Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results

The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.

Goldberg, A.↗

Hydrogen/Air Fuel Nozzle Emissions Experiments

The use of hydrogen combustion for aircraft gas turbine engines provides significant opportunities to reduce harmful exhaust emissions. Hydrogen has many advantages (no CO2 production, high reaction rates, high heating value, and future availability), along with some disadvantages (high current cost of production and storage, high volume per BTU, and an unknown safety profile when in wide use). One of the primary reasons for switching to hydrogen is the elimination of CO2 emissions. Also, with hydrogen, design challenges such as fuel coking in the fuel nozzle and particulate emissions are no longer an issue. However, because it takes place at high temperatures, hydrogen-air combustion can still produce significant levels of NOx emissions. Much of the current research into conventional hydrocarbon-fueled aircraft gas turbine combustors is focused on NOx reduction methods. The Zero CO2 Emission Technology (ZCET) hydrogen combustion project will focus on meeting the Office of Aerospace Technology goal 2 within pillar one for Global Civil Aviation reducing the emissions of future aircraft by a factor of 3 within 10 years and by a factor of 5 within 25 years. Recent advances in hydrocarbon-based gas turbine combustion components have expanded the horizons for fuel nozzle development. Both new fluid designs and manufacturing technologies have led to the development of fuel nozzles that significantly reduce aircraft emissions. The goal of the ZCET program is to mesh the current technology of Lean Direct Injection and rocket injectors to provide quick mixing, low emissions, and high-performance fuel nozzle designs. An experimental program is planned to investigate the fuel nozzle concepts in a flametube test rig. Currently, a hydrogen system is being installed in cell 23 at NASA Glenn Research Center's Research Combustion Laboratory. Testing will be conducted on a variety of fuel nozzle concepts up to combustion pressures of 350 psia and inlet air temperatures of 1200 F. Computational fluid dynamics calculations, with the Glenn developed National Combustor Code, are being performed to optimize the fuel nozzle designs.

Smith, Timothy D.↗

Pharmacodynamics of Promethazine in Human Subjects

Promethazine (PMZ) is the drug of choice for the treatment of symptoms associated with space motion sickness in astronauts. Side effects of PMZ include sedation, dizziness and cognitive performance impairment. In this study, we examined pharmacodynamics (PD) in human subjects and validated methods for evaluating cognitive performance effects of medications in space. METHODS: PMZ (12.5,25, and 50 mg) or placebo was administered by IM injection to human subjects in a randomized double-blind treatment design. Samples and data were collected for 72 h post dose. PD evaluation was performed using a battery of performance tests administered using WinSCAT (Windows based Space Cognitive Assessment Test) on a laptop computer, and ARES (ANAM Readiness Evaluation System) on a PDA, plasma concentrations of PMZ were measured using a LC-MS method. RESULTS: Results indicate a linear correlation between PMZ concentration and cognitive performance parameters (p<0.01). Test accuracy decreased and test completion time and response time increased significantly with increasing plasma PMZ concentration. CONCLUSIONS: These results suggest a concentration dependent decrement in cognitive performance associated with PMZ. WinSCAT and ARES are sensitive tools for the assessment PMZ PD and may be applicable for such evaluations with other neurocognitive drugs.

Gatlin, K. T.↗

Numerical Investigation of the Effect of Cooling Airflow inside High-Pressure Turbine using the Source Term Approach

