Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOSPITAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Light Microsopy Module, International Space Station Premier Automated Microscope

The Light Microscopy Module (LMM) was launched to the International Space Station (ISS) in 2009 and began science operations in 2010. It continues to support Physical and Biological scientific research on ISS. During 2015, if all goes as planned, five experiments will be completed: [1] Advanced Colloids Experiments with a manual sample base -3 (ACE-M-3), [2] the Advanced Colloids Experiment with a Heated Base -1 (ACE-H-1), [3] (ACE-H-2), [4] the Advanced Plant Experiment -03 (APEX-03), and [5] the Microchannel Diffusion Experiment (MDE). Preliminary results, along with an overview of present and future LMM capabilities will be presented; this includes details on the planned data imaging processing and storage system, along with the confocal upgrade to the core microscope. [1] New York University: Paul Chaikin, Andrew Hollingsworth, and Stefano Sacanna, [2] University of Pennsylvania: Arjun Yodh and Matthew Gratale, [3] a consortium of universities from the State of Kentucky working through the Experimental Program to Stimulate Competitive Research (EPSCoR): Stuart Williams, Gerold Willing, Hemali Rathnayake, et al., [4] from the University of Florida and CASIS: Anna-Lisa Paul and Rob Ferl, and [5] from the Methodist Hospital Research Institute from CASIS: Alessandro Grattoni and Giancarlo Canavese.

Microscopy↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

Chan, Eugene↗

Climate Science for Decision-Making in the New York Metropolitan Region

New York City is one of the world's most vulnerable cities to coastal flooding, due to a high concentration of population and assets near a coastline exposed to warm-season tropical storms and cold -season Nor'easter storms. Among U.S. cities, New York City is second only to New Orleans in population living less than 4 ft above the local high tide. By the 2050s, average annual losses due to coastal flooding alone could exceed $2 billion for the combined New York City-Newark region. Perhaps the most iconic example of a vulnerable New York City asset is the financial district located at the southern tip of Manhattan, however low-lying coastal assets include the full complement of major highways, subways and tunnels, hospitals, schools, wastewater treatment plants, food distribution centers, and people's homes. Given the magnitude of the assets at risk, a compelling case can be made that long-term adaptation makes economic sense for New York City. Given New York's access to economic, human, and technological resources for resilience measures, the City may be able to achieve this resilience. The city's political environment-New York City is a place where climate science is generally not a partisan issue-and the city's experience with uncertainty and overall risk framing (e.g., financing of bond issues for multi-billion dollar infrastructure with multidecade expected lifetimes), encourage climate risk framing.

Horton, Radley↗

Urban Heat Wave Hazard Assessment

Heat waves are the largest cause of environment-related deaths globally. On average, over 6,000 people in the United States alone are hospitalized each summer due to excessive heat. Key elements leading to these disasters are elevated humidity and the urban heat island effect, which act together to increase apparent temperature and amplify the effects of a heat wave. Urban demographics and socioeconomic factors also play a role in determining individual risk. Currently, advisories of impending heat waves are often too generalized, with limited or no spatial variability over urban regions. This frequently contributes to a lack of specific response on behalf of the population. A goal of this project is to develop a product that has the potential to provide more specific heat wave guidance invoking greater awareness and action.

Urban↗

Nanochanneled Device and Related Methods

A nanochannel delivery device and method of manufacturing and use. The nanochannel delivery device comprises an inlet, an outlet, and a nanochannel. The nanochannel may be oriented parallel to the primary plane of the nanochannel delivery device. The inlet and outlet may be in direct fluid communication with the nanochannel. Considerable advances have been made in the field oftherapeutic agent (e.g. drug) delivery technology over thelast three decades, resulting in many breakthroughs in clinicalmedicine. The creation of therapeutic agent deliverydevices that are capable of delivering therapeutic agents incontrolled ways is still a challenge. One of the majorrequirements for an implantable drug delivery device iscontrolled release of therapeutic agents, ranging from smalldrug molecules to larger biological molecules. It is particularlydesirable to achieve a continuous passive drug releaseprofile consistent with zero order kinetics whereby theconcentration of drug in the bloodstream remains constantthroughout an extended delivery period.These devices have the potential to improve therapeuticefficacy, diminish potentially life-threatening side effects,improve patient compliance, minimize the intervention ofhealthcare personnel, reduce the duration of hospital stays,and decrease the diversion of regulated drugs to abusiveuses.Nanochannel delivery devices may be used in drug deliveryproducts for the effective administration of drugs. Inaddition, nanochannel delivery devices can be used in otherapplications where controlled release of a substance overtime is needed. Embodiments of this invention comprise a nanochanneldelivery device having nanochannels within a structureconfigured to yield high mechanical strength and high flowrates. Various fabrication protocols may be used to form thenanochannel delivery device. Embodiments of the fabricateddevices feature horizontal nanochannel lay-out (e.g., thenanochannel is parallel to the primary plane of the device),high molecule transport rate, high mechanical strength,optional multilayered lay-out, amenability to select channellining materials, and possible transparent top cover. Basedon silicon microfabrication technology, the dimensions ofthe nanochannel area as well as concomitant microchannelareas can be precisely controlled, thus providing a predictable,reliable, constant release rate of drug (or other) moleculesover an extended time period. In certain embodiments,the nanochannel delivery device can be used to builda multilayered nanochannel structure.

