Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISPLACED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pyrochlore formation, phase relations, and properties in the CaO-TiO{sub 2}-(Nb,Ta){sub 2}O{sub 5} systems

Phase equilibria studies of the CaO:TiO{sub 2}:Nb{sub 2}O{sub 5} system confirmed the formation of six ternary phases: pyrochlore (A{sub 2}B{sub 2}O{sub 6}O'), and five members of the (110) perovskite-slab series Ca{sub n}(Ti,Nb){sub n}O{sub 3n+2}, with n=4.5, 5, 6, 7, and 8. Relations in the quasibinary Ca{sub 2}Nb{sub 2}O{sub 7}-CaTiO{sub 3} system, which contains the Ca{sub n}(Ti,Nb){sub n}O{sub 3n+2} phases, were determined in detail. CaTiO{sub 3} forms solid solutions with Ca{sub 2}Nb{sub 2}O{sub 7} as well as CaNb{sub 2}O{sub 6}, resulting in a triangular single-phase perovskite region with corners CaTiO{sub 3}-70Ca{sub 2}Ti{sub 2}O{sub 6}:30Ca{sub 2}Nb{sub 2}O{sub 7}-80CaTiO{sub 3}:20CaNb{sub 2}O{sub 6}. A pyrochlore solid solution forms approximately along a line from 42.7:42.7:14.6 to 42.2:40.8:17.0 CaO:TiO{sub 2}:Nb{sub 2}O{sub 5}, suggesting formulas ranging from Ca{sub 1.48}Ti{sub 1.48}Nb{sub 1.02}O{sub 7} to Ca{sub 1.41}Ti{sub 1.37}Nb{sub 1.14}O{sub 7} (assuming filled oxygen sites), respectively. Several compositions in the CaO:TiO{sub 2}:Ta{sub 2}O{sub 5} system were equilibrated to check its similarity to the niobia system in the pyrochlore region, which was confirmed. Structural refinements of the pyrochlores Ca{sub 1.46}Ti{sub 1.38}Nb{sub 1.11}O{sub 7} and Ca{sub 1.51}Ti{sub 1.32}V{sub 0.04}Ta{sub 1.10}O{sub 7} using single-crystal X-ray diffraction data are reported (Fd3m (no. 227), a=10.2301(2) A (Nb), a=10.2383(2) A (Ta)), with Ti mixing on the A-type Ca sites as well as the octahedral B-type sites. Identical displacive disorder was found for the niobate and tantalate pyrochlores: Ca occupies the ideal 16d position, but Ti is displaced 0.7 A to partially occupy a ring of six 96g sites, thereby reducing its coordination number from eight to five (distorted trigonal bipyramidal). The O' oxygens in both pyrochlores were displaced 0.48 A from the ideal 8b position to a tetrahedral cluster of 32e sites. The refinement results also suggested that some of the Ti in the A-type positions may occupy distorted tetrahedra, as observed in some zirconolite-type phases. The Ca-Ti-(Nb,Ta)-O pyrochlores both exhibited dielectric relaxation similar to that observed for some Bi-containing pyrochlores, which also exhibit displacively disordered crystal structures. Observation of dielectric relaxation in the Ca-Ti-(Nb,Ta)-O pyrochlores suggests that it arises from the displacive disorder and not from the presence of polarizable lone-pair cations such as Bi{sup 3+}. - Graphical abstract: Crystal structures of the pyrochlores Ca{sub 1.46}Ti{sub 1.38}Nb{sub 1.11}O{sub 7} and Ca{sub 1.51}Ti{sub 1.32}V{sub 0.04}Ta{sub 1.10}O{sub 7} were refined using single-crystal X-ray diffraction data. Both Ca{sup 2+} and Ti{sup 4+} occupy the A-type sites; Ca occupies the ideal 16d site and Ti is displaced 0.7 A to partially occupy a ring of six 96g sites. The O' oxygens are disordered among a tetrahedral cluster of 32e sites displaced 0.48 A from the ideal 8b site. Both pyrochlores display dielectric relaxation similar to that observed for analogous Bi-based systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE ABUNDANCE OF BULLET GROUPS IN ΛCDM

