VERTICAL MIGRATION OF RADIONUCLIDES IN THE VICINITY OF THE CHERNOBYL CONFINEMENT SHELTER

Studies on vertical migration of Chernobyl-origin radionuclides in the 5-km zone of the Chernobyl Nuclear Power Plant (ChNPP) in the area of the Red Forest experimental site were completed. Measurements were made by gamma spectrometric methods using high purity germanium (HPGe) detectors with beryllium windows. Alpha-emitting isotopes of plutonium were determined by the measurement of the x-rays from their uranium progeny. The presence of {sup 60}Co, {sup 134,137}Cs, {sup 154,155}Eu, and {sup 241}Am in all soil layers down to a depth of 30 cm was observed. The presence of {sup 137}Cs and {sup 241}Am were noted in the area containing automorphous soils to a depth of 60 cm. In addition, the upper soil layers at the test site were found to contain {sup 243}Am and {sup 243}Cm. Over the past ten years, the {sup 241}Am/{sup 137}Cs ratio in soil at the experimental site has increased by a factor of 3.4, nearly twice as much as would be predicted based solely on radioactive decay. This may be due to 'fresh' fallout emanating from the ChNPP Confinement Shelter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High resolution simulations of ignition capsule designs for the National Ignition Facility

Ignition capsule designs for the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 443, 2841 (2004)] have continued to evolve in light of improved physical data inputs, improving simulation techniques, and - most recently - experimental data from a growing number of NIF sub-ignition experiments. This paper summarizes a number of recent changes to the cryogenic capsule design and some of our latest techniques in simulating its performance. Specifically, recent experimental results indicated harder x-ray drive spectra in NIF hohlraums than were predicted and used in previous capsule optimization studies. To accommodate this harder drive spectrum, a series of high-resolution 2-D simulations, resolving Legendre mode numbers as high as two thousand, were run and the germanium dopant concentration and ablator shell thicknesses re-optimized accordingly. Simultaneously, the possibility of cooperative or nonlinear interaction between neighboring ablator surface defects has motivated a series of fully 3-D simulations run with the massively parallel HYDRA code. These last simulations include perturbations seeded on all capsule interfaces and can use actual measured shell surfaces as initial conditions. 3-D simulations resolving Legendre modes up to two hundred on large capsule sectors have run through ignition and burn, and higher resolution simulations resolving as high as mode twelve hundred have been run to benchmark high-resolution 2-D runs. Finally, highly resolved 3-D simulations have also been run of the jet-type perturbation caused by the fill tube fitted to the capsule. These 3-D simulations compare well with the more typical 2-D simulations used in assessing the fill tube's impact on ignition. Coupled with the latest experimental inputs from NIF, our improving simulation capability yields a fuller and more accurate picture of NIF ignition capsule performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermoelectric characterization of suspended single silicon%3CU%2B2010%3Egermanium alloy nanowires.

The use of nanowires for thermoelectric energy generation has gained momentum in recent years as an approach to improve the figure of merit (ZT) due in part to larger phonon scattering at the boundary resulting in reduced thermal conductivity while electrical conductivity is not significantly affected. Silicon-germanium (SiGe) alloy nanowires are promising candidates to further reduce thermal conductivity by phonon scattering because bulk SiGe alloys already have thermal conductivity comparable to reported Si nanowires. In this work, we show that thermal and electrical conductivity can be measured for the same single nanowire eliminating the uncertainties in ZT estimation due to measuring the thermal conduction on one set of wires and the electrical conduction on another set. In order to do so, we use nanomanipulation to place vapor-liquid-solid boron-doped SiGe alloy nanowires on predefined surface structures. Furthermore, we developed a contact-annealing technique to achieve negligible electrical contact resistance for the placed nanowires that allows us, for the first time, to measure electrical and thermal properties on the same device. We observe that thermal conductivity for SiGe nanowires is dominated by alloy scattering for nanowires down to 100 nm in diameter between the temperature range 40-300 K. The estimated electronic contribution of the thermal conductivity as given by the Wiedemann-Franz relationship is about 1 order of magnitude smaller than the measured thermal conductivity which indicates that phonons carry a large portion of the heat even at such small dimensions.

