Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Electron heating during magnetic reconnection: A simulation scaling study

Electron bulk heating during magnetic reconnection with symmetric inflow conditions is examined using kinetic particle-in-cell simulations. Inflowing plasma parameters are varied over a wide range of conditions, and the increase in electron temperature is measured in the exhaust well downstream of the x-line. The degree of electron heating is well correlated with the inflowing Alfvén speed c{sub Ar} based on the reconnecting magnetic field through the relation ΔT{sub e}=0.033 m{sub i} c{sub Ar}{sup 2}, where ΔT{sub e} is the increase in electron temperature. For the range of simulations performed, the heating shows almost no correlation with inflow total temperature T{sub tot}=T{sub i}+T{sub e} or plasma β. An out-of-plane (guide) magnetic field of similar magnitude to the reconnecting field does not affect the total heating, but it does quench perpendicular heating, with almost all heating being in the parallel direction. These results are qualitatively consistent with a recent statistical survey of electron heating in the dayside magnetopause (Phan et al., Geophys. Res. Lett. 40, 4475, 2013), which also found that ΔT{sub e} was proportional to the inflowing Alfvén speed. The net electron heating varies very little with distance downstream of the x-line. The simulations show at most a very weak dependence of electron heating on the ion to electron mass ratio. In the antiparallel reconnection case, the largely parallel heating is eventually isotropized downstream due a scattering mechanism, such as stochastic particle motion or instabilities. The simulation size is large enough to be directly relevant to reconnection in the Earth's magnetosphere, and the present findings may prove to be universal in nature with applications to the solar wind, the solar corona, and other astrophysical plasmas. The study highlights key properties that must be satisfied by an electron heating mechanism: (1) preferential heating in the parallel direction; (2) heating proportional to m{sub i} c{sub Ar}{sup 2}; (3) at most a weak dependence on electron mass; and (4) an exhaust electron temperature that varies little with distance from the x-line.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid Salt Heat Exchanger Technology for VHTR Based Applications

The objective of this research is to evaluate performance of liquid salt fluids for use as a heat carrier for transferring high-temperature process heat from the very high-temperature reactor (VHTR) to chemical process plants. Currently, helium is being considered as the heat transfer fluid; however, the tube size requirements and the power associated with pumping helium may not be economical. Recent work on liquid salts has shown tremendous potential to transport high-temperature heat efficiently at low pressures over long distances. This project has two broad objectives: To investigate the compatibility of Incoloy 617 and coated and uncoated SiC ceramic composite with MgCl 2 -KCl molten salt to determine component lifetimes and aid in the design of heat exchangers and piping; and, To conduct the necessary research on the development of metallic and ceramic heat exchangers, which are needed for both the helium-to-salt side and salt-to-process side, with the goal of making these heat exchangers technologically viable. The research will consist of three separate tasks. The first task deals with material compatibility issues with liquid salt and the development of techniques for on-line measurement of corrosion products, which can be used to measure material loss in heat exchangers. Researchers will examine static corrosion of candidate materials in specific high-temperature heat transfer salt systems and develop an in situ electrochemical probe to measure metallic species concentrations dissolved in the liquid salt. The second task deals with the design of both the intermediate and process side heat exchanger systems. Researchers will optimize heat exchanger design and study issues related to corrosion, fabrication, and thermal stresses using commercial and in-house codes. The third task focuses integral testing of flowing liquid salts in a heat transfer/materials loop to determine potential issues of using the salts and to capture realistic behavior of the salts in a small scale prototype system. This includes investigations of plugging issues, heat transfer, pressure drop, and the corrosion and erosion of materials in the flowing system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploration of a Novel Technique for Waste Heat Recovery Through Molecular Dynamics: Influence of Wettability and Electric Field on Water and Water-Based Nanofluids

