At least 1,423 records · Page 79

Modeling Challenges for Energy Recovery Linacs with Long, High Charge Bunches

Historically, nearly all energy recovery linacs (ERLs) built and operated were used to drive a free-electron laser (FEL). The requirement for high peak current bunches necessitates bunch compression and handling the attendant beam dynamical challenges. In recent years, ERLs have turned from being drivers of light sources toward applications for nuclear physics experiments, Compton backscattering sources and strong electron cooling. Unlike an FEL, these latter uses require long, high charge bunches with small energy spread. The electron bunch must maintain a small projected energy spread and therefore must avoid gross distortion due to CSR and longitudinal space charge over a single (or multiple) recirculations. Accurately modeling the relevant collective effects in the system 'space charge, microbunching instability, CSR and the effect of shielding' in addition to beam dynamical processes such as halo, presents a formidable challenge. Absent a code that models all of these effects, we outline an approach towards the design, analysis and optimization of the high-energy electron cooler for the Jefferson Lab Electron-Ion Collider and survey widely used codes and their capabilities.

Tennant, Christopher D.↗

Commissioning of the prototype C75 cavities in a CEBAF cryomodule

Prototype cavities have been built at Jefferson Lab to increase the energy of future refurbished CEBAF cryomodules to 75 MeV in the most cost efficient way. Three such cavities, named "C75", have been built from ingot Nb material of different purity and have been processed and tested. The two better performing cavities have been assembled into a "cavity pair" and installed in the latest refurbished original CEBAF cryomodule. The cryomodule was installed and commissioned in CEBAF. The results from the commissioning of the C75 cavities, compared with the original CEBAF cavities, are presented in this article. The vertical test performance of the C75 cavities was preserved in the cryomodule with one of the cavities achieving the performance specification of an accelerating gradient of 19 MV/m with a quality factor of ~8×109 at 2.07 K. The performance in terms of microphonics and tuner operation was similar to that of original CEBAF cavities, as expected, and the high-order modes are properly damped. The quality factor of the two C75 cavities was the highest achieved in a CEBAF cryomodule, possibly due to the better magnetic flux expulsion of ingot Nb than standard fine-grain Nb.

Drury, Michael A.↗

Commissioning of JLab Vertical Cavity Processing System for SRF Nb Single Cell and Multicell Cavity With HF-Free Pulse-Reverse Electopolishing

Pulse reversed electropolishing of niobium SRF cavities, using a dilute aqueous H2SO4 electrolyte without HF yields equivalent RF performance with traditional EP. Comparing with present EP process for Nb SRF cavity which uses 1:10 volume ratio of HF (49%) and H2SO4 (98%), pulse reverse EP (also known as bipolar EP (BPEP)) is ecologically friendly and uses relatively benign electrolyte options for cavity processing. In this study, we report the commissioning of a new vertical cavity processing system for SRF Nb single cell and multi-cell cavities with HF-free pulse-reverse electropolishing at Jefferson Lab, together with RF test of cavities being processed. We report the scale-up challenges and interpretations from process R&D to implementation.

Tian, Hui↗

952.6 MHz SRF cavity development for JLEIC

JLab is developing new SRF cavity designs at 952.6 MHz for the proposed Jefferson Lab Electron-Ion Collider (JLEIC). New cavities will be required for the ion ring, cooler ERL and booster and eventually for the electron ring to allow the highest possible bunch collision rate. The challenges include the need for strong HOM damping, high fundamental mode power couplers and high HOM power. Initial focus is on the cooler ERL five- cell cavity as this is a critical component for the strong, high energy, bunched-beam cooling concept. One-cell and five-cell Nb prototype cavities have been designed and fabricated. Details concerning the cavity fabrication and test results for the will be presented.

Rimmer, Robert A.↗

DESIGN OF A HIGH CHARGE, LOW ENERGY, MAGNETIZED ELECTRON INJECTOR

Simulations of a magnetized injector for the bunched-beam electron cooler ring, as part of the Jefferson Lab Electron Ion Collider (JLEIC) are presented. A challenge of such an injector is in generating a magnetized, 3.2nC electron bunch at low energy and preserving the angular momentum so it can subsequently be merged into the cooler ring and transported to the cooling solenoid with-out degradation. The design of the proposed injector and the effect it has on the beam are discussed in detail.

