Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

First Results from Laser-Based Spectral Characterization of Landsat 9 Operational Land Imager-2

Landsat 9 will continue the Landsat data record into its fifth decade with launch scheduled for December 2020. The two instruments on Landsat 9 are Thermal Infrared Sensor-2 (TIRS-2) and Operational Land Imager-2 (OLI-2). OLI-2 is a nine-channel pushbroom imager with a 15-degree field of view that will have a 16-day measurement cadence from its nominal 705-km orbit altitude. A key aspect of the data that will be produced by OLI-2 is its spectral fidelity which enables countless science applications. The prelaunch test campaign for spectral characterization of OLI-2 was substantially improved relative to the methodology used for OLI: the full spectral response of every detector was characterized with greater accuracy, sampling, and precision. This paper will describe how this was accomplished with a tunable laser-based light source called Goddard Laser for Absolute Measurement of Radiance (GLAMR).

tunable laser↗

RadLab: A Comprehensive Database and Analysis Toolkit for Space Radiation Measurements Relevant to Space Radiation Biology

RadLab, a new addition to the NASA Open Science Data Repository (OSDR), is a public platform for space radiation data relevant to human space exploration. RadLab consists of a database, a submission portal, and user-friendly visualization and data analysis tools, including a graphical user interface (GUI) and an application programming interface (API). Investigators from ISS partners including Germany, Italy, Canada, Hungary, the Czech Republic, Russia, Japan have committed to providing data from their instruments. RadLab will also include data from other spacecraft in LEO: the Space Shuttle, the Mir space station, biosatellites; and beyond LEO: the lunar and the Martian surface, the heliocentric orbit at 1 AU, Mars orbit, and Earth-Mars space. Once fully operational, RadLab will provide open, centralized access to space radiation physics data relevant to human space exploration; a platform for submission of data by agencies and research institutions responsible for radiation detectors deployed in space; analysis tools to facilitate detector and dataset intercomparison to better understand space habitat radiation environments; capabilities for space biology investigators to determine the radiation environment to which samples were exposed. A RadLab Working Group (RLWG) has been formed, modeled on the GeneLab Analysis Working Groups and comprised of data contributors and users. RLWG tasks include identifying data sources, normalizing data from diverse detectors, expanding the analysis toolkit and, perhaps most importantly, sharing ideas for research exploiting capabilities of RadLab. We will provide an overview of RadLab data and capabilities and discuss examples of its potential as a resource for open science.

radiation↗

Simulations of the LHC high luminosity monitors at beam energies from 3.5 TeV to 7.0 TeV

We have constructed two pairs of fast ionization chambers (BRAN) for measurement and optimization of luminosity at IR1 and IR5 of the LHC. These devices are capable of monitoring the performance of the LHC at low luminosity 10{sup 28} cm{sup -2}s{sup -1} during beam commissioning all the way up to the expected full luminosity of 10{sup 34} cm{sup -2}s{sup -1} at 7.0 TeV. The ionization chambers measure the intensity of hadronic/electromagnetic showers produced by the forward neutral particles of LHC collisions. To predict and improve the understanding of the BRAN performance, we created a detailed FLUKA model of the detector and its surroundings. In this paper, we describe the model and the results of our simulations including the detector's estimated response to pp collisions at beam energies of 3.5, 5.0, and 7.0 TeV per beam. In addition, these simulations show the sensitivity of the BRAN to the crossing angle of the two LHC beams. It is shown that the BRAN sensitivity to the crossing angle is proportional to the measurement of crossing angle by the LHC beam position monitors.

43 PARTICLE ACCELERATORS↗

Peak Prediction Using Multi Layer Perceptron (MLP) for Edge Computing ASICs Targeting Scientific Applications

High data rate detectors play an integral part in scientific research and their development is actively pursued at High Energy Physics (HEP) facilities around the world. Edge Machine Learning (ML) offers the ability to reduce data rates by integrating ML algorithms into Application Specific Integrated Circuits (ASICs) on the front end electronics. In this work, we explore a set of neural network architectures for predicting the peak amplitudes in the detector's sensor response. We have designed and synthesized several MLP based neural networks comparing their inference accuracy, power consumption, and area targeting for minimal latency. The neural networks are synthesized in a commercial 65nm process. The effect of quantizing the network's weights and biases on hardware performance and area is reported. We also conduct design space exploration to compare between design alternatives