Most of the energy produced globally comes by way of a heat engine. The Carnot principle places a limit as to how thermodynamically efficient a heat engine can be. There is no heat engine that can be 100% thermodynamically efficient and as such a substantial proportion of all heat supplied to a heat engine is lost as waste heat. Waste heat therefore is a large energy source ready to be properly utilized. Herein, a novel approach for converting waste heat to electricity is discussed. It involves the use of the liquid to vapor phase change of a material dielectric (water) or electrolyte (nanofluid) in the embodiment of a capacitor for direct thermal to electrostatic energy conversion. While this method of waste heat recovery could potentially be added to the ever expanding portfolio of energy conversion techniques, a number of aspects must be addressed before it can be brought into practice. Water was seen as an ideal dielectric phase change material given its high relative permittivity ratio when in the liquid form as compared to its vapor form. However, given its short voltage holdoff time the phase change of water would need to occur rapidly. This brings up concerns of explosive boiling. Herein, molecular dynamics analysis into the explosive boiling behavior of thin water films gave more insight into how the interaction between the surface and liquid affected explosive boiling onset time. A Lennard-Jones potential with one interaction site and a Morse potential with three interaction sites between water and solid substrate were used. It was found generally that a stronger interaction between water film and substrate led to faster explosive boiling onset times but an increase in the number of interaction sites delayed explosive boiling, even at the same wettability (contact angle). Understanding changes in the density and enthalpy of vaporization of a liquid dielectric such as water in the presence of an electric field is of importance due to the electrostatic nature of the waste heat conversion method under consideration. Specifically, if both density and enthalpy of vaporization are increased, the thermodynamic efficiency of the waste heat conversion method under consideration is decreased. Electric field effects are explored herein via molecular dynamics using two water models, the TIP4P-Ew and SWM4-NDP. The SWM4-NDP model is polarizable while the TIP4P-Ew model is not, which allows for a determination of the importance of model polarizability (i.e. variation in water model dipole moment) on these two properties of water when subjected to an electric field. Herein it was found that both water models respond similarly in terms of density and vaporization enthalpy variance upon the introduction of an electric field. Comparison was also made to the pressure induced by the electric field (electrostriction pressure) by way of a density comparison and it was found that the predicted electrostriction pressure overestimates the pressure experienced by water. Water by itself has a high enthalpy of vaporization, which limits the efficiency of the newly proposed conversion method. Research both experimental and through simulation has shown that the vaporization enthalpy of nanofluids can be engineered via nanoparticle size and material selection. An avenue less explored is manipulating the enthalpy of vaporization by altering the interaction strength between the nanoparticles and the base fluid. In practice this could be achieved through the addition of coatings to the nanoparticles to alter their wettability to the base fluid. This was explored by using a Lennard-Jones potential and Morse potential to model the interaction between base fluid (water) and the nanoparticle. For nanoparticles 2nm in diameter and at weight percentages up to 6%, the change in vaporization enthalpy due to alterations of the interaction strength between nanoparticle and base fluid was not significant (less than a 1% difference) when compared to the effect of altering the weight percentage of nanoparticles in the nanofluid or introducing an electric field. However, the effect of wettability may still become important at other nanoparticle concentrations and sizes. In all, the studies presented here further the understanding of phase change and thermodynamic properties of water and water based nanofluids under an electrostatic field which will help inform the development of a novel approach to waste heat conversion. The reduction of waste heat will improve energy sustainability outlooks.

