Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Shipping Anomaly from NMIS Imaging

In 2007, a shipping container that arrived at ORNL was imaged using the neutron and gamma ray imaging capability of Nuclear Materials Identification System (NMIS). NMIS with imaging uses a time-tagged radiation source, which can be either a DT neutron generator or a 252Cf spontaneous fission source. The initial imaging measurements used the DT generator s 14.1 MeV neutrons. Because of the low attenuation of the container and its contents, subsequent measurements were performed with the fission energy spectrum neutrons and gamma rays of the 252Cf source. The 252Cf source provides a simultaneous measurement of both a neutron (more sensitive to organics) and a gamma ray (more sensitive to steels) image to be obtained. The images showed that the container contents were partially inverted instead of their expected arrangement. This information was useful in assessing the shipment packaging before the container was opened and indicates how NMIS with imaging can be used to image receipts.

36 MATERIALS SCIENCE↗

Neutron Radiography and Fission Mapping Measurements of Nuclear Materials with Varying Composition and Shielding

Neutron radiography and fission mapping measurements were performed on four measurement objects with varying composition and shielding arrangements at the Idaho National Laboratory's Zero Power Physics Reactor (ZPPR) facility. The measurement objects were assembled with ZPPR reactor plate materials comprising plutonium, natural uranium, or highly enriched uranium and were presented as unknowns for characterization. As a part of the characterization, neutron radiography was performed using a deuterium-tritium (D-T) neutron generator as a source of time and directionally tagged 14 MeV neutrons. The neutrons were detected by plastic scintillators placed on the opposite side of the object, using the time-correlation-based data acquisition of the Nuclear Materials Identification System developed at Oak Ridge National Laboratory. Each object was measured at several rotations with respect to the neutron source to obtain a tomographic reconstruction of the object and a limited identification of materials via measurement of the neutron attenuation. Large area liquid scintillators with pulse shape discrimination were used to detect the induced fission neutrons. A fission site map reconstruction was produced by time correlating the induced fission neutrons with each tagged neutron from the D-T neutron generator. This paper describes the experimental configuration, the ZPPR measurement objects used, and the neutron imaging and fission mapping results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CF Neutron Time of Flight Transmission for Material Identification for weapons Trainers

The neutron transmission, elastic scattering, and non-elastic reactions can be used to distinguish various isotopes. Neutron transmission as a function of energy can be used in some cases to identify materials in unknown objects. A time tagged californium source that provides a fission spectrum of neutrons is a useful source for neutron time-of-flight (TOF) transmission measurements. Many nuclear weapons trainer units for a particular weapons system (no fissile, but of same weight and center of gravity) in shipping containers were returned to the National Nuclear Security Administration Y-12 National Security Complex in the mid 1990s. Nuclear Materials Identification System (NMIS) measurements with a time tagged californium neutron source were used to verify that these trainers did not contain fissile material. In these blind tests, the time distributions of neutrons through the containers were measured as a function of position to locate the approximate center of the trainer in the container. Measurements were also performed with an empty container. TOF template matching measurements were then performed at this location for a large number of units. In these measurements, the californium source was located on one end of the container and a proton recoil scintillator was located on the other end. The variations in the TOF transmission for times corresponding to 1 to 5 MeV were significantly larger than statistical. Further examination of the time distribution or the energy dependence revealed that these variations corresponded to the variations in the neutron cross section of aluminum averaged over the energy resolution of the californium TOF measurement with a flight path of about 90 cm. Measurements using different thicknesses of aluminum were also performed with the source and detector separated the same distance as for the trainer measurements. These comparison measurements confirmed that the material in the trainers was aluminum, and the total thickness of aluminum through the trainers was determined. This is an example of how californium transmission TOF measurements can be used to identify materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the Chromium Resonance Parameters Including Resonance Parameter Covariance

The intent of this work is to report the results and describe the procedures utilized to evaluate the chromium isotopes' cross sections, i.e., (50)Cr, (52)Cr, (53)Cr, and (54)Cr, for criticality safety applications. The evaluations were done in the resolved resonance region using the reduced Reich-Moore R-matrix formalism. The novel aspect of this evaluation is the inclusion of new transmission and capture cross-section measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) for energies below 100 keV and the extension of the (53)Cr energy region. The resonance analysis was performed with the multilevel R-matrix code, SAMMY, which utilizes the generalized least-squares technique based on the Bayes' theory. Complete sets of resonance parameters and resonance parameter covariance matrices (RPCMs) were obtained for each of the chromium isotopes from the SAMMY analysis of the experimental database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fieldable Nuclear Material Identification System