Hannon, Fay↗

Production of magnetized electron beam from a DC high voltage photogun

Bunched-beam electron cooling is a key feature of all proposed designs of the future electron-ion collider, and a requirement for achieving the highest promised collision luminosity. At the Jefferson Lab Electron Ion Collider (JLEIC), fast cooling of ion beams will be accomplished via so-called 'magnetized cooling' implemented using a recirculator ring that employs an energy recovery linac. In this contribution, we describe the production of magnetized electron beam using a compact 300 kV DC high voltage photogun with an inverted insulator geometry, and using alkali-antimonide photocathodes. Beam magnetization was assessed using a modest diagnostic beamline that includes YAG view screens used to measure the rotation of the electron beamlet passing through a narrow upstream aperture. Magnetization results are presented for different gun bias voltages and for different laser spot sizes at the photocathode, using 532 nm lasers with DC and RF time structure. Photocathode lifetime was measured at currents up to 4.5 mA, with and without beam magnetization.

Al Mamun, Md Abdullah↗

A Non-destructive Magnetic Momentum Monitor Using a TE011 Cavity

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam. The bunched beam cooler complex consists of a high current magnetized electron source, an energy recovery linac, a circulating ring, and a pair of long solenoids where the cooling takes place. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we will show the mechanism and scaling law of this device, as well as the design and testing results of the prototype cavity.

Guo, Jiquan↗

Dispersive Electron Cooling for JLEIC

JLEIC is the electron ion collider under design at Jefferson Lab, which will provide a luminosity up to 1034 cm-2s-1. To reach the high luminosity, short ion and electron bunches with high charge density colliding in high frequency are proposed in JLEIC design. The high charge density of the ion beam leads to strong intrabeam scattering effect, which enlarges the ion beam emittance and ruins the luminosity if not mitigated. Magnetized electron cooling is implemented to overcome the intrabeam scattering effect and to reduce or maintain the ion beam emittance. In this paper, we discuss the redistribution of the cooling effects in the longitudinal and the transverse directions by introducing the dispersion of the ion beam in the cooling section. When the charge density of the cooling electron beam varies, the dispersion of the ion beam leads to an increase of the transverse cooling rate and a reduction of the longitudinal cooling rate, while the total decrement of the Courant-Snyder invariant of the ion beam increases. Both theoretical analysis and numerical calculation are presented.

Zhang, He↗

LCLS-II Cryomodules Production at Fermilab

LCLS-II is a planned upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac will consist of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab are currently producing in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW operation. Two prototype cryomodules had been assembled and tested. After prototype cryomodule tests, both laboratories have increased cryomodule production rate to meet the challenging LCLS-II project installation schedule requirements of approximately one cryomodule per month per laboratory. Fermilab is at half point for the production, meaning that 6 cryomodules are fully assembled and tested. This paper presents Fermilab Cryomodule Assembly Facility (CAF) infrastructure for the LCLS-II cryomodules assembly, production experience at the half point emphasizing the challenges and mitigations.

43 PARTICLE ACCELERATORS↗

Status Update of a Harmonic Kicker Development for JLEIC

The Jefferson Lab Electron-Ion Collider (JLEIC) is an asymmetric high luminosity ring-ring collider proposed as the next major R&D facility for the nuclear physics community. Both of JLEIC?s electron and ion collider rings have high beam current with gaps serving the pur-poses of beam abort, ion clearing, etc. Those gaps will cause time-varying beam loading in the storage RF cavi-ties, and may result in modulation of cavity RF phase/voltage and cyclic shift of collision point, which could lead to significant luminosity loss. We studied a few approaches to mitigate the RF phase modulation and IP shift, such as correcting the RF phase/voltage modula-tion with traditional LLRF feedback, one-turn feedback (OTFB), or RF feedforward (FF); optimizing the bunch fill pattern to limit the RF phase/voltage modulation to a small fraction of the bunch trains in the collider ring; or matching the RF phase modulation in the two rings. The preliminary results are discussed in this paper.

Guo, Jiquan↗

PERLE: A High Power Energy Recovery Facility

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Kaabi, W.↗

Dynamic Aperture of JLEIC Electron Collider Ring with Errors and Correction

Design of the electron and ion rings of the Jefferson Lab Electron-Ion Collider (JLEIC) features the low-beta Interaction Regions (IR) with detector solenoid, non-linear chromaticity compensation blocks (CCB), and spin rotator optics with solenoids. The high beta functions in the IR final focus quadrupoles (FFQ) and in the CCB magnets result in strong effects of errors in these magnets. Performance of the spin rotators may also be sensitive to the errors. The first part of this study includes the design of orbit correction system for both rings and evaluation of dynamic aperture (DA) with misalignment and the correction. The second part is devoted to the DA study with the FFQ non-linear field errors. The orbit correction design, the dynamic aperture, and the impact on error specifications are presented.

