy alone. Further lowering of LDL-C, even beyond current treatment targets, has been shown to be safe and was associated with a further reduced CV risk reduction. The relative risk reduction per change in LDL-C levels has been observed to be consistent even in patient populations achieving extremely low levels of LDL-C. Summary: In patients at very high CV risk, further lowering of LDL-C beyond statin therapy and present treatment targets has been observed to further reduce CV risk, which may be foremost relevant for patients at a particular high absolute CV risk, e.g., for patients with progressive and/or very extensive coronary disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation and diagnostics of pulsed intense ion beams with an energy density of 10 J/cm{sup 2}

The paper presents the results of a study on transportation and focusing of a pulsed ion beam at gigawatt power level, generated by a diode with explosive-emission cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (120 ns, 200-250 kV). To reduce the beam divergence, we modified the construction of the diode. The width of the anode was increased compared to that of the cathode. We studied different configurations of planar and focusing strip diodes. It was found that the divergence of the ion beam formed by a planar strip diode, after construction modification, does not exceed 3° (half-angle). Modification to the construction of a focusing diode made it possible to reduce the beam divergence from 8° to 4°-5°, as well as to increase the energy density at the focus up to 10-12 J/cm{sup 2}, and decrease the shot to shot variation in the energy density from 10%-15% to 5%-6%. When measuring the ion beam energy density above the ablation threshold of the target material (3.5-4 J/cm{sup 2}), we used a metal mesh with 50% transparency to lower the energy density. The influence of the metal mesh on beam transport has been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

High-order finite element method for atomic structure calculations

We introduce featom, an open source code that implements a high-order finite element solver for the radial Schrödinger, Dirac, and Kohn-Sham equations. The formulation accommodates various mesh types, such as uniform or exponential, and the convergence can be systematically controlled by increasing the number and/or polynomial order of the finite element basis functions. The Dirac equation is solved using a squared Hamiltonian approach to eliminate spurious states. Here, to address the slow convergence of the $κ=±1$ states due to divergent derivatives at the origin, we incorporate known asymptotic forms into the solutions. We achieve a high level of accuracy (10 -8 Hartree) for total energies and eigenvalues of heavy atoms such as uranium in both Schrödinger and Dirac Kohn-Sham solutions. We provide detailed convergence studies and computational parameters required to attain commonly required accuracies. Finally, we compare our results with known analytic results as well as the results of other methods. In particular, we calculate benchmark results for atomic numbers (Z) from 1 to 92, verifying current benchmarks. We demonstrate significant speedup compared to the state-of-the-art shooting solver dftatom. An efficient, modular Fortran 2008 implementation, is provided under an open source, permissive license, including examples and tests, wherein particular emphasis is placed on the independence (no global variables), reusability, and generality of the individual routines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collective modes of excitation in 64 Cu

Medium and high-spin level sequences in 64 Cu were investigated using the complex 26 Mg( 48 Ca, αp5nγ ) multinucleon transfer reaction. The experiment was performed at the ATLAS accelerator facility at the Argonne National Laboratory using the Gammasphere array and the fragment mass analyzer (FMA). Two high-spin, quasirotational bands consisting of stretched-E2 transitions were observed in coincidence with the known low-spin structure for the first time. These bands share remarkable similarities with highly deformed and/or superdeformed bands observed in the A ≈ 60–70 mass region. In addition, a regular dipole sequence with weak E2 crossover transitions was observed. A general discussion of the observed structures, complemented by theoretical calculations carried out within the framework of the adiabatic and configuration-fixed constrained covariant density functional theory and the quantum particle-rotor model, are presented. Furthermore, the results are interpreted in the context of shell-structure evolution and the collectivity in the mass region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2}=0.61 (MF and MG features, p<0.01) and were partially independent of BMD. The correlations were dependent on the choice of the ROI and the texture measure. The best predictive multiregression model for failure load R{sub adj}{sup 2}=0.86 (p<0.001) included a set of recently developed texture methods (MF and SIM) but excluded bone mineral density and commonly used texture measures. Conclusions: The results suggest that texture information contained in trabecular bone structure visualized on radiographs may predict whether an implant anchorage can be used and may determine the local bone quality from preoperative radiographs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of the Idaho National Laboratory Remote Handled Low Level Waste Disposal Facility Hydraulic Performance

