Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Improvement of Front-Junction GaInP by Point-Defect Injection and Annealing: Preprint

Traditional front junction GaInP solar cells are radiation tolerant and can have good diffusion length, but have limited voltage and thus efficiency. Here, we investigate the impact of annealing on GaInP device performance. First, Zn-doped GaInP/AlGaInP double heterojunction structures are studied in order to investigate the impact of annealing in a simple structure. While standard anneals lower diffusion length and lifetime, annealing after injecting point-defects improves material quality, presumably by eliminating sources of non-radiative recombination. Atomic ordering is reduced by the anneal, which raises the device bandgap and requires consideration. These results can be used to improve front junction device performance while controlling the bandgap. Then, GaInP front-junction devices are created using anneals with and without point-defect injection. Voc and EQE trends follow the diffusion length and lifetime trends from the DH structures. Baseline devices have Woc of 0.484 V, raising to 0.504 V after a high temperature anneal. However, injecting point defects prior to the anneal results in a front junction device with Woc of 0.405 V and a diffusion length greater than 8 micrometers. Optimized front-junction GaInP devices with an ARC have ~20% efficiency without a rear reflector.

anneal↗

Pressurized damping fluid injection for damping turbine blade vibration

A blade vibration damping system impacts a pressurized damping fluid on a surface of at least one of a plurality of blades of a turbine in opposition to a vibratory movement thereof to cause damping of vibration of the blade(s) during operation of the turbine. The system includes a fluid injection nozzle in a stationary component adjacent the plurality of blades. A valve selectively admits the pressurized damping fluid to the fluid injection nozzle from a source of pressurized damping fluid, and a control system controls the valve to operate the fluid injection nozzle in response to an operational parameter exceeding a threshold during operation of the turbine. A related turbine casing and method are also provided.

Delvaux, John McConnell↗

Injection of a Self-Consistent Beam at the Spallation Neutron Source

We plan to demonstrate the injection of a self-consistent beam into the Spallation Neutron Source (SNS). Self-consistent beams are defined to be ellipsoidal distributions with uniform density and to retain these properties under all linear transformations. Self-consistent distributions may generate very little halo if realized in practice. Some may also be manipulated to generate flat beams. Self-consistent distributions involve very special relationships between the phase space coordinates, making them difficult to realize experimentally. One self-consistent distribution, the 2D rotating distribution, can be painted into the SNS ring, with slight modification of the lattice. However, it is unknown how robust self-consistent distributions will be under real world transport in the presence of nonlinearities and other collective effects. This paper studies these issues and the mitigation of unwanted effects by applying realistic detailed computational models to the simulation of the injection of rotating beams into SNS. The result is a feasible prescription for the injection of a rotating self-consistent distribution into the SNS ring.

Holmes, Jeffrey↗

Cryo nanomanipulator probe with integrated gas injection

A probe assembly for use with a charged particle instrument includes an elongate body having a proximal end for positioning outside of a charged particle instrument enclosed environment, a distal end for positioning within the enclosed environment and a longitudinal axis. A port interface is located on the body between the proximal and distal ends, and is coupleable to a nanomanipulator system of the charged particle instrument. A probe needle is positioned at a distal end of the body and is selectively positionable from outside the enclosed environment to contact a specimen within the enclosed environment. At least one gas injection needle is adjustably positioned near the probe needle. The gas injection needle is connectable to a source of pressurized gas to selectively inject gas in the area of the probe needle within the enclosed environment.

