Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Diagnostic of fusion neutrons on JET tokamak using diamond detector

In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of intensity modulated neutron radiotherapy (IMNRT)

Purpose: Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center/Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. Methods: IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. Results: While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate/five head and neck) agreed to within -0.8 {+-} 1.4% and 5.0 {+-} 6.0% within and outside the target, respectively. Nearly all (22/24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)/prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and/or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. Conclusions: IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

60 APPLIED LIFE SCIENCES↗

Event Centroiding Applied to Energy-Resolved Neutron Imaging at LANSCE

The energy-dependence of the neutron cross section provides vastly different contrast mechanisms than polychromatic neutron radiography if neutron energies can be selected for imaging applications. In recent years, energy-resolved neutron imaging (ERNI) with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as for quantitative density measurements, was pioneered at the Flight Path 5 beam line at LANSCE and continues to be refined. In this work, we present event centroiding, i.e., the determination of the center-of-gravity of a detection event on an imaging detector to allow sub-pixel spatial resolution and apply it to the many frames collected for energy-resolved neutron imaging at a pulsed neutron source. While event centroiding was demonstrated at thermal neutron sources, it has not been applied to energy-resolved neutron imaging, where the energy resolution requires to be preserved, and we present a quantification of the possible resolution as a function of neutron energy. For the 55 μm pixel size of the detector used for this study, we found a resolution improvement from ~80 μm to ~22 μm using pixel centroiding while fully preserving the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chi-Nu measurements of the prompt fission neutron spectrum of {sup 235}U and {sup 239}Pu - 25581

Knowledge of the prompt fission neutron spectrum is crucial for understanding the behavior of energetic nuclear systems. Although this energy spectrum has been measured for the major actinides {sup 235}U and {sup 239}Pu for decades, the majority of the available literature data lack the coverage of both incident and outgoing neutron energies and the precision required to accurately guide evaluations and fission models. The Chi-Nu experiment is designed to measure the prompt fission neutron spectrum for a wide range of incident and outgoing neutron energies with attention to uncertainty estimation and assessment of systematic errors in order to provide reliable guidance for evaluations and models of nuclear fission. Preliminary results of the prompt fission neutron spectrum from the neutron-induced fission of {sup 235}U and {sup 239}Pu are presented here, with a focus on the presence of spectral features near multi-chance fission thresholds, pre-equilibrium neutrons in the deduced spectrum, and also on trends of the mean fission neutron energy as a function of the incident neutron energy. While the mean energies of from ENDF/B-VIII.0 are in good agreement with those reported for {sup 235}U spectra, significant disagreements exist above an incident neutron energy of approximately 13 MeV for {sup 239}Pu. Furthermore, in general, the physics features regarding multi-chance fission and pre-equilibrium neutron emission newly-introduced into ENDF/B-VIII.0 appear provide an improved description of the data as compared to ENDF/B-VII.1. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron production in lunar habitats - Paper 132

Lunar habitats constructed of either local materials or conventional materials used for spacecraft (such as aluminum) will provide protection for astronauts from solar energetic particles (SEP) and galactic cosmic rays (GCR). Although there are essentially no neutrons in the primary GCR and SEP fields, neutrons are produced by interactions of those fields with the lunar surface and with the lunar habitat. In a habitat, the neutrons can be divided into two categories: albedo neutrons moving generally upward through the habitat, and a generally downward flux created by interactions in the habitat walls. These two neutron fields differ in their energy spectrum, and as a result different mitigation strategies may be needed for different areas of the habitat in order to reduce the dose from neutrons. In this work, we calculate the 'upward' and 'downward' neutron fluences, using a variety of shielding materials and thicknesses. We also investigate the effect of other materials inside the habitat on the neutron fluences. The preliminary transport model calculations performed here verify the effectiveness of a hydrogenous shielding wall material, polyethylene, in reducing the neutron dose inside a simple lunar habitat geometry when compared to walls made of lunar regolith and aluminum. Separate transport model calculations were done for the albedo neutron spectrum rising up from the lunar soil and for GCR particles incident upon the habitat shielding. In the case of GCR ions incident on the habitat, shielding wall made of polyethylene reduced the neutron effective dose by a factor of three, compared to the other two shielding materials. (authors)