30 DIRECT ENERGY CONVERSION↗

Multiscale Porous High-temperature Heat Exchanger Using Ceramic Co-extrusion

In this project, our MIT, Purdue, and GE team aims to design, model, fabricate, and test a novel high temperature, compact, and durable ceramic heat exchanger to be operated under high temperature and pressure conditions for aerospace applications. Our approach is grounded in introducing multiscale porosity, i.e., centimeter-scale channels embedded with micrometer-scale channels, into the ceramic heat exchanger to significantly improve its heat transfer performance and mechanical strength while maintaining minimal pressure losses. We first developed high-fidelity thermal-fluid-mechanical model capable of precisely capturing the heat transfer rate, temperature profile, pressure drop, and mechanical stress throughout the entire heat exchanger design. Guided by our model, we identified the optimal design parameters for the SiC heat exchanger body and manifolds. Then, we established a completed fabrication procedure to create multiscale features in the ceramic heat exchanger, including co-extrusion, lamination, burnout, and sintering. We fabricated multiple heat exchanger bodies consisting of 6 × 6 and 3 × 3 centimeter-scale channels where each individual centimeter-scale channel comprises 625 crack-free microchannels with 90 μm × 90 μm opening. Owing to the multiscale features, our fabricated heat exchanger bodies exhibited desirable mechanical strength with 156 MPa flexural strength under 1300 Celsius degree. Despite the demonstrated highly tailorable microscopic features and superior mechanical strength, we identified delamination due to the complex interaction among ceramic, polymer, and gas species can be a critical challenge to create fully defect-free heat exchanger, which requires further fundamental investigations in future works. To test the heat exchanger performance, we constructed a high-temperature and high-pressure experimental apparatus that can be safely operated under 400 Celsius degree and 4 bar. With insights gained from mechanistic modeling, material development, and detailed characterization, a cost model was finally developed to understand the market potential of the developed technology, where a cost of $43,000 Celsius degree/kW was envisioned. This project developed a transformative approach to high-performance heat exchanger design. The thermal-fluid-mechanical design approach developed in this project can serve as a generic tool to guide the design of various heat-exchangers operated under high-temperature and high-pressure conditions. The material fabrication approach established in this project can be a useful guide for ceramic processing at extreme length scales.

42 ENGINEERING↗

Evaluation of Hydrogen Gettering Rates Correlated to Surface Composition and Texture of Nickel-Plated Zircaloy Getters of Different Heat Treatment Procedures

Coatings of metal specimens are known to have an impact on hydrogen gettering (hydrogen absorption). The coating can have one or more functions, such as enhancing gettering, preventing gettering and/or preventing oxidation of the metal substrate. It is known that contaminants and surface texture can impact hydrogen gettering/absorption performance, but has not previously been thoroughly explored. This study evaluated the role of different post-plating heat treatments of nickel-plated zircaloy-4 getters (NPGs) and the role of the heat treatments on gettering rates, surface composition and texture. Nickel plating is applied to prevent oxidation of the Zircaloy-4 surface and also enhances gettering. The nickel plating must be heat treated before desirable gettering can occur. Our NPG getters with historically known satisfying performance were pre-heat treated in air followed by activation heat treatment in a vacuum at a higher temperature. In this study, we were interested in finding out if both heat treatment steps were necessary to obtain a desirable gettering performance, or if one step could be omitted. XPS analysis showed that if the nickel surface is not heat treated before bonding the nickel to the zirconium in the activation step, there will be carbon contaminants on the surface, which significantly reduces gettering. We studied the texture of Zircaloy-4 using SEM/EBSD to compare NPGs with both heat treatment steps with NPGs that had no post-plating heat treatment to learn if the degree of cold work could be impacted by the heat treatment steps. We did not observe any differences in texture between them. We measured gettering rates of both pretreated and activated NPGs and NPGs that had been activated without first being pre-heat treated. We found that the NPGs without the first post-plating heating step had up to a seven times slower gettering rate and obtained higher plateau pressures due to the contaminated surface. Thus, the pre-heat treatment in air before activation is necessary to avoid slower gettering rates and higher plateau pressures.

36 MATERIALS SCIENCE↗

Heat pipe applications in aircraft propulsion

Heat pipes for improving the cycle efficiency and/or thrust-to-weight ratio of aircraft gas turbines are examined. A heat pipe employs a capillary structure, a wick, and an evacuated chamber to transfer heat between condensor and evaporator ends. Heat absorbed at the evaporator is transported to the condensor. In an aircraft, the heat pipe can be stationary or rotating, can be used for cooling stators and rotors, and is amenable to shapes such as cylinders, cones, and flat plates. Heat pipes in aircraft gas turbines can be applied for intercooling between stages, regeneration, reheat, and blade cooling. Improvements are projected in the cycle efficiency, thrust and thrust specific fuel consumption in the fanjet by using heat pipes. Consideration is also given to heat pipe heat exchangers with high axial heat transfer for stationary heat pipes and high heat transport for rotating heat pipes.

