Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Top-emission Si-based phosphor organic light emitting diode with Au doped ultrathin n-Si film anode and bottom Al mirror

We report a highly efficient top-emission Si-based phosphor organic light emitting diode (PhOLED) with an ultrathin polycrystalline n-Si:Au film anode and a bottom Al mirror. This anode is formed by magnetron sputtering followed by Ni induced crystallization and then Au diffusion. By optimizing the thickness of the n-Si:Au film anode, the Au diffusion temperature, and the other parameters of the PhOLED, the highest current and power efficiencies of the n-Si:Au film anode PhOLED reached 85{+-}9 cd/A and 80{+-}8 lm/W, respectively, corresponding to an external quantum efficiency of 21{+-}2% and a power conversion efficiency of 15{+-}2%, respectively, which are about 60% and 110% higher than those of the indium tin oxide anode counterpart and 70% and 50% higher than those of the bulk n{sup +}-Si:Au anode counterpart, respectively.

36 MATERIALS SCIENCE↗

Mg segregation in Mg-rich Mg-Ni switchable mirror studied by Rutherford backscattering, elastic recoil detection analysis, and nuclear reaction analysis

Pd/Mg{sub 3.3}Ni films were prepared by dc sputtering deposition on three different substrates of glass, diamondlike carbon/Si, and Si. Hydrogenation and dehydrogenation cycles were performed on these samples simultaneously. The optical switching property due to the hydrogenation and dehydrogenation was monitored by the transmission of laser light via the glass substrate. The switching ability was totally lost after 120 cycles. We made comparative study of the composition change between the new (as-deposited) and old (after 120 switching cycles) samples by Rutherford backscattering (RBS), elastic recoil detection analysis (ERDA), and nuclear reaction analysis (NRA). From the RBS results we found out the segregation of a Mg layer between the Pd cap layer and the rest of the Mg-Ni layer. At the Pd/Mg interface in the old sample, thin MgO layer formed probably during the dehydrogenation process with O{sub 2}. ERDA showed that there is much hydrogen in the old sample. NRA displayed the depth profiles of hydrogen distribution in the old sample. It is revealed that much hydrogen is accumulated at the interface between the Pd cap layer and the segregated Mg layer. It can be concluded that the formations of oxide and hydride of the segregated Mg layer are the main reasons for the degradation of the Mg{sub 3.3}Ni switchable mirror.

36 MATERIALS SCIENCE↗

Mirror instability in a plasma with cold gyrating dust particles

In this work linear stability analysis of a magnetized dusty plasma with an anisotropic dust component having transversal motions much stronger than motions parallel to the external magnetic field and isotropic light plasma components is described. Such a situation presumably establishes in a shock compressed space dusty plasma downstream the shock front. Oblique low-frequency magnetohydrodynamic waves (omega<<omega{sub cd}, omega{sub cd} being the dust cyclotron frequency) are shown to be undergone to the mirror instability. Consequences for nonthermal dust destruction behind shock fronts in the interstellar medium are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-destructive observation of in-grown stacking faults in 4H-SiC epitaxial layer using mirror electron microscope

Mirror electron microscope (MEM) observation has been conducted for a 4-{mu}m-thick n-doped 4H-SiC epitaxial layer. If the sample is simultaneously illuminated with ultraviolet (UV) light of a slightly greater energy than the bandgap energy of 4H-SiC, in-grown stacking faults (IGSFs) can be clearly observed in MEM images. These observations were performed non-destructively, as almost all irradiated electrons returned without impinging the sample surface due to the negative voltage applied to the sample. High spatial resolution observation via MEM showed that multiple IGSFs were stacked up. The phenomenon in which the contrast of the IGSFs vanished in the absence of UV illumination and under UV illumination with a lower energy than the bandgap energy revealed that the origin of the contrast was the negative charging of IGSFs trapping electrons excited by UV light.

36 MATERIALS SCIENCE↗

Flute instability in the tandem mirror with the divertor/dipole regions

The numerical simulation is performed in GAMMA10 A-divertor magnetic configuration, which is a candidate of remodeled device of the GAMMA10 tandem mirror [M. Inutake et al., Phys. Rev. Lett. 55, 939 (1985)]. Both divertor and dipole regions are included in the numerical calculation, which is a new point. The electron short circuit effect along x-point, therefore, is not assumed so that it is not used the boundary condition of the electrostatic perturbations being zero at the separatrix on which the magnetic field lines pass through x-point. The simulation results reveal that the dipole field plays a role of a good magnetic field line curvature to the GAMMA10 A-divertor, and so the flute modes are stabilized without help of electron short circuit effects.