36 MATERIALS SCIENCE↗

GFOC Project results: High Temperature / High Pressure, Hydrogen Tolerant Optical Fiber

Tests results are given for exposure of multimode optical fiber to high temperatures (300 deg. C) and high partial pressure (15 bar) hydrogen. These results demonstrate that fluorine down doped optical fibers are much more hydrogen tolerant than traditional germanium doped multimode optical fibers. Also demonstrated is the similar hydrogen tolerance of carbon coated and non-carbon coated fibers. Model for reversible H2 impact in fiber versus T{sup o}C and H2 pressure is given. These results have significant impact for the longevity of use for distributed temperature sensing applications in harsh environments such as geothermal wells.

08 HYDROGEN↗

Evaluation of ANGLE(R), a code for calculating HPGe detector efficiencies

This paper evaluates the ANGLE(reg sign) software package, an advanced efficiency calibration software for high purity germanium detectors that is distributed by ORTEC(reg sign). ANGLE(reg sign) uses a semi-empirical approach, by way of the efficiency transfer method, based on the calculated effective solid angle. This approach would have an advantage over the traditional relative and stochastic methods by decreasing the chances for systematic errors and reducing sensitivity to uncertainties in detector parameters. For experimental confirmation, a closed-end coaxial HPGe detector was used with sample geometries frequently encountered at the Los Alamos National Laboratory. The results obtained were sufficient for detector-source configurations which included intercepting layers of plexiglass and carbon graphite, but somewhat insufficient for bare source configurations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Signatures of Electron-boson Coupling in the Half-metallic Ferromagnet Mn5Ge3: Study of Electron Self-energy Sigma(w) Obtained from Infrared Spectroscopy

We report results of our infrared and optical spectroscopy study of a half-metallic ferromagnet Mn{sub 5}Ge{sub 3}. This compound is currently being investigated as a potential injector of spin-polarized currents into germanium. Infrared measurements have been performed over a broad frequency (70-50000 cm{sup -1}) and temperature (10-300 K) range. From the complex optical conductivity {sigma}({omega}), we extract the electron self-energy {Sigma}({omega}). The calculation of {Sigma}({omega}) is based on numerical algorithms for solution of systems of nonlinear equations. The obtained self-energy provides insight into electron correlations in Mn{sub 5}Ge{sub 3}. In particular, it reveals that charge carriers may be coupled to bosonic modes, possibly of magnetic origin.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with Low Transition-Edge-Sensor Transition Temperature

We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3-inch diameter, 1-inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inelastic cross sections from gamma-ray measurements

Measurements of gamma rays following neutron induced reactions have been studied with the Germanium Array for Neutron-induced Excitations (GEANIE) at the Los Alamos Neutron Science Center (LANSCE) for many years. Gamma-ray excitation functions and coincidence studies provide insight into nuclear reaction mechanisms as well as expanding our knowledge of energy levels and gamma-rays. Samples studied with Ge detectors at LANSCE range from Be to Pu. Fe, Cr and Ti have been considered for use as reference cross sections. An overview of the measurements and efforts to create a reliable neutron-induced gamma-ray reference cross section will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Accuracy U-235 Enrichment Verification Station for Low Enriched Uranium Alloys