Beltran, M. R.↗

Pressurized bellows flat contact heat exchanger interface

Disclosed is an interdigitated plate-type heat exchanger interface. The interface includes a modular interconnect to thermally connect a pair or pairs of plate-type heat exchangers to a second single or multiple plate-type heat exchanger. The modular interconnect comprises a series of parallel, plate-type heat exchangers arranged in pairs to form a slot therebetween. The plate-type heat exchangers of the second heat exchanger insert into the slots of the modular interconnect. Bellows are provided between the pairs of fins of the modular interconnect so that when the bellows are pressurized, they drive the plate-type heat exchangers of the modular interconnect toward one another, thus closing upon the second heat exchanger plates. Each end of the bellows has a part thereof a thin, membrane diaphragm which readily conforms to the contours of the heat exchanger plates of the modular interconnect when the bellows is pressurized. This ensures an even distribution of pressure on the heat exchangers of the modular interconnect thus creating substantially planar contact between the two heat exchangers. The effect of the interface of the present invention is to provide a dry connection between two heat exchangers whereby the rate of heat transfer can be varied by varying the pressure within the bellows.

Voss, Fred E.↗

Cargo systems manual: Heat Pipe Performance (HPP) STS-66

The purpose of the cargo systems manual (CSM) is to provide a payload reference document for payload and shuttle flight operations personnel during shuttle mission planning, training, and flight operations. It includes orbiter-to-payload interface information and payload system information (including operationally pertinent payload safety data) that is directly applicable to the Mission Operations Directorate (MOD) role in the payload mission. The primary objectives of the heat pipe performance (HPP) are to obtain quantitative data on the thermal performance of heat pipes in a microgravity environment. This information will increase understanding of the behavior of heat pipes in space and be useful for application to design improvements in heat pipes and associated systems. The purpose of HPP-2 is to establish a complete one-g and zero-g data base for axial groove heat pipes. This data will be used to update and correlate data generated from a heat pipe design computer program called Grooved Analysis Program (GAP). The HPP-2 objectives are to: determine heat transport capacity and conductance for open/closed grooved heat pipes and different Freon volumes (nominal, under, and overcharged) using a uniform heat load; determine heat transport capacity and conductance for single/multiple evaporators using asymmetric heat loads; obtain precise static, spin, and rewicking data points for undercharged pipes; investigate heat flux limits (asymmetric heat loads); and determine effects of positive body force on thermal performance.

Napp, Robert↗

Heat transfer measurements for Stirling machine cylinders

The primary purpose of this study was to measure the effects of inflow-produced heat turbulence on heat transfer in Stirling machine cylinders. A secondary purpose was to provide new experimental information on heat transfer in gas springs without inflow. The apparatus for the experiment consisted of a varying-volume piston-cylinder space connected to a fixed volume space by an orifice. The orifice size could be varied to adjust the level of inflow-produced turbulence, or the orifice plate could be removed completely so as to merge the two spaces into a single gas spring space. Speed, cycle mean pressure, overall volume ratio, and varying volume space clearance ratio could also be adjusted. Volume, pressure in both spaces, and local heat flux at two locations were measured. The pressure and volume measurements were used to calculate area averaged heat flux, heat transfer hysteresis loss, and other heat transfer-related effects. Experiments in the one space arrangement extended the range of previous gas spring tests to lower volume ratio and higher nondimensional speed. The tests corroborated previous results and showed that analytic models for heat transfer and loss based on volume ratio approaching 1 were valid for volume ratios ranging from 1 to 2, a range covering most gas springs in Stirling machines. Data from experiments in the two space arrangement were first analyzed based on lumping the two spaces together and examining total loss and averaged heat transfer as a function of overall nondimensional parameter. Heat transfer and loss were found to be significantly increased by inflow-produced turbulence. These increases could be modeled by appropriate adjustment of empirical coefficients in an existing semi-analytic model. An attempt was made to use an inverse, parameter optimization procedure to find the heat transfer in each of the two spaces. This procedure was successful in retrieving this information from simulated pressure-volume data with artificially generated noise, but it failed with the actual experimental data. This is evidence that the models used in the parameter optimization procedure (and to generate the simulated data) were not correct. Data from the surface heat flux sensors indicated that the primary shortcoming of these models was that they assumed turbulence levels to be constant over the cycle. Sensor data in the varying volume space showed a large increase in heat flux, probably due to turbulence, during the expansion stroke.

