Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Irradiation tests in BR2 of miniature fission chambers in pulse, Campbelling and current mode

The FNDS system ('Fast Neutron Detection System') for the on-line in-pile detection of the fast neutron flux in the presence of a significant thermal neutron flux and a high gamma dose rate is being developed in the framework of the SCK.CEN-CEA Laboratoire Commun. The system has been patented in 2008. The system consists of a miniature Pu-242 fission chamber as main detector, complemented by a U-235 fission chamber or a rhodium Self-Powered Neutron Detector (SPND) for thermal neutron flux monitoring and a dedicated acquisition system that also takes care of the processing of the signals from both detectors to extract fast neutron flux data. This paper describes a FNDS qualification experiment in the SCK.CEN BR2 reactor, with experimental results on a large set of fission chambers in current and Campbelling mode. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DANCEing with the Stars: Measuring Neutron Capture on Unstable Isotopes with DANCE

Isotopes heavier than iron are known to be produced in stars through neutron capture processes. Two major processes, the slow (s) and rapid (r) processes are each responsible for 50% of the abundances of the heavy isotopes. The neutron capture cross sections of the isotopes on the s process path reveal information about the expected abundances of the elements as well as stellar conditions and dynamics. Until recently, measurements on unstable isotopes, which are most important for determining stellar temperatures and reaction flow, have not been experimentally feasible. The Detector for Advance Neutron Capture Experiments (DANCE) located at the Los Alamos Neutron Science Center (LANSCE) was designed to perform time-of-flight neutron capture measurements on unstable isotopes for nuclear astrophysics, stockpile stewardship, and reactor development. DANCE is a 4-{pi}BaF{sub 2} scintillator array which can perform measurements on sub-milligram samples of isotopes with half-lives as short as a few hundred days. These cross sections are critical for advancing our understanding of the production of the heavy isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tagged DVCS on neutron with the CLAS12 Experiment and the detector BONuS12 at Jefferson Lab (USA)

Hadronic physics studies the properties of the proton and neutron. The theory of Quantum Chromodynamics (QCD) governs the structure of hadrons. Non-perturbative structure functions are used to describe the hadrons? structure. Generalized Parton Distributions (GPDs) are a set of structure functions providing access to a 3D view of the nucleon. GPDs contain information about the longitudinal momentum and transverse position of quarks and their correlation. They are related to the spin structure and play a role in solving the proton spin puzzle. They provide access to the quarks? orbital angular momentum, a crucial puzzle piece. For this, measurements on the proton, already present, and neutron are necessary. This thesis aims to explore Compton scattering on the neutron with a deuterium target by measuring the spectator proton with the CLAS12 detector and the BONuS12 RTPC at Jefferson Lab. This work first describes the implementation, which I carried out, of a Kalman filter to reconstruct spectator protons in the BONuS12 detector. The second part of the manuscript is dedicated to the work on the analysis of DVCS on the neutron with the subtraction of background noises. Two different methods for the subtraction of ?0 will be detailed. Finally, the obtained results are presented and discussed

Ouillon, Mathieu↗

Test of the statistical model in {sup 96}Mo with the BaF{sub 2}{gamma} calorimeter DANCE array

The {gamma}-ray cascades following the {sup 95}Mo(n,{gamma}){sup 96}Mo reaction were studied with the {gamma} calorimeter DANCE (Detector for Advanced Neutron Capture Experiments) consisting of 160 BaF{sub 2} scintillation detectors at the Los Alamos Neutron Science Center. The {gamma}-ray energy spectra for different multiplicities were measured for s- and p-wave resonances below 2 keV. The shapes of these spectra were found to be in very good agreement with simulations using the DICEBOX statistical model code. The relevant model parameters used for the level density and photon strength functions were identical with those that provided the best fit of the data from a recent measurement of the thermal {sup 95}Mo(n,{gamma}){sup 96}Mo reaction with the two-step-cascade method. The reported results strongly suggest that the extreme statistical model works very well in the mass region near A=100.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification in Fission Cross Section Measurements at LANSCE

Neutron-induced fission cross sections have been measured for several isotopes of uranium and plutonium at the Los Alamos Neutron Science Center (LANSCE) over a wide range of incident neutron energies. The total uncertainties in these measurements are in the range 3–5% above 100 keV of incident neutron energy, which results from uncertainties in the target, neutron source, and detector system. The individual sources of uncertainties are assumed to be uncorrelated, however correlation in the cross section across neutron energy bins are considered. The quantification of the uncertainty contributions will be described here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Measurements Multiple HEU Metal Castings

