ULTRACOATINGS: Enabling Energy and Power Solutions in High Contact Stress Environments through Next-Generation Nanocoatings

This industry-driven project was the result of a successful response by Eaton Corporation to a DOE/ITP Program, Grand Challenge, industry call. It consisted of a one-year effort in which ORNL participated in the area of friction and wear testing. In addition to Eaton Corporation and ORNL (CRADA), the project team included: Ames Laboratory, who developed the underlying concept for titanium- zirconium-boron (TZB) based nanocomposite coatings; Borg-Warner Morse TEC, an automotive engine timing chain manufacturer in Ithaca, New York, with its own proprietary hard coating; and Pratt & Whitney Rocketdyne, Inc., a dry-solids pump manufacturer in San Fernando Valley, California. This report focuses only on the portion of work that was conducted by ORNL, in a CRADA with Eaton Corporation. A comprehensive final report for the entire effort, which ended in September 2010, has been prepared for DOE by the team. The term 'ultracoatings' derives from the ambitious technical target for the new generation of nanocoatings. As applications, Eaton was specifically considering a fuel pump and a gear application in which the product of the contact pressure and slip velocity during operation of mating surfaces, commonly called the 'PV value', was equal to or greater than 70,000 MPa-m/s. This ambitious target challenges the developers of coatings to produce material capable of strong bonding to the substrate, as well as high wear resistance and the ability to maintain sliding friction at low, energy-saving levels. The partners in this effort were responsible for the selection and preparation of such candidate ultracoatings, and ORNL used established tribology testing capabilities to help screen these candidates for performance. This final report summarizes ORNL's portion of the nanocomposite coatings development effort and presents both generated data and the analyses that were used in the course of this effort. Initial contact stress and speed calculations showed that laboratory tests with available geometries, applied forces, and speeds at ORNL could not reach 70,000 MPa-m/s for the project target, so test conditions were modified to enable screening of the new coating compositions under conditions used in a prior nano-coatings development project with Eaton Corporation and Ames Laboratory. Eaton Innovation Center was able to conduct screening tests at higher loads and speeds, thus providing complementary information on coating durability and friction reduction. Those results are presented in the full team's final report which is in preparation at this writing. Tests of two types were performed at ORNL during the course of this work: (1) simulations of timing chain wear and friction under reciprocating conditions, and (2) pin-on-disk screening tests for bearings undergoing unidirectional sliding. The four materials supplied for evaluation in a timing chain link simulation were hardened type 440B stainless steel, nitrided type 440B stainless steel, vanadium carbide (VC)-coated type 52100 bearing steel, and (ZrTi)B-coated type 52100 bearing steel. Reciprocating wear tests revealed that the VC coating was by far the most wear resistant. In friction, the nitrided stainless steel did slightly better than the other materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proton Exchange Membrane Fuel Cell Transient Load Response

Spaceflight mission profiles may not be limited to constant power loads. It is necessary for the associated power system to support changes in load in addition to being energy dense. H2-O2 proton exchange membrane (PEM) fuel cells can accommodate such requirements without significant current smoothing or additional devices to provide transient power. This testing involved current load step changes to characterize non-flow-through PEM fuel cell response to increasing and decreasing load step changes over a range of 0 to 0.5 A/sq. cm. It was determined that fuel cell output voltage stabilizes within 4 ms with no noticeable steady-state performance degradation, following exposure of the fuel cell to transient loads of up to ~1.5 A/sq. cm. Faster stabilization generally occurred following larger step changes.

fuel cell↗

All arthroscopic remnant-preserving reconstruction of the lateral ligaments of the ankle: A biomechanical study and clinical application

