Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

A Verification Suite of Test Cases for the Barotropic Solver of Ocean Models

Abstract The development of any atmosphere or ocean model warrants a suite of test cases (TCs) to verify its spatial and temporal discretizations, order of accuracy, stability, reproducibility, portability, scalability, etc. In this paper, we present a suite of shallow water TCs designed to verify the barotropic solver of atmosphere and ocean models. These include the non‐dispersive coastal Kelvin wave; the dispersive inertia‐gravity wave; the dispersive planetary and topographic Rossby waves; the barotropic tide; and a non‐linear manufactured solution. These TCs check the implementation of the linear pressure gradient term; the linear constant or variable‐coefficient Coriolis and bathymetry terms; and the non‐linear advection terms. Simulation results are presented for a variety of time‐stepping methods as well as two spatial discretizations: a mimetic finite volume method based on the TRiSK scheme, and a high‐order discontinuous Galerkin spectral element method. The experimental procedure for conducting these numerical experiments is detailed. It underscores several key considerations that vary depending on the chosen spatial discretization method. Finally, convergence studies of every TC are conducted with refinement in both space and time, only in space, and only in time. The convergence slopes match the expected theoretical predictions.

54 ENVIRONMENTAL SCIENCES↗

Theoretical and experimental studies of the current–voltage and capacitance–voltage of HEMT structures and field-effect transistors

The sensitivity of classical n{sup +}/n{sup –} GaAs and AlGaN/GaN structures with a 2D electron gas (HEMT) and field-effect transistors based on these structures to γ-neutron exposure is studied. The levels of their radiation hardness were determined. A method for experimental study of the structures on the basis of a differential analysis of their current–voltage characteristics is developed. This method makes it possible to determine the structure of the layers in which radiation-induced defects accumulate. A procedure taking into account changes in the plate area of the experimentally measured barrier-contact capacitance associated with the emergence of clusters of radiation-induced defects that form dielectric inclusions in the 2D-electron-gas layer is presented for the first time.

36 MATERIALS SCIENCE↗

The momentum transfer of incompressible turbulent separated flow due to cavities with steps

An experimental study was conducted using a plate test bed having a turbulent boundary layer to determine the momentum transfer to the faces of step/cavity combinations on the plate. Experimental data were obtained from configurations including an isolated configuration and an array of blocks in tile patterns. A momentum transfer correlation model of pressure forces on an isolated step/cavity was developed with experimental results to relate flow and geometry parameters. Results of the experiments reveal that isolated step/cavity excrecences do not have a unique and unifying parameter group due in part to cavity depth effects and in part to width parameter scale effects. Drag predictions for tile patterns by a kinetic pressure empirical method predict experimental results well. Trends were not, however, predicted by a method of variable roughness density phenomenology.

White, R. E.↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

Unification of nonequilibrium molecular dynamics and the mode-resolved phonon Boltzmann equation for thermal transport simulations

Nano-size confinement induces many intriguing non-Fourier heat conduction phenomena, such as nonlinear temperature gradients, temperature jumps near the contacts, and size-dependent thermal conductivity. Over the past decades, these effects have been studied and interpreted by nonequilibrium molecular dynamics (NEMD) and phonon Boltzmann transport equation (BTE) simulations separately, but no theory that unifies these two methods has ever been established. In this work, we unify these methods using a quantitative mode-level comparison and demonstrate that they are equivalent for various thermostats. We show that different thermostats result in different non-Fourier thermal transport characteristics due to the different mode-level phonon excitations inside the thermostats, which explains the different size-dependent thermal conductivities calculated using different reservoirs, even though they give the same bulk thermal conductivity. Specifically, the Langevin thermostat behaves like a thermalizing boundary in phonon BTE and provides mode-level thermal-equilibrium phonon outlets, while the Nose-Hoover chain thermostat and velocity rescaling method behave like biased reservoirs, which provide a spatially uniform heat generation and mode-level nonequilibrium phonon outlets. These findings explain why different experimental measurement methods can yield different size-dependent thermal conductivity. They also indicate that the thermal conductivity of materials can be tuned for various applications by specifically designing thermostats. Finally, the unification of NEMD and phonon BTE will largely facilitate the study of thermal transport in complex systems in the future by, e.g., replacing computationally unaffordable first-principles NEMD simulations with computationally less expensive spectral BTE simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗

Practical model reduction for flexible structures

The most accepted methods for developing models of flexible structures for the analysis, design and simulation of control systems are finite element methods and extraction from experimental data. Using either of these methods, models are often produced with modes that do not significantly add to the fidelity of the model. This paper presents techniques for eliminating these modes. Particular attention is paid to multiple-input, multiple-output systems. First, control system models developed for flexible structures, using finite element methods and experimental data, are briefly discussed. the shortcomings of using models with unnecessary and/or residual modes are delineated. Then, two techniques for reducing the order of models are presented; the first is applicable to single-input, single-output systems and the second for multiple-input, multiple-output systems. Finally, both are illustrated using model data from the proposed NASA Shuttle-C.