This document provides a summary of the expected hydraulic performance of the vault drainage system installed at Idaho National Laboratory’s Remote Handled Low-Level Waste disposal facility. Hydraulic performance was assessed through analysis of the mechanical properties of the drainage system and backfill materials, including material gradation and proctor data; laboratory data, including bulk density, porosity, unsaturated hydraulic conductivity, moisture-retention data, and van Genuchten parameters; and field-data collected using in-situ instrumentation with data collected during a vault-scale infiltration characterization test. Hydraulic performance of the vault drainage system was designed to promote a greater than 500-year vault concrete longevity. The predicted hydraulic performance is, in part, a function of the materials used in construction, sequencing of the hydraulic drainage materials, and the as-built condition of the materials following compaction necessary to ensure vault stability. Specifying specific as-built hydraulic properties is exceedingly difficult at the facility specification/design phase. Instead, material mechanical properties were specified and confirmed early during the construction process. As the drainage materials were installed, samples were sent to a laboratory for hydraulic property testing and, after drainage system installation was complete around the performance assessment vaults, a field-scale infiltration test was conducted with data collection to verify the as-built hydraulic performance. This report provides summary data for the measured mechanical properties, laboratory data, and field infiltration characterization test data. Mechanical data have relatively little variability because of the sieve system used when the materials were crushed onsite. Laboratory data were obtained for a relatively small number of material samples, but the data obtained for each sample are extensive. However, laboratory data provide the moisture retention relationships and relative hydraulic conductivity-moisture content relationships for uninstalled materials. Conducting field-scale infiltration tests with collection of moisture retention data and wetting front propagation data allows extension of laboratory data to the as-installed conditions of the vault drainage system. These combined data types are integrated using a numerical simulation of the infiltration characterization test to refine model parameters. The infiltration characterization model will be used to support the hydraulic and concrete performance of the vault system provided in the facility performance assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantum Simulations of Radiation Damage in a Molecular Polyethylene Analog

Abstract An atomic‐level understanding of radiation‐induced damage in simple polymers like polyethylene is essential for determining how these chemical changes can alter the physical and mechanical properties of important technological materials such as plastics. Ensembles of quantum simulations of radiation damage in a polyethylene analog are performed using the Density Functional Tight Binding method to help bind its radiolysis and subsequent degradation as a function of radiation dose. Chemical degradation products are categorized with a graph theory approach, and occurrence rates of unsaturated carbon bond formation, crosslinking, cycle formation, chain scission reactions, and out‐gassing products are computed. Statistical correlations between product pairs show significant correlations between chain scission reactions, unsaturated carbon bond formation, and out‐gassing products, though these correlations decrease with increasing atom recoil energy. The results present relatively simple chemical descriptors as possible indications of network rearrangements in the middle range of excitation energies. Ultimately, the work provides a computational framework for determining the coupling between nonequilibrium chemistry in polymers and potential changes to macro‐scale properties that can aid in the interpretation of future radiation damage experiments on plastic materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantum wavepacket ab initio molecular dynamics: Generalizations using an extended Lagrangian treatment of diabatic states coupled through multireference electronic structure

