Reliability and Safety Assessment of Urban Air Mobility Concept Vehicles

The following work was commissioned by the National Aeronautics and Space Administration (NASA) to guide industry and future regulation related to urban air mobility (UAM). Prior studies compared the relative safety of NASA concept vehicles, Figure ES1, designed for UAM and provided recommendations for industry research, aircraft architectural improvements, and regulatory updates. After the prior study completed, the European Aviation Safety Agency (EASA) released regulatory guidance in the form of a special condition (SC), SC-VTOL-01, for multirotors with distributed propulsion and flight controls (DPFC). The objective of the current work was to develop DPFC architectures that will comply with SC-VTOL-01. Vehicle designs, DPFC architectures, and stability & control (S&C) models were developed to find limitations and trends to guide industry. To guide this task, NASA developed quad, hex, and an octorotor to better define vehicle attributes and trade space. Aircraft for study included electric, hybrid-electric, and turboshaft powerplants and collective and RPM control schemes. Assessments are in terms of the safety level achieved, and/or aircraft component/features needed to meet SC-VTOL-01. The most challenging criteria being the catastrophic failure rate, ≤10-9 catastrophic failures per flight hour, and that no single failures may result in a catastrophic event. A disciplined process was followed, similar to that in Aerospace Recommended Practice (ARP) 4761. A preliminary system safety assessment (PSSA) leveraged prior work as a basis of creating failure rate budgets for system design teams. System designs were updated and iterated upon, working with reliability and safety subject matter experts to develop SC-VTOL-01 compliant designs. Design changes were reflected in updated PSSAs for initial verification of compliance. The DPFC architecture was broken into four system design teams, the (1) flight control system (FCS), (2) drive and power system, (3) thermal management system (TMS), and (4) electrical power and distribution system. The FCS including elements necessary to control the aircraft, drive and power including elements necessary to generate and transmit shaft power, the TMS including elements necessary to maintain temperature limits in all operating environments, and electrical pow-er and distribution including equipment necessary to store and transmit electrical energy. Results found that all aircraft evaluated may have paths to comply with SC-VTOL-01, Figure ES2. However, S&C models showed large power transients that must be addressed and PSSA results show that future work is needed in single load path structures, high voltage power storage and distribution, and in motor/rotor overspeed protection.

Boeing↗

Modeling Power System Operation with Intermittent Resources

Electricity generating companies and power system operators face the need to minimize total fuel cost or maximize total profit over a given time period. These issues become optimization problems subject to a large number of constraints that must be satisfied simultaneously. The grid updates due to smart-grid technologies plus the penetration of intermittent re- sources in electrical grid introduce additional complexity to the optimization problem. The Renewable Integration Model (RIM) is a computer model of interconnected power system. It is intended to provide insight and advice on complex power systems management, as well as answers to integration of renewable energy questions. This paper describes RIM basic design concept, solution method, and the initial suite of modules that it supports.

Marinovici, Maria C.↗

OSU High Temperature Test Facility Design Technical Report, Revision 2

The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Opportunities for low-carbon generation and storage technologies to decarbonise the future power system

Alternatives to cope with the challenges of high shares of renewable electricity in power systems have been addressed from different approaches, such as energy storage and low-carbon technologies. However, no model has previously considered integrating these technologies under stability requirements and different climate conditions. In this study, we include this approach to analyse the role of new technologies to decarbonise the power system. The Spanish power system is modelled to provide insights for future applications in other regions. After including storage and low-carbon technologies (currently available and under development), batteries and hydrogen fuel cells have low penetration, and the derived emission reduction is negligible in all scenarios. Compressed air storage would have a limited role in the short term, but its performance improves in the long term. Flexible generation technologies based on hydrogen turbines and long-duration storage would allow the greatest decarbonisation, providing stability and covering up to 11-14 % of demand in the short and long term. The hydrogen storage requirement is equivalent to 18 days of average demand (well below the theoretical storage potential in the region). When these solutions are considered, decarbonising the electricity system (achieving Paris targets) is possible without a significant increase in system costs (< 114 euro/MWh).