Perea, Daniel E.↗

Time Lapse Charged Wellbore Casing Controlled Source Electromagnetic Surveys for Monitoring Injected Carbon Dioxide

Carbon dioxide (CO2) injection for enhanced oil recovery (EOR) and long-term carbon storage extends the life of an oil field while keeping CO2 out of the atmosphere. Monitoring CO2 migration during EOR operations is critical to maximizing production and detecting unexpected CO2 migration quickly. In this project, we monitor CO2 migration using time-lapse charged well casing controlled source electromagnetics (CSEM) at an active EOR site undergoing CO2 injection. Since the electrical conductivity of the reservoir changes as CO2 displaces other fluids, this novel survey technique aims to monitor CO2 injection effectively and unobtrusively from the surface via electromagnetic field measurements. Of four time-lapse field campaigns spaced over two years, we have completed two. Each campaign consists of a CSEM survey supplemented by magnetotelluric and time-domain electromagnetic surveys. In the CSEM survey, a transmitter delivers alternating current to the subsurface at frequencies from 0.125 Hz to 16 Hz using steel well casings as electrodes. Charged well casing surveys detect deeper conductivity contrasts than surveys that use only surface electrodes, allowing CO2 movement at the depth of the reservoir to be imaged more clearly. We transmit on two well pairs. One pair is oriented in the east-west direction, and the other is oriented in the northeast-southwest direction. Receiver stations measure orthogonal components of the electric and magnetic fields. The measurements are repeated at the same locations in each field campaign. Data differences between campaigns provide information about changes in the electrical conductivity of the subsurface. We present the latest results from this ongoing project, including modeling, survey design, data processing techniques, and preliminary results from the field campaigns.

Magnetic and electrical methods, Geomagnetic induc↗

An improved synthetic signal injection routine for HAYSTAC

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of 10-24 W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion's spectral distribution, which is derived from a Maxwell-Boltzmann distribution. In addition, we show that the synthetic axion's power can be calibrated with reference to the system noise. Compared to the synthetic axion injection in HAYSTAC phase I, we demonstrated synthetic signal injection with a more realistic lineshape and calibrated power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long fiber injection molding

An improved method for obtaining high fiber volume fraction, long fiber injection molded articles is provided. According to one embodiment, the method includes forming an injection molding feedstock by cutting pre-impregnated fiber-reinforced tape into platelets. The platelets can be coated with a thin layer of polymer to allow sliding of the platelets with respect to each other at the early stages of plastication, rather than forcing relative motion of fibers with respect to each other. The method can further include the dispersion of material only in the final stages of the injection molding screw to promote gentle motion of the feedstock at the earlier stages of the plastication process. The method allows improvement of mechanical properties of articles manufactured with equipment and techniques that are prevalent in high volume automotive and consumer industries.

Kunc, Vlastimil↗

Remote Evaporator Vessel Repair by Robotics and Powder Injection Laser Welding - 18107

In February 2016 a leak was identified in the 25H evaporator at the Savannah River Site (SRS). The 25H evaporator is used to manage water volume in high level waste (HLW) tanks during solid salt cake and sludge removal. The location and the cause of the leak were unknown. Orano Federal Services (formerly AREVA Federal Services) applied its robotics expertise and commercial nuclear expertise to perform the inspection. Orano and Framatome (formerly AREVA NP INC) combined a BROKK, a commonly used tracked vehicle with remote control, with the KUKA, an automated robotic arm, commonly used in automobile manufacturing, to perform the partial dismantlement and inspection. Once inspection was complete and the leak was identified, Orano conducted a study on two welding processes: Gas Tungsten Arc (GTA-Tig) and Powder Injection Laser Welding. Based on the inspection of the SRS HLW evaporator's material type being Hastelloy{sup R}, along with the remote repair and material thin wall condition, the Powder Injection Laser Welding was chosen for this application. Orano has developed the remote powder injection laser welding and delivery process that will be used to conduct the repair of the SRS HLW evaporator in the fall of 2017. The process includes robotic delivery of components and robotic performance of the weld. Specialized robotic equipment were developed or adapted from other industries to perform the high hazard job of repairing an eroded section of the evaporator pot. The integration of multiple innovative remote techniques provides a unique solution in a highly radioactive environment. These techniques and innovations can be capitalized upon to solve many different remote repairs on equipment resulting in time savings, reduced dose to personnel, and recovery of initial investment in equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving the cross correlation method of indirect flow measurement by water injection and modeling - 245