Ferrari, Mauro↗

Coastal California's Fog as a Unique Habitable Niche: Design for Autonomous Sampling and Preliminary Aerobiological Characterization

Just as on the land or in the ocean, atmospheric regions may be more or less hospitable to life. The aerobiosphere, or collection of living things in Earth's atmosphere, is poorly understood due to the small number and ad hoc nature of samples studied. However, we know viable airborne microbes play important roles, such as providing cloud condensation nuclei. Knowing the distribution of such microorganisms and how their activity can alter water, carbon, and other geochemical cycles is key to developing criteria for planetary habitability, particularly for potential habitats with wet atmospheres but little stable surface water. Coastal California has regular, dense fog known to play a major transport role in the local ecosystem. In addition to the significant local (1 km) geographical variation in typical fog, previous studies have found that changes in height above surface of as little as a few meters can yield significant differences in typical concentrations, populations and residence times. No single current sampling platform (ground-based impactors, towers, balloons, aircraft) is capable of accessing all of these regions of interest.A novel passive fog and cloud water sampler, consisting of a lightweight passive impactor suspended from autonomous aerial vehicles (UAVs), is being developed to allow 4D point sampling within a single fog bank, allowing closer study of small-scale (100 m) system dynamics. Fog and cloud droplet water samples from low-altitude aircraft flights in nearby coastal waters were collected and assayed to estimate the required sample volumes, flight times, and sensitivity thresholds of the system under design.125 cloud water samples were collected from 16 flights of the Center for Interdisciplinary Remotely Piloted Aircraft Studies (CIRPAS) instrumented Twin Otter, equipped with a sampling tube collector, occurring between 18 July and 12 August 2016 below 1 km altitude off the central coast. The collector was flushed first with 70 ethanol, then with sterile DI water, between sampling regions. Collected volumes ranged from 100 L to 12 mL. All samples were diluted serially and plated on two different types of agar, nutrient-dense (PCA) and sparse (R-2A). Plates were incubated at room temperature and counted when colonies first appeared and again at 2 weeks.Preliminary results from seven flights are consistent with generally reported colony-forming unit (CFU) values for terrestrial fog water (e.g., [4]). The PCA assay ranged from 400 to 125,000 CFU/mL, R-2A from 700 to 130,000 CFU/mL. PCA and R-2A counts were not significantly different from each other at I^ plus or minus +/- 0.05, although observationally, the R2A plates had more pigmented colonies. CFU counts from the majority of flights were not different from each other in mean at the same level of significance, but about half differed in median, indicating differences in underlying distribution. These results validate the presence of viable microorganisms in coastal California fog at levels that should be easily detectable by our sampling system. The indicated distribution differences underscore the need for small-scale, long-term sampling surveys. Future planned work includes ion chromatography for limiting nutrients, ATP quantification, and qPCR for several microbial classes of interest.

Coastal↗

Single-Event Effect Testing of the Vishay Si7414DN n-Type TrenchFET(Registered Trademark) Power MOSFET

This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.

proton testing↗

Proton Testing of nVidia Jetson TX1

Single-Event Effects (SEE) testing was conducted on the nVidia Jetson TX1 System on Chip (SOC); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospitals (MGH) Francis H. Burr Proton Therapy Center on October 16th, 2016 using 200MeV protons. This testing trip was purposed to provide a baseline assessment of the radiation susceptibility of the DUT as no previous testing had been conducted on this component.

Proton testing↗

Proton Testing of nVidia GTX 1050 GPU

Single-Event Effects (SEE) testing was conducted on the nVidia GTX 1050 Graphics Processor Unit (GPU); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospitals (MGH) Francis H. Burr Proton Therapy Center on April 9th, 2017 using 200-MeV protons. This testing trip was purposed to provide a baseline assessment of the radiation susceptibility of the DUT as no previous testing had been conducted on this component.

Proton testing↗

Proton Testing of nVidia GTX 1050 GPU, Part 2

Single-Event Effects (SEE) testing was conducted on the nVidia GTX 1050 Graphics Processor Unit (GPU); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on April 28th, 2018 using 200-MeV protons. This testing trip was purposed to provide additional radiation susceptibility data from payloads compiled in Q3FY18. While not all radiation-induced errors are critical, the effects on the application need to be considered. More so, failure of the device and an inability to reset itself should be considered detrimental to the application. Radiation effects on electronic components are a significant reliability issue for systems intended for space.