08 HYDROGEN↗

Power Systems Evaluated for Solar Electric Propulsion Vehicles

Solar electric propulsion (SEP) mission architectures are applicable to a wide range NASA missions including the robotic exploration of the outer planets in the next decade and the human exploration of Mars within the next 2 decades. SEP enables architectures that are very mass efficient with reasonable power levels (1-MW class) aerobrake and cryogenic upper-stage transportation technologies are utilized. In this architecture, the efficient SEP stage transfers the payload from low Earth orbit (LEO) High Energy Elliptical Parking Orbit (HEEPO) within a period of 6 to 12 months. highthrust, cryogenic upper stage and payload then separate from the SEP vehicle for injection to the planetary target, allowing for fast heliocentric trip times. This mission architecture offers a potential reduction in mass to LEO in comparison to alternative all-chemical nuclear propulsion schemes. Mass reductions may allow launch vehicle downsizing enable missions that would have been grounded because of cost constraints. The preceding figure illustrates a conceptual SEP stage design for a human Mars mission. Researchers at the NASA Glenn Research Center at Lewis Field designed conceptual SEP vehicle, conceived the mission architecture to use this vehicle, and analyzed the vehicle s performance. This SEP stage has a dry mass of 35 metric tons (MT), 40 MT of xenon propellant, and a photovoltaic array that spans 110 m, providing power to a cluster of eight 100-kW Hall thrusters. The stage can transfer an 80-MT payload and upper stage to the desired HEEPO. Preliminary packaging studies show this space-station-class SEP vehicle meets the proposed "Magnum" launch vehicle and volume requirements with considerable margin. An SEP vehicle for outer planetary missions, such as the Europa Mapper Mission, would be dramatically smaller than human Mars mission SEP stage. In this mission architecture, the SEP power system with the payload to provide spacecraft power throughout the mission. Several photovoltaic array design concepts were considered for the SEP vehicle power system for the human mission to Mars. These include a space station derivative, a SCARLET (Solar Concentrator Arrays with Refractive Linear Element Technology) derivative, and a hybrid inflatable-deployable thin polymer membrane array with thin-film solar cells (as shown in the concept illustration). This concept is based on a design developed for the Next Generation Space Telescope Sun shield. The array is divided into 16 independent electrical sections with 500-V, negative-grounded solar cell strings. The power system employs a channelized, 500-Vdc power management and distribution (PMAD) architecture with lithium ion batteries for energy storage for vehicle and payload secondary loads (the high-power Hall thrusters do not operate in eclipse periods). The 500-V PMAD voltage permits "direct-drive" thruster operation, greatly reducing the power processing unit size, complexity, and power loss. Similar power system architecture, designs, and technology are assumed for the Europa Mapper Mission SEP vehicle. The primary exceptions are that the photovoltaic array is assumed to consist of two rectangular wings and that the power system rating is 15 kW in Earth orbit and 200 W at Europa. To size the SEP vehicle power system, a dedicated Fortran code was developed to predict detailed power system performance, mass, and thermal control requirements. This code also modeled all the relevant Earth orbit environments; that is, the particulate radiation, plasma, meteoroids and debris, ultraviolet radiation, contamination, and thermal conditions. Analysis results for the Human Mars Mission SEP vehicle show a power system mass of 9-MT and photovoltaic array area of 5800-square meters for the thin-membrane design concept with CuInS2 thin-film cells. Power processing unit input power for a thin-membrane array design with three-junction, amorphous SiGe solar cells is shown in the graph. Power falls off rapidly inhe first weeks of the mission because of light-induced (Staebler-Wronksi) solar cell losses. During the next 200 days, power decreases steadily as the SEP stage spirals through the proton belts and sustains the bulk of the mission radiation damage. Once the vehicle apogee is above approximately four Earth radii, little additional degradation is incurred. From 400 to 800 days, a 1100-km "parking" orbit is maintained to await the next payload transfer opportunity. This orbit is below the main proton belt, and thus, little radiation dose is accumulated during this time period. During the second LEO-to-HEEPO transfer, power degrades somewhat further, but power requirements are still met. In comparison, the Europa Mapper SEP vehicle power system had a mass of 150 kg and a thin membrane array area of 100 square meters.

Kerslake, Thomas W.↗

Parallel Harmony Search Based Distributed Energy Resource Optimization

This paper presents a harmony search based parallel optimization algorithm to minimize voltage deviations in three phase unbalanced electrical distribution systems and to maximize active power outputs of distributed energy resources (DR). The main contribution is to reduce the adverse impacts on voltage profile during a day as photovoltaics (PVs) output or electrical vehicles (EVs) charging changes throughout a day. The IEEE 123- bus distribution test system is modified by adding DRs and EVs under different load profiles. The simulation results show that by using parallel computing techniques, heuristic methods may be used as an alternative optimization tool in electrical power distribution systems operation.

Ceylan, Oguzhan↗

Development of preliminary design concept for a multifunction display and control system for the Orbiter crew station. Task 4: Design concept recommendation

Application of multifunction display and control systems to the NASA Orbiter spacecraft offers the potential for reducing crew workload and improving the presentation of system status and operational data to the crew. A design concept is presented for the application of a multifunction display and control system (MFDCS) to the Orbital Maneuvering System and Electrical Power Distribution and Control System on the Orbiter spacecraft. The MFDCS would provide the capability for automation of procedures, fault prioritization and software reconfiguration of the MFDCS data base. The MFDCS would operate as a stand-alone processor to minimize the impact on the current Orbiter software. Supervisory crew command of all current functions would be retained through the use of several operating modes in the system. Both the design concept and the processes followed in defining the concept are described.