The Fieldable Nuclear Material Identification System (FNMIS), funded by the NA-241 Office of Dismantlement and Transparency, provides information to determine the material attributes and identity of heavily shielded nuclear objects. This information will provide future treaty participants with verifiable information required by the treaty regime. The neutron interrogation technology uses a combination of information from induced fission neutron radiation and transmitted neutron imaging information to provide high confidence that the shielded item is consistent with the host's declaration. The combination of material identification information and the shape and configuration of the item are very difficult to spoof. When used at various points in the warhead dismantlement sequence, the information complimented by tags and seals can be used to track subassembly and piece part information as the disassembly occurs. The neutron transmission imaging has been developed during the last seven years and the signature analysis over the last several decades. The FNMIS is the culmination of the effort to put the technology in a usable configuration for potential treaty verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Spent Fuel Assay with a Lead Slowing Down Spectrometer

Assay of fissile materials in spent fuel that are produced or depleted during the operation of a reactor, is of paramount importance to nuclear materials accounting, verification of the reactor operation history, as well as for criticality considerations for storage. In order to prevent future proliferation following the spread of nuclear energy, we must develop accurate methods to assay large quantities of nuclear fuels. We analyze the potential of using a Lead Slowing Down Spectrometer for assaying spent fuel. We conclude that it is possible to design a system that will provide around 1% statistical precision in the determination of the 239 Pu, 241 Pu and 235 U concentrations in a PWR spent-fuel assembly, for intermediate-to-high burnup levels, using commercial neutron sources, and a system of 238 U threshold fission detectors. Pending further analysis of systematic errors, it is possible that missing pins can be detected, as can asymmetry in the fuel bundle.

07 ISOTOPE AND RADIATION SOURCES↗

Acceleration of Monte Carlo Criticality Calculations Using Deterministic-Based Starting Sources

A new automatic approach that uses approximate deterministic solutions for providing the starting fission source for Monte Carlo eigenvalue calculations was evaluated in this analysis. By accelerating the Monte Carlo source convergence and decreasing the number of cycles that has to be skipped before the tally's estimation, this approach was found to increase the efficiency of the overall simulation, even with the inclusion of the extra computational time required by the deterministic calculation. This approach was also found to increase the reliability of the Monte Carlo criticality calculations of loosely coupled systems because the use of the better starting source reduces the likelihood of producing an undersampled k eff due to the inadequate source convergence. The efficiency improvement was demonstrated using two of the standard test problems devised by the OECD/NEA Expert Group on Source Convergence in Criticality-Safety Analysis to measure the source convergence in Monte Carlo criticality calculations. For a fixed uncertainty objective, this approach increased the efficiency of the overall simulation by factors between 1.2 and 3 depending on the difficulty of the source convergence in these problems. The reliability improvement was demonstrated in a modified version of the 'k eff of the world' problem that was specifically designed to demonstrate the limitations of the current Monte Carlo power iteration techniques. For this problem, the probability of obtaining a clearly undersampled k eff decreased from 5% with a uniform starting source to zero with a deterministic starting source when batch sizes with more than 15,000 neutron/cycle were used.

42 ENGINEERING↗

Enhancements in SCALE 6.1

The SCALE code system developed at Oak Ridge National Laboratory provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a 'plug-and-play' framework with 89 computational modules, including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE's graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.1 builds on the existing capabilities and ease-of-use of SCALE and provides several new features such as enhanced lattice physics capabilities and multigroup Monte Carlo depletion, improved options and capabilities for sensitivity and uncertainty analysis calculations, improved flexibility in shielding and criticality accident alarm system calculations with automated variance reduction, and new options for the definition of group structures for depletion calculations. The SCALE 6.1 development team has focused on improved robustness via substantial additional regression testing and verification for new and existing features, providing improved performance relative to SCALE 6.0, especially in reactor physics calculations and in the nuclear data used for source term characterization and shielding calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Statistical Sampling Method for Uncertainty Analysis with SCALE

A new statistical sampling sequence called Sampler has been developed for the SCALE code system. Random values for the input multigroup cross sections are determined by using the XSUSA program to sample uncertainty data provided in the SCALE covariance library. Using these samples, Sampler computes perturbed self-shielded cross sections and propagates the perturbed nuclear data through any specified SCALE analysis sequence, including those for criticality safety, lattice physics with depletion, and shielding calculations. Statistical analysis of the output distributions provides uncertainties and correlations in the desired responses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Packaging Certification program Methodology for Determining Dose Rates for Small Gram Quantities in Shipping Packagings

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels within the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.