Highlights: • Two surgical techniques of ATFL and CFL reconstruction produce similar the strength and stiffness • The strength and stiffness of reconstructed ATFL and CFL are weaker than the intact, uninjured ATFL and CFL. • All arthroscopic remnant-preserving reconstruction of ATFL and CFL has good short-term clinical effect. Lateral ankle sprains are one of the most common injuries in sports. Recently, arthroscopic lateral ligament reconstruction has been recently advocated, however no biomechanical studies and clinical application of this technique are available. In this biomechanical study, eighteen fresh-frozen cadaveric ankles were randomized into three groups: (1) intact anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL), (2) arthroscopic anatomic reconstruction of ATFL and CFL, and (3) all arthroscopic remnant-preserving reconstruction of ATFL and CFL. The specimens were then tested for stiffness and load to ultimate failure using a customized jig. In biomechanical test, the all arthroscopic remnant-preserving reconstruction of ATFL and CFL produced a reconstruction that could withstand loads to failure and stiffness similar to the arthroscopic anatomic reconstruction. However, both two reconstruction groups were much weaker than the intact, uninjured ATFL and CFL. Moreover, we used the technique of all arthroscopic remnant-preserving reconstruction of ATFL and CFL on 20 patients from September 2016 to September 2017. American Orthopaedic Foot and Ankle Society (AOFAS) scores and Anterior Talar Translation (ATT) were applied for statistical collection at preoperative and postoperative 12 months to evaluate clinical efficacy. The differences of the preoperative and postoperative 12 months AOFAS scores and ATT of patients were both statistical significant (P < 0.01). We confirmed that all arthroscopic remnant-preserving reconstruction of ATFL and CFL exhibited positive effect, thus promoting the recovery of ankle function and had good short-term clinical effect.

60 APPLIED LIFE SCIENCES↗

Preloading To Accelerate Slow-Crack-Growth Testing

An accelerated-testing methodology has been developed for measuring the slow-crack-growth (SCG) behavior of brittle materials. Like the prior methodology, the accelerated-testing methodology involves dynamic fatigue ( constant stress-rate) testing, in which a load or a displacement is applied to a specimen at a constant rate. SCG parameters or life prediction parameters needed for designing components made of the same material as that of the specimen are calculated from the relationship between (1) the strength of the material as measured in the test and (2) the applied stress rate used in the test. Despite its simplicity and convenience, dynamic fatigue testing as practiced heretofore has one major drawback: it is extremely time-consuming, especially at low stress rates. The present accelerated methodology reduces the time needed to test a specimen at a given rate of applied load, stress, or displacement. Instead of starting the test from zero applied load or displacement as in the prior methodology, one preloads the specimen and increases the applied load at the specified rate (see Figure 1). One might expect the preload to alter the results of the test and indeed it does, but fortunately, it is possible to account for the effect of the preload in interpreting the results. The accounting is done by calculating the normalized strength (defined as the strength in the presence of preload the strength in the absence of preload) as a function of (1) the preloading factor (defined as the preload stress the strength in the absence of preload) and (2) a SCG parameter, denoted n, that is used in a power-law crack-speed formulation. Figure 2 presents numerical results from this theoretical calculation.

Gyekenyesi, John P.↗

Results of high heat flux tests of tungsten divertor targets under plasma heat loads expected in ITER and tokamaks (review)

Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.

36 MATERIALS SCIENCE↗

Fatigue crack propagation behavior of the Ni-Ni3Cb eutectic composite

The experimental procedures used in the investigation are considered, taking into account solidification and heat treatment, fatigue testing, questions of test specimen and loading fixture design verification, metallographic techniques, and electron microscopy techniques. Attention is given to the characteristics of the microstructure, aspects of fatigue crack propagation (FCP) in the Ni-Ni3Nb composite, the effect of test variables on FCP, the effect of metallurgical variables on FCP, and fatigue fracture mechanisms. Fractographic and metallographic observations are discussed.

Mills, W. J.↗

Impact tests on fibrous composite sandwich structures

The effect of low velocity impact on the strength of laminates fabricated from graphite/epoxy and Kevlar 49/epoxy composite materials was studied. The test laminates were loaded statically either in uniaxial tension or compression when impact occurred to evaluate the effect of loading on the initiation of damage and/or failure. Typical aircraft service conditions such as runway debris encountered during landing were simulated by impacting 1.27-cm-diameter projectiles normal to the plane of the test laminates at velocities between 5.2 and 48.8 m/s.