This paper presents a technique to improve the Cross Correlation Function (CCF) method for indirect flow measurement. Unlike other methods, the CCF method does not need a specific instrument or tool for flow measurements. Instead, the delay time between two sensors can be derived by applying the CCF. A water flow loop was constructed to investigate the CCF method for flow measurement. Because the inherent process temperature variations were small when compared to significant amounts of measurement and process noise, inaccurate flow measurements were obtained. The performance of the CCF method could be improved by increasing the system signal-to-noise ratio, which is the process noise divided by the measurement noise. For this reason, a periodic injection of different temperature water was used to increase the process temperature variation. The results were favorable. However, several design variables needed to be selected. To assist, a CFD simulation was utilized to optimize the distance between sensors and injection point, the rate of injection flow, and other related variables. The results show that CCF optimization of these variables produces better flow measurement performance over a range of flow velocities. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Workflow for Coupled Simulation of Hydraulic Stimulation with Simultaneous Injection of Proppant

Enhanced Geothermal Systems (EGS) are located in impermeable host rock. Therefore, to achieve promising circulation, hydraulic stimulation is a key factor. Stimulation involves injecting a combination of fluids and proppant particles into existing fractures under high pressure. The effectiveness of stimulation depends on a variety of different factors, including the pressurization scheme and the optimal choice of carrying fluid and proppant particles to be used. For example, high-density particles can settle out of the injected slurry quickly, whereas lighter particles as well as a dense carrying fluid allow for a long transport into the reservoir. A numerical tool is therefore essential to take all these factors into account and to make robust predictions about the performance of the hydraulic stimulation. We present a novel computational application for coupled numerical simulation of hydraulic stimulation with concurrent injection of proppant in a fractured geothermal reservoir. This application is based on the open-source MOOSE framework that has been enriched with a set of equations to account for the circulation of proppant-laden slurries. It accounts for both the fluid and proppant components of the mixture, as well as particle-driven processes that include gravity settling, particle-particle interactions, and strong density and viscosity contrasts. A particular challenge is the mutual coupling with fracture mechanical processes in a propagating fracture using the FE code Defmod. Aperture and fluid pressure on one side and slurry density and viscosity changes on the other side interact and affect each other. Their basic understanding is therefore essential for the success of the stimulation. We compare our application to common numerical benchmark problems for both slurry flow and hydraulic stimulation.

15 GEOTHERMAL ENERGY↗

Investigation of Scale Deposition and Wellbore Corrosion in Carbonated Brine Injection: A Simulation Study

Carbonated brine injection (CBI), which involves dissolving CO2 in produced water to be injected into deep geologic reservoirs, is a method to manage produced brine, carbon dioxide (CO2) sequestration, and reduce anthropogenic greenhouse gas emissions. This low-risk CO2 storage strategy can leverage the existing saltwater disposal infrastructure and well resources. However, the potential for corrosion and scale deposition are a major challenge for carbonated brine which may result in subsidence, wellbore failure, casing failure, and cement failure. The main objective of this research was to evaluate the wellbore materials compatibility with carbonated brine water during the injection process, for repurposing Class II saltwater disposal wells for CBI.

Belarbi, Zineb↗

Fracture Network Quantification during CO2 Injection

This is the conference paper accompanying an oral presentation at the ARMA 2025 (59th US Rock Mechanics/Geomechanics Symposium) Conference held in Santa Fe, New Mexico, June 8-11, 2025. Accurate mapping and quantification of these networks are essential to ensure the integrity of CO2 storage reservoirs, understand and reduce potential leakage, and maintain long-term environmental safety. This study presents a novel machine learning-driven approach, integrated with geomechanical analysis, to quantify fracture networks and assess their spatial distribution during CO2 injection. This paper combines microseismic monitoring data with principles of hydraulic diffusivity and geomechanical analysis to characterize reservoir scale fracture network. The novelty of our approach lies in its capacity to assimilate time-dependent pressure data and microseismicity into a cohesive framework, which not only identifies microseismic triggering fronts but also tracks fracture distribution during active injection. Besides, leveraging image log data and analysis our approach also provides another angle of the insights to solidate the fracture networks understanding and geomechanical impacts. Key results from our study include the detection of over 100 distinct fracture clusters across the injection site, with fracture orientations strongly correlated with the prevailing in-situ stress field.