In this study, the Open National Combustion code (OpenNCC) is applied to simulate the airflow inside the high-pressure turbine (HPT) of the energy efficient engine (EEE). The main objective of this study is to compare the characteristics of the HPT performance obtained by using three different approaches (Case 1: the realistic combustion products are considered at the HPT inlet, but the cooling airflows are not included, Case 2: the working fluid is assumed to be a single gas (i.e., air), and the cooling airflows are considered, Case 3: the cooling airflow and the combustion products at the HPT inlet are included). To mimic the cooling airflows at the HPT surface, we use the surface source team approach, in which we impose the source term at a specific area of a cooling airflow hole at the solid surfaces by specifying an injection angle, temperature, turbulent intensity, and mass flowrate of each cooling airflow. For the validation of the model, the data for the EEE model was obtained from the General Electric (GE) test campaign (RDG10), and the full scale warm-air rig test condition representing a test point close to the integrated core/low spool design condition was considered. This validation test was done using the stationary uniform inflow condition (i.e., the reported total temperature and total pressure). Secondly, we considered the Sea-Level Take-off (SLTO) engine condition and separately performed the combustor simulation to obtain a more realistic time-averaged, spatially-nonuniform HPT inflow condition. This work provides a better understanding the effect of the cooling airflow model with different assumptions on the HPT performance. It is found that using different working gas have a minor effect on the performance metric, however the presence of the cooling airflows significantly affects the HPT performance such as the turbine efficiency.

CFD Hot-streaks↗

Application of an Embedded Fracture and Borehole Modeling Approach to the Understanding of EGS Collab Experiment 1

EGS Collab is a series of meso-scale experiments and associated numerical simulation activities being funded by the United States Department of Energy, Geothermal Technologies Office (GTO) to investigate enhanced geothermal system processes under in-situ stress and slightly elevated temperature conditions. This project is designed to provide scientists and engineers with immediate access to impermeable rock at scales larger than possible in the laboratory, but generally smaller than those for commercial production. Immediate access to rock is provided via the existing drifts of the former Homestake Gold Mine, now operated as the Sanford Underground Research Facility in Lead, South Dakota. The objectives of the EGS Collab project are to develop well controlled fracture networks between injector and producer boreholes using normal and shear stimulation for permeability enhancement. The first experimental site was located off the West Access drift on the 4850 Level (4850 feet below ground surface) in phyllite of the Precambrian Poorman formation, and involved the creation of a fracture network comprising a combination of hydraulic and natural fractures. A second experimental site is now being considered near the battery alcove on the 4100 Level in amphibolite and rhyolite of the Yates Unit. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. Experiment 1 has comprised a series of successful tests, including a long-term chilled-water circulation test, but the testbed has two atypical EGS elements. Active ventilation in the adjacent drift over a 50-year period cooled the testbed rock mass and hydraulic fracturing intersected monitoring boreholes making them conduits for fluid flow. Numerical simulations executed in support of the design of the EGS Collab Experiment 1, computed a radial temperature distribution and stress gradient orthogonal to the drift axis, resulting in the forecast of an oblong hydraulic fracture geometry, extended in the direction of the drift from the stimulation borehole. This paper describes the numerical simulation of long-term chilled-water circulation test with an embedded fracture and borehole modeling approach. The principal objective of the simulation work is show agreement between experimental observations in terms of production fluid temperatures, monitoring borehole temperatures, injection and production pressures, and tracer recoveries using a single conceptual model for the fracture network, using characterization and monitoring data generally available for EGS. A secondary objective is to improve the numerical simulation result comparisons with additional data available from the broader monitoring equipment within the testbed versus deeper, hotter, and more remote EGS. One complicating factor for comparisons between the numerical simulation results and experimental observations, is the Joule-Thomson heating associated with large pressure drops across the fracture network.

numerical simulation, embedded fractures and boreh↗

The Use of Silver Chloride Injection in Remediation of Iodine-129 by In Situ Capture as Silver Iodide at the F-Area Seepage Basin - 20225

