Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Wavelength-scale deformed microdisk lasers

We investigate lasing and output directionality of limacon-shaped microdisk lasers of dimensions comparable to the emission wavelength. The far-field patterns are shown to differ between lasing modes, unlike in large cavities where lasing modes exhibit universal emission directionality determined by chaotic ray dynamics. Unidirectional emission is obtained for certain modes in the wavelength-scale cavities. It results from weak coupling of nearly isotropic high-quality resonances to anisotropic low-quality resonances, combined with chiral symmetry breaking of clockwise and counterclockwise propagating waves. The latter is described by an extended ray dynamics which includes the Goos-Haenchen shift and the Fresnel filtering. Mode hybridization and wave effects in open cavities make it possible to control the output properties of individual lasing modes in wavelength-scale lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser diagnostics of the built-in electric field across the p{sup +}-Si/SiO{sub 2} interface and its ultrafast shielding

Ultrafast shielding of the built-in electric field E{sub 0} across the p{sup +}-Si/SiO{sub 2} interface of boron doped Si upon near infrared femtosecond (fs) laser pulse irradiation (73 {+-} 5 fs, 35 GW/cm{sup 2}{<=} I{sub peak}{sup ({omega})} {<=} 115 GW/cm{sup 2}) is shown to be dominated by electron-hole (e-h) pairs generated via two-photon absorption (TPA), whereas contributions from one-photon absorption (OPA) appear negligible. E{sub 0} shows up in the instantaneous signal I{sup (2{omega})}(t Almost-Equal-To 0) Almost-Equal-To I{sup (2{omega})}(E{sub 0}) of the Electric Field Induced Second Harmonic (EFISH). Its power law is derived from the linear log I{sup (2{omega})}(E{sub 0}) vs. log (I{sub peak}{sup ({omega})}){sup n} plots of six fs laser wavelengths 741.2 nm {<=} {lambda} {<=} 801.0 nm for the first time. These reveal 1.2 {<=} n({lambda}) {<=} 2.1 with the minimum at {lambda} = 752.4 nm (2h{nu} = 3.3 eV) related to resonantly enhanced TPA. Shielding of E{sub 0} by e-h pairs from OPA cannot be detected by EFISH in the same fs laser pulse as their generation requires relatively slow electron-phonon coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Terahertz metasurface quantum-cascade VECSELs: theory and performance

A longstanding challenge for terahertz quantum-cascade (QC) lasers is achieving both a high power and high-quality beam pattern, this is due in part due to their use of sub-wavelength metallic waveguides. Recently, the vertical-external-cavity surface-emitting laser (VECSEL) concept was demonstrated for the first time in the terahertz range and for a QC-laser. This is enabled by the development of an amplifying metasurface reflector capable of coupling incident free-space THz radiation to the QC-laser material such that it is amplified and re-radiated. The THz metasurface QC-VECSEL initiates a new approach for making QC-lasers with high power and excellent beam pattern. Furthermore, the ability to engineer the electromagnetic phase, amplitude, and polarization response of the metasurface enables lasers with new functionality. Our article provides an overview of the fundamental theory, design considerations, and recent results for high-performance THz QC-VECSELs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable diode array pumped Nd rod laser

Experiments were carried out on a five-array pump head which utilizes gold-coated reflective cones to couple the pump energy to Nd:YAG and Nd:YLF rod lasers, demonstrating high efficiency and uniform energy deposition. Because the cones function as optical diodes to light outside their acceptance angle (typically 10-15 deg), much of the diode energy not absorbed on the first pass can be returned to the rod.

Zenzie, H. H.↗

A new approach to entangling neutral atoms.

