Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FALL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements and simulations of focused beam for orthovoltage therapy

Purpose: Megavoltage photon beams are typically used for therapy because of their skin-sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potential of low energy focused x-ray beams for radiation therapy was assessed. Methods: A polycapillary optic was used to focus the x-ray beam from a tungsten source. The optic was characterized and measurements were performed at 50 kV. PMMA blocks of varying thicknesses were placed between optic and the focal spot to observe any variation in the focusing of the beam after passing through the tissue-equivalent material. The measured energy spectrum was used to model the focused beam in MCNP5. A source card (SDEF) in MCNP5 was used to simulate the converging x-ray beam. Dose calculations were performed inside a breast tissue phantom. Results: The measured focal spot size for the polycapillary optic was 0.2 mm with a depth of field of 5 mm. The measured focal spot remained unchanged through 40 mm of phantom thickness. The calculated depth dose curve inside the breast tissue showed a dose peak several centimeters below the skin with a sharp dose fall off around the focus. The percent dose falls below 10% within 5 mm of the focus. It was shown that rotating the optic during scanning would preserve the skin-sparing effect of the focused beam. Conclusions: Low energy focused x-ray beams could be used to irradiate tumors inside soft tissue within 5 cm of the surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-112: Dose Distribution of Praseodymium-142 Microspheres in Microcapillary Using Radiochromic Film Dosimetry and Applications in Hepatocellular Carcinoma Microsphere Brachytherapy

Purpose: This work verified simulations of beta-minus emitter Praseodymium-142 (Pr-142) for microsphere brachytherapy by performing absolute dose measurements for Pr 142 microspheres in a microcapillary as a simplified model for a single blood vessel for the treatment of Hepatocellular Carcinoma (HCC). Methods: Pr-142 microspheres (mass: 0.169g, average diameter: 29.7±3.9μm) were activated by thermal neutron activation at the University of Missouri Research Reactor. Experimental setup consisted of a microsphere solution (initial activity 36.6mCi in 0.1ml of sterile water) within a glass microcapillary (internal and external diameter: 305μm and 453μm, respectively) placed for 51h in a custom made Gammex Solid Water™ phantom. GAFCHROMIC™ EBT2 film calibrated with a 6MeV electron beam was used to access the dose fall-off of microspheres. The microcapillary was modeled in MCNPX2.6 in order to compare with experiments. Results: The radial dose fall-off on the transverse plane due to scatter and attenuation in the solid water phantom was analyzed using ImageJ for both film and MCNPX2.6 simulations. Isodose analysis showed close agreement among the methods used, i.e. measurements and simulations agree within 3.9% for doses below 1600cGy. Experimental and simulated doses obtained at 0.5 cm radially from the source were 1547cGy and 1610cGy respectively. Discrepancies for points close to the microcapillary surface were observed between MCNPX2.6 and measurements due to film saturation for high doses. Dose due to Pr-142 3.7% gamma emission was below the threshold of detection for the film. Conclusion: A detailed dosimetric study was performed for Pr-142 glass microspheres within a single microcapillary. MCNPX2.6 simulations were verified by means of direct measurement. Based on these results, Pr-142 appears to be a viable choice of radionuclide for treating HCC.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-287: Robustness Study of Passive-Scattering Proton Therapy in Lung: Is Range and Setup Uncertainty Calculation On the Initial CT Enough to Predict the Plan Robustness?

Purpose: Plan robustness of the passive-scattering proton therapy treatment of lung tumors has been studied previously using combined uncertainties of 3.5% in CT number and 3 mm geometric shifts. In this study, we investigate whether this method is sufficient to predict proton plan robustness by comparing to plans performed on weekly verification CT scans. Methods: Ten lung cancer patients treated with passive-scattering proton therapy were randomly selected. All plans were prescribed 6660cGy in 37 fractions. Each initial plan was calculated using +/− 3.5% range and +/− 0.3cm setup uncertainty in x, y and z directions in Eclipse TPS(Method-A). Throughout the treatment course, patients received weekly verification CT scans to assess the daily treatment variation(Method-B). After contours and imaging registrations are verified by the physician, the initial plan with the same beamline and compensator was mapped into the verification CT. Dose volume histograms (DVH) were evaluated for robustness study. Results: Differences are observed between method A and B in terms of iCTV coverage and lung dose. Method-A shows all the iCTV D95 are within +/− 1% difference, while 20% of cases fall outside +/−1% range in Method-B. In the worst case scenario(WCS), the iCTV D95 is reduced by 2.5%. All lung V5 and V20 are within +/−5% in Method-A while 15% of V5 and 10% of V20 fall outside of +/−5% in Method-B. In the WCS, Lung V5 increased by 15% and V20 increased by 9%. Method A and B show good agreement with regard to cord maximum and Esophagus mean dose. Conclusion: This study suggests that using range and setup uncertainty calculation (+/−3.5% and +/−3mm) may not be sufficient to predict the WCS. In the absence of regular verification scans, expanding the conventional uncertainty parameters(e.g., to +/−3.5% and +/−4mm) may be needed to better reflect plan actual robustness.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-02: Sirius MRI Markers for Prostate Post-Implant Assessment: MR Protocol Development