We estimate the expected distribution of displacements between the two dominant dark matter (DM) peaks (DM-DM displacements) and between the DM and gaseous baryon peak (DM-gas displacements) in DM halos with masses larger than 10{sup 13} h {sup –1} M {sub ☉}. As a benchmark, we use the observation of SL2S J08544–0121, which is the lowest mass system (1.0 × 10{sup 14} h {sup –1} M {sub ☉}) observed so far, featuring a bi-modal DM distribution with a dislocated gas component. We find that (50 ± 10)% of the DM halos with circular velocities in the range 300-700 km s{sup –1} (groups) show DM-DM displacements equal to or larger than 186 ± 30 h {sup –1} kpc as observed in SL2S J08544–0121. For DM halos with circular velocities larger than 700 km s{sup –1} (clusters) this fraction rises to (70 ± 10)%. Using the same simulation, we estimate the DM-gas displacements and find that 0.1%-1.0% of the groups should present separations equal to or larger than 87 ± 14 h {sup –1} kpc, corresponding to our observational benchmark; for clusters, this fraction rises to (7 ± 3)%, consistent with previous studies of DM to baryon separations. Considering both constraints on the DM-DM and DM-gas displacements, we find that the number density of groups similar to SL2S J08544–0121 is ∼6.0 × 10{sup –7} Mpc{sup –3}, three times larger than the estimated value for clusters. These results open up the possibility for a new statistical test of ΛCDM by looking for DM-gas displacements in low mass clusters and groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Radiation Effects in Custom-and Commercially-Fabricated Resistive Memory Devices

The radiation response of TaO x -based RRAM devices fabricated in academic (Set A) and industrial (Set B) settings was compared. Ionization damage from a 60 Co gamma source did not cause any changes in device resistance for either device type, up to 45 Mrad(Si). Displacement damage from a heavy ion beam caused the Set B in the high resistance state to decrease in resistance at 1 x 10 21 oxygen displacements per cm 3 ; meanwhile, the Set A devices did not exhibit any decrease in resistance due to displacement damage. Both types of devices exhibited an increase in resistance around 3 x 10 22 oxygen displacements per cm 3 , possibly due to damage at the oxide/metal interfaces. These extremely high levels of damage represent near-total atomic disruption, and if this level of damage were ever reached, other circuit elements would likely fail before the RRAM devices in this study. Overall, both sets of devices were much more resistant to radiation effects than other devices reported in the literature. Displacement damage effects were only observed in the Set A devices once the displacement-induced oxygen vacancies surpassed the intrinsic vacancy concentration in the devices, suggesting that high oxygen vacancy concentration played a role in the devices’ high tolerance to displacement damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-603: Analysis of Optical Tracked Head Inter-Fraction Movements Within Masks to Access Intracranial Immobilization Techniques in Proton Therapy

Purpose: We present a quantitative methodology utilizing an optical tracking system for monitoring head inter-fraction movements within brain masks to assess the effectiveness of two intracranial immobilization techniques. Methods and Materials: A 3-point-tracking method was developed to measure the mask location for a treatment field at each fraction. Measured displacement of mask location to its location at first fraction is equivalent to the head movement within the mask. Head movements for each of treatment fields were measured over about 10 fractions at each patient for seven patients; five treated in supine and two treated in prone. The Q-fix Base-of-Skull head frame was used in supine while the CIVCO uni-frame baseplate was used in prone. Displacements of recoded couch position of each field post imaging at each fraction were extracted for those seven patients. Standard deviation (S.D.) of head movements and couch displacements was scored for statistical analysis. Results: The accuracy of 3PtTrack method was within 1.0 mm by phantom measurements. Patterns of head movement and couch displacement were similar for patients treated in either supine or prone. In superior-inferior direction, mean value of scored standard deviations over seven patients were 1.6 mm and 3.4 mm for the head movement and the couch displacement, respectively. The result indicated that the head movement combined with a loose fixation between the mask-to-head frame results large couch displacements for each patient, and also large variation between patients. However, the head movement is the main cause for the couch displacement with similar magnitude of around 1.0 mm in anterior-posterior and lateral directions. Conclusions: Optical-tracking methodology independently quantifying head movements could improve immobilization devices by correctly acting on causes for head motions within mask. A confidence in the quality of intracranial immobilization techniques could be more efficient by eliminating the need for frequent imaging.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Brachytherapy 02: Positional accuracy in Pd-103 permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC)