Lin, F.↗

HIGH CURRENT HIGH CHARGE MAGNETIZED AND BUNCHED ELEC-TRON BEAM FROM A DC PHOTOGUN FOR JLEIC COOLER

A high current, high charge magnetized electron beam-line was developed for fast and efficient cooling of ion beams for the proposed Jefferson Lab Electron Ion Col-lider (JLEIC). In this paper, we describe recent achieve-ments that include the generation of picosecond-bunch magnetized beams at average currents up to 28 mA with exceptionally long photocathode lifetime, and independent demonstrations of magnetized beam with high bunch charge up to 700 pC at 10s of kHz repetition rates. In addition, a detailed description of an extremely stable and reliable fiber-based drive laser system that employs a gain-switched master oscillator is presented. These ac-complishments mark important steps toward demonstrat-ing the feasibility of a technically challenging JLEIC cooler design using magnetized beams

Adderley, P.↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗

EXPERIMENTAL VERIFICATION OF TRANSPARENT SPIN MODE IN RHIC

High electron and ion polarizations are some of the key design requirements of a future Electron Ion Collider (EIC). The transparent spin mode, a concept inspired by the figure 8 ring design of JLEIC, is a novel technique for preservation and control of electron and ion spin polarizations in a collider or storage ring. It makes the ring lattice "invisible" to the spin and allows for polarization control by small quasi-static magnetic fields with practically no effect on the beam’s orbital characteristics. It offers unique opportunities for polarization maintenance and control in Jefferson Lab’s JLEIC and in BNL’s eRHIC. The transparent spin mode has been demonstrated in simulations and we now plan to test it experimentally. We present a design of an experiment using a polarized proton beam stored in one of the RHIC rings. In the experiment, one of the RHIC rings is configured in the transparent spin mode by aligning the axes of its two Siberian snakes. The experiment goals, procedures, hardware requirements and expected results are presented.

Morozov, V.S.↗

FULL ACCEPTANCE INTERACTION REGION DESIGN OF JLEIC

Nuclear physics experiments envisioned at a proposed future Electron-Ion Collider (EIC) require high luminosity of 10^33-10^34 cm^-2s^-1 and a full-acceptance detector capable of reconstruction of a whole electron-ion collision event. Due to a large asymmetry in the electron and ion momenta in an EIC, the particles associated with the initial ion tend to go at very small angles and have small rigidity offsets with respect to the initial ion beam. They are detected after they pass through the apertures of the final focusing quadrupoles. Therefore, the apertures must be sufficiently large to provide the acceptance required by experiments. In addition, to maximize the luminosity, the final focusing quadrupoles must be placed as close to the interaction point as possible. A combination of these requirements presents serious detection, optics and engineering design challenges. We present a design of a full-acceptance interaction region of Jefferson Lab Electron-Ion Collider (JLEIC). The paper presents how this design addresses the above requirements up to an ion momentum of 200 GeV/c. We summarize the magnet parameters, which are kept consistent with the Nb-Ti superconducting magnet technology.

Morozov, V.S.↗

Luminosity Studies of Asymmetric Crab crossing in JLEIC

The proposed Jefferson Lab Electron Ion Collider (JLEIC) currently plans to use a crab crossing scheme to maximize the available luminosity. It had been suggested by that space and cost savings, as well as hadron beam quality improvements could be realized by leaving the ion beam un-crabbed and increasing the crabbing angle of the electron beam. We also examine the two bunches crabbed at different angles, as well as at different crabbing frequencies to determine the maximum achievable luminosity for both JLEIC and LHC parameters.

Nissen, Edith↗

Superconducting Radio-frequency Cavity Fault Classification Using Machine Learning at Jefferson Laboratory

We report on the development of machine learning models for classifying C100 superconducting radiofrequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Of the 418 SRF cavities in CEBAF, 96 are designed with a digital low-level RF system configured such that a cavity fault triggers recordings of RF signals for each of eight cavities in the cryomodule. Subject matter experts analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time - rather than postmortem - identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the machine learning models during a recent physics run. We also discuss efforts for further insights into fault types through unsupervised learning techniques and present preliminary work on cavity and fault prediction using data collected prior to a failure event.

Tennant, C. D.↗