Experiments with the standard annular highly enriched uranium (HEU) metal castings at Y-12 were performed in which up to 5 castings (~90kg) were assembled in a tightly packed array with minimal spacing between castings. The fission chain multiplication process was initiated by a time tagged 253 Cf spontaneously fissioning neutron source or time and directionally tagged neutrons from a small portable DT neutron generator and the prompt neutron time behavior measured with plastic scintillation detectors sensitive the fast neutron (>1 MeV) and gamma ray without distinction. These experiments were performed to provide data to benchmark methods for the calculation of the prompt neutron time behavior. Previous measurements with a single casting have been reported. This paper presents the experimental results for multiple castings. The prompt time decay was obtained by time coincidence correlation measurements between the detectors and the time tagged neutron source emission (equivalent to randomly pulsed neutron measurements) and between pairs of plastic scintillation detectors (equivalent to a 2-detector Rossi-alpha measurement). These standard HEU storage castings at the Y-12 plant had 5.000-in-OD, 3.500-in-ID, masses between 17,636 and 17,996 g, impurity content of 992 ppm, density of 18.75 g/cm 3 and average enrichment of 93.16 wt % 235 U. The castings were in tight fitting 025-in.-thick, 8.0-in-high stainless steel (SS-304) cylindrical cans for contamination control which were 8.0 in high. One can had an inside diameter of 3.0 in so that the Cf source could be located on the axes of this casting. Four 1 x 1 x 6 in plastic scintillators with the long dimension perpendicular to axes of the castings and adjacent to the outer surface of the casting cans were used. The detectors were enclosed in 1/4.-in.-thick lead shields on four 1 x 6 surfaces and on the 1 x 1 surface. The small surface of the lead shield was adjacent to the steel table. The photograph of the assembly of 5 casting with the detectors is given in Figure 1. The DT generator can be seen in the back with the time tagged neutrons aligned symmetrically around a line drawn from the generator through target spot and the center of the casting in the annular can seen in the foreground.

36 MATERIALS SCIENCE↗

Spin and Parity Assignment of Neutron Resonances using Gamma-ray Multiplicity

Decay gamma rays following neutron capture on various isotopes are collected by the Detector for Advanced Neutron Capture Experiments (DANCE) array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation (160 detectors) and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a given isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. The multiplicity distribution contains the signatures of spin and parity of the capture state. Under suitable circumstances where the difference between spins of the initial (capture) and final (ground) state is large enough, the signatures in the multiplicity distribution can be used in improving the spin assignment of the initial state. The spin assignment is applied with varying degree of success to difference isotopes and description of this application for {sup 95}Mo, {sup 151,153}Eu, and {sup 155,157}Gd is reviewed briefly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Neutron Reaction Cross Sections in Carbon using a Single Crystal Diamond Detector

A single crystal diamond detector was exposed to the quasi mono-energetic neutron fields in the energy range from 7 MeV to 20.5 MeV produced by the Van de Graaff neutron generator of the EC-JRC-IRMM. Pulse Height Spectra (PHS) of the neutron interaction with the diamond (carbon) were recorded in order to derive the experimental response function of this detector to neutrons in view of its use as a compact fast neutron spectrometer. Several peaks produced by outgoing charged particles produced when neutrons interact with carbon were identified using the reaction Q-values. The corresponding nuclear reactions, such as (n,{alpha}), (n,p), (n,d) for different excitation states were identified in the PHS. The analysis of the peaks allows the derivation of some neutron reaction cross sections in carbon. The results are presented in this paper together with the associated uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-induced fission measurements at the DANCE and LSDS facilities at LANL

New results from neutron-induced fission measurements performed at the Detector for Advanced Neutron Capture Experiments (DANCE) and Lead Slowing Down Spectrometer (LSDS) are presented. New correlated data on prompt-fission γ-ray (PFG) distributions were measured using the DANCE array for resonant neutron-induced fission of 233 U, 235 U and 239 Pu. The deduced properties of PFG emission are presented using a simple parametrization. An accurate knowledge of fission γ-ray spectra enables us to analyze the isomeric states of 236 U created after neutron capture on 235 U. We briefly discuss these new results. Finally, we review details and preliminary results of the challenging 237 U(n,f) cross section measurement at the LSDS facility.

233U↗

Delivery of LiH Shell for DANCE

Material for a new LiH shell for neutron shielding has been obtained for the Detector for Advanced Neutron Capture Experiments. This is a critical component for optimizing sensitivity of neutron capture experiments performed in support of Office of Experimental Sciences mission, particularly in the case of small, rare samples.

42 ENGINEERING↗

Low-background EN-detector for the investigation of the neutron component of EASs

Thermal neutrons are detected using a scintillator compound based on ZnS(Ag) with B{sub 2}O{sub 3} added to it. The pulse height generated by single charged particles in a scintillator of small thickness (50 mg/cm{sup 2}) is not larger than that of a noise signal due to a low sensitivity to single charged particles. As a result, the detector satisfies the requirements of a low-background one in the context of cosmic-ray experiments. The detector is to be used for neutron detection in extensive air showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new Recoil Proton Telescope for energy and fluence measurement of fast neutron fields