36 MATERIALS SCIENCE↗

Neutron diagnostics for mirror hybrids

Fusion-fission (FuFi) hybrids will need instrumentation to diagnose the deuteriumtritium plasma, whose 14-MeV neutron emission is the driver of the sub-critical fission core. While the fission neutron yield rate (Y{sub fi} and hence power P{sub fi}) can be monitored with standard instrumentation, fusion plasmas in hybrids require special diagnostics where the determination of Y{sub th} ({proportional_to}P{sub fu}) is a challenge. Information on Y{sub fu} is essential for assessing the fusion plasma performance which together with Y{sub fi} allows for the validation of the neutron multiplication factor (k) of the subcritical fission core. Diagnostics for hybrid plasmas are heuristically discussed with special reference to straight field line mirror (SFLM). Relevant DT plasma experience from JET and plans for ITER in the main line of fusion research were used as input. It is shown that essential SFLM plasma information can potentially be obtained with proposed instrumentation, but the state of the hybrid plasma must be predictably robust as derived from fully diagnosed dedicated experiments without interface restrictions of the hybrid application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of polarization-controlled multi-pass Thomson scattering system in the GAMMA 10 tandem mirror

In the GAMMA 10 tandem mirror, the typical electron density is comparable to that of the peripheral plasma of torus-type fusion devices. Therefore, an effective method to increase Thomson scattering (TS) signals is required in order to improve signal quality. In GAMMA 10, the yttrium-aluminum-garnet (YAG)-TS system comprises a laser, incident optics, light collection optics, signal detection electronics, and a data recording system. We have been developing a multi-pass TS method for a polarization-based system based on the GAMMA 10 YAG TS. To evaluate the effectiveness of the polarization-based configuration, the multi-pass system was installed in the GAMMA 10 YAG-TS system, which is capable of double-pass scattering. We carried out a Rayleigh scattering experiment and applied this double-pass scattering system to the GAMMA 10 plasma. The integrated scattering signal was made about twice as large by the double-pass system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-250 nm low-threshold deep-ultraviolet AlGaN-based heterostructure laser employing HfO{sub 2}/SiO{sub 2} dielectric mirrors

We report a sub-250-nm, optically pumped, deep-ultraviolet laser using an Al{sub x}Ga{sub 1−x}N-based multi-quantum-well structure grown on a bulk Al-polar c-plane AlN substrate. TE-polarization-dominant lasing action was observed at room temperature with a threshold pumping power density of 250 kW/cm{sup 2}. After employing high-reflectivity SiO{sub 2}/HfO{sub 2} dielectric mirrors on both facets, the threshold pumping power density was further reduced to 180 kW/cm{sup 2}. The internal loss and threshold modal gain can be calculated as 2 cm{sup −1} and 10.9 cm{sup −1}, respectively.

36 MATERIALS SCIENCE↗

Omnidirectional mirror based on Bragg stacks with a periodic gain-loss modulation

In this work we demonstrate that a Bragg Stack with a periodic gain-loss modulation can function as an Omnidirectional Mirror (OM) with complete reflection at any angle of incidence irrespective of the light polarization. The Bragg Stack is composed by the periodic variation of two layers with the same value of the real part of the refractive index (n{sub r}) and a periodic modulation in the imaginary part (n{sub i}). The origin of the band gaps is due to the interference of complex waves with propagating and evanescent fields in each layer. It is found that the band gaps are wider as the contrast n{sub i}/n{sub r} increases. We have found the ambient conditions to obtain an OM considering an auxiliary medium n{sup ′} external to the Bragg Stack.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High power test of a wideband diplexer with short-slotted metal half mirrors for electron cyclotron current drive system

The wideband high power diplexer has been developed for combining and fast switching of high power millimeter waves generated by a dual frequency gyrotron. The actual diplexer was tested at the frequency band of 170 GHz in low power. After adjusting a resonant frequency of diplexer for the gyrotron frequency, the evacuated wideband diplexer with short-slotted metal half mirrors was tested at an incident power of about 150 kW, a pulse duration of 30 ms and a frequency band of 170.2–170.3 GHz. Any discharge damage was not observed in the diplexer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A microwave tomography system using a tunable mirror for beam steering

Microwave tomography is a fast-growing technique in the fields of NDE and medical industry. This paper presents a new microwave tomography system which reduces the complexities of conventional microwave imaging systems by utilizing a reconfigurable mirror, a tunable reflectarray antenna. In order to build a tunable reflectarray with beam steering capabilities, the unit cell characteristics should dynamically alter. Modelling and experimental results of a single unit cell are presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New insights on boundary plasma turbulence and the quasi-coherent mode in Alcator C-Mod using a Mirror Langmuir Probe

A new “Mirror Langmuir Probe” diagnostic, combined with a double-coil scanning magnetic probe, is used to interrogate Alcator C-Mod's quasi-coherent mode (QCM) with unprecedented detail. In ohmic EDA H-modes, the QCM is found to reside in a region of positive radial electric field, with a radial width (∼3 mm) that spans open and closed field line regions. Large amplitude, in-phase sinusoidal bursts (∼100 kHz) in density, electron temperature, and plasma potential are observed, with potential lagging density by ∼16°, producing an outward radial transport velocity of ∼10 m/s. Mode propagation corresponds to the sum of local E × B and electron diamagnetic drift velocities. Poloidal magnetic field fluctuations project to current filaments carrying peak current densities of ∼25 A/cm{sup 2}. An evaluation of parallel electron force balance (Ohm's law) over a fluctuation cycle indicates a significant electromotive component. Interchange drive is also a contributor in the current continuity (vorticity) equation. Thus, the QCM is primarily a separatrix-spanning electron drift-wave with interchange and electromagnetic contributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft x-ray intensity profile measurements of electron cyclotron heated plasmas using semiconductor detector arrays in GAMMA 10 tandem mirror

