Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental studies on photoabsorption by endohedral fullerene ions with a focus on Xe@C 60 + confinement resonances

A brief overview on the status of experimental investigations into photoionization and fragmentation of fullerenes and endohedral fullerenes by absorption of a single short-wavelength photon is presented. The focus of this paper is on the endohedral Xe@C 60 + molecular ion in which a xenon atom is centrally encapsulated inside a C$^{+}_{60}$ fullerene cage. Confinement resonances that result from the interference of Xe photoelectron matter waves emerging from the C$^{+}_{60}$ cavity were studied by exposing Xe@C 60 + ions to synchrotron radiation of 60 to 150 eV energy which is the region of the well-known giant atomic Xe 4d excitation resonance. Photoions Xe@C n q+ (with final charge states q = 2,3,4 of the product ions and numbers of carbon atoms left in the cage) were recorded as a function of photon energy and cross sections for the individual reaction channels were determined. In addition to previous work, new final channels (q = 2; n = 60, 58 and q = 4; n = 58, 56) were observed, and thus, about 70% of the oscillator strength expected for the encapsulated Xe atom in the investigated energy range could be recovered. The present results establish the first and, so far, only conclusive experimental observation of confinement resonances in an endohedral fullerene. The data are in remarkable agreement with relativistic R-matrix calculations that accompanied the previous experimental work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-perturbative production of fermionic dark matter from fast preheating

We investigate non-perturbative production of fermionic dark matter in the early universe. We study analytically the gravitational production mechanism accompanied by the coupling of fermions to the background inflaton field. The latter leads to the variation of effective fermion mass during preheating and makes the resulting spectrum and abundance sensitive to its parameters. Assuming fast preheating that completes in less than the inflationary Hubble time and no oscillations of the inflaton field after inflation, we find an abundant production of particles with energies ranging from the inflationary Hubble rate to the inverse duration of preheating. The produced fermions can account for all observed dark matter in a broad range of parameters. As an application of our analysis, we study non-perturbative production of fermionic dark matter in the model of Palatini Higgs inflation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Search For Electron-Antineutrinos Associated With 2 Gravitational-Wave Events GW150914, GW151012, GW151226, 3 GW170104, GW170608, GW170814, and GW170817 at Daya Bay

Providing a possible connection between neutrino emission and gravitational-wave (GW) bursts is important to our understanding of the physical processes that occur when black holes or neutron stars merge. In the Daya Bay experiment, using the data collected from December 2011 to August 2017, a search has been performed for electron-antineutrino signals coinciding with detected GW events, including GW150914, GW151012, GW151226, GW170104, GW170608, GW170814, and GW170817. We used three time windows of ±10 s, ±500 s, and ±1000 s relative to the occurrence of the GW events, and a neutrino energy range of 1.8 to 100 MeV to search for correlated neutrino candidates. The detected electron-antineutrino candidates are consistent with the expected background rates for all the three time windows. Assuming monochromatic spectra, we found upper limits (90% confidence level) on electron-antineutrino fluence of (1.13 - 2.44)×1011 cm-2 at 5 MeV to 8.0×107cm-2at 100 MeV for the three timewindows. Under the assumption of a Fermi-Dirac spectrum, the upper limits were found to be (5.4 - 7.0)×109 cm-2 for the three time windows.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of e⁺e⁻ → pp$\bar{p}\bar{n}\pi^-$ + c. c.

Using data taken at 29 center-of-mass energies between 4.16 and 4.70 GeV with the BESIII detector at the Beijing Electron Positron Collider corresponding to a total integrated luminosity of approximately 18.8 fb -1 , the process e⁺e⁻ → pp$\overline{p}\overline{n}\pi^-$ + c. c. is observed for the first time with a statistical significance of 11.5σ. The average Born cross sections in the energy ranges of (4.160, 4.380) GeV, (4.400, 4.600) GeV and (4.610, 4.700) GeV are measured to be (21.5 ± 5.7 ± 1.2) fb, (46.3 ± 10.6 ± 2.5) fb and (59.0 ± 9.4 ± 3.2) fb, respectively, where the first uncertainties are statistical and the second are systematic. The line shapes of the $\overline{p}\overline{n}$ and ppπ⁻ invariant mass spectra are consistent with phase space distributions, indicating that no hexaquark or di-baryon state is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50 μm, 100 μm, and 150 μm were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR), and energy linearity is an important property for particle ID capabilities.