Mitchell, Jerrel R.↗

Molecular level structure in water-alcohol mixtures; from shots to pints: L’Chaim!

The two objectives of this work are to look at the molecular level mixing in water-alcohol liquid mixtures and to determine how well the Effective Fragment Potential (EFP) method performs at describing small, heterogenous water-alcohol mixtures. In this work we look both at small clusters, size 2 – 24 molecules, as well as bulk mixtures, 64 or more molecules. For small clusters (2 – 24 molecules), the molecular structure was studied using the EFP method and MP2. Extensive Monte Carlo/simulated annealing (MC/SA) global optimizations were used to locate low energy structures for all water, alcohol, and water-alcohol mixtures. The alcohols studied include the small, straight-chain, primary alcohols: methanol, ethanol, propanol, and 1-butanol as well as the secondary alcohol 2-butanol, and tertiary butanol. It is shown that a number of low energy mixed clusters retain the structural characteristics of the pure clusters. It is also shown that the EFP method performs well at describing small, heterogenous water-alcohol mixtures. The molecular structure in bulk water, alcohol, and water-alcohol mixtures is studied with the EFP method and molecular dynamics simulations. Radial distribution functions are used to analyze structure and to benchmark the EFP method against experimental results. The effect of alcohol concentration and alcohol chain length on the local structure of water is investigated. Preliminary results indicate that the EFP method can potentially model bulk water-alcohol systems well as compared to experiment. Results on the effects of alcohol chain length are forthcoming.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Probabilistic Multi-Factor Interaction Model for Complex Material Behavior

Complex material behavior is represented by a single equation of product form to account for interaction among the various factors. The factors are selected by the physics of the problem and the environment that the model is to represent. For example, different factors will be required for each to represent temperature, moisture, erosion, corrosion, etc. It is important that the equation represent the physics of the behavior in its entirety accurately. The Multi-Factor Interaction Model (MFIM) is used to evaluate the divot weight (foam weight ejected) from the external launch tanks. The multi-factor has sufficient degrees of freedom to evaluate a large number of factors that may contribute to the divot ejection. It also accommodates all interactions by its product form. Each factor has an exponent that satisfies only two points - the initial and final points. The exponent describes a monotonic path from the initial condition to the final. The exponent values are selected so that the described path makes sense in the absence of experimental data. In the present investigation, the data used were obtained by testing simulated specimens in launching conditions. Results show that the MFIM is an effective method of describing the divot weight ejected under the conditions investigated. The problem lies in how to represent the divot weight with a single equation. A unique solution to this problem is a multi-factor equation of product form. Each factor is of the following form (1 xi/xf)ei, where xi is the initial value, usually at ambient conditions, xf the final value, and ei the exponent that makes the curve represented unimodal that meets the initial and final values. The exponents are either evaluated by test data or by technical judgment. A minor disadvantage may be the selection of exponents in the absence of any empirical data. This form has been used successfully in describing the foam ejected in simulated space environmental conditions. Seven factors were required to represent the ejected foam. The exponents were evaluated by least squares method from experimental data. The equation is used and it can represent multiple factors in other problems as well; for example, evaluation of fatigue life, creep life, fracture toughness, and structural fracture, as well as optimization functions. The software is rather simplistic. Required inputs are initial value, final value, and an exponent for each factor. The number of factors is open-ended. The value is updated as each factor is evaluated. If a factor goes to zero, the previous value is used in the evaluation.

Abumeri, Galib H.↗

Comparison of analytical and experimental subsonic steady and unsteady pressure distributions for a high-aspect-ratio-supercritical wing model with oscillating control surfaces

The results of a comparative study using the unsteady aerodynamic lifting surface theory, known as the Doublet Lattice method, and experimental subsonic steady- and unsteady-pressure measurements, are presented for a high-aspect-ratio supercritical wing model. Comparisons of pressure distributions due to wing angle of attack and control-surface deflections were made. In general, good correlation existed between experimental and theoretical data over most of the wing planform. The more significant deviations found between experimental and theoretical data were in the vicinity of control surfaces for both static and oscillatory control-surface deflections.

Mccain, W. E.↗

Estimating Pump Blockage

Blockage predicted for all components including inducers, impellers and diffusers. Pump performance predicted by semiempirical method shows excellent agreement with test results in Space Shuttle main-engine highpressure fuel turbopump. Comparisons of pump efficiency show equally good agreement of calculated values with experimental ones. Method improves current estimation methods based solely on subjective engineering judgment.

Chung, W.↗

A review of various flow-solid interaction analysis methods with emphasis on recent advances in turbulence models and flow analysis methods

A review on various experimental, analytical, and numerical methods for the flow-solid interaction of a nest of cylinders subjected to cross flow is presented in this paper. In order to assess the possibility of initiating a development of major numerical analysis method for flow-solid interaction of a nest of cylinders in cross flows, a review on various turbulence models, numerical methods such as the finite element method and the finite difference method, and the available numerical methods for flow-solid interactions have been included in this paper. A multiple-time-scale turbulence model for complex turbulent flows and a finite element method for high Reynolds number flows have been introduced herein for the same reason.

