Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRONIC MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Pulsed Electron Paramagnetic Resonance Insights into the Ligand Environment of Copper in Drosophila Lysyl Oxidase

Lysyl oxidase (LOX) is a copper amine oxidase that cross-links collagens and elastin in connective tissue and plays an important role in fibrosis, cancer development, and formation of the “metastatic niche”. Despite its important biological functions, the structure of human LOX remains unknown (unlike that of an unrelated LOX, from Pichia pastoris ). In this study, we expressed active LOX from Drosophila melanogaster , DmLOXL1, a close homologue of human LOX, and characterized it by MS, UV–vis, activity, and inhibition assays. We then used bioinformatics, electron paramagnetic resonance, electron spin-echo envelope modulation, and hyperfine sublevel-correlation (HYSCORE) spectroscopies to probe Cu-ligand bonding finding direct evidence for pH-dependent Cu–His interactions. At pH = 9.3, the spectroscopic data indicated primarily a single His bound to Cu, but at pH = 7.5, there was evidence for a ~ 1:1 mixture of species containing 1 and 3 His ligands. We then used HYSCORE to probe possible interactions between the LOX inhibitor BAPN (β-aminopropionitrile; 1-[ 13 C 15 N]cyano-2-aminoethane) and the copper center—finding none. Overall, the results are of interest since they provide new spectroscopic information about the nature of the catalytic site in LOX, an important anticancer drug target.

,Ligands↗

Use of tear ring permits repair of sealed module circuitry

Improved packaging technique for modular electronic circuitry utilizes a tear ring which may be removed for repair and resealed. The tear ring is put over the container and header to which the electronic circuit assembly has been attached.

Source record↗

A detector for high frequency modulation in auroral particle fluxes

A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

Spiger, R. J.↗

Broadband Ultrafast Dynamics of Refractory Metals: TiN and ZrN

Transition metal nitrides have recently gained attention in the fields of plasmonics, plasmon-enhanced photocatalysis, photothermal applications, and nonlinear optics because of their suitable optical properties, refractory nature, and large laser damage thresholds. Here we report comparative studies of the transient response of films of titanium nitride (TiN), zirconium nitride (ZrN), and gold (Au) under femtosecond excitation. Broadband transient optical characterization helps to adjudicate earlier, somewhat inconsistent reports regarding hot electron lifetimes based upon single wavelength measurements. These pump–probe experiments show sub-picosecond transient dynamics only within the epsilon-near-zero window of the refractory metals. The dynamics are dominated by photoinduced interband transitions resulting from ultrafast electron energy redistribution. The enhanced reflection modulation in the epsilon-near-zero window makes it possible to observe the ultrafast optical response of these films at low pump fluences. These results indicate that electron–phonon coupling in TiN and ZrN is 25–100 times greater than in Au. Strong electron–phonon coupling drives the sub-picosecond optical response and facilitates greater lattice heating compared to Au, making TiN and ZrN promising for photothermal applications. The spectral response and dynamics of TiN and ZrN are only weakly sensitive to pump fluence and pump excitation energy. However, the magnitude of the response is much greater at higher pump photon energies and higher fluences, reaching peak observed values of 15% in TiN and 50% in ZrN in the epsilon-near-zero window.

36 MATERIALS SCIENCE↗

Electronic- and band-structure evolution in low-doped (Ga,Mn)As

Modulation photoreflectance spectroscopy and Raman spectroscopy have been applied to study the electronic- and band-structure evolution in (Ga,Mn)As epitaxial layers with increasing Mn doping in the range of low Mn content, up to 1.2%. Structural and magnetic properties of the layers were characterized with high-resolution X-ray diffractometry and SQUID magnetometery, respectively. The revealed results of decrease in the band-gap-transition energy with increasing Mn content in very low-doped (Ga,Mn)As layers with n-type conductivity are interpreted as a result of merging the Mn-related impurity band with the host GaAs valence band. On the other hand, an increase in the band-gap-transition energy with increasing Mn content in (Ga,Mn)As layers with higher Mn content and p-type conductivity indicates the Moss-Burstein shift of the absorption edge due to the Fermi level location within the valence band, determined by the free-hole concentration. The experimental results are consistent with the valence-band origin of mobile holes mediating ferromagnetic ordering in the (Ga,Mn)As diluted ferromagnetic semiconductor.