We present a generalization to our previously developed quantum wavepacket ab initio molecular dynamics (QWAIMD) method by using multiple diabatic electronic reduced single particle density matrices, propagated within an extended Lagrangian paradigm. The Slater determinantal wavefunctions associated with the density matrices utilized may be orthogonal or nonorthogonal with respect to each other. This generalization directly results from an analysis of the variance in electronic structure with quantum nuclear degrees of freedom. The diabatic electronic states are treated here as classical parametric variables and propagated simultaneously along with the quantum wavepacket and classical nuclei. Each electronic density matrix is constrained to be N-representable. Consequently two sets of new methods are derived: extended Lagrangian-QWAIMD (xLag-QWAIMD) and diabatic extended Lagrangian-QWAIMD (DxLag-QWAIMD). In both cases, the instantaneous potential energy surface for the quantum nuclear degrees of freedom is constructed from the diabatic states using an on-the-fly nonorthogonal multireference formalism. By introducing generalized grid-based electronic basis functions, we eliminate the basis set dependence on the quantum nucleus. Subsequent reuse of the two-electron integrals during the on-the-fly potential energy surface computation stage yields a substantial reduction in computational costs. Specifically, both xLag-QWAIMD and DxLag-QWAIMD turn out to be about two orders of magnitude faster than our previously developed time-dependent deterministic sampling implementation of QWAIMD. Energy conservation properties, accuracy of the associated potential surfaces, and vibrational properties are analyzed for a family of hydrogen bonded systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Triaxial-band structures, chirality, and magnetic rotation in La 133

The structure of 133 La has been investigated using the 116 Cd( 22 Ne,4pn) reaction and the Gammasphere array. Three new bands of quadrupole transitions and one band of dipole transitions are identified and the previously reported level scheme is revised and extended to higher spins. The observed structures are discussed using the cranked Nilsson-Strutinsky formalism, covariant density functional theory, and the particle-rotor model. Triaxial configurations are assigned to all observed bands. For the high-spin bands it is found that rotations around different axes can occur, depending on the configuration. The orientation of the angular momenta of the core and of the active particles is investigated, suggesting chiral rotation for two nearly degenerate dipole bands and magnetic rotation for one dipole band. As a result, it is shown that the h 11/2 neutron holes present in the configuration of the nearly degenerate dipole bands have significant angular momentum components not only along the long axis but also along the short axis, contributing to the balance of the angular momentum components along the short and long axes and thus giving rise to a chiral geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained in this work, when taken together with the data obtained previously for head and neck cancer, suggests that the cell surviving fractionsS{sub 2} can be reconstructed from the tumor volume variation curves measured during radiotherapy with conventional fractionation. The proposed method can be used for treatment evaluation and adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-274: Does Atmospheric Oxygen Affect the PRESAGE Dosimeter?

Purpose: To experimentally determine the influence of atmospheric oxygen on the efficiency of the PRESAGE dosimeter and its reporting system. Methods: Batches of the reporting system – a mixture of chloroform and leuchomalachite green dye – and PRESAGE were prepared in aerobic and anaerobic conditions. For anaerobic batches, samples were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses using a clinical linear accelerator. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. In addition, the concentrations of dissolved oxygen were measured using a dissolved oxygen meter. Results: The experiments revealed that oxygen has little influence on the characteristics of PRESAGE, with the radical initiator oxidizing the leucomalachite green even in the presence of oxygen. However, deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ∼ 30% when compared to the non-deoxygenated system. A slight improvement in sensitivity (∼ 5%) was also achieved by deoxygenating the PRESAGE precursor prior to casting. Measurement of the dissolved oxygen revealed low levels (0.4 ppm) in the polyurethane precursor used to fabricate the dosimeters, as compared to water (8.6 ppm). In addition, deoxygenation had no effect on the retention of the post-response absorption value of the PRESAGE dosimeter. Conclusion: The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE system. In addition, there were no observed changes in the dose linearity, absorption spectrum and post-response photofading characteristics of the PRESAGE under the conditions investigated.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study