42 ENGINEERING↗

Benchmark On Sensitivity Calculation (Phase III)

The sensitivities of the keff eigenvalue to neutron cross sections have become commonly used in similarity studies and as part of the validation algorithm for criticality safety assessments. To test calculations of the sensitivity coefficients, a benchmark study (Phase III) has been established by the OECD-NEA/WPNCS/EG UACSA (Expert Group on Uncertainty Analysis for Criticality Safety Assessment). This paper presents some sensitivity results generated by the benchmark participants using various computational tools based upon different computational methods: SCALE/TSUNAMI-3D and -1D, MONK, APOLLO2-MORET 5, DRAGON-SUSD3D and MMKKENO. The study demonstrates the performance of the tools. It also illustrates how model simplifications impact the sensitivity results and demonstrates the importance of 'implicit' (self-shielding) sensitivities. This work has been a useful step towards verification of the existing and developed sensitivity analysis methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BFS, a Legacy to the International Reactor Physics, Criticality Safety, and Nuclear Data Communities

Two Organization for Economic Cooperation and Development (OECD) Nuclear Energy Agency (NEA) programs, the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and the International Reactor Physics Experiment Evaluation Project (IRPhEP) have been identifying existing integral experiment data, evaluating those data, and providing integral benchmark specifications for methods and data validation for nearly two decades. The Russian Federation, IPPE, and the BFS laboratories have made substantial contributions to those two projects. Contributions from the BFS facilities are highlighted in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of HEU Measurements Using Measured and Simulated Data [Slides]

Correlated neutron data analyzed using the Feynman Variance-to-Mean method can be used to assess the multiplication and mass of special nuclear material (SNM) systems. After list-mode data are acquired, the multiplication and mass can be determined using detector parameters. This work compares data sets that were measured to simulated data using recent MCNP list-mode modifications. In addition, both sets of data are analyzed using both measured and simulated parameters to infer the system multiplication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Criticality Safety Validation of SCALE 6.1 with ENDF/B-VII.0 Libraries

ANSI/ANS-8.1-1998;2007, Nuclear Criticality Safety in Operations with Fissionable Material Outside Reactors, and ANSI/ANS-8.24-2007, Validation of Neutron Transport Methods for Nuclear Criticality Safety Calculations, require validation of a computer code and the associated data through benchmark evaluations based on physical experiments. The performance of the code and data are validated by comparing the calculated and the benchmark results. A SCALE procedure has been established to generate a Verified, Archived Library of Inputs and Data (VALID). This procedure provides a framework for preparing, peer reviewing, and controlling models and data sets derived from benchmark definitions so that the models and data can be used with confidence. The procedure ensures that the models and data were correctly generated using appropriate references with documented checks and reviews. Configuration management is implemented to prevent inadvertent modification of the models and data or inclusion of models that have not been subjected to the rigorous review process. VALID entries for criticality safety are based on critical experiments documented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). The findings of a criticality safety validation of SCALE 6.1 utilizing the benchmark models vetted in the VALID library at Oak Ridge National Laboratory are summarized here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Examination of Validation Outlier Cases Using the Sensitivity and Uncertainty Analysis Tools of SCALE 6.1

In the course of criticality code validation, outlier cases are frequently encountered. Historically, the causes of these unexpected results could be diagnosed only through comparison with other similar cases or through the known presence of a unique component of the critical experiment. The sensitivity and uncertainty (S/U) analysis tools available in the SCALE 6.1 code system provide a much broader range of options to examine underlying causes of outlier cases. This paper presents some case studies performed as a part of the recent validation of the KENO codes in SCALE 6.1 using S/U tools to examine potential causes of biases.