36 MATERIALS SCIENCE↗

VLF wave emissions by pulsed and dc electron beams in space. I - Spacelab 2 observations

The properties of radio waves generated by electron beams in space were investigated using data from the wideband wave receiver on the Spacelab 2. The VLF observations were found to confirm the results of the STS 3/OSS-1 mission. It was found that a 1-keV electron beam injected from the orbiter produced copious broadband electromagnetic emissions. When the electron beam was square-wave modulated, narrow-band emissions at the pulsing frequency and harmonics of that frequency were produced along with the broadband emissions. The observations indicated that dc 50-mA electron beams and pulsed 50-percent duty-cycle 100-mA beams produce broadband radiation which is comparable in intensity and spectral shape at all points for which the wave field was sampled.

Reeves, G. D.↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP↗

Jovian electrons at 1 AU - 1978-1984

Data on Jovian electrons sensed with a spectrometer on board the ISEE spacecraft at 1 AU are studied in terms of intensity variations over time and shape and variations of the electron spectra with time. Design and performance features of the electron spectrometer are described. The analyses cover solar cycle modulation of intensity, the synodic intensity modulation, micromodulation over a period of days, and adiabatic deceleration of electrons propagating in the expanding solar wind. Emphasis is placed on the effects of maximum solar activity on Jovian electron emission and propagation, noting a confirmed 13 mos intensity variation in the Jovian electrons.

Moses, Dan↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Electron Ghost Imaging

Here in this paper, we report a demonstration of electron ghost imaging. A digital micromirror device directly modulates the photocathode drive laser to control the transverse distribution of a relativistic electron beam incident on a sample. Correlating the structured illumination pattern to the total sample transmission then retrieves the target image, avoiding the need for a pixelated detector. In our example, we use a compressed sensing framework to improve the reconstruction quality and reduce the number of shots compared to raster scanning a small beam across the target. Finally, compressed electron ghost imaging can reduce both acquisition time and sample damage in experiments for which spatially resolved detectors are unavailable (e.g., spectroscopy) or in which the experimental architecture precludes full frame direct imaging.

43 PARTICLE ACCELERATORS↗

Density fluctuations due to Raman forward scattering in quantum plasma

Density fluctuations due Raman forward scattering (RFS) is analysed in the interaction of a high intensity laser pulse with high density quantum plasma. The interaction model is developed using the quantum hydrodynamic (QHD) model which consist of a set of equations describing the transport of charge, density, momentum and energy of a charged particle system interacting through a self-consistent electrostatic potential. The nonlinear source current has been obtained incorporating the effects of quantum Bohm potential, Fermi pressure and electron spin. The laser spectrum is strongly modulated by the interaction, showing sidebands at the plasma frequency. Furthermore, as the quiver velocity of the electrons in the high electric field of the laser beam is quit large, various quantum effects are observed which can be attributed to the variation of electron mass with laser intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intersection-Controller Software Module

An important part of the emergency-vehicle traffic-light-preemption system summarized in the preceding article is a software module executed by a microcontroller in each intersection controller. This module monitors the broadcasts from all nearby participating emergency vehicles and intersections. It gathers the broadcast data pertaining to the positions and velocities of the vehicles and the timing of traffic and pedestrian lights and processes the data into predictions of the future positions of the vehicles. Analyzing the predictions by a combination of proximity tests, map-matching techniques, and statistical calculations designed to minimize the adverse effects of uncertainties in vehicle positions and headings, the module decides whether to preempt and issues the appropriate commands to the traffic lights, pedestrian lights, and electronic warning signs at the intersection. The module also broadcasts its state to all nearby vehicles and intersections. The module is designed to mitigate the effects of missing data and of unpredictable delays in the system. It has been intensively tested and refined so that it fails to warn in very few cases and issues very few false warnings.

Bachelder, Aaron↗

Asymmetric electroresistance of cluster glass state in manganites

We report the electrostatic modulation of transport in strained Pr{sub 0.65}(Ca{sub 0.75}Sr{sub 0.25}){sub 0.35}MnO{sub 3} thin films grown on SrTiO{sub 3} by gating with ionic liquid in electric double layer transistors (EDLT). In such manganite films with strong phase separation, a cluster glass magnetic state emerges at low temperatures with a spin freezing temperature of about 99 K, which is accompanied by the reentrant insulating state with high resistance below 30 K. In the EDLT, we observe bipolar and asymmetric modulation of the channel resistance, as well as an enhanced electroresistance up to 200% at positive gate bias. Our results provide insights on the carrier-density-dependent correlated electron physics of cluster glass systems.