Kornhauser, Alan A.↗

Maximal Oxygen Uptake, Sweating and Tolerance to Exercise in the Heat

The physiological mechanisms that facilitate acute acclimation to heat have not been fully elucidated, but the result is the establishment of a more efficient cardiovascular system to increase heat dissipation via increased sweating that allows the acclimated man to function with a cooler internal environment and to extend his performance. Men in good physical condition with high maximal oxygen uptakes generally acclimate to heat more rapidly and retain it longer than men in poorer condition. Also, upon first exposure trained men tolerate exercise in the heat better than untrained men. Both resting in heat and physical training in a cool environment confer only partial acclimation when first exposed to work in the heat. These observations suggest separate additive stimuli of metabolic heat from exercise and environmental heat to increase sweating during the acclimation process. However, the necessity of utilizing physical exercise during acclimation has been questioned. Bradbury et al. (1964) have concluded exercise has no effect on the course of heat acclimation since increased sweating can be induced by merely heating resting subjects. Preliminary evidence suggests there is a direct relationship between the maximal oxygen uptake and the capacity to maintain thermal regulation, particularly through the control of sweating. Since increased sweating is an important mechanism for the development of heat acclimation, and fit men have high sweat rates, it follows that upon initial exposure to exercise in the heat, men with high maximal oxygen uptakes should exhibit less strain than men with lower maximal oxygen uptakes. The purpose of this study was: (1) to determine if men with higher maximal oxygen uptakes exhibit greater tolerance than men with lower oxygen uptakes during early exposure to exercise in the heat, and (2) to investigate further the mechanism of the relationship between sweating and maximal work capacity.

Greenleaf, J. E.↗

Vertical Profiles of Latent Heat Release and Their Retrieval for TOGA COARE Convective Systems Using a Cloud Resolving Model, SSM/I, and Ship-borne Radar Data

Latent heating profiles associated with three (TOGA COARE) Tropical Ocean and Global Atmosphere Coupled Ocean Atmosphere Response Experiment active convective episodes (December 10-17 1992; December 19-27 1992; and February 9-13 1993) are examined using the Goddard Cumulus Ensemble (GCE) Model and retrieved by using the Goddard Convective and Stratiform Heating (CSH) algorithm . The following sources of rainfall information are input into the CSH algorithm: Special Sensor Microwave Imager (SSM/1), Radar and the GCE model. Diagnostically determined latent heating profiles calculated using 6 hourly soundings are used for validation. The GCE model simulated rainfall and latent heating profiles are in excellent agreement with those estimated by soundings. In addition, the typical convective and stratiform heating structures (or shapes) are well captured by the GCE model. Radar measured rainfall is smaller than that both estimated by the GCE model and SSM/I in all three different COARE IFA periods. SSM/I derived rainfall is more than the GCE model simulated for the December 19-27 and February 9-13 periods, but is in excellent agreement with the GCE model for the December 10-17 period. The GCE model estimated stratiform amount is about 50% for December 19-27, 42% for December 11-17 and 56% for the February 9-13 case. These results are consistent with large-scale analyses. The accurate estimates of stratiform amount is needed for good latent heating retrieval. A higher (lower) percentage of stratiform rain can imply a maximum heating rate at a higher (lower) altitude. The GCE model always simulates more stratiform rain (10 to 20%) than the radar for all three convective episodes. SSM/I derived stratiform amount is about 37% for December 19-27, 48% for December 11-17 and 41% for the February 9-13 case. Temporal variability of CSH algorithm retrieved latent heating profiles using either GCE model simulated or radar estimated rainfall and stratiform amount is in good agreement with that diagnostically determined for all three periods. However, less rainfall and a smaller stratiform percentage estimated by radar resulted in a weaker (underestimated) latent heating profile and a lower maximum latent heating level compared to those determined diagnostically. Rainfall information from SSM/I can not retrieve individual convective events due to poor temporal sampling. Nevertheless, this study suggests that a good 4r, rainfall retrieval from SSM/I for a convective event always leads to a good latent heating retrieval. Sensitivity testing has been performed and the results indicate that the SSM/I derived time averaged stratiform amount may be underestimated for December 19-27. Time averaged heating profiles derived from SSM/I, however, are not in bad agreement with those derived by soundings for the December 10-17 convective period. The heating retrievals may be more accurate for longer time scales provided there is no bias in the sampling.