DECT means acquiring the same object at two different energies, respectively two different tube voltages U{sub 1} and U{sub 2}. The raw data q{sub 1} and q{sub 2} undergo a decomposition process of type p=p(q{sub 1},q{sub 2}). The raw data p are reconstructed to obtain monochromatic images of the attenuation {mu}, of the object density {rho}, or of a specific material distribution. Recent advances in DECT focus on noise reduction techniques [S. Richard and J. H. Siewerdsen, Med. Phys. 35(2), 586-600 (2008)] and enable high performance DECT such as lung nodule detection [Shkumat et al., Med. Phys. 35(2), 629-632 (2008)]. Given p and a raw data-based projection-wise patient dose estimation D({alpha}) the authors determine the optimal tube current curves I{sub 1}({alpha}) and I{sub 2}({alpha}), with {alpha} being the view angle, which minimizes image noise for a given patient dose level. DEEC can perform online; I{sub 1}({alpha}) and I{sub 2}({alpha}) can be determined during the scan. Simulation studies using semianthropomorphic phantom data were carried out. In particular, functions p that generate {mu}-images and density images were evaluated. Image quality was compared to standard scans at U{sub 0}=120 kV (clinical CT) and U{sub 0}=45 kV (micro-CT) that were taken at the same dose level (D{sub 0}=D{sub 1}+D{sub 2}) and identical spatial resolution. Appropriate choice of p(q{sub 1},q{sub 2}) allows to obtain {mu}-images that show fewer artifacts and yield image noise levels comparable to the noise of the standard scan. The authors compared the standard scan to {mu}-images at 70 keV, which is the effective energy used in clinical CT, and found optimal results with {mu}-images at 25 keV for micro-CT. Nonoptimal choice of the decomposition function will, however, significantly increase image noise. In particular {mu}-images at 511 keV, as needed for PET/CT attenuation correction, exhibit more than twice as much image noise as the standard scan. With DEEC, which guarantees best dose usage possible, monochromatic images are generated with only slightly increased noise levels at the same dose compared to a standard scan. The benefit of significantly decreased artifacts appears to allow using DEEC-generated monochromatic images in daily routine. Furthermore, DEEC is not restricted to DECT and the inherent tube current modulation algorithm may also be applied to single energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pitting behavior of friction stir repair-welded 304L stainless steel in 3.5% NaCl solution at room temperature: role of grain and defect structures

Stainless steel (SS) canisters used for storing spent nuclear waste are prone to chloride-induced stress corrosion cracking. Friction stir welding (FSW), being a low heat input process, can be used for repair welding of these canisters. In this study, an artificial crack was introduced on the 304L SS coupons by an electric discharge machining process. The artificial crack was repair-welded by FSW by maintaining the tool temperature a constant at two levels (725 and 825 °C). Friction stirring significantly reduced the grain size of the stirred zone (SZ) from about 47 to 2–4 μm. The fraction of low-angle grain boundaries increased in the SZ from 2 to 37–43%. Here, on the other hand, the fraction of special grain boundaries (Σ3 and Σ9) that was ~ 50% in the base metal reduced to < 10% in the SZ. During friction stirring, the oxide layer of artificial crack was broken and aligned to form a spiral defect called lazy-S structure. All these microstructural changes affected the corrosion behavior of the FSW specimens when tested in 3.5% NaCl at room temperature using cyclic polarization, chronoamperometry, and electrochemical impedance spectroscopy. The FSW specimens showed lower polarization resistance and lower transpassive potential than those of the base metal specimens. However, the pitting protection potentials of the FSW specimens were higher than that of the base metal. The pitting behavior of the FSW specimens was influenced more by the preferential attack on the lazy-S region than by passive film breakdown. The flat band potentials of the passive film formed on the FSW specimens were more positive than that of base metal. The charge carrier density of passive film formed on the FSW specimens was higher than that of the base metal. The higher fraction of low-angle grain boundaries present in the FSW specimens could supply more number of misorientation dislocations at the metal/film interface which could form anion vacancies by a climb process leading to formation of oxide at these locations without stressing the substrate. Therefore, low-angle boundaries are considered helpful for formation of stress-free passive films that will be highly stable and enhance both pitting and stress corrosion cracking resistance.