Single-Event Effects (SEE)↗

Automated Cardiovascular Pathology Assessment using Semantic Segmentation and Ensemble Learning

Cardiac magnetic resonance imaging provides high spatial resolution, enabling improved extraction of important functional and morphological features for cardiovascular disease staging. Segmentation of ventricular cavities and myocardium in cardiac cine sequencing provides a basis to quantify cardiac measures such as ejection fraction. A method is presented that curtails the expense and observer bias of manual cardiac evaluation by combining semantic segmentation and disease classification into a fully automatic processing pipeline. The initial processing element consists of a robust dilated convolutional neural network architecture for voxel-wise segmentation of the myocardium and ventricular cavities. The resulting comprehensive volumetric feature matrix captures diagnostic clinical procedure data and is utilized by the final processing element to model a cardiac pathology classifier. Our approach evaluated anonymized cardiac images from a training data set of 100 patients (4 pathology groups, 1 healthy group, 20 patients per group) examined at the University Hospital of Dijon. The top average Dice index scores achieved were 0.940, 0.886, 0.849 for structure segmentation of the left ventricle (LV), myocardium and right ventricle (RV) respectively. A 5-ary pathology classification accuracy of 90% was recorded on an independent test set using the trained model. Performance results demonstrate potential for advanced machine learning methods to deliver accurate, efficient and reproducible cardiac pathological assessment.

Semantic Segmentation↗

Proton Testing of AMD Ryzen 3 1200 Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 1200 microprocessor. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

single event functional interrupt (SEFI)↗

Proton Testing of AMD Ryzen 3 2200G Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 2200G microprocessor with integrated graphics. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

radiation tesing↗

Proton Testing of AMD e9173 GPU

Single-Event Effects (SEE) testing was conducted on the AMD e9173 Graphics Processor Unit (GPU). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center.

Single-Event Effects (SEE)↗

Proton Testing of nVidia Jetson TX2

Single-Event Effects (SEE) testing was conducted on the nVidia Jetson TX2 System on Chip (SOC). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

System on Chip (SOC)↗

Automated Semantic Segmentation for Volumetric Cardiovascular Feature Quantification and Pathology Assessment

We present a pipeline method that curtails the expense and observer bias of manual cardiac evaluation by combining semantic segmentation and disease classification as a fully automatic processing pipeline. The initial element consists of a 2D U-Net convolutional neural network architecture for voxel-wise segmentation of the myocardium and ventricular cavities. The results of the segmentation were used to compute a comprehensive volumetric feature matrix that captured diagnostic clinical procedure data and that was used to model a cardiac pathology classifier.Our approach evaluated anonymized parasternal MRI cardiac images from a database of 100 patients (4 pathology groups, 1 healthy group, 20 patients per group) examined at the University Hospital of Dijon. We achieved top average Dice index scores of 0.939, 0.849, 0.886 for structure segmentation of the left ventricle (LV), right ventricle (RV) and myocardium respectively. A 5-ary pathology classification accuracy of 90% was recorded on an independent test set using our trained model.

Lindsey, Tony↗

Nasa GeneLab Computomics Reveal Horizontal Gene Transfer on International Space Station Environmental Metagenomes

Prokaryotic lifeforms can be observed to demonstrate many keen adaptive advantages, perhaps facilitated by a nature simplistic relative to divergent domains of life. In particular, decompartmentalized gene expression facilitates adaptation by allowing free exchange of genetic material, albeit at the cost of increased susceptibility to genetic damage. Thus, these lifeforms must compensate by embracing diverse investment strategies in an attempt to “brute force” the evolvability equation through precipitous genesis, lean metabolic efficiency, and sheer population. This prokaryotic archetype also enables symbiotic relationships with secondary mobile genetic elements known as plasmids, which have been shown to drive evolution on rapid temporal scales through processes such as conjugation and transformation. This study attempts to decipher whether these mechanisms of horizontal gene transfer (HGT) are major factors in determining prokaryote fitness within a unique isolated environment, the International Space Station (ISS). The ISS Microbial Tracking (MT) project has generated a wealth of data concerning the successive reigns of microbial genera that appear to thrive amidst harsh conditions for life. Despite relatively higher doses of ionizing radiation as compared to Earth, complications associated with microgravity, and the anti-microbial mélange deployed, microbial life still persists in this environment. The NASA GeneLab serves as a data repository and analysis platform to enable researchers to access space flight factor related data. With the use of GeneLab’s modern computational suites (computomics), phylogenetic and functional genomic investigations of HGT events were conducted on the data generated from the MT-1 project. The putative data concerning the plasmid population (plasmidome) of the ISS was algorithmically derived and compared to those of habitats with similar environmental dynamics- such as living quarters and hospitals- to investigate whether these HGT elements may play crucial role(s) in shaping the microbiome of this closed habitat that serves as the only inhabited structure in space.

Bense, Nicholas↗