Purpose: This retrospective study aims to quantify the positional accuracy of seed delivery in permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC). Methods: Treatment planning and post-implant CT scans for 5 patients were rigidly registered using the MIM Symphony™ software (MIM Software, Cleveland, OH) and used to evaluate differences between planned and implanted seed positions. Total and directional seed displacements were calculated for each patient in a clinically relevant ‘needle coordinate system’, defined relative to the angle of fiducial needle insertion. Results: The overall average total seed displacement was 10±8 mm. Systematic seed displacements were observed in individual patients and the magnitude and direction of these offsets varied among patients. One patient showed a significant directional seed displacement in the shallow-deep direction compared with the other four patients. With the exception of this one patient outlier, no significant systematic directional displacements in the needle coordinate system were observed for this cohort; the average directional displacements were −1±5 mm, 2±3 mm, and −2±4 mm in the shallow-deep, up-down, and right-left directions respectively. Conclusion: With the exception of one patient outlier, the magnitude of seed displacements were relatively consistent among patients. The results indicate that the shallow-deep direction possesses the largest uncertainty for the seed delivery method used at the TBCC. The relatively large uncertainty in seed placement in this direction is expected, as this is the direction of needle insertion. Further work will involve evaluating deflections of delivered needle tracks from their planned positions.

60 APPLIED LIFE SCIENCES↗

Thermomechanical characterization of a membrane deformable mirror

A membrane deformable mirror has been investigated for its potential use in high-energy laser systems. Experiments were performed in which the deformable mirror was heated with a 1 kW incandescent lamp and the thermal profile, the wavefront aberrations, and the mechanical displacement of the membrane were measured. A finite element model was also developed. The wavefront characterization experiments showed that the wavefront degraded with heating. Above a temperature of 35 deg. C, the wavefront characterization experiments indicated a dramatic increase in the high-order wavefront modes before the optical beam became immeasurable in the sensors. The mechanical displacement data of the membrane mirror showed that during heating, the membrane initially deflected towards the heat source and then deflected away from the heat source. Finite element analysis (FEA) predicted a similar displacement behavior as shown by the mechanical displacement data but over a shorter time scale and a larger magnitude. The mechanical displacement data also showed that the magnitude of membrane displacement increased with the experiments that involved higher temperatures. Above a temperature of 35 deg. C, the displacement data showed that random deflections as a function of time developed and that the magnitude of these deflections increased with increased temperature. We concluded that convection, not captured in the FEA, likely played a dominant role in mirror deformation at temperatures above 35 deg. C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Experimental Investigation of Flow Regimes in Imbibition and Drainage Using a Microfluidic Platform

Instabilities in immiscible displacement along fluid−fluid displacement fronts in porous media are undesirable in many natural and engineered displacement processes such as geological carbon sequestration and enhanced oil recovery. In this study, a series of immiscible displacement experiments are conducted using a microfluidic platform across a wide range of capillary numbers and viscosity ratios. The microfluidic device features a water-wet porous medium, which is a two-dimensional representation of a Berea sandstone. Data is captured using a high-resolution camera, enabling visualization of the entire domain, while being able to resolve features as small as 10 µm. The study reports a correlation between fractal dimensions of displacement fronts and displacement front patterns in the medium. Results are mapped on a two-dimensional parameter space of log M and log Ca, and stability diagrams proposed in literature for drainage processes are superimposed for comparison. Compared to recent reports in the literature, the results in this work suggest that transition regimes may constitute a slightly larger portion of the overall flow regime diagram. This two-phase immiscible displacement study helps elucidate macroscopic processes at the continuum scale and provides insights relevant to enhanced oil recovery processes and the design of engineered porous media such as exchange columns and membranes.