97 MATHEMATICS AND COMPUTING↗

Impact of Fuel Failure on Criticality Safety of Used Nuclear Fuel

Commercial used nuclear fuel (UNF) in the United States is expected to remain in storage for considerably longer periods than originally intended (e.g., <40 years). Extended storage (ES) time and irradiation of nuclear fuel to high-burnup values (>45 GWd/t) may increase the potential for fuel failure during normal and accident conditions involving storage and transportation. Fuel failure, depending on the severity, can result in changes to the geometric configuration of the fuel, which has safety and regulatory implications. The likelihood and extent of fuel reconfiguration and its impact on the safety of the UNF is not well understood. The objective of this work is to assess and quantify the impact of fuel reconfiguration due to fuel failure on criticality safety of UNF in storage and transportation casks. This effort is primarily motivated by concerns related to the potential for fuel degradation during ES periods and transportation following ES. The criticality analyses consider representative UNF designs and cask systems and a range of fuel enrichments, burnups, and cooling times. The various failed-fuel configurations considered are designed to bound the anticipated effects of individual rod and general cladding failure, fuel rod deformation, loss of neutron absorber materials, degradation of canister internals, and gross assembly failure. The results quantify the potential impact on criticality safety associated with fuel reconfiguration and may be used to guide future research, design, and regulatory activities. Although it can be concluded that the criticality safety impacts of fuel reconfiguration during transportation subsequent to ES are manageable, the results indicate that certain configurations can result in a large increase in the effective neutron multiplication factor, k eff . Future work to inform decision making relative to which configurations are credible, and therefore need to be considered in a safety evaluation, is recommended.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing (Validating?) Cross Sections with ICSBEP Benchmarks [Slides]

We discuss how to use critical benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments to determine the applicability of specific cross sections to the end-user's problem of interest. Particular attention is paid to making sure the selected suite of benchmarks includes the user's range of applicability (ROA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods for Detector Placement and Analysis of Criticality Accident Alarm Systems

Determining the optimum placement to minimize the number of detectors for a criticality accident alarm system (CAAS) in a large manufacturing facility is a complex problem. There is typically a target for the number of detectors that can be used over a given zone of the facility. A study to optimize detector placement typically begins with some initial guess at the placement of the detectors and is followed by either predictive calculations of accidents at specific locations or adjoint calculations based on preferred detector locations. Within an area of a facility, there may be a large number of potential criticality accident sites. For any given placement of the detectors, the list of accident sites can be reduced to a smaller number of locations at which accidents may be difficult for detectors to detect. Developing the initial detector placement and determining the list of difficult accident locations are both based on the practitioner's experience. Simulations following fission particles released from an accident location are called 'forward calculations.' These calculations can be used to answer the question 'where would an alarm be triggered?' by an accident at a specified location. Conversely, 'adjoint calculations' start at a detector site using the detector response function as a source and essentially run in reverse. These calculations can be used to answer the question 'where would an accident be detected?' by a specified detector location. If the number of accidents, P, is much less than the number of detectors, Q, then forward simulations may be more convenient and less time-consuming. If Q is large or the detectors are not placed yet, then a mesh tally of dose observed by a detector at any location must be computed over the entire zone. If Q is much less than P, then adjoint calculations may be more efficient. Adjoint calculations employing a mesh tally can be even more advantageous because they do not rely on a list of specific difficult-to-detect accident sites, which may not have included every possible accident location. Analog calculations (no biasing) simply follow particles naturally. For sparse buildings and line-of-sight calculations, analog Monte Carlo (MC) may be adequate. For buildings with internal walls or large amounts of heavy equipment (dense geometry), variance reduction may be required. Calculations employing the CADIS method use a deterministic calculation to create an importance map and a matching biased source distribution that optimize the final MC to quickly calculate one specific tally. Calculations employing the FW-CADIS method use two deterministic calculations (one forward and one adjoint) to create an importance map and a matching biased source distribution that are designed to make the MC calculate a mesh tally with more uniform uncertainties in both high-dose and low-dose areas. Depending on the geometry of the problem, the number of detectors, and the number of accident sites, different approaches to CAAS placement studies can be taken. These are summarized in Table I. SCALE 6.1 contains the MAVRIC sequence, which can be used to perform any of the forward-based approaches outlined in Table I. For analog calculations, MAVRIC simply calls the Monaco MC code. For CADIS and FW-CADIS, MAVRIC uses the Denovo discrete ordinates (SN) deterministic code to generate the importance map and biased source used by Monaco. An adjoint capability is currently being added to Monaco and should be available in the next release of SCALE. An adjoint-based approach could be performed with Denovo alone - although fine meshes, large amounts of memory, and long computation times may be required to obtain accurate solutions. Coarse-mesh SN simulations could be employed for adjoint-based scoping studies until the adjoint capability in Monaco is complete. CAAS placement studies, especially those dealing with mesh tallies, require some extra utilities to aid in the analysis. Detectors must receive a minimum dose rate in order to alarm; therefore, a simple yes/no plot could be more useful to the analyst than a standard dose rate contour plot. Alarm systems that require several detectors to alarm simultaneously for a given accident would need to combine several yes/no plots in order to show accident sites where multiple detectors would be triggered. This could require a plot of 'areas of coverage' that is mapped over the building geometry. Several new utilities (which will be part of SCALE 6.2) were created to help with CAAS analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