Dry storage canister↗

Unified nonparametric equation-of-state inference from the neutron-star crust to perturbative-QCD densities

Perturbative quantum chromodynamics (pQCD), while valid only at densities exceeding those found in the cores of neutron stars, could provide constraints on the dense-matter equation of state (EOS). Here, in this work, we examine the impact of pQCD information on the inference of the EOS using a nonparametric framework based on Gaussian processes (GPs). We examine the application of pQCD constraints through a ``pQCD likelihood,'' and verify the findings of previous works; namely, a softening of the EOS at the central densities of the most massive neutron stars and a reduction in the maximum neutron-star mass. Although the pQCD likelihood can be easily integrated into existing EOS inference frameworks, this approach requires an arbitrary selection of the density at which the constraints are applied. The EOS behavior is also treated differently on either side of the chosen density. To mitigate these issues, we extend the EOS model to higher densities, thereby constructing a ``unified'' description of the EOS from the neutron-star crust to densities relevant for pQCD. In this approach the pQCD constraints effectively become part of the prior. Since the EOS is unconstrained by any calculation or data between the densities applicable to neutron stars and pQCD, we argue for maximum modeling flexibility in that regime. We compare the unified EOS with the traditional pQCD likelihood, and although we confirm the EOS softening, we do not see a reduction in the maximum neutron-star mass or any impact on macroscopic observables. Though residual model dependence cannot be ruled out, we find that pQCD suggests the speed of sound in the densest neutron-star cores has already started decreasing toward the asymptotic limit; we find that the speed of sound squared at the center of the most massive neutron star has an upper bound of $\sim 0.5$ at the 90% level.

equations of state of nuclear matter↗

MICRO/NANO-STRUCTURAL EXAMINATION AND FISSION PRODUCT IDENTIFICATION IN NEUTRON IRRADIATED AGR-1 TRISO FUEL

Advanced microscopic and microanalysis techniques were developed and applied to study irradiation effects and fission product behavior in selected low-enriched uranium oxide/uranium carbide TRISO-coated particles from fuel compacts in six capsules irradiated to burnups of 11.2 to 19.6% FIMA. Although no TRISO coating failures were detected during the irradiation, the fraction of Ag-110m retained in individual particles often varied considerably within a single compact and at the capsule level. At the capsule level Ag-110m release fractions ranged from 1.2 to 38% and within a single compact, silver release from individual particles often spanned a range that extended from 100% retention to nearly 100% release. In this paper, selected irradiated particles from Baseline, Variant 1 and Variant 3 type fueled TRISO coated particles were examined using Scanning Electron Microscopy, Atom Probe Tomography; Electron Energy Loss Spectroscopy; Precession Electron Diffraction, Transmission Electron Microscopy, Scanning Transmission Electron Microscopy (STEM), High Resolution Electron Microscopy (HRTEM) examinations and Electron Probe Micro-Analyzer. Particle selection in this study allowed for comparison of the fission product distribution with Ag retention, fuel type and irradiation level. Nano sized Ag-containing features were predominantly identified in SiC grain boundaries and/or triple points in contrast with only two sitings of Ag inside a SiC grain in two different compacts (Baseline and Variant 3 fueled compacts). STEM and HRTEM analysis showed evidence of Ag and Pd co-existence in some cases and it was found that fission product precipitates can consist of multiple or single phases. STEM analysis also showed differences in precipitate compositions between Baseline and Variant 3 fuels. A higher density of fission product precipitate clusters were identified in the SiC layer in particles from the Variant 3 compact compared with the Variant 1 compact. Trend analysis shows precipitates were randomly distributed along the perimeter of the IPyC-SiC interlayer but only weakly associated with kernel protrusion and buffer fractures. There has been no evidence that the general release of silver is related to cracks or significant degradation of the microstructure. The results presented in this paper provide new insights to Ag transport mechanism(s) in intact SiC layer of TRISO coated particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