Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anisotropic and Interconnected Nanoporous Materials from Randomly End-Linked Copolymer Networks

Microphase separation within randomly end-linked copolymer networks (RECNs) provides access to disordered bicontinuous morphologies over a wide composition range of the constituent network strands. Here, we rely on end-linking of telechelic hydroxyl-terminated polystyrene (PS) and poly(D,Llactide) (PLA) chains of equal molecular weight, with a tetrafunctional isocyanate cross-linker in a good solvent for both strands, followed by solvent removal to induce microphase separation, and finally etching of the PLA phase to yield nanoporous materials. Transmission electron microscopy (TEM) tomographic reconstructed 3D images along with gravimetric measurements and small-angle X-ray scattering (SAXS) indicate the formation of highly interconnected structures over a range of ~40-70 vol % of PLA, while N2 adsorption measurements indicate narrowly distributed pore sizes that can be tuned by varying the strand molecular weights. Stretching of the PS/PLA copolymer networks above the glass transition temperatures of both components prior to etching the PLA phase provides a straightforward means to introduce controlled anisotropy into the 3D interconnected porous materials.

36 MATERIALS SCIENCE↗

Bayesian Learning of Adatom Interactions from Atomically Resolved Imaging Data

Atomic structures and adatom geometries of surfaces encode information about the thermodynamics and kinetics of the processes that lead to their formation, and which can be captured by a generative physical model. In this work, we develop a workflow based on a machine-learning-based analysis of scanning tunneling microscopy images to reconstruct the atomic and adatom positions, and a Bayesian optimization procedure to minimize statistical distance between the chosen physical models and experimental observations. We optimize the parameters of a 2- and 3-parameter Ising model describing surface ordering and use the derived generative model to make predictions across the parameter space. For concentration dependence, we compare the predicted morphologies at different adatom concentrations with the dissimilar regions on the sample surfaces that serendipitously had different adatom concentrations. The proposed workflow can be used to reconstruct the thermodynamic models and associated uncertainties from the experimental observations of materials microstructures. The code used in the manuscript is available at https://github.com/saimani5/Adatom_interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined synchrotron X-ray tomography and X-ray powder diffraction using a fluorescing metal foil

This study realizes the concept of simultaneous micro-X-ray computed tomography and X-ray powder diffraction using a synchrotron beamline. A thin zinc metal foil was placed in the primary, monochromatic synchrotron beam to generate a divergent wave to propagate through the samples of interest onto a CCD detector for tomographic imaging, thus removing the need for large beam illumination and high spatial resolution detection. Both low density materials (kapton tubing and a piece of plant) and higher density materials (Egyptian faience) were investigated, and elemental contrast was explored for the example of Cu and Ni meshes. The viability of parallel powder diffraction using the direct beam transmitted through the foil was demonstrated. The outcomes of this study enable further development of the technique towards in situ tomography/diffraction studies combining micrometer and crystallographic length scales, and towards elemental contrast imaging and reconstruction methods using well defined fluorescence outputs from combinations of known fluorescence targets (elements).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NIFTY way of Bayesian signal inference

We introduce NIFTY, 'Numerical Information Field Theory', a software package for the development of Bayesian signal inference algorithms that operate independently from any underlying spatial grid and its resolution. A large number of Bayesian and Maximum Entropy methods for 1D signal reconstruction, 2D imaging, as well as 3D tomography, appear formally similar, but one often finds individualized implementations that are neither flexible nor easily transferable. Signal inference in the framework of NIFTY can be done in an abstract way, such that algorithms, prototyped in 1D, can be applied to real world problems in higher-dimensional settings. NIFTY as a versatile library is applicable and already has been applied in 1D, 2D, 3D and spherical settings. A recent application is the D{sup 3}PO algorithm targeting the non-trivial task of denoising, deconvolving, and decomposing photon observations in high energy astronomy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Class of backpropagation techniques for limited-angle reconstruction in microwave tomography

Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction using FBPP, full 360° angular coverage is necessary. However, it has been shown that using some inherent redundancies in the projection data in a tomographic setup, accurate reconstruction is still possible with 270° coverage which is called the minimal-scan angle range. This can be done by applying weighing functions (or filters) on projection data of the object to eliminate the redundancies and accurately reconstruct the image from 270° coverage. This paper demonstrates procedures to generate many general classes of these weighing filters. These are all equivalent at 270° coverage but vary in performance at lower angular coverages and in presence of noise. This paper does a comparative analysis of different filters when angular coverage is lower than minimal-scan angle of 270°. Simulation studies have been done to find optimum weight filters for sub-minimal angular coverage (<270°)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE LACK OF DIFFUSE, NON-THERMAL HARD X-RAY EMISSION IN THE COMA CLUSTER: THE SWIFT BURST ALERT TELESCOPE'S EYE VIEW