Purpose: Currently, CT is used to visualize prostate brachytherapy sources, at the expense of accurate structure contouring. MRI is superior to CT for anatomical delineation, but the sources appear as voids on MRI images. Previously we have developed Sirius MRI markers (C4 Imaging) to replace spacers to assist source localization on MRI images. Here we develop an MRI pulse sequence protocol that enhances the signal of these markers to enable MRI-only post-implant prostate dosimetric analysis. Methods: To simulate a clinical scenario, a CIRS multi-modality prostate phantom was implanted with 66 markers and 86 sources. The implanted phantom was imaged on both 1.5T and 3.0T GE scanners under various conditions, different pulse sequences (2D fast spin echo [FSE], 3D balanced steadystate free precession [bSSFP] and 3D fast spoiled gradient echo [FSPGR]), as well as varying amount of padding to simulate various patient sizes and associated signal fall-off from the surface coil elements. Standard FSE sequences from the current clinical protocols were also evaluated. Marker visibility, marker size, intra-marker distance, total scan time and artifacts were evaluated for various combinations of echo time, repetition time, flip angle, number of excitations, bandwidth, slice thickness and spacing, fieldof- view, frequency/phase encoding steps and frequency direction. Results: We have developed a 3D FSPGR pulse sequence that enhances marker signal and ensures the integrity of the marker shape while maintaining reasonable scan time. For patients contraindicated for 3.0T, we have also developed a similar sequence for 1.5T scanners. Signal fall-off with distance from prostate to coil can be compensated mainly by decreasing bandwidth. The markers are not visible using standard FSE sequences. FSPGR sequences are more robust for consistent marker visualization as compared to bSSFP sequences. Conclusion: The developed MRI pulse sequence protocol for Sirius MRI markers assists source localization to enable MRIonly post-implant prostate dosimetric analysis. S.J. Frank is a co-founder of C4 Imaging (manufactures the MRI markers)

60 APPLIED LIFE SCIENCES↗

Maximizing the probability of satisfying the clinical goals in radiation therapy treatment planning under setup uncertainty

Purpose: This paper introduces a method that maximizes the probability of satisfying the clinical goals in intensity-modulated radiation therapy treatments subject to setup uncertainty. Methods: The authors perform robust optimization in which the clinical goals are constrained to be satisfied whenever the setup error falls within an uncertainty set. The shape of the uncertainty set is included as a variable in the optimization. The goal of the optimization is to modify the shape of the uncertainty set in order to maximize the probability that the setup error will fall within the modified set. Because the constraints enforce the clinical goals to be satisfied under all setup errors within the uncertainty set, this is equivalent to maximizing the probability of satisfying the clinical goals. This type of robust optimization is studied with respect to photon and proton therapy applied to a prostate case and compared to robust optimization using an a priori defined uncertainty set. Results: Slight reductions of the uncertainty sets resulted in plans that satisfied a larger number of clinical goals than optimization with respect to a priori defined uncertainty sets, both within the reduced uncertainty sets and within the a priori, nonreduced, uncertainty sets. For the prostate case, the plans taking reduced uncertainty sets into account satisfied 1.4 (photons) and 1.5 (protons) times as many clinical goals over the scenarios as the method taking a priori uncertainty sets into account. Conclusions: Reducing the uncertainty sets enabled the optimization to find better solutions with respect to the errors within the reduced as well as the nonreduced uncertainty sets and thereby achieve higher probability of satisfying the clinical goals. This shows that asking for a little less in the optimization sometimes leads to better overall plan quality.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-145: Validation of An Analytical Model for in Vivo Range Verification Using GATE Monte Carlo Simulation in Proton Therapy