36 MATERIALS SCIENCE↗

Improvements to neutron detection of Pu in solvent for an aqueous buffer tank, magnox reprocessing plant, Sellafield - 14216

The PP Active Feed Tank (PPAFT) is a buffer tank that is not safe by geometry and which is located between the Medium Active (MA) and Plutonium Purification (PP) cycles of the chemical separation process in the Magnox Reprocessing Plant. The PPAFT receives Pu nitrate in acid which has been conditioned ready for the extraction of Pu with TBP/OK (tri-butyl phosphate in kerosene) solvent in the PP Cycle. The criticality safety case for the PPAFT recognises that during both normal operations and potential maloperations solvent which is dissolved (TBP which is present in solution but can be released upon a change in acidity) and entrained (TBP/OK physically carried over but not in solution) will accumulate in the PPAFT. The only practicable route out for Pu in solvent in the PPAFT is the normal process route out from the base of the PPAFT to the PP cycle through intermediate vacuum lift and feed vessels. However, the dished end base of the PPAFT and the intermediate vacuum lift and feed vessels are of particularly challenging geometry. There are five neutron monitors placed around the PPAFT for the detection of Pu in solvent. The original design intent of the neutron detection system was that any single monitor should be able to reveal an accumulation of Pu in solvent before it would potentially be unsafe if fed downstream. However, over time there have been changes to the fuel feed and chemical process of the plant which have had the potential to affect the performance of the neutron monitoring system. The ability of the neutron monitoring system to function to its original intent was questioned. Work has recently been carried out to investigate the capabilities of the PPAFT neutron monitoring system for current plant conditions and to identify potential improvements while making best use of the existing neutron monitors. It was found that moving a neutron monitor from the side to the top of the PPAFT and adding alarms based on the ratio of signals from multiple neutron detectors would be effective in improving detection of Pu in solvent. This paper describes the challenges involved in detecting thin layers of Pu in solvent using neutron monitors, discusses the improvements made to the PPAFT neutron monitors and details the combination of real plant data and modelling with the shielding code MCBEND used to provide confidence in the enhanced neutron monitoring system. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

Physical particularities of nuclear reactors using heavy moderators of neutrons

In nuclear reactors, thermal neutron spectra are formed using moderators with small atomic weights. For fast reactors, inserting such moderators in the core may create problems since they efficiently decelerate the neutrons. In order to form an intermediate neutron spectrum, it is preferable to employ neutron moderators with sufficiently large atomic weights, using {sup 233}U as a fissile nuclide and {sup 232}Th and {sup 231}Pa as fertile ones. The aim of the work is to investigate the properties of heavy neutron moderators and to assess their advantages. The analysis employs the JENDL-4.0 nuclear data library and the SCALE program package for simulating the variation of fuel composition caused by irradiation in the reactor. The following main results are obtained. By using heavy moderators with small neutron moderation steps, one is able to (1) increase the rate of resonance capture, so that the amount of fertile material in the fuel may be reduced while maintaining the breeding factor of the core; (2) use the vacant space for improving the fuel-element properties by adding inert, strong, and thermally conductive materials and by implementing dispersive fuel elements in which the fissile material is self-replenished and neutron multiplication remains stable during the process of fuel burnup; and (3) employ mixtures of different fertile materials with resonance capture cross sections in order to increase the resonance-lattice density and the probability of resonance neutron capture leading to formation of fissile material. The general conclusion is that, by forming an intermediate neutron spectrum with heavy neutron moderators, one can use the fuel more efficiently and improve nuclear safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials. Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., 235 U or 233 U) fraction, such as highly enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the “primary” delayed neutrons (emitted directly by fission fragments) and the “secondary prompt” fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from “primary” delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. Here, we demonstrate two experimental approaches for discriminating between 235 U and 238 U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

