The Neutron Scattering Cross Section and Angular Distribution Measurement Program at LANL
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Untangling the roles of different plasma formation mechanisms in high-current electrical discharges requires controlling each mechanism and isolating its effects. Recent experiments use this method to find that thermal formation of plasma occurs from 6061-alloy Al conductors by ohmic heating when the surface field reaches a magnetic field threshold of 2.2 MG (independently of {partial_derivative}B/{partial_derivative}t ranging from 30 to 80 MG/{mu}s) [T. J. Awe et al., Phys. Rev. Lett. 104, 035001 (2010)]. The experiments pulse 1.0 MA peak current on the surface of thick ({approx}1.0 mm diameter) aluminum rods in 100 ns. Strong electric fields are necessarily introduced, and precursor plasma may form (e.g., from arcing electrical contacts). To ensure plasma formation is predominantly thermal, a systematic study of multiple combinations of high-current electrodes and central-rod profiles was completed. Data from multiple diagnostics show that the time and location of plasma formation strongly correlate with the hardware combination used. An extensive dataset (greater than 100 shots) enabled numerous hypotheses to be tested regarding plasma formation mechanisms. For hardware with compressed, large-diameter current joints, plasma formation is a predominantly thermal process driven by ohmic heating.
Explore the source record for details and available documents.
Recent data on the EMC effect from Jefferson Lab experiment E03103 suggest that the nuclear dependence of the high x quark distribution may depend on the local nuclear environment, rather than being a purely bulk effect. We briefly discuss the analysis and results of the E03103 experiment focusing on the light nuclei and high x region. In addition, we also discuss a future experiment at the upgraded 12 GeV Jefferson Lab facility which will further investigate the role of the local nuclear environment and the influence of detailed nuclear structure on the modification of quark distributions.
A microfabricated amorphous silicon nitride membrane-based nanocalorimeter is proposed to be suitable for an x-ray transparent sample platform with low power heating and built-in temperature sensing. In this work, thermal characterization in both air and vacuum are analyzed experimentally and via simulation. Infrared microscopy and thermoreflectance microscopy are used for thermal imaging of the sample area in air. While a reasonably large isothermal area is found on the sample area, the temperature homogeneity of the entire sample area is low, limiting use of the device as a heater stage in air or other gases. A simulation model that includes conduction, as well as radiation and convection heat loss, is presented with radiation and convection parameters determined experimentally. Simulated temperature distributions show that the homogeneity can be improved by using a thicker thermal conduction layer or reducing the pressure of the gas in the environment but neither are good solutions for the proposed use. A new simple design that has improved temperature homogeneity and a larger isothermal area while maintaining a thin thermal conduction layer is proposed and fabricated. This new design enables applications in transmission x-ray microscopes and spectroscopy setups at atmospheric pressure.
The Dante is a 15 channel filtered diode array which is installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The system yields the spectrally and temporally resolved radiation flux from 50 eV to 10 keV from various targets (i.e., Hohlraum, gas pipes, etc.). The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and an unfold algorithm applied to the recorded voltages from each channel. The unfold algorithm assumes an emitting source that is spatially uniform and has a constant area as a function of photon energy. The emitting x-ray source is usually considered to be the laser entrance hole (LEH) of a given diameter for Hohlraum type targets or the effective wall area of high conversion efficiency K-shell type targets. This assumption can be problematic for several reasons. High intensity regions or 'hot spots' in the x-ray are observed where the drive laser beams strike the target. The 'hot spots' create non-uniform emission seen by the Dante. Additionally, thinned walled (50 {mu}m) low-Z targets (C{sub 22}H{sub 10}N{sub 2}O{sub 5}) have an energy dependent source size since the target's walls will be fully opaque for low energies (E < 2-3 keV) yet fully transmissive at higher energies. Determining accurate yields can be challenging for these types of targets. Discussion and some analysis will be presented.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In this paper, we study a class of stochastic nonlinear wave equation with memory driven by Lévy noise. We first show the existence and uniqueness of global mild solutions using a suitable energy function. Second, under some additional assumptions we prove the exponential stability of the solutions.
A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device (CCD) detector in a double-beam configuration, we employ a non-resonant line or a resonant line with lower absorbance from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.
The synthesis of metal nanoparticles by ultrafast laser ablation of nanometers-thick metal films has been studied experimentally and computationally. Near-threshold backside laser ablation of 2–20 nm-thick Pt films deposited on fused silica substrates was found to produce nanoparticles with size distributions that were bimodal for the thicker films, but collapsed into a single mode distribution for the thinnest film. Time-resolved imaging of blackbody emission from the Pt nanoparticles was used to reveal the nanoparticle propagation dynamics and estimate their temperatures. The observed nanoparticle plume was compact and highly forward-directed with a well-defined collective velocity that permitted multiple rebounds with substrates to be revealed. Large-scale molecular dynamics simulations were used to understand the evolution of compressive and tensile stresses in the thicker melted liquid films that lead to their breakup and ejection of two groups of nanoparticles with different velocity and size distributions. Ultrafast laser irradiation of ultrathin (few nm) metal films avoids the splitting of the film and appears to be a method well-suited to cleanly synthesize and deposit nanoparticles from semitransparent thin film targets in highly directed beams.
In this work, we present the results of experiments observing the properties of the electron stream generated laterally when a laser irradiates a metal. We find that the directionality of the electrons is dependent upon their energies, with the higher-energy tail of the spectrum (∼1 MeV and higher) being more narrowly focused. This behavior is likely due to the coupling of the electrons to the electric field of the laser. The experiments are performed by using the Titan laser to irradiate a metal wire, creating the electron stream of interest. These electrons propagate to nearby spectator wires of differing metals, causing them to fluoresce at their characteristic K-shell energies. This fluorescence is recorded by a crystal spectrometer. By varying the distances between the wires, we are able to probe the divergence of the electron stream, while by varying the medium through which the electrons propagate (and hence the energy-dependence of electron attenuation), we are able to probe the energy spectrum of the stream.