42 ENGINEERING↗

GPS measurements of deformation associated with the 1987 Superstition Hills earthquake: Evidence for conjugate faulting

Large station displacements observed from Imperial Valley Global Positioning System (GPS) campaigns are attributed to the November 24, 1987 Superstition Hills earthquake sequence. Thirty sites from a 42 station GPS network established in 1986 were reoccupied during 1988 and/or 1990. Displacements at three sites within 3 kilometers of the surface rupture approach 0.5 m. Eight additional stations within 20 km of the seismic zone are displaced at least 10 cm. This is the first occurrence of a large earthquake (M(sub S) 6.6) within a preexisting GPS network. Best-fitting uniform slip models of rectangular dislocations in an elastic half-space indicate 130 + or - 8 cm right-lateral displacement along the northwest-trending Superstition Hills fault and 30 + or - 10 cm left-lateral displacement along the conjugate northeast-trending Elmore Ranch fault. The geodetic moments are 9.4 x 10(exp 25) dyne-cm and 2.3 x 10(exp 25) dyne-cm for the Superstition Hills and Elmore Ranch faults, respectively, consistent with teleseismic source parameters. The data also suggest the post seismic slip along the Superstition Hills fault is concentrated at shallow depths. Distributed slip solutions using Singular Value Decomposition indicate near uniform displacement along the Elmore Ranch fault and concentrated slip to the northwest and southeast along the Superstition Hills fault. A significant component of non-seismic displacement is observed across the Imperial Valley, which is attributed in part to interseismic plate-boundary deformation.

Larsen, Shawn↗

Global positioning system measurements of deformations associated with the 1987 Superstition Hills earthquake - Evidence for conjugate faulting

Large station displacements observed from Imperial Valley Global Positioning System (GPS) compaigns are attributed to the November 24, 1987 Superstition Hills earthquake sequence. Thirty sites from a 42 station GPS network established in 1986 were reoccupied during 1988 and/or 1990. Displacements at three sites within 3 kilometers of the surface rupture approach 0.5 m. Eight additional stations within 20 km of the seismic zone are displaced at least 10 cm. This is the first occurrence of a large earthquake (M(sub S) 6.6) within a preexisting GPS network. Best-fitting uniform slip models of rectangular dislocations in an elastic half-space indicate 130 + or - 8 cm right-lateral displacement along the northwest-trending Superstition Hills fault and 30 + or - 10 cm left-lateral displacement along the conjugate northeast-trending Elmore Ranch fault. The geodetic moments are 9.4 x 10 (exp 25) dyne-cm and 2.3 x 10 (exp 25) dyne-cm for the Superstition Hills and Elmore Ranch faults, respectively, consistent with teleseismic source parameters. The data also suggest the post seismic slip along the Superstition Hills fault is concentrated at shallow depths. Distributed slip solutions using Singular Value Decomposition indicate near uniform displacement along the Elmore Ranch fault and concentrated slip to the northwest and southeast along the Superstition Hills fault. A significant component of non-seismic displacement is observed across the Imperial Valley, which is attributed in part to interseismic plate-boundary deformation.

Larsen, Shawn↗

Scaling, elasticity, and CLPT

The first few viewgraphs describe the general solution properties of linear elasticity theory which are given by the following two statements: (1) for stress B.C. on S(sub sigma) and zero displacement B.C. on S(sub u) the altered displacements u(sub i)(*) and the actual stresses tau(sub ij) are elastically dependent on Poisson's ratio nu alone: thus the actual displacements are given by u(sub i) = mu(exp -1)u(sub i)(*); and (2) for zero stress B.C. on S(sub sigma) and displacement B.C. on S(sub u) the actual displacements u(sub i) and the altered stresses tau(sub ij)(*) are elastically dependent on Poisson's ratio nu alone: thus the actual stresses are given by tau(sub ij) = E tau(sub ij)(*). The remaining viewgraphs describe the minimum parameter formulation of the general classical laminate theory plate problem as follows: The general CLT plate problem is expressed as a 3 x 3 system of differential equations in the displacements u, v, and w. The eighteen (six each) A(sub ij), B(sub ij), and D(sub ij) system coefficients are ply-weighted sums of the transformed reduced stiffnesses (bar-Q(sub ij))(sub k); the (bar-Q(sub ij))(sub k) in turn depend on six reduced stiffnesses (Q(sub ij))(sub k) and the material and geometry properties of the k(sup th) layer. This paper develops a method for redefining the system coefficients, the displacement components (u,v,w), and the position components (x,y) such that a minimum parameter formulation is possible. The pivotal steps in this method are (1) the reduction of (bar-Q(sub ij))(sub k) dependencies to just two constants Q(*) = (Q(12) + 2Q(66))/(Q(11)Q(22))(exp 1/2) and F(*) - (Q(22)/Q(11))(exp 1/2) in terms of ply-independent reference values Q(sub ij); (2) the reduction of the remaining portions of the A, B, and D coefficients to nondimensional ply-weighted sums (with 0 to 1 ranges) that are independent of Q(*) and F(*); and (3) the introduction of simple coordinate stretchings for u, v, w and x,y such that the process is neatly completed.