47 OTHER INSTRUMENTATION↗

Improving the nuclear data base for non-proliferation and homeland security

Many of the technical advances in non-proliferation and homeland security require calculations of transport of neutrons and gamma-rays through materials. The nuclear data base on which these calculations are made must be of high quality in order for the calculated responses to be credible. At the Los Alamos Neutron Science Center, three spallation neutron sources are being used to provide high-quality cross section and structure data with reactions induced by neutrons. Neutron transmission, neutron-induced fission and capture cross sections, neutron emission in fission, and gamma-ray production by neutrons are principal areas of research. Furthermore, these sources are also being used to validate calculations of the characterization and response of new detectors and detection techniques. Current research activities are summarized here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Structure of Particle Production in the MERIT High-Power Target Experiment

The MERIT experiment is a proof-of-principle test of a target system for high power proton beam to be used as front-end for a neutrino factory complex or amuon collider. The experiment took data in autumn 2007 with the fast extracted beam from the CERN Proton Synchrotron (PS) to a maximum intensity of about 30 x 10{sup 12} protons per pulse. We report results from the portion of the MERIT experiment in which separated beam pulses were delivered to a free mercury jet target with time intervals between pulses varying from 2 to 700 {micro}s. The analysis is based on the responses of particle detectors placed along side and downstream of the target.

43 PARTICLE ACCELERATORS↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗

Search for muon neutrino disappearance with multi-topologically splitted Inclusive events at SBN

The Short-Baseline Neutrino (SBN) program at Fermilab searches for signatures of sterile neutrinos with mass-squared splittings at the O(1) eV2 scale, motivated by anomalies previously reported by the LSND and MiniBooNE experiments. We present a search for such signatures using the muon neutrino disappearance channel. This analysis exploits the large statistics of fully inclusive charged-current interactions collected by the SBND and ICARUS detectors to maximize sensitivity. The inclusive samples in both detectors are further subdivided into multiple exclusive topological channels, a strategy designed to enhance sensitivity by isolating differences in interaction-mode composition and reconstructed energy response. This multi-topology approach represents a novel analysis technique within SBN, enabling improved constraints on systematic uncertainties arising from neutrino flux, interaction modeling, and detector response. We will present comparisons of data with detailed predictions incorporating a comprehensive treatment of systematic uncertainties and constraints on the systematics obtained by the multi-topology method.

Yadav, Shweta [Texas U., Arlington]↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗

Development of a Detector Model for Generation of Synthetic Radiographs of Cargo Containers

Creation of synthetic cargo-container radiographs that possess attributes of their empirical counterparts requires accurate models of the imaging system response. Synthetic radiographs serve as surrogate data in studies aimed at determining system effectiveness for detecting target objects when it is impractical to collect a large set of empirical radiographs. In the case where a detailed understanding of the detector system is available, an accurate detector model can be derived from first principles. In the absence of this detail, it is necessary to derive empirical models of the imaging-system response from radiographs of well-characterized objects. Such a case is the topic of this work, where we demonstrate the development of an empirical model of a gamma-ray radiography system with the intent of creating a detector-response model that translates uncollided photon transport calculations into realistic synthetic radiographs. The detector-response model is calibrated to field measurements of well-characterized objects thus incorporating properties such as system sensitivity, spatial resolution, contrast, and noise.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

Modeling of Diamond Based Devices for Beam Diagnostics

Beamlines at new light sources, such as the National Synchrotron Light Source II will operate at flux levels beyond the saturation level of existing diagnostics, necessitating the development of new devices. Currently, there is no detector which can span the entire flux range that is possible even in a second generation light source and will become crucial for next generation light sources. One new approach is a diamond-based detector that will be able to monitor beam position, flux and timing to much better resolution. Furthermore, this detector also has linear response to flux over 11 orders of magnitude. However, the successful development of the detector requires thorough understanding and optimization of the physical processes involved. We will discuss the new modeling capabilities we have been implementing in the VORPAL 3D code to investigate the effects of charge generation due to absorption of x-ray photons, transport, and charge trapping. We will report results from VORPAL simulations on charge collection and how it depends on applied field, charge trapping, and the energy of absorbed photons.

43 PARTICLE ACCELERATORS↗

Equivalence of optical and electrical noise equivalent power of hybrid NbTiN-Al microwave kinetic inductance detectors

We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical noise equivalent power (NEP) from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature, and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail, the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