Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TLD assessment of mouse dosimetry during microCT imaging

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high resolution anatomic images of small animals. Because microCT utilizes ionizing radiation for image formation, radiation exposure during imaging is a concern. The objective of this study was to quantify the radiation dose delivered during a standard microCT scan. Radiation dose was measured using thermoluminescent dosimeters (TLDs), which were irradiated employing an 80 kVp x-ray source, with 0.5 mm Al filtration and a total of 54 mA s for a full 360 deg rotation of the unit. The TLD data were validated using a 3.2 cm{sup 3} CT ion chamber probe. TLD results showed a single microCT scan air kerma of 78.0{+-}5.0 mGy when using a poly(methylmethacrylate) (PMMA) anesthesia support module and an air kerma of 92.0{+-}6.0 mGy without the use of the anesthesia module. The validation CT ion chamber study provided a measured radiation air kerma of 81.0{+-}4.0 mGy and 97.0{+-}5.0 mGy with and without the PMMA anesthesia module, respectively. Internal TLD analysis demonstrated an average mouse organ radiation absorbed dose of 76.0{+-}5.0 mGy. The author's results have defined x-ray exposure for a routine microCT study which must be taken into consideration when performing serial molecular imaging studies involving the microCT imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray film chamber with carbon target of Tien-Shan complex array

X-ray films were exposed inside the ionization calorimeter under 74g/sq cm of carbon and 5 cm of lead. The X-ray film chamber area is 35 sq. m. Moving X-ray films were used, 50% of the events, which succeeded to determine incidence time, were identified with corresponding extensive air showers (EAS). For such events the size spectrum of associated EAS was derived. Two methods of energy measurement using X-ray films and ionization calorimeter were compared. The energy transfer from selected hadron to electromagnetic component is illustrated. It is found that in cascades with high energy release into electromagnetic components the hadron component is practically absent.

Cherdyntseva, K. V.↗

The Ion Funnel: Theory, Implementations and Applications.

Invented in the 1990s, the ion funnel enabled a new approach for transporting ions through the first vacuum stage of a mass spectrometer, providing much greater transmission efficiencies than other techniques at the time. Rather than use a conical skimmer to sample a small portion of the ions entering the vacuum chamber from the inlet of an electrospray ionization interface, the ion funnel was designed to capture all of the ions in the expanding gas jet and radially focus them for efficient transfer through a conductance limiting orifice at pressures where traditional ion guiding devices failed. While initial designs required high speed pumping and exhibited a strong mass to charge ratio (m/z)-dependent ion transmission bias, subsequent advances guided by theoretical modeling have overcome those limitations to provide consistently large sensitivity gains and robust operation for a wide variety of mass spectrometers. We review the improvements in design and understanding that have brought the ion funnel to its current state of refinement. Novel applications of the ion funnel, which are continually emerging in such diverse fields as ion trapping, ion cooling, low pressure electrospray, and ion mobility spectrometry, are reviewed as well.

02 PETROLEUM↗

Containment of fluid samples in the hydrothermal diamond-anvil cell without the use of metal gaskets: Performance and advantages for in situ analysis

Metal gaskets (Re, Ir, Inconel, or stainless steel) normally used to contain fluid samples in the hydrothermal diamond-anvil cell (HDAC) are sometimes undesirable due to possible contamination and to gasket deformation at high pressures and temperatures resulting in nonisochoric behavior. Furthermore, in x-ray spectroscopic experiments, metal gaskets may attenuate the incident x-ray beam and emitted fluorescence x-rays, and the interaction of scattered radiation with the gasket may produce fluorescence that interferes with the x-ray spectrum of the sample. New arrangements and procedures were tested for the operation of the HDAC without using the metal gaskets. Distilled, de-ionized water was loaded into the sample chamber, a laser-milled recess 300 {micro}m in diameter and - 50 {micro}m deep centered in the 1.0 mm face of the lower diamond anvil, and sealed by pressing the top diamond anvil face directly against the lower one without a metal gasket in between. A maximum sample pressure of 202 MPa at 617 C was maintained for a duration of 10 min without evidence of leakage. A small change in fluid density was observed in one experiment where the sample was held at 266 MPa at 708 C for 10 min. The gasketless HDAC was also employed in x-ray absorption spectroscopy experiments, where, in addition to the sample chamber in the lower diamond, two grooves were milled at a 90{sup o} angle to each other around the sample chamber to minimize the attenuation of incident and fluorescent x rays. With a minimum distance between the sample chamber and the grooves of 80 {micro}m, a pressure of 76 MPa at 500 C was maintained for 2 h with no change in the original fluid density.