The spectrometer ATHENA (Accurate Telescope for High Energy Neutron metrology Applications), is being developed at the IRSN / LMDN (Institut de Radioprotection et de Surete nucleaire / Laboratoire de Metrologie et de dosimetrie des neutrons) and aims at characterizing energy and fluence of fast neutron fields. The detector is a Recoil Proton Telescope and measures neutron fields in the range of 5 to 20 MeV. This telescope is intended to become a primary standard for both energy and fluence measurements. The neutron detection is achieved by a polyethylene radiator for n-p conversion, three 50{sub m} thick silicon sensors that use CMOS technology for the proton tracking and a 3 mm thick silicon diode to measure the residual proton energy. This first prototype used CMOS sensors called MIMOSTAR, initially developed for heavy ion physics. The use of CMOS sensors and silicon diode increases the intrinsic efficiency of the detector by a factor of ten compared with conventional designs. The first prototype has already been done and was a successful study giving the results it offered in terms of energy and fluence measurements. For mono energetic beams going from 5 to 19 MeV, the telescope offered an energy resolution between 5 and 11% and fluence difference going from 5 to 7% compared to other home standards. A second and final prototype of the detector is being designed. It will hold upgraded CMOS sensors called FastPixN. These CMOS sensors are supposed to run 400 times faster than the older version and therefore give the telescope the ability to support neutron flux in the order of 107 to 108cm{sup 2}:s{sup 1}. The first prototypes results showed that a 50 m pixel size is enough for a precise scattering angle reconstruction. Simulations using MCNPX and GEANT4 are already in place for further improvements. A DeltaE diode will replace the third CMOS sensor and will be installed right before the silicon diode for a better recoil proton selection. The final prototype with its new geometry will increase the telescopes efficiency by a factor of 1.5. It will also cover some of the most important points in metrology; repeatability, reproducibility and sustainability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of D-T Neutron Source Flux by SelfNeutron Activation Analysis with a LaBr3 Detector

Conclusions: • Decay of 78Br produced from the 79Br(n,2n) reaction in LaBr3 is present in the spectrum plotted in the time domain. • The neutron production rate reconstructed from preliminary LaBr3 estimate is smaller than the generator output. • Generator characterization may become more routine if a simple and robust method is made available for applications. Ongoing work: • Implementing bootstrapping to improve error estimates. • Examining threshold and edge effects of LaBr3

SMITH, MURRY↗

Determining plutonium mass in spent fuel using Cf-252 interrogation with prompt neutron detection

{sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection is proposed as one of 14 NDA techniques to determine Pu mass in spent fuel assemblies (FAs). CIPN is a low-cost and portable instrument, and it looks like a modified fork detector combined with an active interrogation source. Fission chamber (FC) is chosen as neutron detector because of its insensitivity to {gamma} radiation. The CIPN assay is comprised of two measurements, a background count and an active count, without and with the {sup 252}Cf source next to the fuel respectively. The net signal above background is primarily due to the multiplication of Cf source neutrons caused by the fissile content. The capability of CIPN to detect diversion and to determine fissile content was quantified using MCNPX simulations. New schemes were proposed (such as burnup and cooling time correction, etc.) and the results show that the fissile content of a target spent fuel assembly can be determined using CIPN signal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Cross Section Measurement In The Protodune-SP Experiment

Understanding the detector response to neutrons will be critical for performing neutrino oscillation analyses in the next-generation Deep Underground Neutrino Experiment (DUNE). The DUNE physics program is centered around measuring the neutrino flavor composition as a function of their energy both at the near and the far detector. Neutrinos in the DUNE beam will have energies ranging between 100~MeV and 10~GeV, which is significant, because individual neutrino energies will not be known beforehand and will have to be reconstructed. Neutrino interactions in DUNE will produce leptons and hadrons -- including protons, pions, and neutrons. Neutrons can transport energy away from their origin and sometimes go undetected. In addition to the primary neutrons produced by the neutrino, subsequent interactions of the charged hadrons can result in secondary neutrons. Neutrons are a source of missing energy and will bias the neutrino energy measurement. Currently, there is also a 20\% energy scale uncertainty and a 40\% uncertainty on the energy resolution for neutrons in DUNE, which must be addressed. ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton prototype for the DUNE far detector and was designed to both validate the technology that will be employed in DUNE and to measure cross sections for the charged hadrons (pions, protons, and kaons) at the relevant energies for DUNE. The ProtoDUNE-SP experiment, therefore, is in a unique position to characterize the secondary neutron component for DUNE. This is achieved by searching for candidate neutron interactions in ProtoDUNE-SP events and using these to facilitate a measurement of the neutron inelastic cross section as well as an estimate of the neutron energy and number. The cross section measurement presented here is based on neutrons produced in 1~GeV, $\pi^+$ events captured in 2018 by ProtoDUNE-SP in accordance with the production and cross section models in the GEANT4 simulation toolkit, version 4.1 0.6p1. T he best-fit neutron inelastic cross section, in the kinetic energy range of 114 to 314~MeV, is $1.24_{-0.08}^{+0.10}$~(stat.~$\oplus$~syst.)~barns.

Rivera, David Orlando↗