Tao, Wei-Kuo↗

An Assessment of Magnetic Conditions for Strong Coronal Heating in Solar Active Regions by Comparing Observed Loops with Computed Potential Field Lines

We report further results on the magnetic origins of coronal heating found from registering coronal images with photospheric vector magnetograms. For two complementary active regions, we use computed potential field lines to examine the global non-potentiality of bright extended coronal loops and the three-dimensional structure of the magnetic field at their feet, and assess the role of these magnetic conditions in the strong coronal heating in these loops. The two active regions are complementary, in that one is globally potential and the other is globally nonpotential, while each is predominantly bipolar, and each has an island of included polarity in its trailing polarity domain. We find the following: (1) The brightest main-arch loops of the globally potential active region are brighter than the brightest main- arch loops of the globally strongly nonpotential active region. (2) In each active region, only a few of the mainarch magnetic loops are strongly heated, and these are all rooted near the island. (3) The end of each main-arch bright loop apparently bifurcates above the island, so that it embraces the island and the magnetic null above the island. (4) At any one time, there are other main-arch magnetic loops that embrace the island in the same manner as do the bright loops but that are not selected for strong coronal heating. (5) There is continual microflaring in sheared core fields around the island, but the main-arch bright loops show little response to these microflares. From these observational and modeling results we draw the following conclusions: (1) The heating of the main-arch bright loops arises mainly from conditions at the island end of these loops and not from their global non-potentiality. (2) There is, at most, only a loose coupling between the coronal heating in the bright loops of the main arch and the coronal heating in the sheared core fields at their feet, although in both the heating is driven by conditions/events in and around the island. (3) The main-arch bright loops are likely to be heated via reconnection driven at the magnetic null over the island. The details of how and where (along the null line) the reconnection is driven determine which of the split-end loops are selected for strong heating. (4) The null does not appear to be directly involved in the heating of the sheared core fields or in the heating of an extended loop rooted in the island. Rather, these all appear to be heated by microflares in the sheared core field.

Gary, G. A.↗

Towards Understanding the Fluid Dynamic Phenomenon of Interest to Rocket Base Heating: A Review

The significance of the base heating problem for rockets during ascent is due to the complex interaction between the rocket nozzle plumes and the external-flow which can change the flow characteristics in the base region dramatically. At lower altitudes the external-flow merges with the plume-flow, without the formation of a large separated flow region, and the cooler external-flow promotes convective cooling of the base wall. Under these conditions the majority of the base heating is due to radiative heating from the shock heated plume gases. At higher altitudes, however, the process of base heating is not so straightforward. The plume and the base flow expands dramatically and separated flow regions occur in the base area. Hot exhaust gases from the rocket nozzle will be entrained into the separated flow regions and produce a convective component to the base wall heating. Further, if the rocket exhaust-gas contains soot, the soot can increase the emission from the gas and dramatically increase the wall absorption coefficient for radiative heating if it is deposited on the walls . In addition, if the rocket exhaust gas is fuel rich, the fuel can bum in the separated flow regions and further increase the base heating. The base burning phenomenon, and the increased base heating caused by it at higher altitudes, have been observed for the Space Shuttle and Saturn Rocket. Under these conditions, the total heating is significantly higher than the heating without separated flow in the base region, and the increase in heating is directly attributable to the fluid dynamic complexity of the base region. Realistic simulation of the base heating requires that the calculated flow environment reproduce the fluid dynamic flow features accurately. Thus, it will be necessary to introduce into the CFD codes the capability for the flow to respond to the complex vehicle geometry, the effect of turbulence, the ability to accurately reproduce the plume shock/shear layer structures and capture such phenomenon as shock induced base separation and base-burning phenomenon. A survey of experimental, theoretical and computational work that details the fluid dynamics of the base flow environment will be presented in the proposed paper. CFD simulations of rocket base flows using standard CFD codes such as OVERFLOW or GASP will be explored to capture these phenomenon accurately. Merits and limitations of these codes for base flow environment predictions will be explored.