Brunelle, Eugene J.↗

RAINBOWS and CERAMBOWS: The Technologies of Pre-Stressed Piezo Actuators

Amplified mechanical displacement effects, similar to those observed in the recently reported Rainbow actuators, have also been found to exist in prestressed ceramic/metal composite structures coined as CERAMBOW's - an acronym for CERamic And Metal Biased Oxide Wafer. Mimicking the Rainbows in many ways, the intentionally created internal compressive and tensile stresses within the Cerambows are used to amplify their displacement properties via the combined effects of piezoelectric d31 strain and domain reorientation. They are fabricated from ferroelectric, piezoelectric or electrostrictive materials and metal substrates of significantly different thermal expansions which are largely responsible for the creation of the stress. Typical ceramics used in Cerambows are PZT, PLZT, PBZT, PSZT and PMN and some typical metal substrates are Al, Ag, Ni, brass, steel and Be/Cu foil. Shapes can vary from round disks to square plates and rectangular bars. Formed at an elevated temperature of approximately 250 C, the stresses on cooling to room temperature are generally sufficient to produce displacements as large as 0.125mm (5 mils) when activated unipolar and 0.25mm (10 mils) when operated bipolar at 450 volts in a dome mode. Comparing equal structures of a Cerambow with a Rainbow, the Cerambow was found to achieve approximately 70% of the displacement that would normally be obtained with a Rainbow. Although this difference in displacement is sufficient to prefer a Rainbow for many applications, there are some advantages for the Cerambow. Among these are (1) the processing temperatures are lower, (2) high lead-containing ceramics are not required and (3) in some instances the metal substrate is more convenient to interface with other elements of a device. However, the disadvantages include (1) lower displacement in the dome mode of operation, (2) the higher displacement saddle mode has not yet been demonstrated with a Cerambow and (3) the ceramic/metal bond interface is a possible failure area when operated for extended periods of time. The applications for Cerambows are considered to be similar to Rainbows, i.e., actuators, pumps, deflectors, vibrators, speakers, hydrophones, hydroprojectors, switches, etc.

Haertling, Gene H.↗

Mechanical and Structural Behavior of Granular Material Packed Beds for Space Life Support System Applications

Long-term human mission to space, such as living in International Space Station (ISS), Lunar, and Martian bases, and travel to Mars, must m ake use of Advanced Life Support Systems (ALSS) to generate and recycle critical life supporting elements like oxygen and water. Oxygen Gen eration Assembly (OGA) and Water Processor Assembly (WPA), critical c omponents of ALSS, make use of series of granular material packed beds for generation and recycling of oxygen and water. Several granular m aterials can be used for generation, recycling, processing and recovery of oxygen and water. For example, they may include soft bed media, e.g. ion exchange resins for oxygen generation assembly and hard bed media such as, activated alumina, magchem (Magnesium oxide) and activa ted carbon to remove organic species like ethanol, methanol, and urea from wastewater in Water recovery/processing assembly. These beds are generally packed using a plate-spring mechanism to provide sufficien t compaction to the bed media throughout the course of operation. This paper presents results from an experimental study of a full-scale, 3 8.1 cm (15 inches) long and 3.7 cm (1.44 inches) diameter. activated alumina bed enclosed in a cylinder determining its force-displacement behavior, friction mobilizing force, and axial normal stress distribu tion under various axially applied loads and at different levels of packing. It is observed that force-displacement behavior is non-linear for low compaction level and becomes linear with increase in compaction of the bed media. Axial normal stress distribution along the length of the bed media decreased non-linearly with increase in depth from the loading end of the granular media. This paper also presents experimental results on the amount of particulates generated corresponding to various compaction levels. Particulates generated from each of the tests were measured using standard US sieves. It was found that the p articulates and the overall displacement of the bed media increased with decrease in initial compaction of the bed media. This effect could be attributed to the greater tendency for inter-particle sliding/rub bing due to smaller internal friction angles, as seen from the shear tests, at lesser initial compacted levels. Upon unloading, it was obse rved that there was no change in displacement (especially rebounding) in the bed media. This effect could be attributed to the fact that th e porous activated alumina particles fracture/break upon increase in applied load (during loading phase) and occupy void spaces in between the material grains; thereby leading to settling of the media. The lo ad-displacement curve becomes more linear with increase in initial compaction of the bed media. It is concluded that compaction considerabl y affects the load-displacement behavior of the bed media. A series of tests were also conducted on the packed bed media to determine the f orce required to mobilize the friction between the bed media and the housing cylinder. The results from these tests showed the existence of significant friction between the bed media and the encasing stainles s steel cylinder. Further, it was found that friction effects were more pronounced for media with higher initial compaction. Internal frict ion of the granular media was measured using direct shear apparatus. It was observed that the internal friction increased with increase in initial compaction of the bed media. In this study, a computational m odel (CM) is also developed using finite element software ANSYS to verify experimental results obtained for the distribution of the axial n ormal stress and axial displacement along the length of the full-scal e activated alumina bed media. In the computational model, the granular material is considered to have appropriate failure and frictional c ontact exists between the wall and the granular media. It is observed that the model predicts results closely with the experimental method. The compational results show that the axial normal stress distribution along the length of the activated alumina media decreases non-linea rly from the loading end and is negligible beyond a certain depth. Th is can be attributed to the existence of friction between the walls and the media and that the friction takes up most of the applied load.

