Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Numerical solutions for viscous and potential flow about arbitrary two-dimensional bodies using body-fitted coordinate systems

A procedure for numerical solution of the time-dependent, incompressible Navier-Stokes equations for the flow about arbitrarily shaped two-dimensional bodies is given. This solution is based on a technique of automatic numerical generation of a curvilinear coordinate system having a coordinate line coincident with the body contour regardless of its shape. The implicit solution utilizes the vorticity-stream function formulation with a false-position iterative adjustment of the surface vorticity in satisfaction of the no-slip boundary condition. Excellent agreement with the Blasius boundary layer solution is obtained for a semi-infinite flat plate. Results are presented for Reynolds numbers up to 2000 for several airfoils and a cambered rock.

Thames, F. C.↗

An experimental investigation of a three-dimensional wall jet

An experimental investigation of the effects of a curved and flat wall surface on the flow development of an axisymmetric jet exhausting into a moving airstream has been made. Of primary concern was the comparison of the one-point statistical properties of the unconfined jet to the quantities measured in the flows over a flat plate and a curved wall surface. Quantities measured in this investigation included mean velocities in all three directions, turbulent intensities, autocorrelations, power spectral densities, and intermittencies. The investigation was confined to the near field of the turbulent jet. The curved wall (flap) was found to have a very large effect on both the mean velocity and the turbulent velocity components of the flowfield. The potential core region of the jet was found to break up most rapidly for the flow over the flap. A laser-Doppler velocimeter, using a phase locked-loop processor, was used to make the desired velocity field measurements. To determine the intermittency profiles, a laser light scattering technique was employed.

Catalano, G. D.↗

An efficient numerical method for solving the time-dependent compressible Navier-Stokes equations at high Reynolds number

A fine-mesh method incorporating two new operators, which drastically reduces the computation time, has been developed for solving the time-dependent Navier-Stokes equations at flight Reynolds numbers. The approach time-splits the equations into a hyperbolic part and a parabolic part, solves the hyperbolic part by a new explicit numerical method based on characteristics theory, and solves the parabolic part by a new efficient implicit parabolic method. The method has reduced the computation time by one and two orders of magnitude from that required previously to solve for the interaction of a shock wave with a boundary layer on a flat plate.

Maccormack, R. W.↗

Considerations in the development of a high performance per unit cost solar collector

A flat plate collector employing a mild steel, pressure-expanded absorber plate has been developed. It is capable of energy output levels commensurate with the requirements of driving an absorption refrigeration system while operating at efficiency levels in the 35-40% range. Selective absorber surfaces of black chrome over nickel and black copper over copper were analyzed and prototype collectors containing each type of absorber plating were fabricated and tested for performance. Criteria applied to the cost effectiveness analysis of the collector included both the energy output per unit area and the collector fabrication cost per unit area.

Sims, W. H.↗

Performance correlations of five solar collectors tested simultaneously outdoors

Collector thermal efficiency, and efficiency degradation with time were measured for 5 flat-plate solar collectors tested simultaneously in an outdoor solar collector test facility. Results indicate that by using collector performance parameters which account for diffuse insolation, outdoor data recorded on 'cloudy' days can be used as a measure of performance, as long as the ratio of direct to total insolation exceeds approximately 0.6. These outdoor results also show good agreement with thermal efficiency data obtained indoors in a solar simulator. Significant efficiency degradation occurred on only one of the five collectors exposed to outdoor conditions for a period of one to two years.

Miller, D. R.↗

An experimental investigation of the trailing edge noise mechanism

An experimental investigation has been conducted to understand the physical mechanism of noise generation from a turbulent wall jet discharging over a flat plate and interacting with its sharp trailing edge. An aspect ratio 10 rectangular nozzle was used to provide the wall jet. Measurements made consist of farfield noise, surface pressure fluctuations, turbulent velocity fluctuations, and two-point space-time cross-correlations among these quantities. Results are presented which suggest strongly that the generation mechanism is the interaction of the convecting large scale quasi-orderly disturbance in the upper free shear layer of the wall jet with the trailing edge. The interaction also excites large scale strong vortical motion in the trailing edge wake. The dominant part of the sound field is highly coherent and in phase opposition across the trailing edge.

Yu, J. C.↗

Improved double-pass michelson interferometer

Interferometer design separates beams by offsetting centerlines of cat's-eye retroreflectors vertically rather than horizontally. Since beam splitter is insensitive to minimum-thickness condition in this geometry, relatively-low-cost, optically flat plate can be used.