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. As part of operations, the F-Area Seepage Basins operated until 1988 for the disposition of deionized acidic wastewater from the F Separations Facility. The wastewater contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The seepage basins were closed in 1988 and backfilled and capped by 1991. The groundwater emanating from beneath the closed and capped seepage basins is acidic and contains elevated levels of both chemical and radiological contaminants. Releases from the groundwater plumes sourced from the F-Area Seepage Basins have impacted the water quality of Fourmile Branch, which is a small tributary to the Savannah River, a regional water source. A large pump-and-treat system was constructed in 1997 and operated until 2003 in an attempt to capture the releases to Fourmile Branch. The system in F Area and a similar system in H Area were expensive (∼$1.3 M/month) to operate and produced large quantities of radioactive waste, with concentrations of I- 129 too high to be disposed of at the SRS. In 2004, SRS replaced pump-and-treat with a funnel and gate system that along with operation of a base injection system at the gates reduces the flux of contaminants to the wetlands adjacent to Fourmile Branch. The alkaline solution injected into the aquifer neutralizes the acidic plume and immobilizes many of the cationic constituents. However, base injection is not effective in managing the release of iodine-129, an anionic contaminant. To address iodine-129 SRS and the Savannah River National Laboratory developed an in situ technology that uses ultra-fine ground silver chloride (AgCl) as an injectable capture medium for the sequestration of iodine-129. The AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture iodine-129. Dissolved iodine-129 forms a stable and highly insoluble solid (silver iodide) upon contact with AgCl. Laboratory studies, a field scale pilot test (2009), and three deployments (2011, 2015 and 2019) of AgCl have been successfully performed at the F-Area Seepage Basins. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active Flow Control Enhanced Aileron of the High-Lift Common Research Model at Takeoff Condition

An experimental investigation was conducted in the NASA Langley 14- by 22-Foot Subsonic Tunnel on the NASA 10% scale High-Lift Common Research Model (CRM-HL) to improve the high-lift aerodynamic performance of the takeoff configuration. Active flow control (AFC) was applied at the aileron hinge line to control flow separation at high aileron deflection angles to increase lift-to-drag ratio (L/D). Improvements in low speed L/D can increase vehicle payload and/or range resulting in a more efficient vehicle. Aileron deflection angles of 0°, 7.5°, 16°, and 25° were investigated. Flow control was applied to the two largest aileron deflections, which are considered the high-lift (HL) improved takeoff configurations. A companion paper will discuss baseline flow characteristics of the CRM-HL at the three takeoff conditions: reference, nominal, and HL-improved. In this paper, we focus on the aerodynamic improvement obtained when AFC was applied to an aileron deflected at 16° relative to the nominal configuration of 7.5° deflection. Multiple flow control parameters, including actuator type, spacing, and intensity, were investigated to evaluate the efficiency of the actuation system. The different AFC configurations tested were assessed with tuft visualization, steady surface pressure data, and force and moment data. The results indicated that all actuation types and spacings examined led to an increase in lift across the range of angles of attack investigated. Flow separation was mitigated with the injection of momentum at the aileron hinge line. The configurations with the smallest spacing produced the highest improvement in L/D. Steady jet actuation showed higher efficiency but similar aerodynamic performance when compared to the sweeping jet actuators. This work was performed in support of the NASA Advanced Air Transport Technology (AATT) Project.

CRM-HL↗

Lean-Stratified Combustion System with Miller Cycle for Downsized Boosted Application - Part 2

Automotive manufacturers relentlessly explore engine technology combinations to achieve reduced fuel consumption under continued regulatory, societal and economic pressures. For example, technologies enabling advanced combustion modes, increased expansion to effective compression ratio and reduced parasitics continue to be developed and integrated within conventional and hybrid propulsion strategies across the industry. Here, a high-efficiency gasoline engine capable for use in conventional or hybrid electric vehicle platforms is highly desirable. This paper is the second of two papers describing the multi-cylinder integration of a technology package combining lean-stratified combustion with Miller cycle for downsized boosted applications. The first paper describes the design, analysis and single-cylinder testing conducted to down-select the combustion system deployed to the multi-cylinder engine. This paper defines a light-duty engine package capable of achieving a 35% fuel economy improvement at US Tier 3 emission standards over a naturally aspirated stoichiometric baseline vehicle. A multi-mode combustion system was developed enabling highly efficient lean-stratified operation at light-load and stoichiometric Miller-cycle operation at mid- to high-loads. A central direct-injection four-valve layout was designed with high-tumble ports and a bowl-in-piston capable of stable operation under highly dilute mixtures when properly matched to fuel spray characteristics, injection strategy, and a high-energy ignition system. Boost system layout and base engine architecture were selected to minimize parasitics and maximize after treatment effectiveness. A multi-cylinder engine was developed and calibrated over a steady-state map. Results fed vehicle simulations over the EPA city and highway test cycles to predict the fuel economy improvement and tailpipe emissions potential. Fuel economy improvements over the baseline vehicle were projected at 42% and 39% for active-urea and passive-ammonia SCR after treatment systems respectively. Controls complexity to achieve regulatory compliance and the cost of the lean after treatment system were identified as the primary challenges to commercial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Boundary-Layer Detection at Cryogenic Conditions Using Temperature Sensitive Paint Coupled with a Carbon Nanotube Heating Layer