Temporally and spatially resolved soft x-ray analyses of electron cyclotron heated plasmas are carried out by using semiconductor detector arrays in the GAMMA 10 tandem mirror. The detector array has 16-channel for the measurements of plasma x-ray profiles so as to make x-ray tomographic reconstructions. The characteristics of the detector array make it possible to obtain spatially resolved plasma electron temperatures down to a few tens eV and investigate various magnetohydrodynamic activities. High power electron cyclotron heating experiment for the central-cell region in GAMMA 10 has been started in order to reduce the electron drag by increasing the electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chirality-related interactions and a mirror symmetry violation in handed nano structures

Hindering of inversion transitions and a violation of mirror symmetry of the right- and left-handed configurations of diazabizyclooctane (dabco, N{sub 2}C{sub 6}H{sub 12}) enantiomers has been studied with low-temperature adiabatic calorimetry. The dabco molecules were sandwiched in a high-porous layered structure of a metal organic framework (MOF) compound. We show from the data of low-temperature adiabatic calorimetry and {sup 1}H NMR spin relaxation method that hindering of inversion transitions of dabco molecules cannot be associated with the influence of the intracrystalline self-consistent molecular field as a continuously monitoring environment within the quantum Zeno effect. In addition, lack of another manifestation of this effect associated with the collisional suppression of the inversion transitions in MOF samples impregnated by helium has been shown. These results lead to the conclusion that chiral polarization is related to the fundamental effect of parity nonconservation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced visible and near-infrared capabilities of the JET mirror-linked divertor spectroscopy system

The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dβ, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision tilt stage as a key element to a universal test mirror for characterization and calibration of slope measuring instruments

The ultimate performance of surface slope metrology instrumentation, such as long trace profilers and auto-collimator based deflectometers, is limited by systematic errors that are increased when the entire angular range is used for metrology of significantly curved optics. At the ALS X-Ray Optics Laboratory, in collaboration with the HZB/BESSY-II and PTB (Germany) metrology teams, we are working on a calibration method for deflectometers, based on a concept of a universal test mirror (UTM) [V. V. Yashchuk et al., Proc. SPIE 6704, 67040A (2007)]. Potentially, the UTM method provides high performance calibration and accounts for peculiarities of the optics under test (e.g., slope distribution) and the experimental arrangement (e.g., the distance between the sensor and the optic under test). At the same time, the UTM calibration method is inherently universal, applicable to a variety of optics and experimental arrangements. In this work, we present the results of tests with a key component of the UTM system, a custom high precision tilt stage, which has been recently developed in collaboration with Physik Instrumente, GmbH. The tests have demonstrated high performance of the stage and its capability (after additional calibration) to provide angular calibration of surface slope measuring profilers over the entire instrumental dynamic range with absolute accuracy better than 30 nrad. The details of the stage design and tests are presented. We also discuss the foundation of the UTM method and calibration algorithm, as well as the possible design of a full scale UTM system.

47 OTHER INSTRUMENTATION↗

Reflectance characterization of tape-based plasma mirrors

Specular reflections of relativistic laser pulses from an overdense plasma mirror (PM) were studied experimentally. The pointing stability of the PM and reflectance of the input laser were characterized. The solid material used for the PM was a VHS tape. This study was done for the magnetic and plastic sides of the VHS tape, and for input light of both s and p-polarizations. The laser pulse fluence was varied by changing the focus position relative to the tape surface, which changed the spot size at the tape. The pointing fluctuations of the reflected pulses caused by the PM were 1 mrad. A peak reflectance of 82% was obtained from the plastic surface of the VHS tape when focusing s-polarized light 4 mm from the tape surface (the wavefront quality was confirmed to be conserved). An analytic model was developed to understand the physics of the interaction for each tape material and polarization. Fitting of our model parameters to the experimental results allowed an estimate of the key plasma parameters such as plasma expansion velocity, ionization intensity, and fraction of absorbed laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of effect of electron cyclotron heating in a tandem mirror plasma using a semiconductor detector array and an electrostatic energy analyzer

Temporally and spatially resolved soft x-ray and end-loss-electron analyses of the electron cyclotron heated plasmas are carried out by using a semiconductor detector array and an electrostatic energy analyzer in the GAMMA 10 tandem mirror. The flux and the energy spectrum of the end loss electrons are measured by a multi-grid energy analyzer. Recently, the electron cyclotron heating power modulation experiments have been started in order to generate and control the high heat flux and to make the edge localized mode-like intermittent heat load pattern for the divertor simulation studies by the use of these detectors for electron properties.

43 PARTICLE ACCELERATORS↗