Our team has developed a new approach to entangling neutral atoms with a Rydberg-dressed interaction. Entangling neutral atoms is an essential key of quantum technologies such as quantum computation, many-body quantum simulation, and high-precision atomic sensors . The demonstrated Rydberg-dressed protocol involves adiabatically imposing a light shift on the ground state by coupling an excited Rydberg state with a tuned laser field. Using this technique, we have demonstrated a strong and tunable dipole - dipole interaction between two individually trapped atoms with energy shifts of order 1 MHz, which has been challenging to achieve in other protocols . During this program, we experimentally demonstrated Bell-state entanglement and the isomorphism to the Jaynes - Cumming model of a Rydberg-dressed two-atom system. Our theoretical calculations of a CPHASE quantum logic gate and arbitrary Dicke state quantum control in this system encourage further work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wakefield effects and solitary waves of an intense short laser pulse propagation in a plasma channel

In the presence of relativistic and channel-coupling nonlinearity and wakefield effects, the propagation characteristics and solitary waves of an intense short laser pulse in a preformed plasma channel are investigated. The evolution equation of the laser spot size is derived by using variational technique, the initial laser and plasma parameters for propagation with constant spot size, periodic defocusing and focusing oscillations, and solitary waves are identified. For illustration, some numerical results are also presented. It is found that the laser focusing is enhanced by the wakefield effects that result in a significant reduced focusing power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite aperture waveguide laser resonators

A general theory of finite aperture waveguide laser resonators is developed which represents the external reflectors by matrices which couple linearly polarized waveguide modes having the same azimuthal symmetry. The theory allows the determination of resonator efficiency, resonator frequencies, and laser near and far field patterns. Computations of the coupling loss for the fundamental waveguide mode as a function of mirror curvature, separation, and aperture are in agreement with recent infinite aperture calculations in the limit of large apertures and indicate three low-loss configurations: large radius of curvature mirrors close to the guide; large radius of curvature mirrors centered at the guide entrance; and generally smaller curvature mirrors separated by half their curvature from the guide entrance. Design guidelines for construction of high efficiency CO2, CO and He-Ne waveguide laser resonators are summarized in tabular form.

Degnan, J. J.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Time-resolved observation of the plasma induced by laser metal ablation in air at atmospheric pressure

Most of the previous studies on nanosecond (ns) laser-induced plasma typically use relatively short ns laser pulses (pulse duration less than {approx}30 to 50 ns). In this paper, relatively long ns laser pulses with 200 ns duration have been used, and the produced plasma during metal ablation in air at atmospheric pressure has been studied through time-resolved observation using an intensified charge-coupled device camera. Due to the much longer ns laser pulse duration, the plasma radiation intensity distribution and the plasma front propagation have different physical features from those produced by much shorter ns laser pulses. In particular, it has been observed that during the laser pulse the plasma has two high-radiation-intensity regions: one is located right above the target surface while the other is behind the expanding plasma front. The former region will disappear once the laser pulse completes. This interesting physical phenomenon has been rarely reported, and requires further experimental and modeling study to completely understand.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling the spectrum of light pulses by dynamical electromagnetically induced transparency

We present a theoretical and experimental study on the possibility of spectral manipulation of weak probe-laser pulses in the presence of dynamical electromagnetically induced transparency. We predict a spectral enlargement or narrowing process depending on whether the probe-laser pulse is overlapped by the rising or the falling edge of the coupling pulse, respectively. The results of an experiment in sodium atomic vapors confirm the theoretical predictions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermooptical excitation of sound by Bessel light beams in crystalline media with internal stress

The thermooptical excitation of sound by Bessel light beams in crystalline media with internal stress has been studied. The dependence of the thermoelastic coupling coefficient, which is due to the modulated absorption of laser radiation, on the initial strain in a crystalline sample is taken into account. The expression for the photoacoustic signal amplitude is obtained, and it is shown that, in the range of high modulation frequencies of TE modes of Bessel light beams, resonant phenomena occur which can be used to increase the resolution of laser photoacoustic diagnostics of elastically strained crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large mode-volume, large beta, photonic crystal laser resonator

We propose an optical resonator formed from the coupling of 13, L2 defects in a triangular-lattice photonic crystal slab. Using a tight-binding formalism, we optimized the coupled-defect cavity design to obtain a resonator with predicted single-mode operation, a mode volume five times that of an L2-cavity mode and a beta factor of 0.39. The results are confirmed using finite-difference time domain simulations. This resonator is very promising for use as a single mode photonic crystal vertical-cavity surface-emitting laser with high saturation output power compared to a laser consisting of one of the single-defect cavities.