Malla, Ramesh B.↗

Comparison of Vertical Surface Deformation Estimates Derived From Space-Based Gravimetry, Ground-Based GPS, and Model-Based Hydrologic Loading Over Snow-Dominated Watersheds in the United States

Spatiotemporal variability in Earth's terrestrial water storage (TWS) causes changes in surface deformation. The potential for using ground-based Global Positioning System (GPS) vertical displacement observations for estimating TWS is explored through a comparison of vertical displacements derived from space-based gravimetric retrievals, ground-based GPS, and model-based hydrologic estimates. The study presented here focuses on two snow-dominated basins in the Western United States for the years 2003–2016. Seasonal variations are observed in the vertical displacements derived from all three data sets, and the variation is coherent with the changes in hydrologic loading. Good consistency is observed between any two of the three data sets with gravimetric retrievals and hydrologic model estimates providing the highest level of agreement (i.e., all examined stations with correlation coefficient R > 0.70). Vertical displacements derived from gravimetric retrievals and ground-based GPS yielded R > 0.70 for more than 89% of the stations. In addition, it is found that both GPS-derived and space-based, gravimetry-derived vertical displacements clearly reflected the impact of climate variation (i.e., heavy precipitation during 2010–2011 winter followed by prolonged drought). Vertical displacements derived from the hydrologic model highlighted the relatively large precipitation convergence phase during late 2010 to early 2011 at some stations but not the prolonged drought that followed. The results indicate that ground-based GPS observations of vertical displacement have the capability to capture variations in TWS changes, which can be systematically merged in conjunction with Gravity Recovery and Climate Experiment (GRACE) into a land surface model to improve TWS estimates in a follow-up study.

Gaohong Yin↗

Results of FY 2023 Alloy 617 and Alloy 709 High-Temperature Crack-Growth Testing

This report summarizes the work performed at Idaho National Laboratory under the “Creep, fatigue and creep-fatigue crack growth tests” task of the “Long-Term VHTR Material Qualification – INL” work package. Work was performed this year to validate the crack growth monitoring setup used with the test frames against both continuous crack length monitoring using an optical camera, as well as post-mortem analysis of marker bands on the fracture surface. Delays prevented the use of a gauge to measure load-line displacement for early tests, and so the creep-fatigue crack growth setup was evaluated using the actuator displacement for a load-line displacement setup. While not ideal, this allowed examination of the shortcomings with the current software setup that was originally designed for performing stress corrosion crack growth rate studies. The method for data collection was modified to link the crack growth monitoring software with Instron’s Wave Matrix software. Once the load-line displacement gauge arrived, the crack growth equipment was successfully modified to permit continuous monitoring of both load-line displacement and crack length. This is critical for creep-fatigue and creep crack growth rate studies for ductile material, as it permits the C* and Ct analyses. Test results are shown for Alloy 617 fatigue and creep-fatigue (without the gauge for load-line displacement measurements), as well as creep-fatigue of Alloy 709, which was performed with the completed test setup, allowing for crack length and load-line displacement monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considering computational speed vs. accuracy: Choosing appropriate mesoscale RVE boundary conditions