Kim, S.-W.↗

Monte Carlo simulations of the dose from imaging with GE eXplore 120 micro-CT using GATE

Purpose: Small animals are increasingly used as translational models in preclinical imaging studies involving microCT, during which the subjects can be exposed to large amounts of radiation. While the radiation levels are generally sublethal, studies have shown that low-level radiation can change physiological parameters in mice. In order to rule out any influence of radiation on the outcome of such experiments, or resulting deterministic effects in the subjects, the levels of radiation involved need to be addressed. The aim of this study was to investigate the radiation dose delivered by the GE eXplore 120 microCT non-invasively using Monte Carlo simulations in GATE and to compare results to previously obtained experimental values. Methods: Tungsten X-ray spectra were simulated at 70, 80, and 97 kVp using an analytical tool and their half-value layers were simulated for spectra validation against experimentally measured values of the physical X-ray tube. A Monte Carlo model of the microCT system was set up and four protocols that are regularly applied to live animal scanning were implemented. The computed tomography dose index (CTDI) inside a PMMA phantom was derived and multiple field of view acquisitions were simulated using the PMMA phantom, a representative mouse and rat. Results: Simulated half-value layers agreed with experimentally obtained results within a 7% error window. The CTDI ranged from 20 to 56 mGy and closely matched experimental values. Derived organ doses in mice reached 459 mGy in bones and up to 200 mGy in soft tissue organs using the highest energy protocol. Dose levels in rats were lower due to the increased mass of the animal compared to mice. The uncertainty of all dose simulations was below 14%. Conclusions: Monte Carlo simulations proved a valuable tool to investigate the 3D dose distribution in animals from microCT. Small animals, especially mice (due to their small volume), receive large amounts of radiation from the GE eXplore 120 microCT, which might alter physiological parameters in a longitudinal study setup.

60 APPLIED LIFE SCIENCES↗

Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation of interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of 'salt-and-pepper' noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain multiscale decomposition, the proposed method is anticipated to be useful in advanced clinical and preclinical applications where the interview sampling rate varies.

60 APPLIED LIFE SCIENCES↗

Theoretical study of IR and photoelectron spectra of small gallium-arsenide clusters

Relative stabilities of small Ga{sub n}As{sub m} clusters, as well as their structural electronic and vibrational properties, were computed and analysed using a CCSD(T) reference method since experimental data in this area are sparse or unknown. With the aim of investigating larger clusters, we explored several DFT functionals and basis sets able to mimic the reliable CCSD(T) approach. Among them, the PBE0/SBKJC+sp,d appears as the most efficient to describe the structural and vibrational properties since average differences of about 0.042Å and 5.1cm{sup −1} were obtained for bond lengths and fundamental vibrational frequencies, respectively for the first small clusters [1] of the series found from our GSAM method [2]. As further test, this model is used in order to investigate and revisit an experimental IR spectrum of Ga{sub n}As{sub m} mixture previously published by Li et al. [3]. More complicated is the difficulty which arises in the electronic description due to the presence of numerous low lying electronic states nearly degenerated to correctly describe the electronic structure. The case of Ga{sub 2}As will be discussed and the photoelectron spectra of the Ga{sub 2}As anion reanalyzed on the ground of our calculations [4] comparatively to the experimental spectra obtained by Neumark and co-workers [5].

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-energy electronic structure of perovskite and Ruddlesden-Popper semiconductors in the Ba-Zr-S system probed by bond-selective polarized x-ray absorption spectroscopy, infrared reflectivity, and Raman scattering

Chalcogenides in perovskite and the related layered Ruddlesden-Popper crystal structures ( chalcogenide perovskites for brevity) are an exciting family of semiconductors but remain experimentally little studied. Chalcogenide perovskites share crystal structures and some physical properties with ionic compounds such as oxide and halide perovskites, but the metal-chalcogen bonds responsible for semiconducting behavior are substantially more covalent than in these more-studied perovskites. In this study, we use complementary experimental and theoretical methods to study how the mixed ionic-covalent Zr-S bonds support the electronic structure and physical properties of perovskite BaZrS 3 and Ruddlesden-Popper Ba 3 Zr 2 S 7 . We apply theoretical methods to assign features of experimentally measured x-ray absorption spectroscopy (XAS) to particular orbital transitions, enabling a clear physical interpretation of angle-dependent, polarized XAS data measured on single-crystal samples, and an atomistic view of the covalent bonding network that facilitates charge transport. Polarized Raman measurements identify signatures of crystalline anisotropy in Ba 3 Zr 2 S 7 and enable the first assignments of mode symmetry in this material. Infrared reflectivity reveals electronic transport properties that augur well for the use of chalcogenide perovskites in optoelectronic and energy-conversion technologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