36 MATERIALS SCIENCE↗

Computational Study of Thrust Generation from Laser-Driven Blast Wave

We have performed axisymmetric simulations in order to investigate the thrust generation resulting from the interference between the projectile and the blast wave produced by a pulsed laser. The results obtained by our numerical code well agree for the pressure history and the momentum coupling coefficient with the experimental data. In such analysis, it is found that the approximate impulse estimated only by the pressure history at the projectile base is difficult to predict the actual one. Since the shock wave rapidly attenuates in low fill pressure, and the interaction with the projectile almost finishes in the shroud, a high momentum coupling coefficient can be achieved unlike the case of high fill pressure in which the projectile experiences the subsequent negative thrust.

43 PARTICLE ACCELERATORS↗

Vibrational Cooper minima used to verify the dissociation pathway induced by a short intense laser pulse

Vibrational Cooper minima due to weak dipole coupling were previously observed in strong-field dissociation of H 2⁡ + as minima in the kinetic-energy-release (KER) spectrum [McKenna et al., Phys. Rev. Lett. 103, 103006 (2009)]. We demonstrate in two independent experiments that these vibrational Cooper minima occur more generally and can be used as “fingerprints” to identify the final electronic state in the dissociation pathway. In the first experiment, we show the wavelength dependence of the vibrational Cooper minima observed in the KER spectrum of O 2⁢ + dissociation induced by 396- and 264-nm photons. These minima appear at the locations predicted by our first-order perturbation-theory calculations. In the second experiment, a delay-dependent KER spectrum is obtained from O 2 using an ionizing pump and a dissociating probe, then Fourier-transformed to generate a spin-rotation quantum beat spectrum of O 2 ⁢+ . As a result, this spectrum shows vibrational Cooper minima at the expected locations, confirming their presence in another observable. In this case, these minima are used to identify the dissociation pathway.

Molecular dissociation↗

Dynamic fracture of tantalum under extreme tensile stress

The understanding of fracture phenomena of a material at extremely high strain rates is a key issue for a wide variety of scientific research ranging from applied science and technological developments to fundamental science such as laser-matter interaction and geology. Despite its interest, its study relies on a fine multiscale description, in between the atomic scale and macroscopic processes, so far only achievable by large-scale atomic simulations. Direct ultrafast real-time monitoring of dynamic fracture (spallation) at the atomic lattice scale with picosecond time resolution was beyond the reach of experimental techniques. We show that the coupling between a high-power optical laser pump pulse and a femtosecond x-ray probe pulse generated by an x-ray free electron laser allows detection of the lattice dynamics in a tantalum foil at an ultrahigh strain rate of Embedded Image ~2 × 10 8 to 3.5 × 10 8 s -1 . A maximal density drop of 8 to 10%, associated with the onset of spallation at a spall strength of ~17 GPa, was directly measured using x-ray diffraction. The experimental results of density evolution agree well with large-scale atomistic simulations of shock wave propagation and fracture of the sample. Our experimental technique opens a new pathway to the investigation of ultrahigh strain-rate phenomena in materials at the atomic scale, including high-speed crack dynamics and stress-induced solid-solid phase transitions.

36 MATERIALS SCIENCE↗

Q-Switched Nd: YAG Laser Micro-Machining System

In this paper, we present the design of a low cost Q-switched Nd: YAG laser micro-machining system for photo masks fabrication. It consists of: Nd:YAG laser source, beam delivery system, X-Y table, PC, The CCD camera and TV monitor. The synchronization between the laser source and the X-Y table is realised by NI PCI-7342, the two axis MID-7602 and LabVIEW based program. The first step of this work consists of engraving continuous and discontinuous lines on a thin film metal with a 100 {mu}m resolution by using the YG 980 Quantel Q-switched Nd:YAG laser.

36 MATERIALS SCIENCE↗