Modeling a material’s microstructure using continuum theories allows for inspection of the relationship between coarse scale and fine scale behaviors. Computational limits generally require selection of a sub-volume from a bulk sample in order to directly model the microstructure. Boundary conditions are applied to the sub-volume to mimic the excluded bulk material. Appropriate selection of boundary conditions helps effectively determine the appropriate spatial scale required of the sub-volume. Applicable boundary conditions include direct displacement, periodic, and uniform traction. While direct displacement and periodic boundary conditions are commonly used, uniform traction boundary conditions have seen limited use due to rigid body stability issues in simulations of compression or shear deformation. A new application of uniform traction boundary conditions was developed through linear constraint equations, similar to approaches employed by direct displacement and periodic boundary conditions, to quench rigid body motions with minimal interference of the relative deformation of the model. These boundary conditions were tested by compressing several synthetically generated periodic microstructures using the finite element method. Evaluating the effective stiffness along the compression axis, the direct displacement boundary condition produced the stiffest response, whereas the uniform traction boundary condition produced the most compliant. Periodic boundary conditions produced the same response for all volumes analyzed and both the direct displacement and uniform traction boundary conditions trended toward the periodic response as the domain volume increased. Computational performance was also evaluated for each boundary condition using implicit and explicit solvers. Direct displacement boundary conditions presented the lowest computational cost of all of the boundary conditions followed by periodic then uniform traction. The computational expense of periodic and uniform traction boundary conditions limited the viable spatial scale and mesh resolutions able to be simulated. Selection of appropriate boundary conditions for specific uses need to be a balance between allowable computational expense and accuracy of the method. Techniques for evaluating which boundary conditions to use are discussed.

42 ENGINEERING↗

Impact of induced seismic events on seal integrity, Texas Gulf Coast

Recent publications have suggested that large-scale CO 2 injection could trigger earthquakes and that even small- to moderate-sized earthquakes may threaten the seal integrity of the injection zone, and potentially damage buildings and other surface structures. In this study, we compared seal thickness to estimated fault displacement due to a single hypothetical seismic event in a selected area of the Texas Gulf Coast comprising an offshore strip of state waters along two Texas counties. To evaluate the slip generated by a single seismic event, we compiled well log information on shale/sand sequences and seismic information on fault geometric characteristics of a section of Lower Miocene age. The section is thousands of feet thick and is overlain and underlain by marine shales (Amph. B and Anahuac, respectively) that are relatively easy to correlate between wells. The Amph. B. shale is the secondary and ultimate seal for all injection intervals in the Lower Miocene. Given its thickness, no realistic seismic event or small series of seismic events will offset it significantly. However, this may not be true of smaller local primary seals. An analysis of geophysical logs of a total of 71 wells yielded a total of 2,871 sand / shale binary intervals. An analysis of the dedicated 3D seismic survey counted 723 fault traces at five roughly horizontal horizons within the Lower Miocene Fault displacement estimated using the product of the fault length times an uncertain multiplier coefficient assumed to follow a triangular distribution with a 10 -3 to 10 -5 range and a mode of 8 × 10 -5 . We then compared estimated single-event fault displacements to seal thicknesses by means of a Monte-Carlo analysis. Only 1.8% of thickness/displacement pairs display a displacement greater than 20% of the seal thickness. Only 0.26% of the pairs result in a displacement of half the seal thickness and only 0.05% of thickness/displacement pairs result in a clear seal rupture. The next step was to compare the magnitude of the event generated by such a displacement to documented magnitudes of “large” earthquakes generated by waterflooding and fluid disposal. Based on this analysis, we conclude that seismicity that may arise from CO 2 injection appears not to be a serious complication for CO 2 storage integrity, at least in the Gulf Coast area.

54 ENVIRONMENTAL SCIENCES↗