Detection of flow transition on aircraft surfaces and models can be vital to the development of future vehicles and computational methods for evaluating vehicle concepts. In testing at ambient conditions, IR thermography is ideal for this measurement. However, for higher Reynolds number testing, cryogenic facilities are often used, in which IR thermography is difficult to employ. In these facilities, temperature sensitive paint is an alternative with a temperature step introduced to enhance the natural temperature change from transition. Traditional methods for inducing the temperature step by changing the liquid nitrogen injection rate often change the tunnel conditions. Recent work has shown that adding a layer consisting of carbon nanotubes to the surface can be used to impart a temperature step on the model surface with little change in the operating conditions. Unfortunately, this system physically degraded at 130 K and lost heating capability. This paper describes a modification of this technique enabling operation down to at least 77 K, well below the temperature reached in cryogenic facilities. This is possible because the CNT layer is in a polyurethane binder. This was tested on a Natural Laminar Flow model in a cryogenic facility and transition detection was successfully visualized at conditions from 200 K to 110 K. Results were also compared with the traditional temperature step method.

Goodman, Kyle Z.↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

$\mathrm{T}$ransient $\mathrm{CHI}$ System Design Studies for $\mathrm{P}$ EGASUS -$\mathrm{III}$

We report transient coaxial helicity injection (transient CHI), first developed on the Helicity Injected Torus-II (HIT-II) and later on the National Spherical Torus Experiment (NSTX) for implementing solenoid-free plasma current startup capability in a spherical tokamak (ST), is now planned to be tested on the Pegasus-III ST using a novel double-biased configuration. Such a configuration is likely needed for transient CHI deployment in a reactor. The transient CHI system optimization will be studied on Pegasus-III to enable startup toroidal persisting currents at the limits permitted by the external poloidal field coils. A transient CHI discharge is generated by driving injector current along magnetic field lines that connect the inner and outer divertor plates on one end of the ST. Simulations using the Tokamak Simulation Code are used to assess the transient CHI toroidal current generation potential and electrode gap location on the Pegasus-III. While past transient CHI systems have used high-voltage, oil-filled capacitors for driving the injector current, for improved safety, Pegasus-III will use a high-current capacitor bank based on low-voltage electrolytic capacitors. The designed and fabricated system is capable of over 32 kA. The modular design features permit the system to be upgraded to higher currents, as needed, to meet the future needs of the Pegasus-III facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Considerations for the Implementation of a High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (T-CHI), a method first developed on the small helicity injected torus (HIT-II) experiment and then validated on the much larger National Spherical Torus Experiment (NSTX) device, is a method to initiate an inductive-like tokamak plasma discharge without reliance on the central solenoid. A CHI discharge is initiated by driving current along magnetic flux that connects the inner and outer divertor plates on one end of the tokamak. To permit this, on both HIT-II and NSTX, toroidal ceramic insulators were used to electrically separate the inner and outer vessel components. The use of such large toroidal vacuum insulators may not be easy to implement in reactors. To address this issue, the Q-shu University experiments with steady-state spherical tokamak (ST) (QUEST) is developing a reactor-relevant CHI configuration in which one of the divertor plates is electrically insulated from the rest of the vessel. The first application of T-CHI on QUEST biased the CHI electrode to the outer vessel. While the CHI discharges could be easily generated, it was found that as the discharge filled the vessel, the separation distance between the injector magnetic flux footprints widened, a condition that is not favorable for the generation of closed flux surfaces. Biasing the electrode to the inner wall is a configuration similar to that used on NSTX and HIT-II, but initial testing in this configuration has proved to be challenging. The design described here overcomes the present limitation by locating the CHI electrode much closer to the CHI injector flux coil and using an NSTX-like gas injection manifold to enable high-field-side T-CHI startup on QUEST. Finally, the concepts described in this article should also benefit the future implementation of T-CHI systems in other tokamaks and spherical tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