Purpose: Predicted PET images on the basis of analytical filtering approach for proton range verification has been successful developed and validated using FLUKA Monte Carlo (MC) codes and phantom measurements. The purpose of the study is to validate the effectiveness of analytical filtering model for proton range verification on GATE/GEANT4 Monte Carlo simulation codes. Methods: In this study, we performed two experiments for validation of predicted β+-isotope by the analytical model with GATE/GEANT4 simulations. The first experiments to evaluate the accuracy of predicting β+-yields as a function of irradiated proton energies. In second experiment, we simulate homogeneous phantoms of different materials irradiated by a mono-energetic pencil-like proton beam. The results of filtered β+-yields distributions by the analytical model is compared with those of MC simulated β+-yields in proximal and distal fall-off ranges. Results: The results investigate the distribution between filtered β+-yields and MC simulated β+-yields distribution in different conditions. First, we found that the analytical filtering can be applied over the whole range of the therapeutic energies. Second, the range difference between filtered β+-yields and MC simulated β+-yields at the distal fall-off region are within 1.5mm for all materials used. The findings validated the usefulness of analytical filtering model on range verification of proton therapy on GATE Monte Carlo simulations. In addition, there is a larger discrepancy between filtered prediction and MC simulated β+-yields using GATE code, especially in proximal region. This discrepancy might Result from the absence of wellestablished theoretical models for predicting the nuclear interactions. Conclusion: Despite the fact that large discrepancies of the distributions between MC-simulated and predicted β+-yields were observed, the study prove the effectiveness of analytical filtering model for proton range verification using GATE Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-06: A Comparison of CT Number to Relative Linear Stopping Power Conversion Curves Used by Proton Therapy Centers

Purpose: To compare the CT Number (CTN) to Relative Linear Stopping Power (RLSP) conversion curves used by 14 proton institutions in their dose calculations. Methods: The proton institution’s CTN to RLSP conversion curves were collected by the Imaging and Radiation Oncology Core (IROC) Houston QA Center during its on-site dosimetry review audits. The CTN values were converted to scaled CT Numbers. The scaling assigns a CTN of 0 to air and 1000 to water to allow intercomparison. The conversion curves were compared and the mean curve was calculated based on institutions’ predicted RLSP values for air (CTN 0), lung (CTN 250), fat (CTN 950), water (1000), liver (CTN 1050), and bone (CTN 2000) points. Results: One institution’s curve was found to have a unique curve shape between the scaled CTN of 1025 to 1225. This institution modified its curve based on the findings. Another institution had higher RLSP values than expected for both low and high CTNs. This institution recalibrated their two CT scanners and the new data placed their curve closer to the mean of all institutions. After corrections were made to several conversion curves, four institutions still fall outside 2 standard deviations at very low CTNs (100–200), and two institutions fall outside between CTN 850–900. The largest percent difference in RLSP values between institutions for the specific tissues reviewed was 22% for the lung point. Conclusion: The review and comparison of CTN to RLSP conversion curves allows IROC Houston to identify any outliers and make recommendations for improvement. Several institutions improved their clinical dose calculation accuracy as a Result of this review. There is still area for improvement, particularly in the lung area of the curve. The IROC Houston QA Center is supported by NCI grant CA180803.

60 APPLIED LIFE SCIENCES↗

Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase–space off-axis and in the outputs for the 6 MeV phase–space.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-181: Proton Therapy Tissue-Equivalence of 3D Printed Materials

Purpose: This work investigated the proton tissue-equivalence of various 3D printed materials. Methods: Three 3D printers were used to create 5 cm cubic phantoms made of different plastics with varying percentages of infill. White resin, polylactic acid (PLA), and NinjaFlex plastics were used. The infills ranged from 15% to 100%. Each phantom was scanned with a CT scanner to obtain the HU value. The relative linear stopping power (RLSP) was then determined using a multi-layer ion chamber in a 200 MeV proton beam. The RLSP was measured both parallel and perpendicular to the print direction for each material. Results: The HU values of the materials ranged from lung-equivalent (−820 HU σ160) when using a low infill, to soft-tissue-equivalent 159 (σ12). The RLSP of the materials depended on the orientation of the beam relative to the print direction. When the proton beam was parallel to the print direction, the RLSP was generally higher than the RLSP in the perpendicular orientation, by up to 45%. This difference was smaller (less than 6%) for the materials with 100% infill. For low infill cubes irradiated parallel to the print direction, the SOBP curve showed extreme degradation of the beam in the distal region. The materials with 15–25% infill had wide-ranging agreement with a clinical HU-RLSP conversion curve, with some measurements falling within 1% of the curve and others deviating up to 45%. The materials with 100% infill all fell within 7% of the curve. Conclusion: While some materials tested fall within 1% of a clinical HU-RLSP curve, caution should be taken when using 3D printed materials with proton therapy, as the orientation of the beam relative to the print direction can result in a large change in RLSP. Further investigation is needed to measure how the infill pattern affects the material RLSP. This work was supported by PHS grant CA180803.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-08: Distribution of the Deviation Index (DI) in Digital Radiography Practices Across the United States