36 MATERIALS SCIENCE↗

Wide Band-Gap Semiconductor Based Power Electronics for Energy Efficiency

Recent advances in wide band-gap (WBG) semiconductor materials, such as silicon carbide (SiC) and gallium nitride (GaN) are enabling a new generation of power semiconductor devices that far exceed the performance of silicon-based devices. Past ARPA-E programs (ADEPT, Solar ADEPT, and SWITCHES) have enabled innovations throughout the power electronics value chain, especially in the area of WBG semiconductors. The two recently launched programs by ARPA-E (CIRCUITS and PNDIODES) continue to investigate the use of WBG semiconductors in power electronics. From materials and devices to modules and circuits to application-ready systems integration, ARPA-E projects have demonstrated the potential of WBG semiconductors to lower the cost of high-efficiency power electronics to enable broad adoption in energy applications.

25 ENERGY STORAGE↗

Coastal Changes in Temperature and Salinity Observed during Hurricane Isaac Recorded and Downloaded by NASA DRIFTERs Moored in Heron Bay and at Half Moon Island, Louisiana

Major changes in salinity (approx.14 ppt.) and temperature (approx.40C) were continuously registered by two prototype NASA DRIFTERs, surface moored floaters, that NASA's Applied Science and Technology Project Office (ASTPO) has developed. The DRIFTER floating sensor module is equipped with an Arduino open-source electronics prototyping platform and programming language (http://www.arduino.cc), a GPS (Global Positioning System) module with antenna, a cell phone SIM (Subscriber Identity Module) card and a cellular antenna which is used to transmit data, and a probe to measure temperature and conductivity (from which salinity can be derived). The DRIFTER is powered by a solar cell panel and all the electronic components are mounted and sealed in [ waterproof encasement. Position and measurement data are transmitted via short message service (SMS) messaging to a Twitter site (DRIFTER 002@NASADRIFTER_002 and DRIFTER 004@NASADRIFTER_004), which provides a live feed. These data are the imported into a Google spreadsheet where conductivity is converted to salinity, and graphed in real-time. The spreadsheet data will be imported into a webpage maintained by ASTPO, where it will be displayed available for dO\\1lload.

Kalcic, Maria↗

Mapping Conductance and Switching Behavior of Graphene Devices In Situ

Graphene is proposed for use in various nanodevice designs, many of which harness emergent quantum properties for device functionality. However, visualization, measurement, and manipulation become nontrivial at nanometer and atomic scales, representing a significant challenge for device fabrication, characterization, and optimization at length scales where quantum effects emerge. Herein, proof of principle results at the crossroads between 2D nanoelectronic devices, e-beam-induced modulation, and imaging with secondary electron e-beam induced currents (SEEBIC) is presented. A device platform compatible with scanning transmission electron microscopy investigations is introduced. Then how the SEEBIC imaging technique can be used to visualize conductance and connectivity in single layer graphene nanodevices, even while supported on a thicker substrate (conditions under which conventional imaging fails) is shown. Finally, it is shown that the SEEBIC imaging technique can detect subtle differences in charge transport through time in nonohmic graphene nanoconstrictions indicating the potential to reveal dynamic electronic processes.

36 MATERIALS SCIENCE↗

Flattening Filter Free vs Flattened Beams for Breast Irradiation

Purpose: Flattening filter free (FFF) beams offer the potential for a higher dose rate, shorter treatment time, and lower peripheral dose. To investigate their role in large-field treatments, this study compared flattened and FFF beams for breast irradiation. Methods and Materials: Ten left breast clinical plans comprising 2 tangential beams and a medially located 3-field simultaneous integrated boost (SIB) were replanned. Full intensity modulated radiotherapy (IMRT), hybrid IMRT, electronic tissue compensator (ETC), and multiple static field treatment plans were created for the elective breast volume using flattened and FFF beams, in combination with a 3-field IMRT SIB. Plan quality was assessed and delivery times were measured for all plans for 1 patient. Out-of-field doses were measured using an ionization chamber for an IMRT plan optimized on a corner of simple cubic phantom for both flattened and FFF beams. Results: For each technique, mean target volume metrics (planning target volume coverage, homogeneity, conformity) were typically within 3% for flattened and FFF beams. Larger mean differences in boost conformity favoring flattened hybrid (7.2%) and full IMRT (5.5%) plans may have reflected limitations in plan normalization. Calculated heart and ipsilateral lung doses were comparable; however, both flattened and FFF low-dose phantom measurements were substantially higher than calculated values, rendering the comparison of low dose in the contralateral breast uncertain. Beam delivery times were on average 31% less for FFF. Conclusions: In general, target volume metrics for flattened and FFF plans were comparable. The planning system did not seem to allow for accurate peripheral dose evaluation. FFF was associated with a potentially shorter treatment time. All 4 IMRT techniques allowed FFF beams to generate acceptable plans for breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