The Y-12 National Security Complex is playing a role in the U.S. High Performance Research Reactor (USHPRR) Conversion program sponsored by the U.S. National Nuclear Security Administration's Office of Global Threat Reduction. The USHPRR program has a goal of converting remaining U.S. reactors that continue to use highly enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. The USHPRR program is currently developing a LEU Uranium-Molybdenum (U-Mo) monolithic fuel for use in the U.S. high performance research reactors.Y-12 is supporting both the fuel development and fuel fabrication efforts by fabricating low enriched U-Mo foils from its own source material for irradiation experiments and for optimizing the fabrication process in support of scaling up the process to a commercial production scale. Once the new fuel is qualified, Y-12 will produce and ship U-Mo coupons with verified 19.75% +0.2% - 0.3% U-235 enrichment to be fabricated into fuel elements for the USHPRRs. Considering this small enrichment tolerance and the transition into HEU being set strictly at 20% U-235, a characterization system with a measurement uncertainty of less than or equal to 0.1% in enrichment is desired to support customer requirements and minimize production costs. Typical uncertainty for most available characterization systems today is approximately 1-5%; therefore, a specialized system must be developed which results in a reduced measurement uncertainty. A potential system using a High-Purity Germanium (HPGe) detector has been procured, and tests have been conducted to verify its capabilities with regards to the requirements. Using four U-Mo enrichment standards fabricated with complete isotopic and chemical characterization, infinite thickness and peak-ratio enrichment measurement methods have been considered for use. As a result of inhomogeneity within the U-Mo samples, FRAM, an isotopic analysis software, has been selected for initial testing. A systematic approach towards observing effects on FRAM's enrichment analysis has been conducted with regards to count and dead time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Attributes from NMIS Time Coincidence, Fast-Neutron Imaging, Fission Mapping, And Gamma-Ray Spectrometry Data

This work tests a systematic procedure for analyzing data acquired by the Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory with fast-neutron imaging and high-purity germanium (HPGe) gamma spectrometry capabilities. NMIS has been under development by the US Department of Energy Office of Nuclear Verification since the mid-1990s, and prior to that by the National Nuclear Security Administration Y-12 National Security Complex, with NMIS having been used at Y-12 for template matching to confirm inventory and receipts. In this present work, a complete set of NMIS time coincidence, fast-neutron imaging, fission mapping, and HPGe gamma-ray spectrometry data was obtained from Monte Carlo simulations for a configuration of fissile and nonfissile materials. The data were then presented for analysis to someone who had no prior knowledge of the unknown object to accurately determine the description of the object by applying the previously mentioned procedure to the simulated data. The best approximation indicated that the unknown object was composed of concentric cylinders: a void inside highly enriched uranium (HEU) (84.7 {+-} 1.9 wt % 235 U), surrounded by depleted uranium, surrounded by polyethylene. The final estimation of the unknown object had the correct materials and geometry, with error in the radius estimates of material regions varying from 1.58% at best and 4.25% at worst; error in the height estimates varied from 2% to 12%. The error in the HEU enrichment estimate was 5.9 wt % (within 2.5Σ of the true value). The accuracies of the determinations could be adequate for arms control applications. Future work will apply this iterative reconstructive procedure to other unknown objects to further test and refine it.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Majorana Project

Working as part of a collaborative team, PNNL is bringing its signature capability in ultra-low-level detection to help search for a rare form of radioactive decay-never before detected-called "neutrinoless double beta decay" in germanium. If observed, it would demonstrate neutrinos are Majorana-type particles. This discovery would show neutrinos are unique among fundamental particles, having a property whereby the matter and anti-matter version of this particle are indistinguishable. Physicist John L. Orrell explains how they rely on the Shallow Underground Laboratory to conduct the research.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Pu-238 Heat Source Granule Containment

The Milliwatt Radioisotopic Themoelectric Generator (RTG) provides power for permissive-action links. Essentially these are nuclear batteries that convert thermal energy to electrical energy using a doped silicon-germanium thermopile. The thermal energy is provided by a heat source made of 238 Pu, in the form of 238 PuO 2 granules. The granules are contained by 3 layers of encapsulation. A thin T-111 liner surrounds the 238 PuO 2 granules and protects the second layer (strength member) from exposure to the fuel granules. An outer layer of Hastalloy-C protects the T-111 from oxygen embrittlement. The T-111 strength member is considered the critical component in this 238 PuO 2 containment system. Any compromise in the strength member seen during destructive testing required by the RTG surveillance program is characterized. The T-111 strength member is characterized through Scanning Electron Microscopy (SEM), and Metallography. SEM is used in the Secondary Electron mode to reveal possible grain boundary deformation and/or cracking in the region of the strength member weld. Deformation and cracking uncovered by SEM are further characterized by Metallography. Metallography sections are mounted and polished, observed using optical microscopy, then documented in the form of microphotographs. SEM mat further be used to examine polished Metallography mounts to characterize elements using the SEM mode of Energy Dispersive X-ray spectroscopy (EDS).