36 MATERIALS SCIENCE↗

Effective field theory analysis of the first LUX dark matter search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10 -46 cm 2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 10 4 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstructing 3D Charge Depositions in the MicroBooNE Liquid Argon Time Projection Chamber using Convolutional Neural Networks

We have developed a convolutional neural network (CNN) that reconstructs the three dimensional location of ionization produced by charge particles traversing a wire-readout liquid argon time projection chamber (LArTPC) at MicroBooNE. This method is the first CNN application to reconstruct 3D space points directly from two dimensional images of the different wire plane views. I.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200A,<2500V) through a gas column (~10cm diameter, 2m length) and ejecting the heatedgas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2eV) but needs to be stable for long test times (up to 30min) at high power (< 20MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion usingthese sensors.

Kink instability↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200 A,<2500 V) through a gas column (~6 cm diameter, 2 m length) and ejecting the heated gas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2 eV) but needs to be stable for long test times (up to 30 min) at high power (< 20 MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion using these sensors.

Kink instability↗

Towards Measuring Longitudinal Electron Diffusion in the MicroBooNE LArTPC

MicroBooNE Liquid Argon Time Projection Chamber (LArTPC) Neutrino interactions reconstructed based on ionization electrons and scintillation light Primary goals: Investigate MiniBooNE low-energy excess Neutrino-argon cross-sections LArTPC Electron Diffusion Simulation and Selection Waveform Averaging Extraction of D L Challenges and Future Work

43 PARTICLE ACCELERATORS↗

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

Detecting X-rays with an optical imaging chamber

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.↗

Identified hadron production at high transverse momenta in p+p collisions at sq sNN=200 GeV in STAR

We report the transverse momentum (p{sub T}) distributions for identified charged pions, protons and anti-protons using events triggered by high deposit energy in the Barrel Electro-Magnetic Calorimeter (BEMC) from p+p collisions at {radical}s{sub NN} = 200 GeV. The spectra are measured around mid-rapidity (|y| < 0.5) over the range of 3 < p{sub T} < 15 GeV/c with particle identification (PID) by the relativistic ionization energy loss (rdE/dx) in the Time Projection Chamber (TPC) of the Solenoidal Tracker at RHIC (STAR). The charged pion, proton and anti-proton spectra at high p{sub T} are compared with published results from minimum bias triggered events and the Next-Leading-Order perturbative quantum chromodynamic (NLO pQCD) calculations (DSS, KKP and AKK 2008). In addition, we present the particle ratios of n{sup -}/n{sup +}, {bar p}/p, p/n{sup +} and {bar p}/{pi}{sup -} in p+p collisions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The emulsion chamber technology experiment

Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

Gregory, John C.↗

Helicon thruster plasma modeling: Two-dimensional fluid-dynamics and propulsive performances

An axisymmetric macroscopic model of the magnetized plasma flow inside the helicon thruster chamber is derived, assuming that the power absorbed from the helicon antenna emission is known. Ionization, confinement, subsonic flows, and production efficiency are discussed in terms of design and operation parameters. Analytical solutions and simple scaling laws for ideal plasma conditions are obtained. The chamber model is then matched with a model of the external magnetic nozzle in order to characterize the whole plasma flow and assess thruster performances. Thermal, electric, and magnetic contributions to thrust are evaluated. The energy balance provides the power conversion between ions and electrons in chamber and nozzle, and the power distribution among beam power, ionization losses, and wall losses. Thruster efficiency is assessed, and the main causes of inefficiency are identified. The thermodynamic behavior of the collisionless electron population in the nozzle is acknowledged to be poorly known and crucial for a complete plasma expansion and good thrust efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on Sub-GeV Dark-Matter–Electron Scattering from the DarkSide-50 Experiment

Here, we present new constraints on sub-GeV dark matter particles scattering off electrons based on 6780.0 kg d of data collected with the DarkSide-50 dual-phase argon time projection chamber. This analysis uses electroluminescence signals due to ionized electrons extracted from the liquid argon target. The detector has a very high trigger probability for these signals, allowing for an analysis threshold of three extracted electrons, or approximately 0.05 keVee. We calculate the expected recoil spectra for dark matter-electron scattering in argon and, under the assumption of momentum-independent scattering, improve upon existing limits from XENON10 for dark-matter particles with masses between 30 and 100 MeV/c 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca↗