The Coma Cluster of galaxies hosts the brightest radio halo known and has therefore been the target of numerous searches for associated inverse Compton (IC) emission, particularly at hard X-ray energies where the IC signal must eventually dominate over thermal emission. The most recent search with the Suzaku Hard X-ray Detector failed to confirm previous IC detections with RXTE and BeppoSAX, instead setting an upper limit 2.5 times below their non-thermal flux. However, this discrepancy can be resolved if the IC emission is very extended, beyond the scale of the cluster radio halo. Using reconstructed sky images from the 58-month Swift Burst Alert Telescope (BAT) all-sky survey, the feasibility of such a solution is investigated. Building on Renaud et al., we test and implement a method for extracting the fluxes of extended sources, assuming specified spatial distributions. BAT spectra are jointly fit with an XMM-Newton EPIC-pn spectrum derived from mosaic observations. We find no evidence for large-scale IC emission at the level expected from the previously detected non-thermal fluxes. For all non-thermal spatial distributions considered, which span the gamut of physically reasonable IC models, we determine upper limits for which the largest (most conservative) limit is {approx}<4.2 x 10{sup -12} erg s{sup -1} cm{sup -2} (20-80 keV), which corresponds to a lower limit on the magnetic field B > 0.2 {mu} G. A nominal flux upper limit of <2.7 x 10{sup -12} erg s{sup -1} cm{sup -2}, with corresponding B > 0.25 {mu} G, is derived for the most probable IC distribution given the size of the radio halo and likely magnetic field radial profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy morphology prediction using Capsule Networks

Abstract Understanding morphological types of galaxies is a key parameter for studying their formation and evolution. Neural networks that have been used previously for galaxy morphology classification have some disadvantages, such as not being inherently invariant under rotation. In this work, we studied the performance of Capsule Network (CapsNet), a recently introduced neural network architecture that is rotationally invariant and spatially aware, on the task of galaxy morphology classification. We designed two evaluation scenarios based on the answers from the question tree in the Galaxy Zoo project. In the first scenario, we used CapsNet for regression and predicted probabilities for all of the questions. In the second scenario, we chose the answer to the first morphology question that had the highest user agreement as the class of the object and trained a CapsNet classifier, where we also reconstructed galaxy images. We achieved promising results in both of these scenarios. Automated approaches such as the one introduced here will play a critical role in the upcoming large sky surveys.

Katebi, Reza↗

Suppression of Decoherence in Fast-Atom Diffraction at Surfaces

Scattering of fast neutral atoms with keV kinetic energies at alkali-halide surfaces under grazing angles displays intriguing diffraction patterns. The surprisingly strong persistence of quantum coherence despite the impulsive interaction with an environment at solid state density and elevated temperatures raises fundamental questions such as to the suppression of decoherence and of the quantum-to-classical crossover. We present an ab initio simulation of the quantum diffraction of fast helium beams at a LiF (100) surface in the <110> direction and compare with recent experimental diffraction data. From the quantitative reconstruction of diffraction images the vertical LiF-surface reconstruction, or buckling, can be determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Shot Diffractive Imaging with a Table-Top Femtosecond Soft X-Ray Laser-Harmonics Source

Coherent x-ray diffractive imaging is a powerful method for studies on nonperiodic structures on the nanoscale. Access to femtosecond dynamics in major physical, chemical, and biological processes requires single-shot diffraction data. Up to now, this has been limited to intense coherent pulses from a free electron laser. Here we show that laser-driven ultrashort x-ray sources offer a comparatively inexpensive alternative. We present measurements of single-shot diffraction patterns from isolated nano-objects with a single 20 fs pulse from a table-top high-harmonic x-ray laser. Images were reconstructed with a resolution of 119 nm from the single shot and 62 nm from multiple shots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Introduction to phasing

This introductory paper to the CCP4 weekend on experimental phasing introduces the concept of the ‘phase problem’ for non-experts. Modern methods of phasing are explored, including some recent examples that can be downloaded as tutorials. When collecting X-ray diffraction data from a crystal, we measure the intensities of the diffracted waves scattered from a series of planes that we can imagine slicing through the crystal in all directions. From these intensities we derive the amplitudes of the scattered waves, but in the experiment we lose the phase information; that is, how we offset these waves when we add them together to reconstruct an image of our molecule. This is generally known as the ‘phase problem’. We can only derive the phases from some knowledge of the molecular structure. In small-molecule crystallography, some basic assumptions about atomicity give rise to relationships between the amplitudes from which phase information can be extracted. In protein crystallography, these ab initio methods can only be used in the rare cases in which there are data to at least 1.2 Å resolution. For the majority of cases in protein crystallography phases are derived either by using the atomic coordinates of a structurally similar protein (molecular replacement) or by finding the positions of heavy atoms that are intrinsic to the protein or that have been added (methods such as MIR, MIRAS, SIR, SIRAS, MAD, SAD or combinations of these). The pioneering work of Perutz, Kendrew, Blow, Crick and others developed the methods of isomorphous replacement: adding electron-dense atoms to the protein without disturbing the protein structure. Nowadays, methods from small-molecule crystallography can be used to find the heavy-atom substructure and the phases for the whole protein can be bootstrapped from this prior knowledge. More recently, improved X-ray sources, detectors and software have led to the routine use of anomalous scattering to obtain phase information from either incorporated selenium or intrinsic sulfurs. In the best cases, only a single set of X-ray data (SAD) is required to provide the positions of the anomalous scatters, which together with density-modification procedures can reveal the structure of the complete protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