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the 235U Induced Fission Gamma-ray Spectrum as an Active Non-destructive Assay of Fresh Nucleear Fuel

Non-destructive assay is a powerful tool the International Atomic Energy Agency (IAEA) employs to verify adherence to safeguards agreements. Current IAEA veri- cation techniques for fresh nuclear fuel include passive gamma-ray spectroscopy to determine fuel enrichment. This technique suers from self-shielding and lakes the percision to detect diversion of central fuel rods. The aim of this research is to develop a new, more capable non-destructive analysis technique using active neutron interroga- tion of fuel assemblies and determining the yields of short-lived ssion products from high-resolution gamma-ray spectroscopy using high-purity germanium (HPGe). This paper reports results from irradiation of a one meter tall mock fresh fuel assembly with low enriched uranium (LEU) or depleted uranium (DU) rods using a down-scattered deuterium-tritium (D-T) neutron source. Both prompt and delayed gamma-ray spec- tra were collected as time-stamped list-mode data in a coax detector and without list mode data in a planar strip detector. No dierentiating signatures were observed in the prompt spectra in either detector; however, both detectors observed several short-lived ssion product signatures in LEU and not DU fuel, indicating that this technique has potential for determination of enrichment of fresh fuel assemblies. There were eight unique ssion products observed in the LEU spectra with the coax detector spectra, and three ssion products were observed in the LEU spectra with the strip detector.

Fission Gamma-ray Spectrum↗

Spatially-resolved HPGe Gamma-ray Spectroscopy of Swipe Samples

Measurement of swipe samples is a critical element of the National Technical Nuclear Forensics (NTNF) mission. A unique, portable, germanium gamma imager (GeGI-s) from PHDS Co may provide complementary information to current techniques for swipe sample screening. The GeGI-s is a modified version of the commercial GeGI-4, a planar HPGe detector, capable of several million counts per second across the whole detector. The GeGI-s detector is a prototype of a commercial off-the-shelf high rate GeGI. The high rate capability allows high-activity samples be placed directly on the face of the detector. Utilizing the high energy resolution and pixelization of the detector, the GeGI-s can generate isotope specific spatial maps of the materials on the swipe sample. To prove this technology is viable for such mapping, the GeGI-s detector response to spatially distributed events must be well characterized. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The response was found to be primarily uniform and symmetric, however two causes of non-uniformity were found. Both of these causes can ultimately be corrected for in off-line data analysis.

germanium gamma imager↗

2010 Review of neutron and non-neutron nuclear data

The results of a review and evaluation of neutron and non-neutron nuclear data published in the scientific literature over the past three years are presented. The status of new chemical elements is examined. Ten elements have had their atomic weight and uncertainty replaced by interval values of upper and lower bounds. Data on revised values for the isotopic composition of the elements are reviewed and new recommended values are presented for germanium. Radioactive half-lives are reviewed and latest values presented which include measurements on nuclides of interest and very long-lived nuclides such as double beta decay, double electron capture, long-lived alpha decay, and long-lived beta decay. The latest information and the status on the evaluation of atomic masses are discussed. Data from new measurements on the very heavy elements (trans-meitnerium elements) are discussed and tabulated. Data on various recent neutron cross-section and resonance integral measurements are also discussed and the latest measurements are tabulated in both cases. The JENDL-4.0 and ENDF/B-VII.1 nuclear data libraries are discussed. A new initiative on the existence and importance of isotopes is presented. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Waste Characterization Using Gamma Ray Spectrometry with Automated Efficiency Optimization - 13404