Purpose: To characterize the distribution of the deviation index (DI) in digital radiography practices across the United States. Methods: DI data was obtained from 10 collaborating institutions in the United States between 2012 and 2015. Each institution complied with the requirements of the Institutional Review Board at their site. DI data from radiographs of the body parts chest, abdomen, pelvis and extremity were analyzed for anteroposterior, posteroanterior, lateral, and decubitus views. The DI data was analyzed both in aggregate and stratified by exposure control method, image receptor technology, patient age, and participating site for each body part and view. The number of exposures with DI falling within previously published control limits for DI and descriptive statistics were calculated. Results: DI data from 505,930 radiographic exposures was analyzed. The number of exposures with DI falling within published control limits for DI varied from 10 to 20% for adult patients and 10 to 23% for pediatric patients for different body parts and views. Mean DI values averaged over other parameters for radiographs of the abdomen, chest, pelvis, and extremities ranged from 0.3 to 1.0, −0.6 to 0.5, 0.8, and −0.9 to 0.5 for the different adult views and ranged from −1.6 to −0.1, −0.3 to 0.5, −0.1, −0.2 to 1.4 for the different pediatric views, respectively (DI data was solicited only for anteroposterior view of pelvis). Standard deviation values of DI from individual sites ranged from 1.3 to 3.6 and 1.3 to 3.0 for the different adult and pediatric views, respectively. Also of interest was that target exposure indicators varied by up to a factor of 6 between sites for certain body parts and views. Conclusion: Previously published DI control limits do not reflect the state of clinical practice in digital radiography. Mean DI and target exposure indicators are targets for quality improvement efforts in radiography.

60 APPLIED LIFE SCIENCES↗

Crystal and molecular structure of Sr{sub 2}(Edta) . 5H{sub 2}O, Sr{sub 2}(H{sub 2}Edta)(HCO{sub 3}){sub 2} . 4H{sub 2}O, and Sr{sub 2}(H{sub 2}Edta)Cl{sub 2} . 5H{sub 2}O strontium ethylenediaminetetraacetates

Three Sr{sup 2+} compounds with the Edta{sup 4-} and H{sub 2}Edta{sup 2-} ligands-Sr{sub 2}(Edta) . 5H{sub 2}O (I), Sr{sub 2}(H{sub 2}Edta)(HCO{sub 3}){sub 2} . 4H{sub 2}O (II), and Sr{sub 2}(H{sub 2}Edta)Cl{sub 2} . 5H{sub 2}O (III)-are synthesized, and their crystal structures are studied. In I, the Sr(1) atom is coordinated by the hexadentate Edta{sup 4-} ligand following the 2N + 4O pattern and by two O atoms of the neighboring ligands, which affords the formation of zigzag chains. The Sr(2) atom forms bonds with O atoms of five water molecules and attaches itself to a chain via bonds with three O atoms of the Edta{sup 4-} ligands. The Sr(1)-O and Sr(2)-O bond lengths fall in the ranges 2.520(2)-2.656(3) and 2.527(3)-2.683(2) A, respectively. The Sr(1)-N bonds are 2.702(3) and 2.743(3) A long. In II and III, the H{sub 2}Edta{sup 2-} anions have a centrosymmetric structure with the trans configuration of the planar ethylenediamine fragment. The N atoms are blocked by acid protons. In II, the environment of the Sr atom is formed by six O atoms of three H{sub 2}Edta ligands, two O atoms of water molecules, and an O atom of the bicarbonate ion, which is disordered over two positions. In III, the environment of the Sr atom includes six O atoms of four H{sub 2}Edta{sup 2-} ligands and three O atoms of water molecules. The coordination number of the Sr atoms is equal to 8 + 1. In II and III, the main bonds fall in the ranges 2.534(3)-2.732(2) and 2.482(2)-2.746(3) A, whereas the ninth bond is elongated to 2.937(3) and 3.055(3) A, respectively. In II, all the structural elements are linked into wavy layers. The O-H-O interactions contribute to the stabilization of the layer and link neighboring layers. In III, hydrated Sr{sup 2+} cations and H{sub 2}Edta{sup -} anions form a three-dimensional [Sr{sub 2}(H{sub 2}Edta)(H{sub 2}O){sub 3}]{sub n}{sup 2n+} framework. The Cl{sup -} anions are fixed in channels of the framework by hydrogen bonds with four water molecules. In II and III, the N-H groups form four-center N-H-O{sub 3} hydrogen bonds, which include one intermolecular and two intramolecular components. PACS numbers: 61.66.Hq.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