Rhodes, M. D.↗

Considerations in STS payload environmental verification

Considerations regarding the Space Transportation System (STS) payload environmental verification are reviewed. It is noted that emphasis is placed on testing at the subassembly level and that the basic objective of structural dynamic payload verification is to ensure reliability in a cost-effective manner. Structural analyses consist of: (1) stress analysis for critical loading conditions, (2) model analysis for launch and orbital configurations, (3) flight loads analysis, (4) test simulation analysis to verify models, (5) kinematic analysis of deployment/retraction sequences, and (6) structural-thermal-optical program analysis. In addition to these approaches, payload verification programs are being developed in the thermal-vacuum area. These include the exposure to extreme temperatures, temperature cycling, thermal-balance testing and thermal-vacuum testing.

Keegan, W. B.↗

Application of a gripping system to test a uniaxial graphite fiber reinforced composite /PMR 15/Celion 6000/ in tension at 316 C

A gripping system has been developed to test uniaxial, 0 deg orientation PMR 15/Celion 6000 composites at elevated temperatures. The method involves compression of grit-blasted laminate between grit-blasted metal to give a non-slipping interface for load transfer. Tensile testing at both 316 C and room temperature indicated that deformation was elastic to fracture and that the variation in tensile properties for one laminate is the same as that for several panels. In addition, the tensile properties for uniaxial PMR 15/Celion 6000 are identical at 316 C and room temperature. For nominally 51 volume percent fiber, the elastic modulus is 119.6 GPa, the fracture stress is 1370 MPa, and the strain to fracture is about 1.15 percent. In addition, data are presented which indicate that the gripping system can be used for long term, elevated temperature testing of composite materials.

Whittenberger, J. D.↗

Characterizing Face Sheet/Core Disbonding Using the Single Cantilever Beam Test: Results from an International Round Robin

Test results from an international round robin are presented. The single cantilever beam (SCB) test was used to characterize face sheet/core disbonding in sandwich components in an effort to help standardization. Each of the seven participating laboratories performed a set of five baseline tests using the same protocol, however, using their own specific equipment. In addition, each laboratory performed two sets of tests with altered tests conditions which included using a test fixture with a translating carriage and performing the tests with different loading and unloading speeds. The orientation of the disbond front with respect to the honeycomb core cells was varied and the effect on the fracture toughness was also studied. Additional factors that could influence test results were investigated, such as the use of a saw cut starter disbond as an alternative to Teflon® release film, and the effects of using a face sheet doubler to increase the bending stiffness. For each set of tests, summary results such as load/displacements plots, observed disbond growth location and calculated energy release rates are reported and a comparison of results between labs is presented. Critical strain energy release rate measurements from SCB tests are also compared with measurements made from an alternative test, namely the double cantilever beam with uneven bending moments (DCB-UBM) test, which has been studied extensively at the Technical University of Denmark and proposed as a mixed-mode test standard. A set of recommendations are made with respect to improving the SCB test and a path to standardization is presented.

Ronald Krueger↗

Cycle Consistent Surrogate for Inertial Confinement Fusion

We provide a self-contained package to load, process, and test the ICF JAG dataset. In particular, we include a Neural Network designed to act as a surrogate for the JAG 1D Simulator. The neural network is implemented in Tensorflow. We include a Jupyter notebook which allows a user to load the dataset, load the neural network and train it such that given just the 5 input parameters, it predicts the scalars and images accurately. This can be done directly in the notebook, without any additional modifications. During training, intermediate predictions are also saved to disk (as specified by the user). We hope this serves as a starting point to build, test and play with the ICF-JAG simulation dataset.

Anirudh, Rushil↗

Experimental Analysis of the Crushing of Honeycomb Cores Under Compression

This paper presents an experimental study of the compressive response of hexagonal honeycomb core from the initial elastic regime to a fully crushed state. To understand the crushing mechanism, aluminum honeycomb core was compressed quasi-statically between rigid platens under displacement control. Honeycomb test specimens made of aluminum alloy with different configurations such as cell size, cell number, core density, and specimen size have been tested. During the crushing, the cells buckle elastically and collapse at a higher stress due to inelastic action, after the cells crush by progressive formation of folds on cell walls. The response densifies when folds consume the whole panel height. The peak load recorded during tests corresponded to the buckling of honeycomb cells. The different specimens showed similar load/displacement curves, and the differences observed were only due to the influence of the core density, number of cells, and specimens size on mechanical behavior of hexagonal honeycomb core which has a very important role in the energy absorption capacity. In addition, this study allowed us to build a database of experimental tests for various configurations and allowed us to know the precise energy absorption capacity.