Inference of Induced Fracture Geometries Using Fiber-Optic Distributed Strain Sensing in Hydraulic Fracture Test Site 2

Fiber-optic Distributed Strain Sensor observations in a vertical well allow rapid inference of the time evolution of nearby hydraulic fracture heights and their vertical aperture distributions during stimulation and depressurization. We describe a computationally efficient deconvolutional model based on an elastostatic kernel for fracture opening within an isotropic, homogeneous, linear elastic medium. Furthermore, an application of this model to observations from the Hydraulic Fracture Test Site 2 reveals that ultimate fracture heights are typically greater than those indicated by microseismic monitoring, and some hydraulic fractures continue their upward growth for several hours after high-pressure injections ceased.

58 GEOSCIENCES↗

Nanoparticle Injection Technology for Remediating Leaks of CO 2 Storage Formation (Final Report)

Leakage of a well can occur through the wellbore, the annulus between well tubing and steel casing, or on the outside of the casing. The overall goal of the project is to develop a new technology that can repair or reduce the leakage of wellbore. The new technology is based on simultaneously injecting nanoparticles electrochemically and removing some of the harmful ions in the system so the distressed cement materials can be densified and the corrosion risk of steel casing can be reduced. There were two objectives. One is the development of the injection technology for leakage repair and the other is the development of new numerical simulation models that can simulate and predict the performance of the new repair technology. An electro-migration testing unit and a in-house wellbore testing system were developed; healing agents with nanoparticles were selected, numerical models were developed to simulate the electro-migration technology, and the effectiveness of the new technology were evaluated.

42 ENGINEERING↗

Nanoparticle Injection Technology for Remediating Leaks of CO 2 Storage Formation (Final Technical Report)

Leakage of a well can occur through the wellbore, the annulus between well tubing and steel casing, or on the outside of the casing. The overall goal of the project is to develop a new technology that can repair or reduce the leakage of wellbore. The new technology is based on simultaneously injecting nanoparticles electrochemically and removing some of the harmful ions in the system so the distressed cement materials can be densified and the corrosion risk of steel casing can be reduced. There were two objectives. One is the development of the injection technology for leakage repair and the other is the development of new numerical simulation models that can simulate and predict the performance of the new repair technology. An electro-migration testing unit and an in-house wellbore testing system were developed; healing agents with nanoparticles were selected, numerical models were developed to simulate the electro-migration technology, and the effectiveness of the new technology was evaluated.

42 ENGINEERING↗

Response of local vascular volumes to lower body negative pressure stress

The present study involved an intravenous injection of radioactive iodinated serum albumin, equilibration of this isotope within the vascular space, and the continuous measurement of isotope activity over selected anatomical areas before, during and following multiple human LBNP tests. Both rate and magnitude of vascular pooling were distinctly different within each of five selected lower body anatomical areas. In the upper body, all areas except the abdomen showed depletions from their resting vascular volumes during LBNP. The presence of uniquely different pooling patterns in the lower body, the apparent stability of abdominal vascular volumes, and a possible decrease in cerebral blood volume during LBNP represent the major findings of this study.

Wolthuis, R. A.↗

EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.