De sitter space and perpetuum mobile

The general arguments that any interacting nonconformal classical field theory in de Sitter space leads to the possibility of constructing a perpetuum mobile is given. The arguments are based on the observation that massive free falling particles can radiate other massive particles on the classical level as seen by the free falling observer. The intensity of the radiation process is not zero even for particles with any finite mass, i.e., with a wavelength which is within causal domain. Hence, we conclude that either de Sitter space cannot exist eternally or that one can build a perpetuum mobile.

79 ASTRONOMY AND ASTROPHYSICS↗

Precise polarization measurements via detection of compton scattered electrons

The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the transverse momentum and Φ$*\atop{η}$ distributions of Drell–Yan lepton pairs in proton–proton collisions at √s=8 TeV with the ATLAS detector

Distributions of transverse momentum p$ℓℓ\atop{T}$ and the related angular variable Φ$*\atop{η}$ of DrellΓÇôYan lepton pairs are measured in 20.3$\perp$áfb -1 of protonΓÇôproton collisions at √s=8$\perp$áTeV with the ATLAS detector at the LHC. Measurements in electron-pair and muon-pair final states are corrected for detector effects and combined. Compared to previous measurements in protonΓÇôproton collisions at √s=7$\perp$áTeV, these new measurements benefit from a larger data sample and improved control of systematic uncertainties. Measurements are performed in bins of lepton-pair mass above, around and below the Z-boson mass peak. The data are compared to predictions from perturbative and resummed QCD calculations. For values of Φ$*\atop{η}$<1 the predictions from the Monte Carlo generator ResBos are generally consistent with the data within the theoretical uncertainties. However, at larger values of Φ$*\atop{η}$ this is not the case. Monte Carlo generators based on the parton-shower approach are unable to describe the data over the full range of pℓℓTpTℓℓ while the fixed-order prediction of Dynnlo falls below the data at high values of p$ℓℓ\atop{T}$ . ResBos and the parton-shower Monte Carlo generators provide a much better description of the evolution of the Φ$*\atop{η}$ and p$ℓℓ\atop{T}$ distributions as a function of lepton-pair mass and rapidity than the basic shape of the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Four metrics

A central idea in general relativity is that physics should not depend on the spacetime coordinates in use. But the qualitative description of various phenomena can appear superficially quite different. Furthermore, we consider falling into a classical black hole using four distinct but equivalent metrics. First is the Schwarzschild case, with extreme time dilation at the horizon. Second, rescaling the dilation allows falling into the hole in finite proper time. Third, time and space are rescaled into a Penrose motivated picture where light trajectories all have unit slope. Fourth, a white hole variation of the second metric allows passage out through the horizon, with reentry forbidden.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Space cannot stretch too fast

Here, in this paper, we argue that black holes microstates leave an imprint on the gravitational vacuum through their virtual fluctuations. This imprint yields a power law fall off — rather than an exponential fall off — for the entanglement of planck scale fluctuations at different points. These entanglements generate an extra energy when space stretches too fast, since causality prevents a relaxation of these entanglements to their vacuum values. We obtain semiclassical dynamics for slow processes like star formation, but a radical departure from semiclassicality when a black hole horizon forms even though curvatures remain low everywhere. This resolution of the information puzzle also implies an extra energy source at the scale of the cosmological horizon, which may explain the mysteries of dark energy and the Hubble tension.

black holes↗