36 MATERIALS SCIENCE↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Program tasks are described consisting of baseline cell design and stack testing, hydrogen pump design and testing, and DM-2 powerplant testing and technology extension efforts. A baseline cell configuration capable of a minimum of 2000 hours of life was defined. A 6-cell prototype stack, incorporating most of the scheme cell features, was tested for a total of 10,497 hours. A 6-cell stack incorporating all of the design features was tested. The DM-2 powerplant with a 34 cell stack, an accessory section packaged in the basic configuration anticipated for the space shuttle powerplant and a powerplant control unit, was defined, assembled, and tested. Cells were used in the stack and a drag-type hydrogen pump was installed in the accessory section. A test program was established, in conjunction with NASA/JSC, based on space shuttle orbiter mission. A 2000-hour minimum endurance test and a 5000-hour goal were set and the test started on August 8, 1972. The 2000-hour milestone was completed on November 3, 1972. On 13 March 1973, at the end of the thirty-first simulated seven-day mission and 5072 load hours, the test was concluded, all goals having been met. At this time, the DM-2 was in excellent condition and capable of additional endurance.

Source record↗

Verification of rain-flow reconstructions of a variable amplitude load history

The suitability of using rain-flow reconstructions as an alternative to an original loading spectrum for component fatigue life testing is investigated. A modified helicopter maneuver history is used for the rain-flow cycle counting and history regenerations. Experimental testing on a notched test specimen over a wide range of loads produces similar lives for the original history and the reconstructions. The test lives also agree with a simplified local strain analysis performed on the specimen utilizing the rain-flow cycle count. The rain-flow reconstruction technique is shown to be a viable test spectrum alternative to storing the complete original load history, especially in saving computer storage space and processing time. A description of the regeneration method, the simplified life prediction analysis, and the experimental methods are included in the investigation.

Clothiaux, John D.↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Design, fabrication and test of graphite/polymide composite joints and attachments: Summary

The design, analysis and testing performed to develop four types of graphite/polyimide (Gr/PI) bonded and bolted composite joints for lightly loaded control surfaces on advanced space transportation systems that operate at temperatures up to 561K (550 F) are summarized. Material properties and 'small specimen' tests were conducted to establish design data and to evaluate specific design details. 'Static discriminator' tests were conducted on preliminary designs to verify structural adequacy. Scaled up specimens of the final joint designs, representative of production size requirements, were subjected to a series of static and fatigue tests to evaluate joint strength. Effects of environmental conditioning were determined by testing aged (125 hours 589K (600 F)) and thermal cycled (116K to 589K (-250 F to 600 F), 125 times) specimens. It is concluded Gr/PI joints can be designed and fabricated to carry the specified loads. Test results also indicate a possible resin loss or degradation of laminates after exposure to 589K (600 F) for 125 hours.

Cushman, J. B.↗

Large-bore tapered-roller bearing performance and endurance to 2.4 million DN

The operating characteristics and experimental life estimates for 120.65 mm bore tapered roller bearings of two designs under combined radial and thrust loads were determined. A modified standard bearing design was tested at speeds up to 15,000 rpm. A computer optimized, high speed design was tested at speeds up to 20,000 rpm. Both designs were tested at a combined load of 26,700 N (6000 lb) radial load and and 53,400 N (12,000 lb) thrust load. Advanced helicopter transmissions which require the higher-speed capability of tapered-roller bearings also require higher temperature capability (ref. 2). Thus, materials with temperature capabilities higher than the conventional carburizing steels are required.

Parker, R. J.↗

Structural Stability of a Stiffened Aluminum Fuselage Panel Subjected to Combined Mechanical and Internal Pressure Loads

Results from an experimental and analytical study of a curved stiffened aluminum panel subjected to combined mechanical and internal pressure loads are presented. The panel loading conditions were simulated using a D-box test fixture. Analytical buckling load results calculated from a finite element analysis are presented and compared to experimental results. Buckling results presented indicate that the buckling load of the fuselage panel is significantly influenced by internal pressure loading. The experimental results suggest that the stress distribution is uniform in the panel prior to buckling. Nonlinear finite element analysis results correlates well with experimental results up to buckling.

Rouse, Marshall↗