CO2 storage and sequestration↗

Injection simulations of space charge dominated proton beams in IOTA

A 2.5 MeV proton injector is being constructed for the IOTA ring at Fermilab to study the interaction of nonlinear integrable optics (NIO) with high space charge beams. Space charge in the transport line from the RFQ to the injection location has a significant current dependent effect on the phase space. Simulation studies to support efficient injection of intense bunches into IOTA are presented, included schemes to inject directly into NIO lattices.

Wieland, J. [Fermilab; Michigan State U.] (ORCID:0↗

Injection Related Background due to the Transverse Feedback

The background in the BaBar detector is especially high during injection, when most components are actually having reduced voltages. The situation is worse for the beam in High Energy Ring (HER) when the LER beam is present. It was found that the transverse feedback system plays an important role when stacking more charge on top of existing bunches. Lowering the feedback gain helped and it was realized later that the best scenario would be to gate off the feedback for only the one bunch, which got additional charge injected into it. The explanation is that the blown-up, but centered, original HER bunch plus the small injected off-axis bunch (each with half the charge) would stay in the ring if not touched, but the feedback system sees half the offset and wants to correct it, therefore disturbing and scraping the blown-up part.

43 PARTICLE ACCELERATORS↗

Injection and acceleration of Au31+ in the BNL AGS.

Injection and acceleration of ions in a lower charge state reduces space charge effects, and, if further elcctron stripping is needed, may allow elimination of a stripping stage and the associated beam losses. The former is of interest to the accelerators in the GSI FAIR complex, the latter for BNL RHIC collider operation at energies lower than the current injection energy. Lower charge state ions, however, have a higher likelihood of electron stripping which can lead to dynamic pressures rises and subsequent beam losses. We report on experiments in the AGS where Au{sup 31+} ions were injected and accelerated instead of the normally used Au{sup 77+} ions. Beam intensities and the average pressure in the AGS ring are recorded, and compared with calculations for dynamic pressures and beam losses. The experimental results will be used to benchmark the StrahlSim dynamic vacuum code and will be incorporated in the GSI FAIR SIS100 design.

43 PARTICLE ACCELERATORS↗

Minimizing emittance growth during H- injection in the AGS booster

As part of the efforts to increase polarization and luminosity in RHIC during polarized proton operations we have modified the injection optics and stripping foil geometry in the AGS Booster in order to reduce the emittance growth during H{sup -} injection. In this paper we describe the modifications, the injection process, and present results from beam experiments.

43 PARTICLE ACCELERATORS↗

Neutral beam injection with an improved accelerator for LHD

The beam profiles, port-through, rates and injection powers obtained with an improved accelerator with the multislot grounded grid are described. The accelerator has a combination of a steering grid with racetrack shaped aperture and multislot grounded grid to improve the beam optics. The optimal beam optics is obtained at the voltage ratio of 16.5-16.8, and the profiles are well fit by superposing multibeamlets with the divergent angles of 5.0 and 7.2 mrad along the direction parallel to the long and short axes of the slots of grounded grid. By adopting the racetrack shaped steering grid, the port-through rate increases from 34% to 38%, and the maximum injection power reaches 6 MW/187 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Study of Spectral Lines in Plasmas Heated by Neutral Beam Injection in the TJ-II Stellarator

We summarize the TJ-II stellarator device give an outline of a vacuum ultraviolet spectrometer used for performing spectral surveys specialized plasma studies. Next, we report the main impurities observed in hot plasmas created maintained by electron cyclotron resonance neutral beam injection heating with lithium coated wall conditioning. Finally, we report broad emission structures that have been observed close to strong oxygen emission lines during neutral beam injection heating phases we elucidate their possible origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