Spiger, R. J.↗

Research and Technology 1990

A brief but comprehensive review is given of the technical accomplishments of the NASA Lewis Research Center during the past year. Topics covered include instrumentation and controls technology; internal fluid dynamics; aerospace materials, structures, propulsion, and electronics; space flight systems; cryogenic fluids; Space Station Freedom systems engineering, photovoltaic power module, electrical systems, and operations; and engineering and computational support.

Source record↗

Evaluation Studies of Solid Oxide-Based Fuel Cells for Light-Weight Electrical Power in Aviation: Concepts and Opportunities for the Application of Additive Manufacturing

Currently NASA is investigating the feasibility of hybrid-electric, solid oxide fuel cell power (SOFC) systems for generating electrical power for airborne propulsion and secondary/auxiliary power. As part of this project, researchers are investigating the performance of SOFC hardware in aviation-like environments, to establish the barriers, and potential suitability, of this technology. Immediate findings indicate the unsuitability of current SOFC stack architectures with regards to ease of manufacture, specific energy, as well as environmental and mechanical durability. One possible solution is to create light-weight high specific energy density solid oxide fuel cells. The possibility may be achievable by the use of modern processing techniques such as additive manufacturing. Here I discuss the use additive manufacturing to fabricate ceramic anode, electrolytes, and cathode cells supported on various metal foams with predicted performance based upon variable porosities

Goldsby, Jon C.↗

Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Cost Optimized Technology Options to Meet Energy Needs of Food Processors

Full Paper Submission for: Combined cooling, heating and electric power (CCHP) distributed generation (DG) systems can provide electric power and, heating and cooling capability to commercial and industrial facilities directly onsite, while increasing energy efficiency, security of energy supply, grid independence and enhancing the environmental and economic situation for the site. Food processing industries often have simultaneous requirements for heat, steam, chilling and electricity making them well suited for the use of such systems to supply base-load or as peak reducing generators enabling reduction of overall energy use intensity. This paper documents analysis from a project evaluating opportunities enabled by CCHPDG for emission and cost reductions and energy storage systems installed onsite at food processing facilities. In addition, this distributed generation coupled with energy storage demonstrates a non-wires solution to delay or eliminate the need for upgrades to electric distribution systems. It was found that a dairy processing plant in the Pacific Northwest currently purchasing 15,000 MWh/yr of electricity and 190,000 MMBtu/yr of gas could be provided with a 1.1 MW CCHP system reducing the amount of electric power purchased to 450 MWh/yr while increasing the gas demand to 255,000 MMBtu/yr. The high percentage of hydro-power in this region resulted in CO2 emissions from CCHP to be higher than that attributed to the electric utility/regional energy mix. The value of this work is in documenting a real-world example demonstrating the value of CCHP to facility owners and financial decision makers to encourage them to more seriously consider CCHP systems when building or upgrading facilities.

Makhmalbaf, Atefe↗

A Review of Tribomaterial Technology for Space Nuclear Power Systems

The National Aeronautics and Space Administration (NASA) has recently proposed a nuclear closed-cycle electric power conversion system for generation of 100-kW of electrical power for space exploration missions. A critical issue is the tribological performance of sliding components within the power conversion unit that will be exposed to neutron radiation. This paper presents a review of the main considerations that have been made in the selection of solid lubricants for similar applications in the past as well as a recommendations for continuing development of the technology.

Stanford, Malcolm K.↗

Expert System Detects Power-Distribution Faults

Autonomous Power Expert (APEX) computer program is prototype expert-system program detecting faults in electrical-power-distribution system. Assists human operators in diagnosing faults and deciding what adjustments or repairs needed for immediate recovery from faults or for maintenance to correct initially nonthreatening conditions that could develop into faults. Written in Lisp.

Walters, Jerry L.↗

An efficient wireless power transfer system with security considerations for electric vehicle applications

This paper presents a secure inductive wireless power transfer (WPT) system for electric vehicle (EV) applications, such as charging the electric devices inside EVs and performing energy exchange between EVs. The key is to employ chaos theory to encrypt the wirelessly transferred energy which can then be decrypted by specific receptors in the multi-objective system. In this paper, the principle of encrypted WPT is first revealed. Then, computer simulation is conducted to validate the feasibility of the proposed system. Moreover, by comparing the WPT systems with and without encryption, the proposed energy encryption scheme does not involve noticeable power consumption.