Gamma ray spectrometry using High Purity Germanium (HPGe) detectors is commonly employed in assaying radioactive waste streams from a variety of sources: nuclear power plants, Department of Energy (DOE) laboratories, medical facilities, decontamination and decommissioning activities etc. The radioactive material is typically packaged in boxes or drums (for e.g. B-25 boxes or 208 liter drums) and assayed to identify and quantify radionuclides. Depending on the origin of the waste stream, the radionuclides could be special nuclear materials (SNM), fission products, or activation products. Efficiency calibration of the measurement geometry is a critical step in the achieving accurate quantification of radionuclide content. Due to the large size of the waste items, it is impractical and expensive to manufacture gamma ray standard sources for performing a measurement based calibration. For well over a decade, mathematical efficiency methods such as those in Canberra's In Situ Object Counting System (ISOCS) have been successfully employed in the efficiency calibration of gamma based waste assay systems. In the traditional ISOCS based calibrations, the user provides input data such as the dimensions of the waste item, the average density and fill height of the matrix, and matrix composition. As in measurement based calibrations, the user typically defines a homogeneous matrix with a uniform distribution of radioactivity. Actual waste containers can be quite nonuniform, however. Such simplifying assumptions in the efficiency calibration could lead to a large Total Measurement Uncertainty (TMU), thus limiting the amount of waste that can be disposed of as intermediate or low activity level waste. To improve the accuracy of radionuclide quantification, and reduce the TMU, Canberra has developed the capability to optimize the efficiency calibration using the ISOCS method. The optimization is based on benchmarking the efficiency shape and magnitude to the data available in the analyzed gamma ray spectra. Data from measurements of a given item in multiple counting geometries are among the powerful benchmarks that could be used in the optimization. Also, while assaying a waste stream with fission products and activation products emitting gamma lines of multiple energies, optimizing the efficiency on the basis of line activity consistency is very effective. In the present paper, the ISOCS- based optimization methodology is applied to measurement scenarios involving multiple counting geometries, and multi-gamma-line radionuclides. Results will be presented along with accuracy and precision estimates for each measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Screening and Spectral Summing of LANL Empty Waste Drums - 13226

Empty 55-gallon drums that formerly held transuranic (TRU) waste (often over-packed in 85- gallon drums) are generated at LANL and require radiological characterization for disposition. These drums are typically measured and analyzed individually using high purity germanium (HPGe) gamma detectors. This approach can be resource and time intensive. For a project requiring several hundred drums to be characterized in a short time frame, an alternative approach was developed. The approach utilizes a combination of field screening and spectral summing that was required to be technically defensible and meet the Nevada Nuclear Security Site (NNSS) Waste Acceptance Criteria (WAC). In the screening phase of the operation, the drums were counted for 300 seconds (compared to 600 seconds for the typical approach) and checked against Low Level (LL)/TRU thresholds established for each drum configuration and detector. Multiple TRU nuclides and multiple gamma rays for each nuclide were evaluated using an automated spreadsheet utility that can process data from up to 42 drums at a time. Screening results were reviewed by an expert analyst to confirm the field LL/TRU determination. The spectral summing analysis technique combines spectral data (channel-by-channel) associated with a group of individual waste containers producing a composite spectrum. The grouped drums must meet specific similarity criteria. Another automated spreadsheet utility was used to spectral sum data from an unlimited number of similar drums grouped together. The composite spectrum represents a virtual combined drum for the group of drums and was analyzed using the SNAP{sup TM}/Radioassay Data Sheet (RDS)/Batch Data Report (BDR) method. The activity results for a composite virtual drum were divided equally amongst the individual drums to generate characterization results for each individual drum in the group. An initial batch of approximately 500 drums were measured and analyzed in less than 2 months in 2011. A second batch of approximately 500 more drums were measured and analyzed during the following 2 1/2 months. Four different HPGe detectors were employed for the operation. The screening and spectral summing approach can reduce the overall measurement and analysis time required. However, developing the technical details and automation spreadsheets requires a significant amount of expert time prior to beginning field operations and must be considered in the overall project schedule. This approach has continued to be used for characterizing several hundred more empty drums in 2012 and is planned to continue in 2013. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