Venkatapathy, E.↗

Evaluation and Application of Satellite-Based Latent Heating Profile Estimation Methods

In recent years, methods for estimating atmospheric latent heating vertical structure from both passive and active microwave remote sensing have matured to the point where quantitative evaluation of these methods is the next logical step. Two approaches for heating algorithm evaluation are proposed: First, application of heating algorithms to synthetic data, based upon cloud-resolving model simulations, can be used to test the internal consistency of heating estimates in the absence of systematic errors in physical assumptions. Second, comparisons of satellite-retrieved vertical heating structures to independent ground-based estimates, such as rawinsonde-derived analyses of heating, provide an additional test. The two approaches are complementary, since systematic errors in heating indicated by the second approach may be confirmed by the first. A passive microwave and combined passive/active microwave heating retrieval algorithm are evaluated using the described approaches. In general, the passive microwave algorithm heating profile estimates are subject to biases due to the limited vertical heating structure information contained in the passive microwave observations. These biases may be partly overcome by including more environment-specific a priori information into the algorithm s database of candidate solution profiles. The combined passive/active microwave algorithm utilizes the much higher-resolution vertical structure information provided by spaceborne radar data to produce less biased estimates; however, the global spatio-temporal sampling by spaceborne radar is limited. In the present study, the passive/active microwave algorithm is used to construct a more physically-consistent and environment-specific set of candidate solution profiles for the passive microwave algorithm and to help evaluate errors in the passive algorithm s heating estimates. Although satellite estimates of latent heating are based upon instantaneous, footprint- scale data, suppression of random errors requires averaging to at least half-degree resolution. Analysis of mesoscale and larger space-time scale phenomena based upon passive and passive/active microwave heating estimates from TRMM, SSMI, and AMSR data will be presented at the conference.

Olson, William S.↗

Utilizing Radioisotope Power System Waste Heat for Spacecraft Thermal Management

An advantage of using a Radioisotope Power System (RPS) for deep space or planetary surface missions is the readily available waste heat, which can be used for a number of beneficial purposes including: maintaining electronic components within a controlled temperature range, warming propulsion tanks and mobility actuators, and maintaining liquid propellants above their freezing temperature. Previous missions using Radioisotope Thermoelectric Generators (RTGs) dissipated large quantities of waste heat due to the low efficiency of the thermoelectric conversion technology. The next generation RPSs, such as the 110-Watt Stirling Radioisotope Generator (SRG110) will have higher conversion efficiencies, thereby rejecting less waste heat at a lower temperature and may require alternate approaches to transferring waste heat to the spacecraft. RTGs, with efficiencies of ~6 to 7 percent, reject their waste heat at the relatively high heat rejection temperature of 200 C. This is an advantage when rejecting heat to space; however, transferring heat to the internal spacecraft components requires a large and heavy radiator heat exchanger. At the same time, sensitive spacecraft instruments must be shielded from the thermal radiation of the RTG. The SRG110, with an efficiency around 22 percent and 50 C nominal housing surface temperature, can readily transfer the available waste heat directly via heat pipes, thermal straps, or fluid loops. The lower temperatures associated with the SRG110 avoid the chances of overheating other scientific components, eliminating the need for thermal shields. This provides the spacecraft designers more flexibility when locating the generator for a specific mission. A common misconception with high-efficiency systems is that there is not enough waste heat for spacecraft thermal management. This paper will dispel this misconception and investigate the use of a high-efficiency SRG110 for spacecraft thermal management and outline potential methods of waste heat utilization in several conceptual missions (Lunar Rover, Mars Rover, and Titan Lander). The advantages associated with the SRG110 as they relate to ease of assembly, less complex interfaces, and overall mass savings for a spacecraft will be highlighted.

Pantano, David R.↗