07 ISOTOPE AND RADIATION SOURCES↗

New physics at a neutron beam dump

We find a new utility of neutrons, usually treated as an experimental nuisance causing unwanted background, in probing new physics signals. The new physics signals can either be radiated from neutrons (neutron bremsstrahlung) or appear through secondary particles from neutron-on-target interactions, dubbed “neutron beam dump.” As a concrete example, we take the FASER/FASER2 experiment as a “factory” of high-energy neutrons that interact with the iron dump. We find that if new physics particles had the same interaction strength to protons and neutrons, their production rate via neutron-initiated bremsstrahlung would be comparable to that via proton-initiated ones, in terms of the resulting flux and the range of couplings that can be probed. The neutron bremsstrahlung can be used, for instance, to probe dark gauge bosons with nonzero neutron coupling. In particular, we investigate protophobic gauge bosons and find that FASER/FASER2 can probe new parameter space. We also illustrate the possibility of neutron-induced secondary particles by considering axionlike particles with electron couplings. We conclude that the physics potential of FASER/FASER2 in terms of new physics searches can be greatly extended and improved with the inclusion of neutron interactions. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-Messenger Observations of Neutron Rich Matter

At very high densities, electrons react with protons to form neutron rich matter. This material is central to many fundamental questions in nuclear physics and astrophysics. Moreover, neutron rich matter is being studied with an extraordinary variety of new tools such as the Facility for Rare Isotope Beams (FRIB) and the Laser Interferometer Gravitational Wave Observatory (LIGO). We describe the Lead Radius Experiment (PREX) that uses parity violating electron scattering to measure the neutron radius in 208Pb. This has important implications for neutron stars and their crusts. We discuss X-ray observations of neutron star radii. These also have important implications for neutron rich matter. Gravitational waves (GW) open a new window on neutron rich matter. They come from sources such as neutron star mergers, rotating neutron star mountains, and collective r-mode oscillations. Using large scale molecular dynamics simulations, we find neutron star crust to be very strong. It can support mountains on rotating neutron stars large enough to generate detectable gravitational waves. We believe that combing astronomical observations using photons, GW, and neutrinos, with laboratory experiments on nuclei, heavy ion collisions, and radioactive beams will fundamentally advance our knowledge of compact objects in the heavens, the dense phases of QCD, the origin of the elements, and of neutron rich matter.

Horowitz, C. J.↗

Improved Delayed-Neutron Spectroscopy Using Trapped Ions

The neutrons emitted following the β decay of fission fragments (known as delayed neutrons because they are emitted after fission on a timescale of the β-decay half-lives) play a crucial role in reactor performance and control. Reviews of delayed-neutron properties highlight the need for high-quality data for a wide variety of delayed-neutron emitters to better understand the time dependence and energy spectrum of the neutrons as these properties are essential for a detailed understanding of reactor kinetics needed for reactor safety and to understand the behavior of these reactors under various accident and component-failure scenarios. For fast breeder reactors, criticality calculations require accurate delayed-neutron energy spectra and approximations that are acceptable for light-water reactors such as assuming the delayed-neutron and fission-neutron energy spectra are identical are not acceptable and improved β-delayed neutron data is needed for safety and accident analyses for these reactors. With improved nuclear data, the delayed neutrons flux and energy spectrum could be calculated from the contributions from individual isotopes and therefore could be accurately modeled for any fuel-cycle concept, actinide mix, or irradiation history. High-quality β-delayed neutron measurements are also critical to constrain modern nuclear-structure calculations and empirical models that predict the decay properties for nuclei for which no data exists and improve the accuracy and flexibility of the existing empirical descriptions of delayed neutrons from fission such as the six-group representation

74 ATOMIC AND MOLECULAR PHYSICS↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