Schindler, R. A.↗

Performance evaluation of an air solar collector

Indoor tests on signal-glazed flat-plate collector are described in report. Marhsall Space Flight Center solar simulator is used to make tests. Test included evaluations on thermal performance under various combinations of flow rate, incident flux, inlet temperature, and wind speed. Results are presented in graph/table form.

Source record↗

Development and testing of a hot-air solar collector

Summarized report on development and testing of hot-air flat-plate solar collector includes structural details, coating selection, and spacing between coating and glass plate. Report gives complete performance specifications and extensive certifications test report.

Caudle, J. M.↗

Effects of roughness size on the position of boundary-layer transition and on the aerodynamic characteristics of a 55 deg. swept delta wing at supersonic speeds

An experimental investigation was conducted to determine the effects of roughness size on the position of boundary layer transition and on the aerodynamic characteristics of a 55 deg swept delta wing model. Results are presented and discussed for wind tunnel tests conducted at free stream Mach numbers from 1.50 to 4.63, Reynolds numbers per meter from 3,300,000 to 1.6 x 10 to the 7th power, angles of attack from -8 to 16 deg, and roughness sizes ranging from 0.027 cm sand grit to 0.127 cm high cylinders. Comparisons were made with existing flat plate data. An approximate method was derived for predicting the drag of roughness elements used in boundary layer trips.

Stallings, R. L., Jr.↗

Standardization of computational experiments in unsteady turbulent boundary-layer flow

Numerical experiments are proposed as standard cases to be computed by all who plan to analyze unsteady turbulent boundary layer behavior. In this way, differences between the results obtained by various methods can be compared in a completely defined environment. The test cases range in difficulty from time relaxation study of the steady flow on a flat plate to the analysis of unsteady reversed flow. Initial and boundary conditions are fully defined for each case and representative outputs are presented. It is recommended that tabulated samples of computations of these test cases be published in a compendium of results.

Carr, L. W.↗

Analysis of spread multi-jet VTOL aircraft in hover

An investigation of vertical takeoff and landing aircraft lift losses in hover was conducted to evaluate a method for a simplified test technique. Three flat plate models were tested to determine their usefulness in predicting hover characteristics by comparing results between plate and three-dimensional models. Data obtained for the plate models were correlated to three-dimensional results by the application of a geometrical equivalent height correction factor. The correlation of plate and tunnel models indicated that lift losses in ground effect were essentially independent of the efflux characteristics for the engine simulators.

Albang, L. F.↗

MSFC hot air collectors. Phase 1: Test report

A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

Losey, R.↗

Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector

The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

Shih, K.↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Evacuated load-bearing high performance insulation study

A light weight, vacuum jacketed, load bearing cryogenic insulation system was developed and tested on a 1.17-m (46-in.) spherical test tank. The vacuum jacket consists of 0.08 mm (0.003 in.) thick 321 stainless steel formed into a wedge design that allows elastic jacket movements as the tank shrinks (cools) or expands (warms up or is pressurized). Hollow glass spheres, approximately 80 micrometers in diameter with a bulk density of 0.069 g/cc (4.3 lb cubic foot), provide the insulating qualities and one atmosphere load bearing capability required. The design, fabrication, and test effort developed the manufacturing methods and engineering data needed to scale the system to other tank sizes, shapes, and applications. The program demonstrated that thin wall jackets can be formed and welded to maintain the required vacuum level of .013 Pa yet flex elastically for multiple reuses. No significant shifting or breakage of the microspheres occurred after 13 simulated Space Tug flight cycles on the test tank and a hundred 1 atmosphere load cycles in a flat plate calorimeter. The test data were then scaled to the Space Tug LO2 and LH2 tanks, and weight, thermal performance, payload performance, and costs were compared with a helium purged multilayer insulation system.

Parmley, R. T.↗

Indoor thermal performance evaluation of Daystar solar collector

The test procedures used and results obtained from a test program to obtain thermal performance data on a Daystar Model 21B, S/N 02210, Unit 2, liquid solar collector under simulated conditions are described. The test article is a flat plate solar collector using liquid as a heat transfer medium. The absorber plate is copper and coated with black paint. Between the tempered low iron glass and absorber plate is a polycarbonate trap used to suppress convective heat loss. The collector incorporates a convector heat dump panel to limit temperature excursions during stagnation. The following tests were conducted: (1) collector thermal efficiency; (2) collector time constant; (3) collector incident angle modifier; (4) collector heat loss coefficient; and (5) collector stagnation.

Shih, K., Sr.↗

Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