42 ENGINEERING↗

Mission Design for the Innovative Interstellar Explorer Vision Mission

The Innovative Interstellar Explorer, studied under a NASA Vision Mission grant, examined sending a probe to a heliospheric distance of 200 Astronomical Units (AU) in a "reasonable" amount of time. Previous studies looked at the use of a near-Sun propulsive maneuver, solar sails, and fission reactor powered electric propulsion systems for propulsion. The Innovative Interstellar Explorer's mission design used a combination of a high-energy launch using current launch technology, a Jupiter gravity assist, and electric propulsion powered by advanced radioisotope power systems to reach 200 AU. Many direct and gravity assist trajectories at several power levels were considered in the development of the baseline trajectory, including single and double gravity assists utilizing the outer planets (Jupiter, Saturn, Uranus, and Neptune). A detailed spacecraft design study was completed followed by trajectory analyses to examine the performance of the spacecraft design options.

Fiehler, Douglas I.↗

Cayuga County Regional Digester: Vision Becomes Reality. Final Report

With an average herd size of 113 mature cows, Cayuga County is home to 280 dairy farms and 31,500 dairy milking cows producing approximately 855 million gallons of milk per year. The Cayuga Dairy industry is a major contributor to the countys economy, employing nearly 1200 people, while generating $140,000,000 of revenue from sale of milk alone. At the same time, the Cayuga County dairy industry also produces 5.7 million gallons of manure daily: (a) Nearly 34% of this manure is produced on smaller farms. (b) Digesters are expensive pieces of equipment and require attention and care. ( c) The on-farm digester systems have fairly long payback (>10 years) even for larger CAFO farms (>1000 milking cows). In 2005, Cayuga County Soil and Water Conservation District (The District), a Public Agency under Cayuga County, decided to undertake a centralized community digester project. The primary goal of the project was to develop an economically sustainable model, under the auspices of The District to address manure management issues facing the smaller dairies, improve the water quality and improve the quality of life for Cayuga County residents. It is believed that the District has accomplished this goal by completing construction of Cayuga County Regional Digester on a parcel of land behind the Cayuga County Natural Resource Center located at 7413 County House Road in the Town of Sennett in Cayuga County, New York. The digester facility consists of the following major components. 1. Transfer Station: This an indoor truck bay, where 35,000 gallons of manure from three local farms, 8,500 gallons of liquid organic food-processor waste, and 1,200 gallons of brown grease are unloaded from tanker trucks and the digested slurry is loaded onto the tanker trucks for delivery back to the participating farms. 2. Anaerobic Digester: The project utilizes a hydraulic mix anaerobic digester, a unique design that has no internal moving parts for mixing. The digester, which operates at mesophilic temperatures, is designed to process the daily feedstock and produce 220,000 SCF2 of biogas per day. The digester also produces 44,000 gallons of digested slurry per day. 3. Biogas Conditioning System: The plant employs a biological biogas conditioning system to remove the H2S and moisture contents of the biogas and prepare it to be used by the plant generation system. 4. Combined Heat and Power System (CHP): This is a 633kW high efficiency biogas-fired GE-Jenbacher model JMS-312 GS-NL reciprocating engine cogeneration system. The heat recovery system incorporated into the package is designed to capture the waste heat from the engine exhaust, the jacket cooling water and the engine oil circuit. 5. Electrical Substation and Power Distribution Systems: An electrical distribution system has been constructed on-site that aggregates the electrical service of the different county buildings on the District campus into a county owned electric distribution system that is interconnected with the CHP and the local electric grid. The electrical system is designed, in accordance with the utility guidelines, to allow grid-parallel operation of CHP and provide for import and export of electric power. 6. Thermal Energy Distribution System: The heat recovery system has been integrated into a high temperature water distribution system that distributes the heat to the thermal circuits for the anaerobic digester facility. Additional piping has also been installed to transfer the remaining thermal energy to other county buildings on the campus. On a daily basis, the plant will co-process 35,000 gallons of manure from local dairy farms, 8,500 gallons of food-processor waste and 1,200 gallons of brown grease to produce 200,000 ft3/d of biogas and 44,000 gallons of pathogen-free nutrient-rich digested slurry for agricultural use by farms and in the local area.The biogas fueled CHP produces 5,157,000 kWh of electricity and 19,506 dekatherms of thermal energy per year. Electrical power generated by the cogeneration system powers all the buildings on the Cayuga County campus and any surplus power is exported to the grid under a power purchase agreement. Heat recovered from the cogeneration system will be used to maintain the temperature of the process equipment and the excess will be transported to the Cayuga County Public Safety Building to offset purchase of fossil fuel to fuel the boilers. The majority of plant operations are unmanned and automated. However, the plant will have a small staff of well-trained personnel to coordinate the feedstock deliveries and shipments, supervise the day-to-day operation, monitor the systems and perform maintenance, maintain a safe and reliable operation and to respond to emergencies.

09 BIOMASS FUELS↗