Particle tracking detectors↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

Urca nuclide production in Type-I X-ray bursts and implications for nuclear physics studies

ABSTRACT The thermal structure of accreting neutron stars is affected by the presence of urca nuclei in the neutron star crust. Nuclear isobars harbouring urca nuclides can be produced in the ashes of Type I X-ray bursts, but the details of their production have not yet been explored. Using the code MESA, we investigate urca nuclide production in a one-dimensional model of Type I X-ray bursts using astrophysical conditions thought to resemble the source GS 1826-24. We find that high-mass (A ≥ 55) urca nuclei are primarily produced late in the X-ray burst, during hydrogen-burning freeze-out that corresponds to the tail of the burst light curve. The ∼0.4–0.6 GK temperature relevant for the nucleosynthesis of these urca nuclides is much lower than the ∼1 GK temperature most relevant for X-ray burst light curve impacts by nuclear reaction rates involving high-mass nuclides. The latter temperature is often assumed for nuclear physics studies. Therefore, our findings alter the excitation energy range of interest in compound nuclei for nuclear physics studies of urca nuclide production. We demonstrate that for some cases this will need to be considered in planning for nuclear physics experiments. Additionally, we show that the lower temperature range for urca nuclide production explains why variations of some nuclear reaction rates in model calculations impacts the burst light curve but not local features of the burst ashes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiwavelength study of OT 081: broadband modelling of a transitional blazar

ABSTRACT OT 081 is a well-known, luminous blazar that is remarkably variable in many energy bands. We present the first broadband study of the source, which includes very high energy (VHE, $E\gt $ 100 GeV) $\gamma$-ray data taken by the MAGIC (Major Atmospheric Gamma-ray Imaging Cherenkov telescopes) and H.E.S.S. (High Energy Stereoscopic System) imaging Cherenkov telescopes. The discovery of VHE $\gamma$-ray emission happened during a high state of $\gamma$-ray activity in July 2016, observed by many instruments from radio to VHE $\gamma$-rays. We identify four states of activity of the source, one of which includes VHE $\gamma$-ray emission. Variability in the VHE domain is found on daily time-scales. The intrinsic VHE spectrum can be described by a power law with index $3.27\pm 0.44_{\rm stat}\pm 0.15_{\rm sys}$ (MAGIC) and $3.39\pm 0.58_{\rm stat}\pm 0.64_{\rm sys}$ (H.E.S.S.) in the energy range of 55–300 and 120–500 GeV, respectively. The broadband emission cannot be successfully reproduced by a simple one-zone synchrotron self-Compton model. Instead, an additional external Compton component is required. We test a lepto-hadronic model that reproduces the data set well and a proton-synchrotron-dominated model that requires an extreme proton luminosity. Emission models that are able to successfully represent the data place the emitting region well outside of the broad-line region to a location at which the radiative environment is dominated by the infrared thermal radiation field of the dusty torus. In the scenario described by this flaring activity, the source appears to be a flat spectrum radio quasar (FSRQ), in contrast with past categorizations. This suggests that the source can be considered to be a transitional blazar, intermediate between BL Lac and FSRQ objects.

Abe, H.↗

Evidence for a Spectral Break or Curvature in the Spectrum of Astrophysical Neutrinos from 5 TeV to 10 PeV

Here, we report improved measurements of the all flavor astrophysical neutrino spectrum with IceCube by combining complementary neutrino samples in two independent analyses. Both analyses show evidence of a harder spectrum at energies below ∼ 30 TeV compared to higher energies where the spectrum is well characterized by a power law. The spectrum is better described by a log parabola or a broken power law, the latter being the preferred model. Both, however, reject a single power law over an energy range 5 TeV–10 PeV with a significance > 4⁢𝜎, providing new constraints on properties of cosmic neutrino sources.

Abbasi, R. [Loyola University Chicago] (ORCID:0000↗

Measurement of single- and double-polarization observables in the photoproduction of 𝜋 + ⁢𝜋 − meson pairs off the proton using CLAS at Jefferson Laboratory

The photoproduction of 𝜋 + ⁢𝜋 − meson pairs off the proton has been studied in the reaction 𝛾⁢𝑝→𝑝⁢𝜋 + ⁢𝜋 − using the CEBAF Large Acceptance Spectrometer (CLAS) and the frozen-spin target (FROST) in Hall B at the Thomas Jefferson National Accelerator Facility. For the first time, the beam and target asymmetries, 𝐼 𝑠,𝑐 and 𝑃 𝑥,𝑦 , have been measured along with the beam-target double-polarization observables, 𝑃$^{𝑠,𝑐}_{𝑥,𝑦}$, using a transversely polarized target with center-of-mass energies ranging from 1.51 GeV up to 2.04 GeV. These data and additional 𝜋⁢𝜋 photoproduction observables from CLAS and experiments elsewhere were included in a partial-wave analysis within the Bonn-Gatchina framework. Significant contributions from 𝑠-channel resonance production are observed in addition to 𝑡-channel exchange processes. The data indicate significant contributions from 𝑁* and Δ* resonances in the third and fourth resonance regions.

QCD phenomenology↗

182 W (𝑛,2⁢𝑛)⁢ 181 W cross-section data from threshold to 15 MeV

Measurements of the 182 W(n, 2n) 181 W cross section have been performed in the neutron energy range between 8 and 15 MeV using the activation technique. Such data are needed to help interpret results of laser shots at the National Ignition Facility using a new DT capsule design, featuring a high-Z inner shell, with tungsten as the favored material, and an outer shell made of a low-Z material. Our data are in very good agreement with the previous data of Frehaut et al., which are based on a different technique, and in fair agreement with the ENDF/B-VIII.0 and the JEFF-3.3 evaluations.

150 ≤ A ≤ 189↗